    							NDA-24307 CHAPTER 3
    Page 53
    Issue 1
    SYSTEM MESSAGES
    6-M Emergency Control Stop 129
    6-N Abnormal Call Duration Data 130
    6-O SMDR Output Buffer Overflow Alarm 133
    6-P SMDR Output Buffer Overflow Release 136
    7-A System Initialize With Data Load 137
    7-B System Initialize 139
    7-C CPU MBR Key Turn ON 140
    7-D CPU MBR Key Turn OFF 141
    7-E TSW MBR Key Turn ON 142
    7-F TSW MBR Key Turn OFF 143
    7-I ALMC MB Key Turn ON 144
    7-J ALMC MB Key Turn OFF 145
    7-K PM MB Key Turn ON 146
    7-L PM MB Key Turn OFF 147
    7-M NCU MB Key Turn ON 148
    7-N NCU MB Key Turn OFF 149
    7-O Cyclic Diagnosis Normal 150
    7-P Cyclic Diagnosis Information (Error Detected) 160
    7-U PLO MB Key Turn ON 180
    7-V PLO MB Key Turn OFF 181
    13-A CCH Clock Failure 183
    13-B CCH C-Level Infinite Loop Failure (Permanent) 184
    13-C CCH C-Level Infinite Loop Failure (Temporary) 185
    13-D CCH Lock-Up Failure (Permanent) 186
    13-E CCH Lock-Up Failure (Temporary) 187
    13-F CCH B-Level Infinite Loop Failure (Permanent) 188
    13-G CCH B-Level Infinite Loop Failure (Temporary) 189
    13-H CCS Link Failure (Permanent) 190
    13-I CCS Link Failure (Temporary) 192
    13-J Restoration From CCS Link Failure 194
    13-K CCH Reset Interrupt Failure 195
    13-N Digital Line Warning 196
    13-O Digital Line Failure 197Table 3-1  List of System Messages  (Continued)
    MESSAGE NO.  SYSTEM MESSAGE PAGE 
    						
    							CHAPTER 3 NDA-24307
    Pag e 5 4
    Issue 1
    SYSTEM MESSAGES
    13-P Digital Line Restore 198
    13-Q DAU Battery Operation 199
    13-R DAU Line Operation 200
    13-Z Power Failure 201
    15-A VPS Failure (Temporary) 202
    15-B VPS Failure (Permanent) 203
    15-C VPS Restore 204
    16-A Inside Trunk All Busy 205
    16-B Virtual Tie Line Set Report 207
    16-C Virtual Tie Line Cancel Report 208
    16-E Virtual Tie Line Set Time Out 209
    16-F Sender Start Time Out 212
    16-K I/O Port Line OFF 219
    16-L I/O Port Line Restore 220
    16-M Hard Clock Failure 221
    16-N Hard Clock Restore 222
    16-T IOC Failure (Temporary) 223
    16-U IOC Failure (Permanent) 224
    16-X Station Exchanged Report 225
    17-A CCH MBR Key Turn ON 228
    17-B CCH MBR Key Turn OFF 229
    17-C CCH MB Key Turn ON 230
    17-D CCH MB Key Turn OFF 231
    17-H Day/Night Change Information 232
    17-O IOC MB Key Turn ON 234
    17-P IOC MB Key Turn OFF 235
    17-Q IOC MBR Key Turn ON 236
    17-R IOC MBR Key Turn OFF237
    17-Y GATE-HSW MBR Key ON238
    17-Z GATE-HSW MBR Key OFF239
    23-J ATM Interface Warning Note 2-
    23-K ATM Interface Failure Note 2-
    23-L ATM Interface Recovered Note 2- Table 3-1  List of System Messages  (Continued)
    MESSAGE NO.  SYSTEM MESSAGE PAGE 
    						
    							NDA-24307 CHAPTER 3
    Page 55
    Issue 1
    SYSTEM MESSAGES
    Note 1:
    Refer to “Fusion Network System Manual.”
    Note 2:Refer to the manual related to ATM.
    Note 3:Refer to “Wireless System Manual.”
    Note 4:Refer to the manual related to OAI. 23-P Dch Back-Up Automatic Change Start/End
    240
    23-Q Dch Back-Up Manual Change Start/End242
    23-R ATM Interface Change Report Note 2-
    23-S FCCH Failure Note 1-
    23-T FCCH Failure Recovered Note 1-
    23-U FCCH Status Notice Note 1-
    23-W FCCH Advancing Start Note 1-
    23-X FCCH Advancing End Note 1-
    23-Y MUX Clock Failure244
    23-Z Both MUX Clock Failure245
    25-J ZT Operation Start Note 3-
    25-K ZT Set Up NG Note 3-
    25-L ZT Fault Note 3-
    25-M ZT Fault Recovery Note 3-
    25-N ZT Carrier Fault Note 3-
    26-N MAT Log246
    26-R Call Trace247
    26-V LAN Interface Error Report251
    26-W LAN Interface Release Report255
    27-C ATM Interface Port MB Key ON Note 2-
    27-D ATM Interface Port MB Key OFF Note 2-
    27-E DLMX MBR Key Turn ON257
    27-F DLMX MBR Key Turn OFF258
    27-G DLMX ACT Change Report259
    33-A MUX Clock Restore260
    33-B SDT Alarm Warning261
    33-C SDT Alarm Trouble263
    33-D SDT Alarm Restore266
    33-E SDT Interface Change Notify267 Table 3-1  List of System Messages  (Continued)
    MESSAGE NO.  SYSTEM MESSAGE PAGE 
    						
    							CHAPTER 3 NDA-24307
    Pag e 5 6
    Issue 1
    SYSTEM MESSAGES
    This message displays when the processor is reset due to a failure in the system.
    ➀ Self-CPU Restart Information
    ➁ Mate-CPU Restart Information (FF 
    H: not mounted)
    ➂ Related-call Release Result
    See Chapter 5 for repair procedure.
    1: XXXX XX00 XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b4 b3 b1 b0
    b7 b6 b4 b3 b1 b0
    b7
    Default Alarm:
    MN0-CReset InterruptDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b1: 0/1 = -Phase 1 Restart Note 1
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart executed (for Dual-CPU system only)
    b6: 0/1 = Program Load not executed/executed
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b1: 0/1 = -Phase 1 Restart Note 1
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart executed (for Dual-CPU system only)
    b6: 0/1 = Program Load not executed/executed
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b7: 0/1 = Call Release Processing after restart 
    → “Normal End”/
    “Abnormal End” 
    						
    							NDA-24307 CHAPTER 3
    Page 57
    Issue 1
    SYSTEM MESSAGES
    ➃Data Load Result after restart 
    processing
    Note 1:Phase 1 Restart is executed when initializing the system without disrupting the following two-way
    connections that have already been established:
    Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
    Fixed connections
    Two-way connections established on a Fusion link
    For more details, see Chapter 6, Section 12.
    Note 2:The number sharing data load also affects the data load of Dual Station Calling Over-FCCS. b7 b6 b5 b4 b3 b2 b1 b0
    b11b9 b8
    b0: 0/1 = Office Data Load → “Normal End”/“Abnormal End”
    b1: 0/1 = Call Fowarding Data Load 
    → “Normal End”/“Abnormal End”
    b2: 0/1 = Individual Speed Calling data load 
    → “Normal End”/“Abnormal 
    End”
    b3: 0/1 = RCF Data Load 
    → “Normal End”/“Abnormal End”
    b4: 0/1 = Name Display Data Load 
    → “Normal End”/“Abnormal End”
    b5: 0/1 = Network DM Load 
    → “Normal End”/“Abnormal End”
    b6: 0/1 = Local DM Load 
    → “Normal End”/“Abnormal End”
    b7: 0/1 = DM Load/Non Load
    b8: 0/1 = User Assign Soft Key data load 
    → “Normal End”/“Abnormal 
    End” 
    b9: 0/1 = Number Sharing data load is “Normal End”/“Abnormal End”
    Note 2
    b11: 0/1 = Call Block data load is “Normal End”/“Abnormal End” 
    						
    							CHAPTER 3 NDA-24307
    Pag e 5 8
    Issue 1
    SYSTEM MESSAGES
    This message displays when a fault has occurred to the clock oscillator in the CPU.
    ➀ Self-CPU Restart Information
    ➁ Mate-CPU Restart Information (FF 
    H: not mounted)
    ➂ Related Call Information
    See Chapter 5 for repair procedure.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b7
    Default Alarm:
    MN0-DCPU Clock DownDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1=-/Monitor Restart
    b3: 0/1=-/Initialization
    b4: 0/1=-/Data Copy restart (for Dual-CPU system only)
    b5: 0/1=-/MB control
    b7: 0/1=ACT/STBY (active system indication after restart)
    b0: 0/1=-/Monitor Restart
    b3: 0/1=-/Initialization
    b4: 0/1=-/Data Copy restart (for Dual-CPU system only)
    b5: 0/1=-/MB control
    b7: 0/1=ACT/STBY (active system indication after restart)
    b7: 0/1=Released/Not released 
    						
    							NDA-24307 CHAPTER 3
    Page 59
    Issue 1
    SYSTEM MESSAGES
    C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in
    an infinite loop. This message displays when the counter value to check the normality of the processing has
    become abnormal.
    ➀ Self-CPU Restart Information after 
    clock fault occurrence
    ➁ Mate-CPU Restart Information
    ➂ NMI Factor
    See Chapter 5 for repair procedure.
    0-E C-level Infinite Loop
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
     
    ➀ ➁
    ➂ 
    ➃➄ 
    ➅➆➇
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➇
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➇
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP0-EC-Level Infinite LoopDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Reset by Power On
    b1: 0/1 = -/Watchdog Timer timeout
    b2: 0/1 = ISAGT is mounted/ISGAT is not mounted
    b3: 0/1 = -/OSC clock interrupt on ISGAT
    b4: 0/1 = -/IO parity Alarm
    b5: 0/1 = -/IO ready Alarm
    b6: 0/1 = -/External NMI 
    						
    							CHAPTER 3 NDA-24307
    Pag e 6 0
    Issue 1
    SYSTEM MESSAGES
    ➃ System Controlling Port B
    ➄ CPU Alarm
    ➅ CPU Changeover Factors
    ➆ System ALM
    ➇ Data to be Analyzed by NEC 
    Engineers b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0: 0/1 = Timer 2 Gate ON/OFF
    b1: 0/1 = Speaker Gate ON/OFF
    b2: 0/1 = Parity Check Enable/MASK
    b3: 0/1 = Channel Check Enable/MASK
    b4: 0/1 = -/RAM Refresh Pulse Output State
    b5: 0/1 = -/Timer 2 Output State
    b6: 0/1 = -/Channel Check Error Detected
    b7: 0/1 = -/Parity Error Detected
    b0: 0/1 = -/ACT-side Processor CLK Alarm
    b1: 0/1 = -/ACT-side Processor COP Alarm
    b2: 0/1 = -/ACT-side Processor MEM Alarm
    b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow
    b4: 0/1 = -/STBY-side Processor CLK Alarm
    b5: 0/1 = -/STBY-side Processor COP Alarm
    b6: 0/1 = -/STBY-side Processor MEM Alarm
    b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow
    b0: 0/1 = -/CLK Alarm
    b1: 0/1 = -/Emergency Timer Overflow
    b2: 0/1 = -/SOFT EMA
    b3: 0/1 = -/SOFT changeover
    b4: 0/1 = -/Emergency Counter Overflow
    b5: 0/1 = STBY/ACT
    b6: 0/1 = Dual/Single
    b7: 0/1 = CPU 0/CPU 1
    b0: 0/1 = -/Main Power Alarm
    b1: 0/1 = -/Power Alarm
    b2: 0/1 = -/FUSE Alarm
    b3: 0/1 = -/TEMP MJ Alarm
    b4: 0/1 = -/TEMP MN Alarm
    b5: 0/1 = -/Parity Alarm
    b6: 0/1 = Card is not mounted/mounted
    b7: 0/1 = -/EMA CLK Alarm 
    						
    							NDA-24307 CHAPTER 3
    Page 61
    Issue 1
    SYSTEM MESSAGES
    This message displays when a CPU memory read/write error occurs.
    ➀Information on Self-CPU Restart 
    after detection of a clock fault
    ➁ Mate-CPU Restart Information
    ➂ NMI Factor
    See Chapter 5 for repair procedure.
    0-F Memory Failure
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
     
    ➀ ➁
    ➂ ➃
    ➄ ➅
    ➆
    ➇
    4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
    ➇
    7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
    ➇
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP0-FMemory FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Reset by Power On
    b1: 0/1 = -/Watchdog Timer timeout
    b2: 0/1 = ISGAT is mounted/ISGAT is not mounted
    b3: 0/1 = -/OSC clock interrupt on ISGAT
    b4: 0/1 = -/IO parity Alarm
    b5: 0/1 = -/IO ready Alarm
    b6: 0/1 = -/External NMI 
    						
    							CHAPTER 3 NDA-24307
    Pag e 6 2
    Issue 1
    SYSTEM MESSAGES
    ➃ System Controlling Port B
    ➄ CPU Alarm
    ➅ CPU Changeover Factors
    ➆ System ALM
    ➇ Data to be Analyzed by NEC 
    Engineers b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0: 0/1 = Timer 2 Gate ON/OFF
    b1: 0/1 = Speaker Gate ON/OFF
    b2: 0/1 = Parity Check Enable/MASK
    b3: 0/1 = Channel Check Enable/MASK
    b4: 0/1 = -/RAM Refresh Pulse Output State
    b5: 0/1 = -/Timer 2 Output State
    b6: 0/1 = -/Channel Check Error Detected
    b7: 0/1 = -/Parity Error Detected
    b0: 0/1 = -/ACT-side Processor CLK Alarm
    b1: 0/1 = -/ACT-side Processor COP Alarm
    b2: 0/1 = -/ACT-side Processor MEM Alarm
    b3: 0/1 = -/ACT-side Processor Emergency Timer Overflow
    b4: 0/1 = -/STBY-side Processor CLK Alarm
    b5: 0/1 = -/STBY-side Processor COP Alarm
    b6: 0/1 = -/STBY-side Processor MEM Alarm
    b7: 0/1 = -/STBY-side Processor Emergency Timer Overflow
    b0: 0/1 = -/CLK Alarm
    b1: 0/1 = -/Emergency Timer Overflow
    b2: 0/1 = -/SOFT EMA
    b3: 0/1 = -/SOFT changeover
    b4: 0/1 = -/Emergency Counter Overflow
    b5: 0/1 = STBY/ACT
    b6: 0/1 = Dual/Single
    b7: 0/1 = CPU 0/CPU 1
    b0: 0/1 = -/Main Power Alarm
    b1: 0/1 = -/Power Alarm
    b2: 0/1 = -/FUSE Alarm
    b3: 0/1 = -/TEMP MJ Alarm
    b4: 0/1 = -/TEMP MN Alarm
    b5: 0/1 = -/Parity Alarm
    b6: 0/1 = Card is not mounted/mounted
    b7: 0/1 = -/EMA CLK Alarm 
    						