    SYSTEM MESSAGES
    This message displays when the system detects all the failures concerned with input clock down or output clock
    down in the PLO/CLK card (one of dual system).
    ➀ Details on detected PLO
    Note 1:For CLK in TSWM1 (used in LN only).
    Note 2:For PLO in TSWM0 (used in LN only).
    ➁ Valid Information bit for Scan 
    Data 1
    ➂ Valid Information bit for Scan 
    Data 2
    See Chapter 4 for the Circuit Card Replacement Procedure.
    1:XXXX XXXX XX00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN1-PPLO FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 PLO/No. 1 PLO
    b6: 0/1 = -/CLK card failure Note 1
    b7: 0/1 = -/PLO card failure Note 2
    b0-b7: The bit position corresponding to the detected information in Scan 
    Data 1 ( ) is flagged “1”.
    ➃
    b0-b7: The bit position corresponding to the detected information in Scan 
    Data 2 ( ) is flagged “1”.
    ➄ 
    						
    							CHAPTER 3 NDA-24307
    Pag e 8 4
    Issue 1
    SYSTEM MESSAGES
    ➃ Scan Data 1: Status of the PLO card
    ➄ Scan Data 2: Current status of the 
    PLO card
    Note 1:The clock status includes that of PH-CK18 (CLK) card.
    Note 2:This information includes the failure detected in PH-CK18 (CLK) card. b7 b6 b5 b4 b3 b2 b1 b0
    b4 b1 b0
    b0: Clock status at the time of detection Note 1
    0/1 = STBY/ACT
    b1: Circuit card status at the time of detection
    0/1 = PLO synchronizing/PLO self running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of Input clock 
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down Note 2
    b7: 0/1 = -/Drifting
    b3b4DCS Input RouteRoute of Input Clock
    00 0 0
    01 1 1
    10 - 2
    11 - 3
    b0: 0/1 = -/5msec clock down
    b1: 0/1 = -/Frame signal from SYNC card is down
    b4: 0/1 = -/Internal OSC clock down 
    						
    							NDA-24307 CHAPTER 3
    Page 85
    Issue 1
    SYSTEM MESSAGES
    This message displays when a fault of the speech path system has occurred in a specific Module Group. The
    specific Module Group is placed into make-busy state.
    ➀ MG number of fault detection
    ➁ The kind of failure
    ➂ Speech Path/Clock System
    See Chapter 4 for the Circuit Card Replacement Procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b1 b0
    Default Alarm:
    MJ1-SModule Group Down FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = Even-numbered MG/Odd-numbered MG
    b0-b7: 00H/01H = -/ACT-side TSW fault
    b0: ACT side speech path
    0/1 = No. 0 system/No. 1 system
    b1: ACT side clock
    0/1 = No. 0 system/No. 1 system 
    						
    							CHAPTER 3 NDA-24307
    Pag e 8 6
    Issue 1
    SYSTEM MESSAGES
    This message displays when the changeover of the TSW system is executed.
    ➀ACT side Speech Path (TSW) after 
    changeover
    ➁ Reason for changeover
    1: XXXX 0000 XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 XXXX XXXX
    ➀  ➁ ➂  ➃ ➄  ➅  
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON1-TTSW ACT Change ReportDefault Grade:
    2Grade Modified: Lamp Modified:
    192122
    b0: 0/1 = No. 0 system/No. 1 system
    b7-b4b3-b0CARDCONTENTS
    01TSWI/O Alarm
    2 32 ch Clock down, FH down
    3 24 ch Clock down, FH down
    6 TSW SW Memory write failure
    9 I/O Alarm release
    10 32 ch Clock down recovered, FH down 
    recovered
    11 24 ch Clock down recovered, FH down 
    recovered
    13 TSW MBR key OFF
    15 TSW ACT/STBY changeover by the 
    CMODI command
    6 1 MUX MUX circuit card Ready failure
    2 MUX circuit card Clock failure
    20 
    						
    							NDA-24307 CHAPTER 3
    Page 87
    Issue 1
    SYSTEM MESSAGES
    ➂~➅ Status of ACT side TSW card
    ~
     Status of STBY side TSW 
    card b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b3, b4-b7: The status of TSW card in each MG (00~07)
    0000 = Normal
    0001 = Abnormal (Impossible to make links)
    ➂MG00 MG01
    ➃MG02 MG03
    ➄MG04 MG05
    ➅MG06 MG07
    b7-b4 b3-b0
    b0-b3, b4-b7: The status of TSW card in each MG (00~07)
    0000 = Normal
    0001 = Abnormal (Impossible to make links)
    MG00 MG01
    MG02 MG03
    MG04 MG05
    MG06 MG07
    b7-b4 b3-b019
    20
    21
    22
    1922 
    						
    							CHAPTER 3 NDA-24307
    Pag e 8 8
    Issue 1
    SYSTEM MESSAGES
    This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more
    than 16 times an hour. At this time, the faulty DLKC card is shut and its switching network automatically
    changes over.
    ➀ System status of faulty DLKC card
    ➁ Error Code
    ➂ Details on Switching Network
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b1 b0
    Default Alarm:
    MN1-UDLKC Data Transfer Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    01H: Firmware fault
    02H: Data transfer time out to DLKC
    03H: No answer time out (at DLKC)
    04H: Data parity error
    b0: Status of Speech Path System (including DLKC)
    0/1 = No. 0 system is ACT/No. 1 system is ACT
    b1: Status of basic clock
    0/1 = No. 0 system is ACT/No. 1 system is ACT 
    						
    							NDA-24307 CHAPTER 3
    Page 89
    Issue 1
    SYSTEM MESSAGES
    This message displays when a data sending error or no answer error occurs at the time of data transfer from
    CPU to DLKC card.
    ➀ System status of faulty DLKC card
    ➁ Error Code
    ➂ Details on Switching Network
    Note:This data displays when the STBY DLKC card is detected as faulty.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    SUP1-VDLKC Data Transfer Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    01H: Firmware fault
    02H: Data transfer time out to DLKC
    03H: No answer time out (at DLKC)
    04H: Data parity error
    b0: Status of Speech Path System (including DLKC)
    0/1 = No. 0 system is ACT/No. 1 system is ACT
    b1: Status of basic clock
    0/1 = No. 0 system is ACT/No. 1 system is ACT
    b7: Information on Reset of STBY DLKC  Note
    0/1 = - /STBY DLKC card was reset 
    						
    							CHAPTER 3 NDA-24307
    Pag e 9 0
    Issue 1
    SYSTEM MESSAGES
    This message displays when a PLO/CLK-related failure, such as internal clock down is restored.
    ➀ Restoration of PLO fault
    ➁ Current status of PLO card
    ➂ Current status of the PLO card
    Note 1:The status includes that of PH-CK18 (CLK) card.
    Note 2:This information includes the failure detected in PH-CK18 (CLK) card.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4 b1 b0
    Default Alarm:
    NON1-WPLO RestoreDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = PLO No. 0 system/PLO No. 1 system
    b0: 0/1 = Clock is in STBY side/ACT side Note 1
    b1: 0/1 = PLO synchronizing/PLO self running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of input clock (see the table below)
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down Note 2
    b7: 0/1 = -/Drifting
    b4b3Connected With Primary 
    Oscillator (M-OSC)Connected With 
    External Clock
    0 0 No. 0 M-OSC Route 0
    0 1 No. 1 M-OSC Route 1
    10–Route 2
    11–Route 3
    b0: 0/1 = -/5msec clock down
    b1: 0/1 = -/Frame Synchronization from SYNC card is down
    b4: 0/1 = -/Internal OSC clock down 
    						
    							NDA-24307 CHAPTER 3
    Page 91
    Issue 1
    SYSTEM MESSAGES
    This message (for the ISW only) displays when a TSW card (one of the dual systems) of ISW fails to receive
    the CLK/FH signals, sent from the LN side.
    ➀ TSW detected as faulty
    ➁,➂ Details on the fault (TSW No. 0 
    side)
    ➁
    ➂
    Note 1:This data is displayed when b0 of ➀ is set as “1.”
    Note 2:For more information on each lamp, refer to the “Circuit Card Manual.”
    1: XX00 XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂
    ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00
    b7 b6 b5 b4 b3 b2 b1 b0
    LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200
    Default Alarm:
    NON1-XLN 
    →
    →→ → ISW CLK/FH Failure
    Default Grade:
    0Grade Modified: Lamp Modified:
    b0: 0/1 = -/No. 0 system
    b1: 0/1 = -/No. 1 system
    The bits here correspond to “LN00” through “LN33” lamps, apiece, on a 
    TSW (PU-SW00) card of No. 0 system. If “1” is set, the corresponding PCM 
    traffic has encountered a CLK/FH failure.
    0: -
    1: LN 
    → ISW CLK/FH Failure 
    						
    							CHAPTER 3 NDA-24307
    Pag e 9 2
    Issue 1
    SYSTEM MESSAGES
    ➃,➄ Details on the fault (TSW 1 
    side)
    ➃
    ➄
    Note 1:This data is displayed when b1 of ➀ is set as “1.”
    Note 2:For more information on each lamp, refer to the “Circuit Card Manual.” b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00
    b7 b6 b5 b4 b3 b2 b1 b0
    LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200
    The bits here correspond to “LN00” through “LN33” lamps, apiece, on a 
    TSW (PU-SW00) card of No. 1 system. If “1” is set, the corresponding PCM 
    traffic, once detected as faulty, has recovered.
    0: -
    1: LN 
    → ISW CLK/FH Failure 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Ipx System Operations And Maintenance Manual