Step 2: Install the CD Loadin g P.C.B. as arrows shown. Step 3: The claw should be latched. Step 4: Fix it with 4 screws. Step 5: Solder the 4 points. 91 CRS1

7.2.5. Assembly of Traverse Unit Step 1: Turn over the unit and install the traverse unit. Step 2: Push the traverse slide plate as arrow shown to lock the traverse unit. 92 CRS1

8 CRS1 (Changer Unit) Ageing / Reliability Purpose: It is necessary totest the mechanism unit by using the Service Jig P.C.B., make sure itworks in order before install it to the main unit. 8.1. Equipments 93 CRS1

(All schematic diagrams may be modified at any timewith the develo pment of new technology) Note : SW1 Open switch SW2 Stock switch SW3 Home switch SW4 Top switch SW5 Play switch · The voltage value and waveforms are the reference voltage of this unit measured by DC electronic voltmeter (high impedance) and oscilloscope on the basis of chassis. Accordingly, there may arise some error in voltage values and waveforms depending upon the internal impedance of the tester or the measuring unit. · Importance safety notice : Components identified by mark have special characteristics important for safety. Furthermore, special parts which have purposes of fire-retardant (resistors), high- quality sound (capacitors), low-noise (resistors), etc. are used.Whenreplacing any of components, be sure to use onlymanufacturer´s specified parts shown in the parts list. Caution ! IC, LSI and VLSI are sensitive to static electricity. Secondary trouble can be prevented by taking care during repair. · Cover the parts boxes made of plastics with aluminium foil. · Put a conductive mat on the work table. · Ground the soldering iron. · Do not touch the pins of IC, LSI or VLSI with fingers directly . 9 Notes of Schematic Diagram 94 CRS1

10 Schematic Diagram 10.1. CD Loading Circuit ! ! # $% 95 CRS1

11 Printed Circuit Board 11.1. CD Loading P.C.B. ! # $ $% & 96 CRS1

12 Exploded Views 12.1. CD Loading Mechanism 97 CRS1

Notes: 13 Replacement Parts List · Important safety notice: Components identified by mark have special characteristics important for safety. Furthermore, special parts which have purposes of fire-retardant (resistors), high-quality sound (capacitors), low-noise (resistors), etc. are used. Whenreplacing any of these components, be sure to use onlymanufacturers’s specified parts shown in the parts list. · Capacitor values are in microfarad (µF) unless specified otherwise, P=Pico -farads(pF); Farads. · Resistance values are in ohms, unless specified otherwise, 1K=1,000(ohms). · The marking (RTL) indicates that the Retention Time is limited for this item. After the discontinuation of this assembly in production, the item will continue to be available for a specific period of time. The retention period of availability is dependant on the type of assembly, and in accordance with the laws governing part and product retention. After the end of this period, the assembly will no longer be available. · [M] Indicates in the Remarks columns indicates parts that are supplie d byPAVCSG. 100 CRS1