Home > Panasonic > Hub > Panasonic Multi Control Hub Aw Hb605 Operating Instructions

Panasonic Multi Control Hub Aw Hb605 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Multi Control Hub Aw Hb605 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Before attempting to connect, operate or adjust this product, please
    read these instructions completely.
    P
    O
    W
    E
    ROFFON
    Multi Control Hub AW–
    Multi Control Hub
    Model AW- P 
    						
    							3 2
    indicates safety information.
    CAUTION
    RISK OF ELECTRIC SHOCK
    DO NOT OPEN
    CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, 
    DO NOT REMOVE COVER (OR  BACK).
    NO USER SERVICEABLE PARTS INSIDE.
    REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
    The lightning flash with arrowhead symbol, within an equilateral triangle,
    is intended to alert the user to the presence of uninsulated “dangerous
    voltage” within the product’s enclosure that may be of sufficient
    magnitude to constitute a risk of electric shock to persons.
    The exclamation point within an equilateral triangle is intended to alert the
    user to the presence of important operating and maintenance (service)
    instructions in the literature accompanying the appliance.
    indicates safety information.
    FCC Note:
    This device complies with Part 15 of the FCC Rules. To assure continued
    compliance follow the attached installation instructions and do not make any
    unauthorized modifications.
    This equipment has been tested and found to comply with the limits for a class A
    digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
    provide reasonable protection against harmful interference when the equipment is
    operated in a commercial environment. This equipment generates, uses, and can
    radiate radio frequency energy and, if not installed and used in accordance with the
    instruction manual, may cause harmful interference to radio communications.
    Operation of this equipment in a residential area is likely to cause harmful
    interference in which case the user will be required to correct the interference at his
    own expense.
    CAUTION:Do not install or place this unit in a bookcase, built-in cabinet or any
    other confined space in order to maintain adequate ventilation. Ensure
    that curtains and any other materials do not obstruct the ventilation to
    prevent risk of electric shock or fire hazard due to overheating.WARNING:TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT
    EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.CAUTION:TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING
    INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY.CAUTION:OKeep the temperature inside the rack to between 14°F to 113°F
    (–10°C to 45°C). 
    						
    							5 4
    For Your SafetyOUse the dedicated AC adapter (AW-PS505) to supply power to the multi control hub.
    OHandle with care.
    The multi control hub may malfunction if it is dropped or exposed to strong shocks.
    OUse within a temperature range of 14°F to 113°F (–10°C to +45°C).
    Using the multi control hub in environments colder than 14°F (–10°C) or hotter than
    113°F (+45°C) could have a damaging effect on the internal components.
    OConnect and disconnect cables only when the power is turned off.
    Make sure to turn the power to the multi control hub off before connecting or
    disconnecting cables.
    OAvoid using the multi control hub outdoors.
    OPlace the multi control hub a minimum of 1 meter away from monitor video screens.
    OCleaning
    Unplug the multi control hub and wipe it clean using a dry cloth. For dirt that cannot be
    removed in this manner, moisten a cloth with kitchen detergent, wring it out thoroughly,
    and then wipe gently.
    • Never use volatile chemicals such as benzene or paint thinner to clean the multi
    control hub.
    • Before using chemically treated cloths to clean the multi control hub, read their
    instructions and precautions thoroughly.
    AccessoriesOPriority switchboxes: 5
    ORack mounting brackets: 12
    OMounting screws: 24OverviewOThe AW-HB605 multi control hub combines with a system such as the Panasonic AW-
    PH300 series indoor pan/tilt head or AW-PH600 series outdoor pan/tilt head to support
    the connection of between one and five control panels (AW-RP501, AW-RP301, AW-
    RP305) to a single camera and pan/tilt head. Any of the connected control panels may
    then be used to control the camera and pan/tilt head (the AW-RP301 and AW-RP305
    can control the pan/tilt head only).
    In addition, by adding the AW-HB505 multi port hub and AW-RP505 multi hybrid control
    panel, it is possible to construct a system in which between one and five multi hybrid
    control panels may be used to control between one and five cameras and pan/tilt heads.
    OWhen coaxial cable/s (5C-2V) and 10BASE-T (UTP category 5) straight cable/s
    (10BASE-T cable only for the AW-RP301 and AW-RP305) are used to make
    connections, the distance between the cameras and pan/tilt heads and the control
    panels can be extended up to a maximum of 500 meters.Table of ContentsOverview. . . . . . . . . . . . . . . . . . . . . . . . . 4
    Accessories. . . . . . . . . . . . . . . . . . . . . . 4
    For Your Safety. . . . . . . . . . . . . . . . . . . . 5
    Controls and Their Functions. . . . . . . . 6
    $Front Panel . . . . . . . . . . . . . . . . . . . . 6
    $Rear Panel . . . . . . . . . . . . . . . . . . . . 7
    $Priority Switchbox . . . . . . . . . . . . . . 10System Connections. . . . . . . . . . . . . . 11
    Operations. . . . . . . . . . . . . . . . . . . . . . . 17
    Rack Mounting Example. . . . . . . . . . . 18
    $Rack Mounting Procedure . . . . . . . 18
    Specifications. . . . . . . . . . . . . . . . . . . . 19 
    						
    							7 6
    Controls and Their Functions
    PREVIEW OUT
    CAM CONT IN5
    PAN/TILT
    CONTROL IN
    BLACK
    BURST OUT
    PREVIEW OUT
    CAM CONT IN4
    PAN/TILT
    CONTROL IN
    BLACK
    BURST OUT
    PREVIEW OUTTO CONTROL PANEL TO PAN/TILT HEAD HUBCAM CONT IN3
    PAN/TILT
    CONTROL IN
    BLACK
    BURST OUT
    PREVIEW OUT
    CAM CONT IN2
    PAN/TILT
    CONTROL IN
    BLACK
    BURST OUT
    PREVIEW OUT
    CAM CONT IN1
    PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTBLACK
    BURST
    OUT
    PREVIEW IN
    CAM CONT OUTPAN/TILT
    CONTROL OUT
    + -
    DC12V IN
    9
    8
    4
    57
    ;
    :
    6
    3
    3
    DC +12 V Input Connector [DC12 V IN]
    (4-pin Cannon Connector)Connect the AW-PS505 AC adapter
    (sold separately) to this connector.
    4
    Pan/Tilt Head Control Signal Output
    Connector [TO PAN/TILT HEAD HUB
    PAN/TILT CONTROL OUT] (RJ-45 8-
    pin Modular Jack)
    Connect this connector to the control
    signal input connector [P/T CONTROL
    IN] of the AW-PH300 or AW-PH600
    pan/tilt head, or to the pan/tilt control
    signal input connector [TO CONTROL
    PANEL PAN/TILT CONTROL IN] of the
    AW-HB505 multi port hub using a
    10BASE-T (UTP category 5) straight
    cable.5
    Preview Video Signal Input
    Connector [TO PAN/TILT HEAD HUB
    PREVIEW IN] (BNC Connector)
    Connect this connector to the video
    signal output connector [VIDEO OUT] of
    the pan/tilt head, or to the preview video
    signal output connector [TO CONTROL
    PANEL PREVIEW OUT] of the multi
    port hub using a coaxial cable (5C-2V
    equivalent).
    
    In a system incorporating the AW-
    RP301 or AW-RP305, the control panel
    is not equipped with a video signal cable
    compensation circuit. It may therefore
    be necessary to use a separate cable
    compensation device in some cases. $Rear Panel
    Controls and Their Functions$Front Panel
    1
    Power Indicator LED [POWER]
    This indicator lights (red) when the
    power switch 2
    is at the ON position.  It
    is dark when the power switch 2
    is at
    the OFF position.2
    Power Switch [POWER ON/OFF]
    Placing this switch at the ON position
    when the AC adapter is connected and
    turned on supplies power to the multi
    control hub (power indicator LED lights).
    Placing it at the OFF position cuts off
    the power.
    
    This switch must be at the ON position
    in order to control the camera and
    pan/tilt head from each control panel.
    POWEROFF ON1
    2
    Multi Control Hub AW– 
    						
    							9 8
    Controls and Their Functions:
    Camera Control Signal Input
    Connector [TO CONTROL PANEL
    CAM CONT IN] (BNC Connector)
    Connect this connector to the camera
    control signal output connector [TO
    CAMERA PAN/TILT HEAD CAMERA
    CONTROL OUT] of the hybrid control
    panel (AW-RP501), or to the camera
    control signal output connector [TO
    CAMERA PAN/TILT HEAD CAMERA
    CONTROL OUT] of the multi hybrid
    control panel (AW-RP505) using a
    coaxial cable (5C-2V equivalent).
    If the system incorporates a pan/tilt
    control panel (AW-RP301) or multi
    pan/tilt control panel (AW-RP305), the
    control panel is not equipped with a
    camera control output connector. In this
    case, this connector should be left
    unconnected.
    ;
    Black Burst Output [BLACK BURST
    OUT] (BNC Connector)
    This is the output jack for the reference
    signal generator built into the multi
    control hub.  This signal may be used as
    the reference signal for peripheral
    equipment that uses external
    synchronization.
    Controls and Their Functions6
    Black Burst Output [TO PAN/TILT
    HEAD HUB BLACK BURST OUT]
    (BNC Connector)
    This is the output jack for the reference
    signal generator built into the multi
    control hub.  This signal may be used as
    the reference signal if the camera uses
    external synchronization.
    Connect this connector to the G/L signal
    input connector [G/L IN] of the pan/tilt
    head, or to the G/L signal input
    connector [TO CONTROL PANEL G/L
    IN] of the multi port hub using a coaxial
    cable (5C-2V equivalent).
    7
    Camera Control Output Connector
    [TO PAN/TILT HEAD HUB CAM CONT
    OUT] (BNC Connector)
    Connect this connector to the camera
    control signal input connector [CAMERA
    CONTROL IN] of the pan/tilt head, or to
    the camera control signal input
    connector [TO CONTROL PANEL
    CAMERA CONTROL IN] of the multi
    port hub using a coaxial cable (5C-2V
    equivalent).8
    Pan/Tilt Head Control Signal Input
    Connector [TO CONTROL PANEL
    PAN/TILT CONTROL IN] (RJ-45 8-pin
    Modular Jack)
    Connect this connector to the control
    panel pan/tilt control signal output
    connector [PAN/TILT CONTROL OUT]
    of the control panel using a 10BASE-T
    (UTP category 5) straight cable.
    9
    Preview Video Signal Output
    Connector [TO CONTROL PANEL
    PREVIEW OUT] (BNC Connector)
    Connect this connector to the video
    input connector [TO CAMERA
    PAN/TILT HEAD VIDEO IN] of the
    hybrid control panel (AW-RP501), or to
    the preview video input connector
    [PREVIEW IN] of the multi hybrid control
    panel (AW-RP505) using a coaxial cable
    (5C-2V equivalent).
    If the system incorporates a pan/tilt
    control panel (AW-RP301) or multi
    pan/tilt control panel (AW-RP305), the
    control panel is not equipped with a
    video input connector. If necessary, the
    output from the preview video signal
    output connector may be connected to a
    monitor video screen, VCR, or the like
    via a cable compensation device. 
    						
    							11 10
    System Connections 
    (Indoor Pan/tilt Head System)
    OTurn off the power to all pieces of
    equipment before making any
    connections.
    OFor the control panel, use the AC
    adapter model AW-PS301 (sold
    separately), for the multi port hub and
    multi control hub, the AC adapter model
    AW-PS505 (sold separately), and for the
    pan/tilt head AC adapter model, the AW-
    PS300 (sold separately).
    OUse an AW-PH300 series pan/tilt head
    and a camera from the convertible
    camera series.
    Use camera cable AW-CA50 T15 (sold
    separately) to make connections
    between the pan/tilt head and camera.
    OConnect the pan/tilt head (AW-PH300)
    to its AC adapter (AW-PS300) using a
    DC power cord (cable conforming to the
    Electrical Equipment Handling Law and
    with a nominal cross-sectional area of
    1.25 mm
    2
    or more, to be obtained
    locally). The maximum cable distance
    between the pan/tilt head and its AC
    adapter is 30 meters.
    OConnect the multi control hub to its AC
    adapter (AW-PS505).
    OConnect the multi port hub to its AC
    adapter (AW-PS505).
    OConnect the control panel (AW-RP301,
    AW-RP305, AW-RP501, AW-RP505) to
    its AC adapter (AW-PS301). Use a cord
    clamper to secure the DC cord of the
    AC adapter and prevent the DC plug
    from coming loose accidentally.
    OConnect the pan/tilt head and the
    convertible camera using the AW-CA50
    T15 camera cable.
    OConnect the electric zoom lens iris
    control cable to the camera and the
    remote (zoom and focus control) cable
    to the pan/tilt head.
    Cord clamper
    Control panel AC adapter:
    AW-PS301DC cord
    Remote (zoom/focus
    control) cableIris control cable
    To lens interface
    connector To iris connector
    Controls and Their Functions<
    Priority Switchbox Contacts
    (Terminal Panel)
    These are the output contacts of the
    priority switchbox. They should be
    connected to the TALLY terminals on
    the control panel. These terminals are
    not polarized. Make connections using
    cable conforming to the Electrical
    Equipment Handling Law and with a
    nominal cross-sectional area of 0.128
    mm
    2(wire number AWG26) or more.
    The maximum cable length (distance
    between priority switchbox and control
    panel) is 10 meters.The connection terminals differ depending
    on the control panel model. The correct
    connection terminals are listed below.
    AW-RP301:
    TALLY HOT and GND terminals.
    AW-RP305:
    Any of terminals TALLY 1 through
    TALLY 5 and the GND terminal. (Make
    sure that the pan/tilt head control
    connector number to which the AW-
    HB605 is connected and the TALLY
    terminal number to which the priority
    switchbox is connected match.)
    Also, if the pan/tilt head is being
    controlled via the AW-HB605, it is
    necessary to select the number to which
    the AW-HB605 is connected using the
    pan/tilt head selector switch of the AW-
    RP305.
    AW-RP501:
    TALLY HOT and GND terminals.
    AW-RP505:
    TALLY 5 and GND terminals. $Priority Switchbox
    < 
    						
    							13 12
    MENUOPT CN CARD
    VIDEO OUT
    LF REMCTEGL NDC12V INIRIS TEM AWC
    YES ABCNO BARO    I
    PREVIEW OUT
    CAM CONT IN5PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN4PA N / T I LT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUTTO CONTROL PANEL TO PAN/TILT HEAD HUBCAM CONT IN3PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN2PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN1PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTBLACK
    BURST
    OUTPREVIEW IN
    CAM CONT OUTPA N / T I LT
    CONTROL OUT
    + -DC12V IN
    O    IConvertible camera
    Iris control cable
    Remote (zoom/focus control) cablePan/tilt head: AW-PH300
    Camera mounting
    adapterPan/tilt head cable:
    AW-CA50T15
    Pan/tilt head AC adapter:
    AW-PS300
    AC 120 V
    AC adapter:
    AW-PS505
    AC 120 V
    AC adapter:
    AW-PS301
    AC 120 V MonitorMulti pan/tilt control panel:
    AW-RP305 Multi control hub:
    AW-HB605
    Priority
    switchbox Coaxial cable:
    Video signal
    10BASE-T cable:
    Pan/tilt head control
    signal
    10BASE-T cable:
    Pan/tilt head control
    signal
    System Connections 
    (Indoor Pan/tilt Head System)
    $System Incorporating AW-RP305
    
    Since the multi pan/tilt control panel is not equipped with a video signal compensation
    circuit, it may be necessary to use a separate cable compensation device in some cases.
    Maximum Cable Length
    The maximum cable length from the camera and
    pan/tilt head to the multi pan/tilt control panel is 500
    meters.
    O    I
    PREVIEW OUT
    CAM CONT IN5PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN4PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUTTO CONTROL PANEL TO PAN/TILT HEAD HUBCAM CONT IN3PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN2PA N / T I LT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN1PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTBLACK
    BURST
    OUTPREVIEW IN
    CAM CONT OUTPAN/TILT
    CONTROL OUT
    + -DC12V IN
    O    IMENUOPT CN CARD
    VIDEO OUT
    LF REMCTEGL NDC12V INIRIS TEM AWC
    YES ABCNO BAR
    System Connections 
    (Indoor Pan/tilt Head System)
    Convertible camera
    Iris control cable
    Remote (zoom/focus control) cablePan/tilt head: AW-PH300
    Camera mounting
    adapterPan/tilt head cable:
    AW-CA50T15
    Pan/tilt head AC adapter:
    AW-PS300
    AC 120 V
    AC adapter:
    AW-PS505
    AC 120 V
    AC adapter:
    AW-PS301
    AC 120 V MonitorPan/tilt control panel:
    AW-RP301 Multi control hub:
    AW-HB605
    Priority
    switchbox Coaxial cable:
    Video Signal
    10BASE-T cable:
    Pan/tilt head control
    signal
    10BASE-T Cable:
    Pan/tilt head control
    signal
    $System Incorporating AW-RP301
    
    Since the pan/tilt control panel is not equipped with a video signal compensation circuit, it
    may be necessary to use a separate cable compensation device in some cases.Maximum Cable Length
    The maximum cable length from the camera and
    pan/tilt head to the pan/tilt control panel is 500 meters. 
    						
    							15 14
    MENUOPT CN CARD
    VIDEO OUT
    LF REMCTEGL NDC12V INIRIS TEM AWC
    YES ABCNO BARO    I
    PREVIEW OUT
    CAM CONT IN5PA N / T I LT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN4PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUTTO CONTROL PANEL TO PAN/TILT HEAD HUBCAM CONT IN3PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN2PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN1PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTBLACK
    BURST
    OUTPREVIEW IN
    CAM CONT OUTPAN/TILT
    CONTROL OUT
    + -DC12V IN
    O    I
    O    I
    System Connections 
    (Indoor Pan/tilt Head System)
    Convertible camera
    Iris control
    cable
    Remote (zoom/focus control) cablePan/tilt head: AW-PH300
    Camera mounting
    adapterPan/tilt head cable:
    AW-CA50T15
    Pan/tilt head AC adapter:
    AW-PS300
    AC 120 V
    AC adapter:
    AW-PS505
    AC 120 V
    AC adapter:
    AW-PS505
    AC 120 V
    AC adapter:
    AW-PS301 AC 120 VPreview
    monitor Monitor
    S-Video
    Multi hybrid control
    panel:
    AW-RP505 Multi port hub:
    AW-HB505
    Multi control hub:
    AW-HB605
    Priority
    switchbox Coaxial cable:
    Video signal Coaxial cable:
    Gen-lock signal
    Coaxial cable:
    Camera control signalCoaxial cable:
    Camera control signal
    Coaxial cable:
    Video signal
    Coaxial cable:
    Gen-lock signal
    Coaxial cable:
    Camera control signal
    Coaxial cable:
    Video signal10BASE-T cable:
    Pan/tilt head control signal
    10BASE-T cable:
    Pan/tilt head control
    signal
    $System Incorporating AW-RP505 or
    AW-HB505Maximum Cable Length
    The maximum cable length from the camera and
    pan/tilt head to the multi hybrid control panel is 500
    meters.
    MENUOPT CN CARD
    VIDEO OUT
    LF REMCTEGL NDC12V INIRIS TEM AWC
    YES ABCNO BAR
    PREVIEW OUT
    CAM CONT IN5PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN4PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUTTO CONTROL PANEL TO PAN/TILT HEAD HUBCAM CONT IN3PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN2PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTPREVIEW OUT
    CAM CONT IN1PAN/TILT
    CONTROL IN
    BLACK
    BURST OUTBLACK
    BURST
    OUTPREVIEW IN
    CAM CONT OUTPAN/TILT
    CONTROL OUT
    + -DC12V IN
    O    IO    I
    System Connections 
    (Indoor Pan/tilt Head System)
    Convertible camera
    Iris control cable
    Remote (zoom/focus control) cablePan/tilt head: AW-PH300
    Camera mounting
    adapterPan/tilt head cable:
    AW-CA50T15
    Pan/tilt head AC adapter:
    AW-PS300
    AC 120 V
    AC adapter:
    AW-PS505
    AC 120 V
    AC adapter:
    AW-PS301
    AC 120 VMonitor
    S-Video
    Hybrid control panel:
    AW-RP501 Multi Control Hub:
    AW-HB605
    Priority
    switchbox Coaxial cable:
    Video Signal
    Coaxial cable:
    Camera control signal
    Coaxial cable:
    Camera control signal
    Coaxial cable:
    Video signal10BASE-T cable:
    Pan/tilt head control
    signal
    10BASE-T cable:
    Pan/tilt head control
    signal
    $System Incorporating AW-RP501Maximum Cable Length
    The maximum cable length from the camera and
    pan/tilt head to the hybrid control panel is 500 meters. 
    						
    							POWER
    1
    YC2
    YC3
    YC4
    YC5
    YC
    OFF ON
    CABLE  COMP
    Multl  Port  Hub  AW-H8505
    O    I
    O    I
    POWER
    OFF ON
    17 16
    Operations1.
    Turn the power on.
    Turn on the power control switches of
    the AC adapters of the pan/tilt heads
    and control panels, as well as the AC
    adapter and power control switch of the
    multi control hub.
    If the system incorporates a multi port
    hub, turn on the power control switch of
    the multi port hub and the power switch
    of its AC adapter.
    2.
    Press the button on the priority
    switchbox connected to the control
    panel you wish to operate. This
    activates the connected control panel.
    If the system incorporates a multi hybrid
    control panel, use the camera and
    pan/tilt head selector switch on the multi
    hybrid control panel to select a pan/tilt
    head. (The control panel is activated
    once its memory switch stops flashing
    and goes dark.)
    
    OImmediately after the power is turned
    on the system is in a status in which
    no control panel is selected. After
    turning the power on, do not fail to
    press the priority switchbox
    connected to the control panel you
    wish to operate. After this operation
    is performed the power supply to the
    camera and pan/tilt head turns on.
    OThe active control panel is always the
    one connected to the priority
    switchbox pressed last.
    3.
    Perform the mounting balance
    adjustment on the cameras. For detailed
    instructions, refer to the manuals
    accompanying the relevant equipment.
    4.
    Set the limits to the range of movement
    for the pan/tilt head (limiter). For
    detailed instructions, refer to the
    manuals accompanying the relevant
    equipment.
    5.
    If the system incorporates a hybrid
    control panel or multi hybrid control
    panel, perform video signal cable
    compensation, G/L (gen-lock)
    adjustment, and total pedestal
    adjustment. Also set the switches as
    appropriate. For detailed instructions,
    refer to the manuals accompanying the
    relevant equipment.
    
    After performing G/L (gen-lock)
    adjustment and total pedestal
    adjustment, set the control panel’s G/L
    phase adjustment switch to the OFF
    position. The instruction manual of the
    hybrid control panel states that this
    switch should be left in the ON position,
    but it should be set to OFF on systems
    using the multi control hub.
    6.
    Store the preset settings for the
    cameras and pan/tilt heads in memory
    (systems incorporating hybrid control
    panel or multi hybrid control panel only).
    For detailed instructions, refer to the
    manuals accompanying the relevant
    equipment.
    
    The preset settings are stored in the
    memory of the pan/tilt head. When new
    preset settings are stored in memory, all
    the previous settings (including those
    stored in memory using the control
    panel) are overwritten.
    The adjustments and settings described
    in steps 
    3
    though 
    6
    above may be
    omitted if no changes need to be made to
    the current adjustments and settings.
    Zoom/focus control
    Option switch
    control:
    Unnecessary if no
    optional unit is
    connected.
    DC15V Lamp control:
    Unnecessary if no
    halogen lamp is used.
    Pan/tilt head AC
    adapter:
    AW-PS300
    Optional unit ContactGen-lock
    VideoVideoS-Video
    Preview Video
    Preview Video Preview VideoGen-lock Camera control
    Camera control Pan/tilt head
    control
    Pan/tilt head control
    Camera control
    Pan/tilt head control Halogen lamp Servo control
    zoom lensConvertible
    cameraColor monitor
    (75 Ωterminator)
    Preview color
    monitor
    (75 Ωterminator) Camera cable:
    AW-CA50T15 Iris control
    AC adapter:
    AW-PS505
    AC adapter:
    AW-PS505
    AC adapter:
    AW-PS301 Multi hybrid control
    panel:
    AW-RP505 Multi port hub:
    AW-HB505
    Multi control hub:
    AW-HB605
    Priority
    switchbox Adjustment such as cable compensation, gen-
    lock adjustment, and total pedestal adjustment
    should be applied to the video signals output
    from the AW-HB505.System Connections 
    (Indoor Pan/tilt Head System)
    $Example System Setup 
    						
    							19 18
    SpecificationsPower supply:
    DC +12 V (4-pin Cannon Connector)
    Power consumption:
    DC 12 V, 0.47 AVideo input:
    Composite video 1 V [p-p] 75 Ωa
    1
    (BNC connector)
    Camera control inputs:
    Control signal (BNC connector) a
    5
    Pan/tilt head control inputs:
    Control signal (RJ-45 8-pin modular
    jack) a
    5
    Preview video outputs:
    Composite video 1 V [p-p] 75 Ωa
    5
    (BNC connector)
    Black burst outputs:
    75 Ωa
    6 (BNC connector)
    Camera control output:
    Control signal (BNC connector)
    Pan/tilt head control output:
    Control signal (RJ-45 8-pin modular
    jack)
    Switch function:
    Power on/off
    Control panel connecting cables:
    Number of connecting cables: 4 (3
    coaxial cables, 1 10BASE-T straight
    cable); 5 sets (when using G/L function)
    Pan/tilt head connecting cables:
    4 connecting cables per pan/tilt head (3
    coaxial cables, 10BASE-T straight
    cable)
    (when using G/L function)
    Maximum cable length:
    Length of cable from camera and pan/tilt
    head to control panel: Max. 500 m
    (assuming: coaxial cable: 5C-2V,
    10BASE-T straight cable: UTP category
    5)Operating temperature range:
    +14°F to +113°F (–10°C to +45°C)
    Dimensions (Wa
    Ha
    D):
    Body:
    16 
    9/16˝a
    3 
    1/2˝a
    9 
    7/8˝
    (420a
    88a
    250 mm)
    Priority switchbox:
    2 
    13/16˝a
    3 
    1/2˝a
    1 
    7/16˝
    (70a
    88a
    35 mm)
    Weight:
    Approx. 12.32 lb (5.6 kg)
    Finish:
    Cover:
    Steel panel with AV ivory color
    polyvinyl chloride finish (approximate
    color: Munsell 7.9Y 6.8/0.8)
    Panel:
    AV ivory color paint (approximate
    color: Munsell 7.9Y 6.8/0.8)
    Rack Mounting Example$Rack Mounting Procedure
    Multi Control HubTo mount the multi control hub on a rack,
    use the supplied rack mounting brackets
    and mounting screws (M4a
    10).
    1
    Press the power switch to turn power
    off.
    2
    Remove the four feet from the bottom of
    the multi control hub.
    3
    Secure the rack mounting brackets to
    the sides of the multi control hub using
    the supplied mounting screws (a
    4).
    4
    Mount the multi control hub in the rack
    and secure it in place using four rack
    mounting screws (part number W2-
    MSS/5008).
    SwitchboxTo mount the switchbox on a rack, use the
    supplied rack mounting brackets and
    mounting screws (M4a
    8).
    Power switch
    Rack mounting bracket
    Rack mounting screws
    W2-MSS/5008
    (Option)Mounting screws
    Rack mounting bracket
    Mounting screws Feet
    
    ORack mounting screws sold separately (part number W2-MSS/5008).
    OTo ensure that the temperature within the rack does not exceed +113°F (+45°C), make
    sure to provide sufficient space (a minimum of one chassis width between units)
    between the multi control hub and the other pieces of equipment mounted in the rack
    or install a cooling fan.
    Weight and dimensions indicated are
    approximate.
    Specifications are subject to change
    without notice. 
    						