NDA-24307 CHAPTER 3 Page 53 Issue 1 SYSTEM MESSAGES 6-M Emergency Control Stop 129 6-N Abnormal Call Duration Data 130 6-O SMDR Output Buffer Overflow Alarm 133 6-P SMDR Output Buffer Overflow Release 136 7-A System Initialize With Data Load 137 7-B System Initialize 139 7-C CPU MBR Key Turn ON 140 7-D CPU MBR Key Turn OFF 141 7-E TSW MBR Key Turn ON 142 7-F TSW MBR Key Turn OFF 143 7-I ALMC MB Key Turn ON 144 7-J ALMC MB Key Turn OFF 145 7-K PM MB Key Turn ON 146 7-L PM MB Key Turn OFF 147 7-M NCU MB Key Turn ON 148 7-N NCU MB Key Turn OFF 149 7-O Cyclic Diagnosis Normal 150 7-P Cyclic Diagnosis Information (Error Detected) 160 7-U PLO MB Key Turn ON 180 7-V PLO MB Key Turn OFF 181 13-A CCH Clock Failure 183 13-B CCH C-Level Infinite Loop Failure (Permanent) 184 13-C CCH C-Level Infinite Loop Failure (Temporary) 185 13-D CCH Lock-Up Failure (Permanent) 186 13-E CCH Lock-Up Failure (Temporary) 187 13-F CCH B-Level Infinite Loop Failure (Permanent) 188 13-G CCH B-Level Infinite Loop Failure (Temporary) 189 13-H CCS Link Failure (Permanent) 190 13-I CCS Link Failure (Temporary) 192 13-J Restoration From CCS Link Failure 194 13-K CCH Reset Interrupt Failure 195 13-N Digital Line Warning 196 13-O Digital Line Failure 197Table 3-1 List of System Messages (Continued) MESSAGE NO. SYSTEM MESSAGE PAGE

CHAPTER 3 NDA-24307 Pag e 5 4 Issue 1 SYSTEM MESSAGES 13-P Digital Line Restore 198 13-Q DAU Battery Operation 199 13-R DAU Line Operation 200 13-Z Power Failure 201 15-A VPS Failure (Temporary) 202 15-B VPS Failure (Permanent) 203 15-C VPS Restore 204 16-A Inside Trunk All Busy 205 16-B Virtual Tie Line Set Report 207 16-C Virtual Tie Line Cancel Report 208 16-E Virtual Tie Line Set Time Out 209 16-F Sender Start Time Out 212 16-K I/O Port Line OFF 219 16-L I/O Port Line Restore 220 16-M Hard Clock Failure 221 16-N Hard Clock Restore 222 16-T IOC Failure (Temporary) 223 16-U IOC Failure (Permanent) 224 16-X Station Exchanged Report 225 17-A CCH MBR Key Turn ON 228 17-B CCH MBR Key Turn OFF 229 17-C CCH MB Key Turn ON 230 17-D CCH MB Key Turn OFF 231 17-H Day/Night Change Information 232 17-O IOC MB Key Turn ON 234 17-P IOC MB Key Turn OFF 235 17-Q IOC MBR Key Turn ON 236 17-R IOC MBR Key Turn OFF237 17-Y GATE-HSW MBR Key ON238 17-Z GATE-HSW MBR Key OFF239 23-J ATM Interface Warning Note 2- 23-K ATM Interface Failure Note 2- 23-L ATM Interface Recovered Note 2- Table 3-1 List of System Messages (Continued) MESSAGE NO. SYSTEM MESSAGE PAGE

NDA-24307 CHAPTER 3 Page 55 Issue 1 SYSTEM MESSAGES Note 1: Refer to “Fusion Network System Manual.” Note 2:Refer to the manual related to ATM. Note 3:Refer to “Wireless System Manual.” Note 4:Refer to the manual related to OAI. 23-P Dch Back-Up Automatic Change Start/End 240 23-Q Dch Back-Up Manual Change Start/End242 23-R ATM Interface Change Report Note 2- 23-S FCCH Failure Note 1- 23-T FCCH Failure Recovered Note 1- 23-U FCCH Status Notice Note 1- 23-W FCCH Advancing Start Note 1- 23-X FCCH Advancing End Note 1- 23-Y MUX Clock Failure244 23-Z Both MUX Clock Failure245 25-J ZT Operation Start Note 3- 25-K ZT Set Up NG Note 3- 25-L ZT Fault Note 3- 25-M ZT Fault Recovery Note 3- 25-N ZT Carrier Fault Note 3- 26-N MAT Log246 26-R Call Trace247 26-V LAN Interface Error Report251 26-W LAN Interface Release Report255 27-C ATM Interface Port MB Key ON Note 2- 27-D ATM Interface Port MB Key OFF Note 2- 27-E DLMX MBR Key Turn ON257 27-F DLMX MBR Key Turn OFF258 27-G DLMX ACT Change Report259 33-A MUX Clock Restore260 33-B SDT Alarm Warning261 33-C SDT Alarm Trouble263 33-D SDT Alarm Restore266 33-E SDT Interface Change Notify267 Table 3-1 List of System Messages (Continued) MESSAGE NO. SYSTEM MESSAGE PAGE

CHAPTER 3 NDA-24307 Pag e 5 6 Issue 1 SYSTEM MESSAGES This message displays when the processor is reset due to a failure in the system. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information (FF H: not mounted) ➂ Related-call Release Result See Chapter 5 for repair procedure. 1: XXXX XX00 XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b4 b3 b1 b0 b7 b6 b4 b3 b1 b0 b7 Default Alarm: MN0-CReset InterruptDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b1: 0/1 = -Phase 1 Restart Note 1 b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart executed (for Dual-CPU system only) b6: 0/1 = Program Load not executed/executed b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b1: 0/1 = -Phase 1 Restart Note 1 b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart executed (for Dual-CPU system only) b6: 0/1 = Program Load not executed/executed b7: 0/1 = ACT/STBY (active system indication after restart) b7: 0/1 = Call Release Processing after restart → “Normal End”/ “Abnormal End”

NDA-24307 CHAPTER 3 Page 57 Issue 1 SYSTEM MESSAGES ➃Data Load Result after restart processing Note 1:Phase 1 Restart is executed when initializing the system without disrupting the following two-way connections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link For more details, see Chapter 6, Section 12. Note 2:The number sharing data load also affects the data load of Dual Station Calling Over-FCCS. b7 b6 b5 b4 b3 b2 b1 b0 b11b9 b8 b0: 0/1 = Office Data Load → “Normal End”/“Abnormal End” b1: 0/1 = Call Fowarding Data Load → “Normal End”/“Abnormal End” b2: 0/1 = Individual Speed Calling data load → “Normal End”/“Abnormal End” b3: 0/1 = RCF Data Load → “Normal End”/“Abnormal End” b4: 0/1 = Name Display Data Load → “Normal End”/“Abnormal End” b5: 0/1 = Network DM Load → “Normal End”/“Abnormal End” b6: 0/1 = Local DM Load → “Normal End”/“Abnormal End” b7: 0/1 = DM Load/Non Load b8: 0/1 = User Assign Soft Key data load → “Normal End”/“Abnormal End” b9: 0/1 = Number Sharing data load is “Normal End”/“Abnormal End” Note 2 b11: 0/1 = Call Block data load is “Normal End”/“Abnormal End”

CHAPTER 3 NDA-24307 Pag e 5 8 Issue 1 SYSTEM MESSAGES This message displays when a fault has occurred to the clock oscillator in the CPU. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information (FF H: not mounted) ➂ Related Call Information See Chapter 5 for repair procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b7 Default Alarm: MN0-DCPU Clock DownDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1=-/Monitor Restart b3: 0/1=-/Initialization b4: 0/1=-/Data Copy restart (for Dual-CPU system only) b5: 0/1=-/MB control b7: 0/1=ACT/STBY (active system indication after restart) b0: 0/1=-/Monitor Restart b3: 0/1=-/Initialization b4: 0/1=-/Data Copy restart (for Dual-CPU system only) b5: 0/1=-/MB control b7: 0/1=ACT/STBY (active system indication after restart) b7: 0/1=Released/Not released

NDA-24307 CHAPTER 3 Page 59 Issue 1 SYSTEM MESSAGES C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in an infinite loop. This message displays when the counter value to check the normality of the processing has become abnormal. ➀ Self-CPU Restart Information after clock fault occurrence ➁ Mate-CPU Restart Information ➂ NMI Factor See Chapter 5 for repair procedure. 0-E C-level Infinite Loop 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃➄ ➅➆➇ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➇ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➇ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP0-EC-Level Infinite LoopDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Reset by Power On b1: 0/1 = -/Watchdog Timer timeout b2: 0/1 = ISAGT is mounted/ISGAT is not mounted b3: 0/1 = -/OSC clock interrupt on ISGAT b4: 0/1 = -/IO parity Alarm b5: 0/1 = -/IO ready Alarm b6: 0/1 = -/External NMI

CHAPTER 3 NDA-24307 Pag e 6 0 Issue 1 SYSTEM MESSAGES ➃ System Controlling Port B ➄ CPU Alarm ➅ CPU Changeover Factors ➆ System ALM ➇ Data to be Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0: 0/1 = Timer 2 Gate ON/OFF b1: 0/1 = Speaker Gate ON/OFF b2: 0/1 = Parity Check Enable/MASK b3: 0/1 = Channel Check Enable/MASK b4: 0/1 = -/RAM Refresh Pulse Output State b5: 0/1 = -/Timer 2 Output State b6: 0/1 = -/Channel Check Error Detected b7: 0/1 = -/Parity Error Detected b0: 0/1 = -/ACT-side Processor CLK Alarm b1: 0/1 = -/ACT-side Processor COP Alarm b2: 0/1 = -/ACT-side Processor MEM Alarm b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow b4: 0/1 = -/STBY-side Processor CLK Alarm b5: 0/1 = -/STBY-side Processor COP Alarm b6: 0/1 = -/STBY-side Processor MEM Alarm b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow b0: 0/1 = -/CLK Alarm b1: 0/1 = -/Emergency Timer Overflow b2: 0/1 = -/SOFT EMA b3: 0/1 = -/SOFT changeover b4: 0/1 = -/Emergency Counter Overflow b5: 0/1 = STBY/ACT b6: 0/1 = Dual/Single b7: 0/1 = CPU 0/CPU 1 b0: 0/1 = -/Main Power Alarm b1: 0/1 = -/Power Alarm b2: 0/1 = -/FUSE Alarm b3: 0/1 = -/TEMP MJ Alarm b4: 0/1 = -/TEMP MN Alarm b5: 0/1 = -/Parity Alarm b6: 0/1 = Card is not mounted/mounted b7: 0/1 = -/EMA CLK Alarm

NDA-24307 CHAPTER 3 Page 61 Issue 1 SYSTEM MESSAGES This message displays when a CPU memory read/write error occurs. ➀Information on Self-CPU Restart after detection of a clock fault ➁ Mate-CPU Restart Information ➂ NMI Factor See Chapter 5 for repair procedure. 0-F Memory Failure 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ 4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX ➇ 7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000 ➇ b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP0-FMemory FailureDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Monitor Restart b3: 0/1 = -/Initialization b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only) b5: 0/1 = -/MB control b7: 0/1 = ACT/STBY (active system indication after restart) b0: 0/1 = -/Reset by Power On b1: 0/1 = -/Watchdog Timer timeout b2: 0/1 = ISGAT is mounted/ISGAT is not mounted b3: 0/1 = -/OSC clock interrupt on ISGAT b4: 0/1 = -/IO parity Alarm b5: 0/1 = -/IO ready Alarm b6: 0/1 = -/External NMI

CHAPTER 3 NDA-24307 Pag e 6 2 Issue 1 SYSTEM MESSAGES ➃ System Controlling Port B ➄ CPU Alarm ➅ CPU Changeover Factors ➆ System ALM ➇ Data to be Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0: 0/1 = Timer 2 Gate ON/OFF b1: 0/1 = Speaker Gate ON/OFF b2: 0/1 = Parity Check Enable/MASK b3: 0/1 = Channel Check Enable/MASK b4: 0/1 = -/RAM Refresh Pulse Output State b5: 0/1 = -/Timer 2 Output State b6: 0/1 = -/Channel Check Error Detected b7: 0/1 = -/Parity Error Detected b0: 0/1 = -/ACT-side Processor CLK Alarm b1: 0/1 = -/ACT-side Processor COP Alarm b2: 0/1 = -/ACT-side Processor MEM Alarm b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow b4: 0/1 = -/STBY-side Processor CLK Alarm b5: 0/1 = -/STBY-side Processor COP Alarm b6: 0/1 = -/STBY-side Processor MEM Alarm b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow b0: 0/1 = -/CLK Alarm b1: 0/1 = -/Emergency Timer Overflow b2: 0/1 = -/SOFT EMA b3: 0/1 = -/SOFT changeover b4: 0/1 = -/Emergency Counter Overflow b5: 0/1 = STBY/ACT b6: 0/1 = Dual/Single b7: 0/1 = CPU 0/CPU 1 b0: 0/1 = -/Main Power Alarm b1: 0/1 = -/Power Alarm b2: 0/1 = -/FUSE Alarm b3: 0/1 = -/TEMP MJ Alarm b4: 0/1 = -/TEMP MN Alarm b5: 0/1 = -/Parity Alarm b6: 0/1 = Card is not mounted/mounted b7: 0/1 = -/EMA CLK Alarm