Home > Panasonic > Projector > Panasonic DLP Projector PT-DW640U PT-DW640UL PT-DX610U PT-DX610UL Operating Instructions

Panasonic DLP Projector PT-DW640U PT-DW640UL PT-DX610U PT-DX610UL Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic DLP Projector PT-DW640U PT-DW640UL PT-DX610U PT-DX610UL Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ENGLISH - 101
    Chapter 4 Settings — [NETWORK] menu
    [E-mail set up] page
    You can send E-mail to an E-mail address (maximum two addresses) set in advance when a problem occurs or the cumulative operating time 
    of a lamp reaches a set value.
    Click [Detailed set up]
     → [E-mail set up].
    (1)
    (2)
    (3)
    (4)
    (5)
    (6)
    1 
    [ENABLE]
    Select [Enable] to use the E-mail function.
    2  [SMTP SERVER NAME]
    Enter the IP address or the server name of the E-mail server 
    (SMTP). To enter the server name, the setup of the DNS server 
    is required.
    3  [MAIL FROM]
    Enter the E-mail address of the projector. (Up to 63 characters 
    in single byte) 4 
    [MEMO]
    You can enter information such as the location of the projector 
    that notifies the sender of the E-mail. (Up to 63 characters in 
    single byte)
    5  [MINIMUM TIME]
    Change the minimum interval for the temperature warning mail. 
    The default value is 60 minutes. In this case, another E-mail 
    will not be sent for 60 minutes after sending the temperature 
    warning mail even if it reaches the warning temperature.
    6  [INTAKE AIR TEMPERATURE]
    Change the temperature setting for the temperature warning 
    mail. A temperature warning mail is sent when the temperature 
    exceeds this value.
    (8)
    (7)
    7 [E-MAIL ADDRESS 1]
    Enter the E-mail address to be sent.
    8  Settings of the conditions to send E-mail
    Select the conditions to send E-mail.
    [MAIL CONTENTS]:
    Select either [NORMAL] or [SIMPLE].
    [ERROR]:
    An E-mail message is sent when an error occurred in the self-
    diagnosis.
    [LAMP1 RUNTIME]:
    An E-mail message is sent when the remaining lamp on time for 
    the lamp 1 has reached the value set at the right field.
    [LAMP2 RUNTIME]:
    An E-mail message is sent when the remaining lamp on time for 
    the lamp 2 has reached the value set at the right field.
    [INTAKE AIR TEMPERATURE]:
    An E-mail message is sent when the air intake temperature has 
    reached the value set at the above field. [PERIODIC REPORT]:
    Place a check mark on this when E-mail is to be sent 
    periodically.
    It will be sent on the days and time with the check mark.  
    						
    							102 - ENGLISH
    Chapter 4 Settings — [NETWORK] menu
    (11)
    (10)
    (9)
    9 [E-MAIL ADDRESS 2]
    Enter the E-mail address to be sent when two E-mail addresses 
    are to be used.
    Leave it blank when two E-mail addresses are not to be used.
    10  Settings of the conditions to send E-mail
    Select the conditions to send E-mail to the second E-mail 
    address.
    [MAIL CONTENTS]:
    Select either [NORMAL] or [SIMPLE].
    [ERROR]:
    An E-mail message is sent when an error occurred in the self-
    diagnosis.
    [LAMP1 RUNTIME]:
    An E-mail message is sent when the remaining lamp on time for 
    the lamp 1 has reached the value set at the right field. [LAMP2 RUNTIME]:
    An E-mail message is sent when the remaining lamp on time for 
    the lamp 2 has reached the value set at the right field.
    [INTAKE AIR TEMPERATURE]:
    An E-mail message is sent when the air intake temperature has 
    reached the value set at the above field.
    [PERIODIC REPORT]:
    Place a check mark on this to send E-mail to the second E-mail 
    address periodically. It will be sent on the days and time with the 
    check mark.
    11  [Submit]
    Update the settings.
    [Authentication set up] page
    You can set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail message.
    Click [Detailed set up]
     → [Authentication set up].
    (1)
    (2)
    (3)
    (4)
    (5)
    (6)
    (7)
    (8)
    1  [Auth]
    Select the authentication method specified by your Internet 
    service provider.
    2  [SMTP Auth]
    Set when the SMTP authentication is selected.
    3  [POP server name]
    Enter the POP server name.
    Allowed characters:
    Alphanumerics (A to Z, a to z, 0 to 9)
    Minus sign (-) and period (.)
    4  [User name]
    Enter the user name for the POP server or the SMTP server.
    5  [Password]
    Enter the password for the POP server or the SMTP server.
    6  [SMTP server port]
    Enter the port number of the SMTP server.
    (Normally 25) 7 
    [POP server port]
    Enter the port number of the POP server.
    (Normally 110)
    8  [Submit]
    Update the settings.  
    						
    							ENGLISH - 103
    Chapter 4 Settings — [NETWORK] menu
    Contents of mail sent
    Example of E-mail sent when E-mail is set
    The following E-mail is sent when the E-mail settings have been established.
    === Panasonic projector report(CONFIGURE) ===
    Projector Type          : DW640
    Serial No               : SH1234567
    -----  E-mail setup data -----
    TEMPERATURE WARNING SETUP 
    MINIMUM TIME           at [ 60] minutes interval 
    INTAKE AIR TEMPERATURE Over [ 45 degC / 113 degF ] 
    ERROR                   [ OFF ] 
    LAMP1 RUNTIME           [ OFF ]   at REMAIN [ 400] H 
    LAMP1 RUNTIME           [ OFF ]   at REMAIN [ 200] H 
    LAMP2 RUNTIME           [ OFF ]   at REMAIN [ 400] H 
    LAMP2 RUNTIME           [ OFF ]   at REMAIN [ 200] H 
    INTAKE AIR TEMPERATURE  [ OFF ] 
    PERIODIC REPORT 
    Sunday    [ OFF ]  Monday    [ OFF ]  Tuesday   [ OFF ]  Wednesday [ OFF ] 
    Thursday  [ OFF ]  Friday    [ OFF ]  Saturday  [ OFF ] 
    00:00  [ OFF ]    01:00  [ OFF ]    02:00  [ OFF ]    03:00  [ OFF ] 
    04:00  [ OFF ]    05:00  [ OFF ]    06:00  [ OFF ]    07:00  [ OFF ] 
    08:00  [ OFF ]    09:00  [ OFF ]    10:00  [ OFF ]    11:00  [ OFF ] 
    12:00  [ OFF ]    13:00  [ OFF ]    14:00  [ OFF ]    15:00  [ OFF ] 
    16:00  [ OFF ]    17:00  [ OFF ]    18:00  [ OFF ]    19:00  [ OFF ] 
    20:00  [ OFF ]    21:00  [ OFF ]    22:00  [ OFF ]    23:00  [ OFF ] 
    -----  check system -----
    MAIN CPU BUS  [   OK   ]
    FAN  [   OK   ]
    INTAKE AIR TEMPERATURE  [   OK   ]
    OPTICS MODULE TEMPERATURE  [   OK   ]
    AROUND LAMP TEMPERATURE  [   OK   ]
    LAMP1 REMAIN TIME  [   OK   ]
    LAMP2 REMAIN TIME  [   OK   ]
    LAMP1 STATUS  [   OK   ]
    LAMP2 STATUS  [   OK   ]
    SHUTTER  [   OK   ]
    INTAKE AIR TEMP.SENSOR  [   OK   ]
    OPTICS MODULE TEMP.SENSOR  [   OK   ]
    AROUND LAMP TEMP.SENSOR  [   OK   ]
    BATTERY  [   OK   ]
    COLOR WHEEL  [   OK   ]
    COVER OPEN  [   OK   ]
    FILTER UNIT  [   OK   ]
    AIR FILTER  [   OK   ]
    (Error code 00 00 00 00 00 00 00 00)
    Intake air temperature     : 26 degC /  78 degF
    Optics module temperature  : 39 degC / 102 degF
    Around lamp temperature    : 30 degC /  86 degF
    PROJECTOR RUNTIME     1 H
    POWER ON              1 times
    LAMP1 ON              1 times
    LAMP1 ECO             0 H
    LAMP1 NORMAL          0 H
    LAMP1 REMAIN       2499 H
    LAMP2 ON              1 times
    LAMP2 ECO             0 H
    LAMP2 NORMAL          1 H
    LAMP2 REMAIN       2499 H
    -------- Current status ---------
    MAIN VERSION         1.00 
    NETWORK VERSION      1.00 
    SUB VERSION          1.00 
    LAMP STATUS          LAMP1=ON  LAMP2=ON 
    INPUT SIGNAL         RGB1   ---
                         0.00kHz / 0.00Hz
    REMOTE2 STATUS       DISABLE 
    ----- Wired Network configuration -----
    DHCP Client  OFF 
    IP address   192.168.10.100
    MAC address  70:58:12:00:00:00
    Wed Jan 18 11:42:37 2012
    ----- Memo -----  
    						
    							104 - ENGLISH
    Chapter 4 Settings — [NETWORK] menu
    Example of the E-mail sent for an error
    The following E-mail is sent when an error has occurred.
    === Panasonic projector report(CONFIGURE) ===
    Projector Type          : DW640
    Serial No               : SH1234567
    -----  check system -----
    MAIN CPU BUS   [   OK   ]
    FAN   [   OK   ]
    INTAKE AIR TEMPERATURE   [   OK   ]
    OPTICS MODULE TEMPERATURE   [   OK   ]
    AROUND LAMP TEMPERATURE   [   OK   ]
    LAMP1 REMAIN TIME   [   OK   ]
    LAMP2 REMAIN TIME   [   OK   ]
    LAMP1 STATUS   [   OK   ]
    LAMP2 STATUS   [   OK   ]
    SHUTTER    [   OK   ]
    INTAKE AIR TEMP.SENSOR    [   OK   ]
    OPTICS MODULE TEMP.SENSOR   [   OK   ]
    AROUND LAMP TEMP.SENSOR   [   OK   ]
    BATTERY   [   OK   ]
    COLOR WHEEL   [   OK   ]
    COVER OPEN   [   OK   ]
    FILTER UNIT   [ FAILED ]
    AIR FILTER   [   OK   ]
    (Error code 04 00 00 00 00 00 00 00)
    Intake air temperature     : 26 degC /  78 degF
    Optics module temperature  : 39 degC / 102 degF
    Around lamp temperature    : 30 degC /  86 degF
    PROJECTOR RUNTIME     1 H
    POWER ON              1 times
    LAMP1 ON              1 times
    LAMP1 ECO             0 H
    LAMP1 NORMAL          0 H
    LAMP1 REMAIN       2499 H
    LAMP2 ON              1 times
    LAMP2 ECO             0 H
    LAMP2 NORMAL          1 H
    LAMP2 REMAIN       2499 H
    -------- Current status ---------
    MAIN VERSION         1.00 
    NETWORK VERSION      1.00 
    SUB VERSION          1.00 
    LAMP STATUS          LAMP1=ON  LAMP2=ON 
    INPUT SIGNAL         RGB1   ---
                         0.00kHz / 0.00Hz
    REMOTE2 STATUS       DISABLE 
    ----- Wired Network configuration -----
    DHCP Client  OFF 
    IP address   192.168.10.100
    MAC address  70:58:12:00:00:00
    Wed Jan 18 11:42:37 2012
    ----- Memo -----
    User name [Change password] page
    Click [Change password].
    1
    2
    3
    1  [Administrator]
    Used to change the setting of the [Administrator].
    2  [User]
    Used to change the setting of the [User].
    3  [Next]
    Used to change the setting of the password.  
    						
    							ENGLISH - 105
    Chapter 4 Settings — [NETWORK] menu
    [Administrator] account
    (1)
    (2)
    (3)
    (4)
    (5)
    (6)
    (7)
    1 [Account]
    Displays the account to change.
    2  [Current][User name]
    Enter the user name before the change.
    3  [Current][Password]
    Enter the current password.
    4  [New][User name]
    Enter the desired new user name. (Up to 16 characters in single 
    byte) 5 
    [New][Password]
    Enter the desired new password. (Up to 16 characters in single 
    byte)
    6  [New][Password(Retype)]
    Enter the desired new password again.
    7  [OK]
    Determines the change of password.
    [User] account
    (1)
    (2)
    (3)
    (5) (4)
    1 [Account]
    Displays the account to change.
    2  [New][User name]
    Enter the desired new user name. (Up to 16 characters in single 
    byte)
    3  [New][Password]
    Enter the desired new password. (Up to 16 characters in single 
    byte)
    4  [New][Password(Retype)]
    Enter the desired new password again.
    5  [OK]
    Determines the change of password.  
    						
    							106 - ENGLISH
    Chapter 4 Settings — [NETWORK] menu
    [Change password] (For user rights)
    Only the change of password is enabled under the user rights.
    (1)
    (2)
    (4) (3)
    1 [Old Password]
    Enter the current password.
    2  [New Password]
    Enter the desired new password. (Up to 16 characters in single 
    byte) 3 
    [Retype]
    Enter the desired new password again.
    4  [OK]
    Determines the change of password.
    Note
    r
    f To change the account of the administrator, you must enter the [Current] [User name] and [Password].
    [CRESTRON RoomView] page
    The projector can be monitored and/or controlled with RoomView.
    To start the RoomView control page from the Web control screen, you need to access with the administrator rights. (For user rights, the 
    [CRESTRON RoomView] button is not displayed on the Web control screen.)
    The control page of RoomView is displayed by clicking [CRESTRON RoomView].
    It is not displayed if Adobe Flash Player is not installed on the computer used, or the browser used does not support Flash. In that case, click 
    [Back] on the control page to go back to the previous page.
    Control page
    1
    2
    3
    4
    5
    6
    7
    1 
    [Tools][Info][Help]
    Tabs for selecting the setting, information, or help page of the 
    projector.
    2  [POWER]
    Switches the power on/off.
    3  [SHUTTER]
    Switches between use or not use of the shutter function.
    4  [Input Select]
    Controls input selection.
    Not available when the power of the projector is turned off.
    5  Menu screen control buttons
    Navigates the menu screen. 6 
    Freeze/Picture quality adjustment
    Controls items related to freeze/picture quality.
    7  [Back]
    Performs return to the previous page.  
    						
    							ENGLISH - 107
    Chapter 4 Settings — [NETWORK] menu
    [Tools] page
    Click [Tools] on the control page.
    1
    2
    3
    4
    5
    1 [Control System]
    Set the information required for communicating with the 
    controller to be connected with the projector.
    2  [User Password]
    Set the user rights password for the RoomView control page.
    3  [Admin Password]
    Set the administrator rights password for the RoomView control 
    page.
    4  Network Status
    Displays the settings of wired LAN. [DHCP]
    Displays the current setting.
    [Ip Address]
    Displays the current setting.
    [Subnet Mask]
    Displays the current setting.
    [Default Gateway]
    Displays the current setting.
    [DNS Server]
    Displays the current setting.
    5  [Exit]
    Returns to the control page.
    [Info] page
    Click [Info] on the control page.
    45
    6
    7
    1
    2
    3
    8
    1 [Projector Name]
    Displays the projector name.
    2  [Mac Address]
    Displays the MAC address.
    3  [Lamp Hours]
    Displays the cumulative operating time (converted value) of the 
    lamps.
    4  [Power Status]
    Displays the status of the power.
    5  [Source]
    Displays the selected image input.
    6  [Lamp Mode]
    Displays the lamp mode.
    7  [Error Status]
    Displays the error status.
    8  [Exit]
    Returns to the control page.  
    						
    							108 - ENGLISH
    Chapter 4 Settings — [NETWORK] menu
    [Help] page
    Click [Help] on the control page.
    The [Help Desk] window is displayed.
    1
    1 [Help Desk]
    Messages can be sent to or received from an administrator who 
    uses Crestron RoomView.  
    						
    							ENGLISH - 109
    Chapter 5 Maintenance
    This chapter describes inspection when there are problems, and maintenance methods.  
    						
    							110 - ENGLISH
    Chapter 5 Maintenance — Lamp/Temperature/Filter indicators
    Lamp/Temperature/Filter indicators
    Managing the indicated problems
    If a problem should occur inside the projector, the lamp indicators // the temperature indicator  and the filter 
    indicator  will inform you by lighting or flashing.
    Check the status of the indicators and manage the indicated problems as follows.
    Attention
    r
    f When switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” (
    x page 43).
    r
    f Check the status of the power supply with the power indicator  (
    x page 42).
    /DPSLQGLFDWRU/$03!
    3RZHULQGLFDWRU21*67
    $1%
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic DLP Projector PT-DW640U PT-DW640UL PT-DX610U PT-DX610UL Operating Instructions