NDA-24307 CHAPTER 3 Page 83 Issue 1 SYSTEM MESSAGES This message displays when the system detects all the failures concerned with input clock down or output clock down in the PLO/CLK card (one of dual system). ➀ Details on detected PLO Note 1:For CLK in TSWM1 (used in LN only). Note 2:For PLO in TSWM0 (used in LN only). ➁ Valid Information bit for Scan Data 1 ➂ Valid Information bit for Scan Data 2 See Chapter 4 for the Circuit Card Replacement Procedure. 1:XXXX XXXX XX00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: MN1-PPLO FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 PLO/No. 1 PLO b6: 0/1 = -/CLK card failure Note 1 b7: 0/1 = -/PLO card failure Note 2 b0-b7: The bit position corresponding to the detected information in Scan Data 1 ( ) is flagged “1”. ➃ b0-b7: The bit position corresponding to the detected information in Scan Data 2 ( ) is flagged “1”. ➄

CHAPTER 3 NDA-24307 Pag e 8 4 Issue 1 SYSTEM MESSAGES ➃ Scan Data 1: Status of the PLO card ➄ Scan Data 2: Current status of the PLO card Note 1:The clock status includes that of PH-CK18 (CLK) card. Note 2:This information includes the failure detected in PH-CK18 (CLK) card. b7 b6 b5 b4 b3 b2 b1 b0 b4 b1 b0 b0: Clock status at the time of detection Note 1 0/1 = STBY/ACT b1: Circuit card status at the time of detection 0/1 = PLO synchronizing/PLO self running or drifting b2: 0/1 = -/Input clock down b3, b4: Route of Input clock b5: 0/1 = -/PLO input all down b6: 0/1 = -/PLO output down Note 2 b7: 0/1 = -/Drifting b3b4DCS Input RouteRoute of Input Clock 00 0 0 01 1 1 10 - 2 11 - 3 b0: 0/1 = -/5msec clock down b1: 0/1 = -/Frame signal from SYNC card is down b4: 0/1 = -/Internal OSC clock down

NDA-24307 CHAPTER 3 Page 85 Issue 1 SYSTEM MESSAGES This message displays when a fault of the speech path system has occurred in a specific Module Group. The specific Module Group is placed into make-busy state. ➀ MG number of fault detection ➁ The kind of failure ➂ Speech Path/Clock System See Chapter 4 for the Circuit Card Replacement Procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 Default Alarm: MJ1-SModule Group Down FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = Even-numbered MG/Odd-numbered MG b0-b7: 00H/01H = -/ACT-side TSW fault b0: ACT side speech path 0/1 = No. 0 system/No. 1 system b1: ACT side clock 0/1 = No. 0 system/No. 1 system

CHAPTER 3 NDA-24307 Pag e 8 6 Issue 1 SYSTEM MESSAGES This message displays when the changeover of the TSW system is executed. ➀ACT side Speech Path (TSW) after changeover ➁ Reason for changeover 1: XXXX 0000 XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 XXXX XXXX ➀ ➁ ➂ ➃ ➄ ➅ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON1-TTSW ACT Change ReportDefault Grade: 2Grade Modified: Lamp Modified: 192122 b0: 0/1 = No. 0 system/No. 1 system b7-b4b3-b0CARDCONTENTS 01TSWI/O Alarm 2 32 ch Clock down, FH down 3 24 ch Clock down, FH down 6 TSW SW Memory write failure 9 I/O Alarm release 10 32 ch Clock down recovered, FH down recovered 11 24 ch Clock down recovered, FH down recovered 13 TSW MBR key OFF 15 TSW ACT/STBY changeover by the CMODI command 6 1 MUX MUX circuit card Ready failure 2 MUX circuit card Clock failure 20

NDA-24307 CHAPTER 3 Page 87 Issue 1 SYSTEM MESSAGES ➂~➅ Status of ACT side TSW card ~ Status of STBY side TSW card b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0-b3, b4-b7: The status of TSW card in each MG (00~07) 0000 = Normal 0001 = Abnormal (Impossible to make links) ➂MG00 MG01 ➃MG02 MG03 ➄MG04 MG05 ➅MG06 MG07 b7-b4 b3-b0 b0-b3, b4-b7: The status of TSW card in each MG (00~07) 0000 = Normal 0001 = Abnormal (Impossible to make links) MG00 MG01 MG02 MG03 MG04 MG05 MG06 MG07 b7-b4 b3-b019 20 21 22 1922

CHAPTER 3 NDA-24307 Pag e 8 8 Issue 1 SYSTEM MESSAGES This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more than 16 times an hour. At this time, the faulty DLKC card is shut and its switching network automatically changes over. ➀ System status of faulty DLKC card ➁ Error Code ➂ Details on Switching Network 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 Default Alarm: MN1-UDLKC Data Transfer Failure (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system / No. 1 system 01H: Firmware fault 02H: Data transfer time out to DLKC 03H: No answer time out (at DLKC) 04H: Data parity error b0: Status of Speech Path System (including DLKC) 0/1 = No. 0 system is ACT/No. 1 system is ACT b1: Status of basic clock 0/1 = No. 0 system is ACT/No. 1 system is ACT

NDA-24307 CHAPTER 3 Page 89 Issue 1 SYSTEM MESSAGES This message displays when a data sending error or no answer error occurs at the time of data transfer from CPU to DLKC card. ➀ System status of faulty DLKC card ➁ Error Code ➂ Details on Switching Network Note:This data displays when the STBY DLKC card is detected as faulty. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b1 b0 Default Alarm: SUP1-VDLKC Data Transfer Failure (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system / No. 1 system 01H: Firmware fault 02H: Data transfer time out to DLKC 03H: No answer time out (at DLKC) 04H: Data parity error b0: Status of Speech Path System (including DLKC) 0/1 = No. 0 system is ACT/No. 1 system is ACT b1: Status of basic clock 0/1 = No. 0 system is ACT/No. 1 system is ACT b7: Information on Reset of STBY DLKC Note 0/1 = - /STBY DLKC card was reset

CHAPTER 3 NDA-24307 Pag e 9 0 Issue 1 SYSTEM MESSAGES This message displays when a PLO/CLK-related failure, such as internal clock down is restored. ➀ Restoration of PLO fault ➁ Current status of PLO card ➂ Current status of the PLO card Note 1:The status includes that of PH-CK18 (CLK) card. Note 2:This information includes the failure detected in PH-CK18 (CLK) card. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4 b1 b0 Default Alarm: NON1-WPLO RestoreDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = PLO No. 0 system/PLO No. 1 system b0: 0/1 = Clock is in STBY side/ACT side Note 1 b1: 0/1 = PLO synchronizing/PLO self running or drifting b2: 0/1 = -/Input clock down b3, b4: Route of input clock (see the table below) b5: 0/1 = -/PLO input all down b6: 0/1 = -/PLO output down Note 2 b7: 0/1 = -/Drifting b4b3Connected With Primary Oscillator (M-OSC)Connected With External Clock 0 0 No. 0 M-OSC Route 0 0 1 No. 1 M-OSC Route 1 10–Route 2 11–Route 3 b0: 0/1 = -/5msec clock down b1: 0/1 = -/Frame Synchronization from SYNC card is down b4: 0/1 = -/Internal OSC clock down

NDA-24307 CHAPTER 3 Page 91 Issue 1 SYSTEM MESSAGES This message (for the ISW only) displays when a TSW card (one of the dual systems) of ISW fails to receive the CLK/FH signals, sent from the LN side. ➀ TSW detected as faulty ➁,➂ Details on the fault (TSW No. 0 side) ➁ ➂ Note 1:This data is displayed when b0 of ➀ is set as “1.” Note 2:For more information on each lamp, refer to the “Circuit Card Manual.” 1: XX00 XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00 b7 b6 b5 b4 b3 b2 b1 b0 LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200 Default Alarm: NON1-XLN → →→ → ISW CLK/FH Failure Default Grade: 0Grade Modified: Lamp Modified: b0: 0/1 = -/No. 0 system b1: 0/1 = -/No. 1 system The bits here correspond to “LN00” through “LN33” lamps, apiece, on a TSW (PU-SW00) card of No. 0 system. If “1” is set, the corresponding PCM traffic has encountered a CLK/FH failure. 0: - 1: LN → ISW CLK/FH Failure

CHAPTER 3 NDA-24307 Pag e 9 2 Issue 1 SYSTEM MESSAGES ➃,➄ Details on the fault (TSW 1 side) ➃ ➄ Note 1:This data is displayed when b1 of ➀ is set as “1.” Note 2:For more information on each lamp, refer to the “Circuit Card Manual.” b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 LN13 LN12 LN11 LN10 LN03 LN02 LN01 LN00 b7 b6 b5 b4 b3 b2 b1 b0 LN33 LN32 LN31 LN30 LN23 LN22 LN21 L200 The bits here correspond to “LN00” through “LN33” lamps, apiece, on a TSW (PU-SW00) card of No. 1 system. If “1” is set, the corresponding PCM traffic, once detected as faulty, has recovered. 0: - 1: LN → ISW CLK/FH Failure