    							1 Boot from SAN
    Thischapterdescribesbootsetupproceduresfromastorageareanetwork(SAN)withtherequired
    softwareandhardwareusingHPEmulexHBAsorHPQLogicHBAsrunningonItaniumorProliant
    Windowssystems.Forthelatestversionofthisdocument,seetheHPstoragewebsite:
    http://h18006.www1.hp.com/storage/networking/index.html
    Traditionally,HPserversbootoperatingsystemsfrominternalSCSIorIDEstoragedevices.Withthe
    supportofexternalbootingfromHPStorageWorksHBAsandRAIDarrays,youhavetheoptionto
    eliminateserver-basedinternalbootdevices.Bootingfromanexternaldevicedecreasesdowntime
    throughfasterserverreplacementintheeventofaserverorHBAfailure.
    IMPORTANT:
    For important troubleshooting information, see 3 Troubleshooting.
    BFS Rules and Assumptions
    Makesurethatthefollowingrulesandassumptionsaremetbeforeyoubegin.
    •AllrulesandassumptionsintheAboutthisguidechapter,aswellasthischapter,havebeensat-
    isfied.
    •OneavailablepathfromHBAtostorageLUN.
    •Inadditiontothisguide,seethefollowingdocumentation:
    •ReleasenotesforHPStorageWorksEmulexhostbusadaptersforWindows.
    •ReleasenotesforHPStorageWorksQLogichostbusadaptersforWindows.
    •Whitepapersandbest-practicesdocuments.
    ToinstallWindowsonaBootfromSANLUNwithdriverversionsthatarenotsupportedbytheinitial
    operatingsystemrelease,thenewdrivermustbeintegratedaspartoftheinstallationprocessusing
    aBFSkit.
    Why boot from SAN?
    BootingfromSANprovides:
    •Improveddisasterrecovery
    •ReducedbackuptimewhenthebootpathisthroughaSAN
    •AdditionalSAN-managedfeatures
    FibreChannelhostbusadapterssoftwareguideforWindows11  
    						
    							Required hardware and software
    ThefollowingtableliststhehardwareandsoftwarerequiredtobootfromaSAN.
    Table 3 Required hardware and software
    RequirementSupported feature
    DatacenterEnterpriseandStandardeditionsof:
    •WindowsServer2003forItanium-basedsystems.
    •WindowsServer2003withSP1forItanium-basedsystems.
    •WindowsServer2003x86/x64.
    •WindowsServer2008x86/x64
    NOTE:
    All operating systems requires the latest supported Microsoft Service Pack.
    Operatingsystems
    EVA
    MSA
    XP
    RAIDarrays
    AllHPsupportedFibreChannelswitches,runningthelatestreleasedswitchfirmware
    aresupportedinaBootFromSANconfiguration.Formoreinformation,seethewebsite
    http://h18006.www1.hp.com/storage/networking/index.html
    FibreChannel
    switches
    AllHPProLiantservers,includingHPProLiantbladeservers,aresupportedunless
    otherwisenoted.Formoreinformation,seethewebsite
    http://h18004.www1.hp.com/products/servers/platforms/storage.html
    IfyouareusingtheRapidDeploymentPack,seethesupportmatrixforthesupported
    serversonthewebsite
    http://www.hp.com/servers/rdp
    NOTE:
    Boot from SAN does not support the DL140 and DL145 line of servers.
    Servers
    BootfromSAN12 
    						
    							RequirementSupported feature
    HPEmulex8GbPCI-Expresssingleporthostbusadapter,partnumberAJ762A
    HPEmulex8GbPCI-Expressdualporthostbusadapter,partnumberAJ763A
    HPEmulexFibreChannelmezzanineHBAforHPp-classsystemsforBL30pG1,BL25p,
    BL35p,andBL45p,partnumber394588-B21
    HPEmulexFibreChannelmezzanineHBAforHPp-classsystemsforBL20pG3,part
    number394757-B21
    HPEmulexLPe1105-HP4GbFCHBAforHPc-ClassBladeSystem,partnumber
    403621-B21
    HPQLogic8GbPCI-Expresssingleporthostbusadapter,partnumberA334A
    HPQLogic8GbPCI-Expressdualporthostbusadapter,partnumberAJ764A
    HPQLogicQMH24624GbFCHBAforHPc-ClassBladeSystem,partnumber
    403619-B21
    HPQLogicDualPortFibreChannelMezzanineHBA2-GbforBL20Gp2G2,part
    number300874-B21
    1050EXPCI-Expresshostbusadapter,partnumberA7650A
    64-bitPCItoFibreChannel1-GBhostbusadapterDS-KGPSA-CB,partnumber
    176479-B21
    A7387Adual-channelPCI-X2-GBhostbusadapter,partnumberA7650A
    A7388APCI-X2-GBhostbusadapter,partnumberA7388A
    FCA21012-GB,hostbusadapter,partnumber245299-B21
    FCA2355DC2-GBPCI-Xhostbusadapter,partnumber308540-B21
    FCA22142-GBPCI-Xhostbusadapter,partnumber281541-B21
    FCA2214DC2-GBPCI-Xhostbusadapter,partnumber321835-B21
    FCA24042-GBPCI-Xhostbusadapter,partnumber305573-B21
    FCA2404DC2-GBPCI-Xhostbusadapter,partnumber323264-B21
    FCA24082-GBPCI-Xhostbusadapter,partnumber343073-B21
    FC2142SR4GbPCI-Expresshostbusadapter,partnumberA8002A
    FC2242SR4GbPCI-Expresshostbusadapter,partnumberA8003A
    FC21434GbPCI-X2.0hostbusadapter,partnumberAD167A
    FC22434GbPCI-X2.0hostbusadapter,partnumberAD168A
    FC11434GbPCI-Expresshostbusadapter,partnumberAE311A
    FC12434GbPCI-Expresshostbusadapter,partnumberAE312A
    HPBL20pG2FibreChannelMezzAdapter,productnumber300874-B21
    HPBL20pG3FibreChanneladapter,productnumber361426-B21
    HPBL30p/BL35pDual-PortFibreChanneladapter,productnumber354054-B21
    HPBL25p/BL45pFibreChanneladapter,productnumber381881-B21
    Forthelatestinformationonfirmware,driverandBIOSversions,aswellasLUN
    limitations,seethewebsite
    •http://h18006.www1.hp.com/storage/networking/index.html.
    HBAs
    Seethewebsitehttp://h18006.www1.hp.com/storage/networking/index.htmlfor
    thelatestinformationonthefollowing:
    •EmulexEFI-basedSetupUtility(ESBU)
    •EmulexEFIfirmware
    •HPSmartSetupMedia
    ExtensibleFirmware
    Interface(EFI)
    FibreChannelhostbusadapterssoftwareguideforWindows13 
    						
    							Restrictions
    ThefollowingsectionsdescriberestrictionsforbootingfromaSAN.
    Operating system restrictions
    Thefollowingoperatingsystemrestrictionsapply:
    MicrosoftWindowsoperatingsystemsrequireaunique,dedicateddiskforbooting.Therefore,each
    serverconnectedtoaRAIDarraymusthaveitsowndisk,orlogicalunitnumber(LUN),dedicatedfor
    bootingandoperatingsystemfiles.Datacanbeallocatedacrossboththebootdiskandtheremaining
    disks.Bootingfromarray-baseddiskpartitionsispossible.
    NOTE:
    For Windows Server 2003, a crash dump file will not be generated if the path to the system drive is
    different from the active path established if the system was booted at the time of a system crash. To
    ensure that a crash dump is created, move the system disk back to the active boot time path as soon
    as possible, after any failure. For detailed information a file creation, see the website
    http://download.microsoft.com/download/f/9/7/f9775acc-baa6-45cc-9dec-b82983705620/
    Boot%20from%20SAN%20in%20Windows.doc
    Clustered server restrictions
    ThissectiondescribesclusteredserverrestrictionsforStorportminiportdrivers.
    Storport miniport driver restrictions
    •ForStorportminiportdriverrestrictions,seethefollowingMicrosoftarticles:
    •TosetupMSCSproperly,seeClusterisformedbyusingalocalquorumresourceafteracluster
    setupfailureinWindowsServer2003,availableatthewebsite
    http://support.microsoft.com/?kbid=888160
    •ForbootfromSANandMSCSconfigurationsonWindowsServer2003systems,seetheup-
    datedStorportstoragedriver,version5.2.3790.2494thatisavailableforWindowsServer
    2003availableatthewebsite
    http://support.microsoft.com/kb/912944/en-us
    AlsoseeHowtoaddaregistryvaluetoaWindowsServer2003-basedcomputerthatyou
    startfromaSANsothatthestartupdisk,thepagefiledisks,andtheclusterdisksareallon
    thesameSANfabric,availableonthewebsite
    http://support.microsoft.com/kb/886569/en-us
    •Toavoidimpropermodificationoftheregistry,usetheBootfromSANClusterRegistryUpdate
    utilitytoaddtheManageDisksOnSystemBuseskey.Downloadtheutility(BFSCLRegUp.exe)
    fromthewebsite
    http://h18006.www1.hp.com/storage/saninfrastructure.html
    •AminimumoftwoHBAportsperhostisrequiredforaHighAvailability(HA)configuration.
    Fordetailedinformation,seetheProLiantHighAvailabilitywebsite
    http://h18004.www1.hp.com/solutions/enterprise/highavailability/index.html
    BootfromSAN14 
    						
    							Reconfiguring HBA zoning to avoid time-out conditions
    InbootfromSANconfigurationswheretherearemorethantwoEmulexHBAsinthesamezoneas
    thebootHBA,atime-outconditionmayoccurwhenthebootHBAinteractswiththenon-bootHBAs,
    causingacrash-dumptonotbegenerated.Toavoidtime-outconditions,reconfigurethezoningso
    thatthebootinstanceforeachpathisinitsownzone,separatefromtheothernon-bootHBAs.This
    mayalsoresultinfasterboot-uptimes.
    Server replacement in the event of a server failure
    IfyouretainingtheoriginalHBAs,placethemintheircorrespondingPCIslotsonthereplacement
    server.IfyouarenotretainingtheoriginalHBAs,makesureto:
    •RebuildtheboottablewiththenewHBAIDinformation.
    •RemovetheoriginalHBAsfromtheirzones,andreplacethemwiththenewHBAs.
    •RemovetheoriginalHBAsfromtheirarraystoragepresentationandreplacethemwiththenew
    HBAs.
    Prerequisites
    TosetupbootingfromaSAN,youshouldbefamiliarwith:
    •EVA,MSA,orXPFibreChannelRAIDarrays.ThisinformationisintheRAIDarray.
    •Familiaritywithswitch-basedzoning.Forinformationaboutzoningforyourenvironment,seeyour
    switch’sinstallationguidedocumentation.
    Thefollowingproceduresarenotfullydescribedinthisdocument.However,inordertoperformboot
    fromSANsetupprocedures,youwillneedtocompletethem.
    •MSA,EVAandXP
    •HPhighlyrecommendscreatinganewbootLUNsothatyouwillbeginwithacleanandun-
    partitionedvirtualdisk.
    •Verifyingthatthestorageunitshavetheproperaccess.
    •Switchconfigurationsandzoning—Checktheswitchtoensuretherearenozoningconflicts.You
    mustsetupswitchzoningaspartofyourconfiguration.
    •IfyouareusingtheRapidDeploymentPack,seetheRDPdocumentation.
    Supported configurations
    Thisdocumentdescribessingle-server,cluster,multipathconfigurationsusing:
    •EVA
    •MSA
    •XP
    RAID arrays
    PerformthefollowingforEVA,MSA,andXParrays:
    •Verifythatallexistingstorageunits(virtualdisks)havetheproperaccesssettings.
    •Withswitch-basedconfigurations,ifzoningisenabled,checktheswitchtoensurethereareno
    zoningconflicts.
    FibreChannelhostbusadapterssoftwareguideforWindows15 
    						
    							Working with boot disk partitions
    •Beforecreatingabootdisk,youmuststartwithaclean,unpartitionedvirtualdisk.
    •CreateaLUNthatisatleast32GBforW2K3and46GbforW2K8.
    •WhenbootingfromaRAIDarraythathasothervirtualdisksattachedtootherservers,beaware
    thatwhensettingupbootingforthenewserver,theinstallationprogrammaydisplayalistof
    partitionsvisibleforloadingtheoperatingsystem.Thedisplaycontainsadiskforeverycontroller
    portaccessiblebytheHBA.
    •HPrecommendsthatonlyoneinstanceofthebootLUNbevisibletotheserverduringtheinitial
    installation.TheinstallationmayfailifmultipleinstancesofthebootLUNareavailabletothe
    server.
    Switch-based zoning
    Youmustbefamiliarwithswitch-basedzoning.Forspecificinformationaboutzoningforyour
    environment,seeyourswitch'sinstallationguide.
    Cabling options for single-channel HBAs
    SANbootissupportedinthezonedsingle-channelHBAconfigurations,asshowninFigure1through
    Figure6.
    Figure 1 Single server, two single-channel HBAs, one switch, straight-cable storage configuration
    .
    BootfromSAN16 
    						
    							Figure 2 Single server, two single-channel HBAs, one switch, cross-cable storage configuration
    .
    Figure 3 Single server, one HBA, one switch configuration
    .
    ThefollowingconfigurationsshowninFigure4andFigure5supportSCSIPORTorStorportminiport
    drivers.
    Figure 4 Single server, two single-channel HBAs, two switches, straight-cable HA storage configuration
    .
    FibreChannelhostbusadapterssoftwareguideforWindows17 
    						
    							Figure 5 Single server, two single-channel HBAs, two switches, straight-cable HA storage configuration
    .
    TheconfigurationshowninFigure6supportsSCSIPORTorStorportminiportdrivers.
    Figure 6 Clustered servers, four single-channel HBAs per server, two switches, cross-cable HA storage
    configuration
    .
    Cabling options for dual-channel HBAs
    Dual-channelHBAsaretypicallyusedwhenthenumberofserverPCIslotsislimited.Figure7through
    Figure12showthecablingoptionsfordual-channelHBAs.
    BootfromSAN18 
    						
    							Figure 7 Single server, one dual-channel HBA, one switch, straight-cable storage configuration
    .
    Figure 8 Single server, one dual-channel HBA, one switch, straight-cable storage configuration
    .
    Figure 9 Single server, one dual-channel HBA, two switches, cross-cable storage configuration
    .
    TheconfigurationshowninFigure10requiresaStorportminiportdriver.
    FibreChannelhostbusadapterssoftwareguideforWindows19 
    						
    							Figure 10 Single server, one dual-channel HBA, two switches, straight-cable HA storage configuration
    .
    Figure 11 Single server, one dual-channel HBA, two switches, cross-cable HA storage configuration
    .
    TheconfigurationshowninFigure12supportsStorportminiportdrivers.
    BootfromSAN20 
    						
    All HP manuals Comments (0)

    Related Manuals for HP Storageworks Boot From San Manual