CHAPTER 5 NDA-24301 Pag e 2 94 Revision 1.0 2. COMMANDS FOR OPERATION AND MAINTENANCE [Contents of Command Description] Each command is explained dividing into the following parts. Command Name Explained here are the command names to be entered via the keyboard and its full command names. General General functions of each command are explained. Precaution Cautions to be made when using each command are explained. Parameters Parameters (data) assigned by each command are shown. How to Use Usage of each command is explained. Related Commands Related commands are shown.

NDA-24301 CHAPTER 5 Page 295 Revision 1.0 ATRF : Assignment of Traffic Measurement Order 1. GENERAL This command is used to assign and delete traffic measurement programs. A request for traffic measurement is performed when a traffic measurement instruction has been assigned by this command. The collected traffic measurement data can be output from the MAT printer or stored on the HD of the MAT, which can be designated on the basis of traffic measurement type. 2. PRECAUTIONS None 3. PARAMETERS Input Data TYPE : Type of Traffic Measurement (1-16) Note:Refer to the “Operation & Maintenance Manual” for information about this data. PORT : Traffic Information Output Terminal Number (0-7) INTERVAL : Output interval (0-120) Interval must be assigned in 10 minute increments or 0 can be assigned which will require that an output time is assigned to “OUTPUT HOUR/ MINUTE”. START HOUR START MINUTE END HOUR END MINUTE OUTPUT HOUR :This data is valid only when “INTERVAL” = 0. OUTPUT MINUTE :This data is valid only when “INTERVAL” = 0. SRT : Start External Route Number ERT : End External Route Number DATA MEANING DATA MEANING 1~16Note 17 ZT peg count

CHAPTER 5 NDA-24301 Pag e 2 96 Revision 1.0 AZARL : Assignment of ZT Area Information for Local Data Memory 1. GENERAL This command is used to assign and delete the Zone Transceiver Area information in the Local Node (LN). 2. PRECAUTIONS 1. This command is used for the Local Node. 2. All PSs data must be re-download, if control carrier data is changed via this command. 3. The parameters, WTZNSL, WTZNKL, RCHOOL, RCHOSL, RCHFE, CCHGFE, should not be changed from default setting. 4. ZT must be restarted after using this command. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ZSL (ZONE SELECT LEVEL) : 0-255 ZKL (ZONE KEEP LEVEL) : 0-255 HOL (HAND-OVER OPERATION LEVEL) : 0-255 HSL (HAND-OVER SELECT LEVEL) : 0-255 HFT (HAND-OVER FOR THRESHOLD) : 0-255 CCFT (CHANNEL CHANGE FOR THRESHOLD) : 0-255 NCCR (NUMBER OF CONTROL CARRIER) : 0-5 CCR 1-5 (CONTROL CARRIER 1-5) : 0-20 If this is not assigned, the default setting is below. ZSL = 67 (33dB µ V) ZKL = 56 (22dB µ V) HOL = 59 (25dB µ V) HSL = 67 (33dB µ V) HFT = 10 frame error/240 frame (1.2 sec) (This is effective for mode2 ZT.) CCFT = 24 frame error/240 frame (1.2 sec) NCCR = 3 CCR 1 = 2 Channel CCR 2 = 4 Channel CCR 3 = 6 Channel CCR 4 = 0 None CCR 5 = 0 None

NDA-24301 CHAPTER 5 Page 297 Revision 1.0 AZARN : Assignment of ZT Area Information for Network Data Memory 1. GENERAL This command is used to assign and delete the Zone Transceiver Area information in the Network Control Node (NCN). 2. PRECAUTIONS 1. This command is used for the Network Control Node. 2. All PSs data must be re-download, if control carrier data is changed via this command. 3. The parameters, WTZNSL, WTZNKL, RCHOOL, RCHOSL, RCHFE, CCHGFE, should not be changed from default setting. 4. ZT must be restarted after using this command. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ZSL (ZONE SELECT LEVEL) : 0-255 ZKL (ZONE KEEP LEVEL) : 0-255 HOL (HAND-OVER OPERATION LEVEL) : 0-255 HSL (HAND-OVER SELECT LEVEL) : 0-255 HFT (HAND-OVER FOR THRESHOLD) : 0-255 CCFT (CHANNEL CHANGE FOR THRESHOLD) : 0-255 NCCR (NUMBER OF CONTROL CARRIER) : 0-5 CCR 1-5 (CONTROL CARRIER 1-5) : 0-20 If this data is not assigned, the default setting is below. ZSL = 67 (33dB µ V) ZKL = 56 (22dB µ V) HOL = 59 (25dB µ V) HSL = 67 (33dB µ V) HFT = 10 frame error/240 frame (1.2 sec) (This is effective for mode 2 ZT.) CCFT = 24 frame error/240 frame (1.2 sec) NCCR = 3 CCR 1 = 2 Channel CCR 2 = 4 Channel CCR 3 = 6 Channel CCR 4 = 0 None CCR 5 = 0 None

CHAPTER 5 NDA-24301 Pag e 2 98 Revision 1.0 COCS1L : Control of CS/ZT Status Read for Local Data Memory 1. GENERAL This command is used to read the status of the CS/ZT in the Local Node (LN). 2. PRECAUTIONS This command is used for the Local Node. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 GRN (GROUP NUMBER) : 1-8 CSN (CS/ZT NUMBER) : 1-32 After the assignment data is processed between PBX and MAT; following parameter is automatically assigned LENS (EQUIPMENT NUMBER) : Line Equipment Number TN (TENANT NUMBER) : 1-6 CS-ID (CS/ZT-IDENTIFY) : CS/ZT-Identify MAIN (MAIN CONDITION OF CS/ZT : Main Condition of CS/ZT Management MANAGEMENT FOR DEVICE SIDE) For Device Side SUB (CONTROL CONDITION OF CS/ZT : Control Condition of CS/ZT Management MANAGEMENT FOR DEVICE SIDE) For Device Side CS/ZT TYPE (CS TYPE) : Control (Control CS/ZT) General (Control CS/ZT) CS STATUS (CS/ZT STATUS) : CS/ZT status (If parameter can be changed) NON-OP (Non Open) CLOSE (Close) OPERATE (Operating Now) LINK STATUS (DATA LINK STATUS) : Data Link Status (If parameter can be changed) UNLINK (Data Link Break) OPEN (Data Link Open) CLOSE (CS/ZT Fault After Return) FAULT (CS/ZT Fault) BCH B2 (B2CH STATUS) : B2ch Status (If parameter can be changed) IDLE (B2ch Idle) BUSY (B2ch Busy) CLOSE (B2ch Close) BCH B3 (B4CH STATUS) : B3ch Status (If parameter can be changed) IDLE (B3ch Idle) BUSY (B3ch Busy) CLOSE (B3ch Close) BCH B4 (B4CH STATUS) : B4ch Status (If parameter can be changed) IDLE (B4ch Idle) BUSY (B4ch Busy) CLOSE (B4ch Close) FLT (NG CAUSE) : 0-FF (Only Display) Only Display

NDA-24301 CHAPTER 5 Page 299 Revision 1.0 COCS1N : Control of CS/ZT Status Read for Network Data Memory 1. GENERAL This command is used to read the status of the CS/ZT status read in the Network Control Node (NCN). 2. PRECAUTIONS This command is used for the Network Control Node. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 GRN (GROUP NUMBER) : 1-8 CSN (CS/ZT NUMBER) : 1-32 After the assignment data is processed between PBX and MAT; following parameter is automatically assigned LENS (EQUIPMENT NUMBER) : Line Equipment Number TN (TENANT NUMBER) : 1-6 CS-ID (CS/ZT-IDENTIFY) : CS/ZT-Identify MAIN (MAIN CONDITION OF CS/ZT : Main Condition of CS/ZT Management MANAGEMENT FOR DEVICE SIDE) For Device Side SUB (CONTROL CONDITION OF CS/ZT : Control Condition of CS/ZT Management MANAGEMENT FOR DEVICE SIDE) For Device Side CS/ZT TYPE (CS TYPE) : Control (Control CS/ZT) General (Control CS/ZT) CS STATUS (CS/ZT STATUS) : CS/ZT status (If parameter can be changed) NON-OP (Non Open) CLOSE (Close) OPERATE (Operating Now) LINK STATUS (DATA LINK STATUS) : Data Link Status (If parameter can be changed) UNLINK (Data Link Break) OPEN (Data Link Open) CLOSE (CS/ZT Fault After Return) FAULT (CS/ZT Fault) BCH B2 (B2CH STATUS) : B2ch Status (If parameter can be changed) IDLE (B2ch Idle) BUSY (B2ch Busy) CLOSE (B2ch Close) BCH B3 (B4CH STATUS) : B3ch Status (If parameter can be changed) IDLE (B3ch Idle) BUSY (B3ch Busy) CLOSE (B3ch Close) BCH B4 (B4CH STATUS) : B4ch Status (If parameter can be changed) IDLE (B4ch Idle) BUSY (B4ch Busy) CLOSE (B4ch Close) FLT (NG CAUSE) : 0-FF (Only Display) Only Display

CHAPTER 5 NDA-24301 Pag e 3 00 Revision 1.0 COCS2L : Change of CS/ZT Operation Parameter for Local Data Memory 1. GENERAL This command is used to change the CS/ZT operation parameter in the Local Node (LN). 2. PRECAUTIONS This command is used for the Local Node. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 MODE (GLOBAL DEFINITION : 1: NOR (Normal) INFORMATION PATTERN NUMBER) 2: HBY (Heavy) ZONE (ZONE KIND) : 1: LG (Large) 2: SM (Small) PAS (POSITION ASSIGNMENT) : 1: SET 2: CANCEL

NDA-24301 CHAPTER 5 Page 301 Revision 1.0 COCS2N : Change of CS/ZT Operation Parameter for Network Data Memory 1. GENERAL This command is used to change the CS/ZT operation parameter in the Network Control Node (NCN). 2. PRECAUTIONS This command is used for the Network Data Node. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 MODE (GLOBAL DEFINITION : 1: NOR (Normal) INFORMATION PATTERN NUMBER) 2: HBY (Heavy) ZONE (ZONE KIND) : 1: LG (Large) 2: SM (Small) PAS (POSITION ASSIGNMENT) : 1: SET 2: CANCEL

CHAPTER 5 NDA-24301 Pag e 3 02 Revision 1.0 COCS3L : Change of CS/ZT Reset for Local Data Memory 1. GENERAL This command is used to control CS/ZT Reset for the Local Node (LN). 2. PRECAUTIONS This command is used for the Local Node. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 GRN (GROUP NUMBER) : 1-8 CSN (CS/ZT NUMBER) : 1-32 After the assignment data is processed between PBX and MAT; following parameter is automatically assigned TN (TENANT NUMBER) : 1-System Max. LENS (EQUIPMENT NUMBER) : LENS EQUIPMENT NUMBER FLT (NG CAUSE) : 0-FF (Only Display)

NDA-24301 CHAPTER 5 Page 303 Revision 1.0 COCS3N : Control of CS/ZT Reset for Network Data Memory 1. GENERAL This command is used to control CS/ZT Reset for the Local Node (LN). 2. PRECAUTIONS This command is used for the Network Control Node. 3. DATA ENTRY INSTRUCTIONS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 GRN (GROUP NUMBER) : 1-8 CSN (CS/ZT NUMBER) : 1-32 After the assignment data is processed between PBX and MAT; following parameters are automatically assigned TN (TENANT NUMBER) : 1-System Max. LENS (EQUIPMENT NUMBER) : LENS EQUIPMENT NUMBER FLT (NG CAUSE) : 0-FF (Only Display)