Home > Miele > Washer > Miele G 7881 User Manual

Miele G 7881 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Miele G 7881 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 171 Miele manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Refill Salt Indicator
    The water softener is automatically
    regenerated during the next program
    cycle.
    The program display will showa
    Recharging during this process.
    ^Add regeneration salt whenever the
    Refill salt indicatorbRecharge is on.
    Water softener
    21 
    						
    							Depending on the type of items you
    wish to clean and disinfect, the
    washer-disinfector can be used with an
    upper basket and/or lower basket, as
    well as, an assortment of inserts and
    special baskets to suit your needs.
    Baskets and inserts should be
    properly selected to match the
    application involved.
    On the following pages you will find
    loading examples and additional
    information.
    Before EVERY program start,
    conduct the following visual
    inspection:
    – Are the items properly loaded and
    secured in the machine?
    – Are the hollow items properly loaded
    so that all cavities and channels will
    be flushed clean?
    –
    Are the spray arms clean and can
    they rotate freely?
    –
    Is the filter combination free of
    coarse debris (remove any coarse
    material and clean the coarse, fine,
    flat and micro-fine filters as needed)?
    –
    Is the basket adapter properly
    connected to the water supply for the
    spray arms and nozzles?
    –
    Are the process chemical dispensers
    filled?After EVERY program completion,
    conduct the following visual
    inspection:
    –Inspect the items for cleanliness.
    –After washing, items should be
    checked at random for protein
    analysis, e. g., with the Miele Test Kit.
    –Have any hollow items been
    dislodged from their proper position
    on the nozzles?
    ,Any items that were dislodged
    from the adapters during a program
    cycle must be washed again.
    – Are the cavities and channels in any
    hollow items cleaned through?
    – Are the nozzles and connections
    firmly attached to the
    baskets/inserts?
    Application
    22 
    						
    							How to load the machine
    –Always load items in such a way that
    all surfaces will be exposed to the
    cleaning water. This ensures that the
    items will be properly clean.
    –Do not nest any items inside other
    items. Keep each item separate.
    –Hollow items must be arranged for
    complete inside exposure to the
    cleaning water.
    –Hollow items should be inverted and
    placed in suitable baskets and
    inserts so that the water will have
    unrestricted access and exit.
    – Deep-based items should be
    arranged at an angle, so that water
    can run off easily.
    – Tall narrow pieces should be placed
    in the center of the basket for best
    water coverage.
    – Baskets and inserts with an adapter
    must be properly connected.
    –
    The spray arms must not be blocked
    by items that are too tall or hang
    through the baskets.
    –
    To avoid corrosion, only load
    stainless steel items in good
    condition.
    –
    Do NOT use this machine to wash
    nickel-plated items or discolored
    (oxidized) aluminum items.
    –
    Do not load plastics unless they are
    heat-resistant.–NEVER process disposable items in
    the washer-disinfector.
    Prepare items before loading
    ^Empty all items before loading into
    the machine. Comply with all
    applicable infection-control
    regulations.
    ,Ensure that no acid or solvent
    residues, especially hydrochloric
    acid or chlorides, get inside the
    machine.
    Item sorting
    Contaminated items should be placed
    directly in the washer-disinfector
    without pre-treatment (dry handling).
    Application
    23 
    						
    							Spring adapter for the water
    connection
    The spring adapter for the water
    connection must be properly engaged
    when a basket is inserted into the
    machine. In other words, the adapter
    must be4-5mmhigher than the water
    inlet in the machine.
    If this is not the case, the adapter
    needs to be adjusted as follows:
    ^
    Loosen the locking ringa.
    ^
    Move the adapter up to the proper
    heightb.
    ^
    Tighten down the locking ringc.
    How to adjust the upper basket
    The upper basket can be adjusted
    above and below the middle position
    by 2 cm each.
    Depending on the height selected, and
    which inserts are used, items of various
    heights can be arranged in the baskets.
    To adjust the upper basket:
    ^Pull the upper basket out as far as it
    will go, lift it up off the runners and
    remove.
    ^Use a 7mm wrench to unscrew the
    roller bearings on either side of the
    basket, then reposition as desired.
    Application
    24 
    						
    							Application
    During patient treatment, check thatas
    little residue as possible (dental
    cement, polishing compound, etc.)is
    left on the items (wipe off as needed).
    After thermal disinfection, manual
    cleaning in accordance with the
    biological materials ordinance can be
    conducted without danger of infection.
    Rhodium coated mirrors must be
    arranged so that their surfaces do
    not suffer any mechanical damage.
    Not all glass coated mirrors are
    suitable for machine processing.Lower basket U 874/2
    for inserts, e.g., E 130 and E 379.
    Lower basket U 874/2
    for inserts, e.g., E 131/1 for 5 filing
    trays with partitions E 146 or 5 filing
    trays for two-sided instruments E 363.
    Application
    25 
    						
    							Adding rinse aid
    Rinse aid is needed to ensure that
    water promptly falls away from the
    washload, preventing spots and
    speeding up the drying process.
    Rinse aid (Mielclear) is loaded into the
    reservoir and a pre-set amount is
    dispensed automatically.
    The rinse aid reservoir holds
    approximately 180 ml.
    ,Inadvertently filling the rinse aid
    reservoir with detergent WILL
    damage the machine. Be sure only
    to use rinse aid in the rinse aid
    reservoir.
    ^Open the machine door.
    ^
    Unscrew the reservoir cap.^Pour enough rinse aid into the
    reservoir until the level indicator (see
    arrow) is dark. Use a funnel if
    necessary.
    ^Replace and tighten the reservoir
    cap.
    ^Wipe up any spilled rinse aid to
    prevent oversudsing during the next
    wash cycle.
    Dispensing processing chemicals
    26 
    						
    							Rinse aid indicator light
    ^Rinse aid does not need to be refilled
    until the "rinse" indicator light comes
    on in the display.
    Setting the rinse aid dosage
    The dosage adjuster has settings from
    1 to 6 (in other words,1-6ml). The
    factory setting is at 3 ml.
    If the items show spots after washing,
    ^adjust to a higher setting.
    If the items show smearing or cloudy
    streaks after washing,
    ^adjust to a lower setting.
    Dispensing processing chemicals
    27 
    						
    							How to add neutralizer
    For certain programs, neutralizer is
    dispensed in the rinse cycle after
    washing, to help prevent discoloration
    and corrosion spots on the items
    (especially around jointed areas).
    Neutralizer (pH = acidic) also helps
    counteract any traces of (alkaline)
    detergent from the surface of the items.
    When a mild alkaline detergent is
    used for washing, select a
    neutralizer that contains phosphoric
    acid.
    When a neutral enzymatic liquid
    detergent is used, select a
    neutralizer that contains citric acid.
    The neutralizer is automatically
    dispensed during the second rinse
    after the main wash cycle. To function
    properly, the neutralizer container must
    be filled and cleared of air (primed).
    For specific instructions on how to
    prime the system and set the dosage,
    please read the section on
    "Programming special functions".^Place the neutralizer container (red)
    next to the machine on the floor or in
    an adjacent cabinet.
    ^Insert the siphon tube into the
    container opening and screw it into
    place.
    Dispensing processing chemicals
    28 
    						
    							Neutralizer indicator light
    ^When the "Neutralizer" indicator light
    comes on, it is important to promptly
    refill or exchange the neutralizer
    container.
    The "Neutralizer" indicator light should
    turn off.
    ^If the container has been allowed to
    run dry, the light will not go out until
    the priming process is performed
    (See "priming the neutralizer
    dispensing system").
    Be sure to refill / exchange the
    container before it becomes
    completely empty.
    Dispensing processing chemicals
    29 
    						
    							How to add detergent
    Using powder detergent
    Before starting the program, load the
    powdered detergent into the receptacle
    (except for the programs "Rinse" and
    "Drain").
    Examples:
    In the program cycle "Main Wash",
    approximately 10.5 liters of water flow
    into the machine.
    To achieve a detergent concentration of
    approximately 3 g/l, use 30 g of
    detergent.
    Always follow the detergent
    manufacturer's recommendations for
    dosage concentration.^Press the button on the dispenser
    cover. The cover will pop open.
    After a completed wash program, the
    cover will already be open.
    ^
    Load the detergent into the
    receptacle.
    ^
    Snap the cover closed.
    ,After program completion, check
    to see that all the detergent
    dissolved completely.
    If not, the entire program should be
    repeated.
    Dispensing processing chemicals
    30 
    						
    All Miele manuals Comments (0)

    Related Manuals for Miele G 7881 User Manual