Chapter 4 Settings — [NETWORK] menu ENGLISH - 101 Contents of mail sent Example of E-mail sent when E-mail is set The following E-mail is sent when the E-mail settings have been establis\ hed. === Panasonic projector report(CONFIGURE) === Projector Type : RW330 Serial No : SW1234567 ----- E-mail setup data ----- TEMPERATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INTAKE AIR TEMPERATURE Over [ 46 degC / 114 degF ] ERROR [ ON ] INTAKE AIR TEMPERATURE [ OFF ] PERIODIC REPORT Sunday [ ON ] Monday [ ON ] Tuesday [ ON ] Wednesday [ ON ] Thursday [ ON ] Friday [ ON ] Saturday [ ON ] 00:00 [ ON ] 01:00 [ ON ] 02:00 [ ON ] 03:00 [ ON ] 04:00 [ ON ] 05:00 [ ON ] 06:00 [ ON ] 07:00 [ ON ] 08:00 [ ON ] 09:00 [ ON ] 10:00 [ ON ] 11:00 [ ON ] 12:00 [ ON ] 13:00 [ ON ] 14:00 [ ON ] 15:00 [ ON ] 16:00 [ ON ] 17:00 [ ON ] 18:00 [ ON ] 19:00 [ ON ] 20:00 [ ON ] 21:00 [ ON ] 22:00 [ ON ] 23:00 [ ON ] ----- check system ----- MAIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] INTERNAL AIR TEMPERATURE [ OK ] LIGHT STATUS [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] OPTICS MODULE TEMP.SENSOR [ OK ] INTERNAL AIR TEMP.SENSOR [ OK ] BATTERY [ OK ] PHOSPHOR WHEEL [ OK ] (Error code 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00) Intake air temperature :[ 18 degC / 64 degF ] Optics module temperature :[ 30 degC / 86 degF ] Internal air temperature :[ 28 degC / 82 degF ] PROJECTOR RUNTIME 9 H -------- Current status -------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 POWER STATUS POWER=STANDBY INPUT SIGNAL DVI-D SIGNAL NAME XGA60 SIGNAL FREQUENCY 48.36kHz / 60.00H ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.0.8 MAC address 04:20:9A:00:00:00 Mon Jul 05 14:11:29 2012 ----- Memo -----

Chapter 4 Settings — [NETWORK] menu 102 - ENGLISH Example of the E-mail sent for an error The following E-mail is sent when an error has occurred. === Panasonic projector report(ERROR) === Projector Type : RW330 Serial No : SW1234567 ----- check system ----- MAIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] INTERNAL AIR TEMPERATURE [ OK ] LIGHT STATUS [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] OPTICS MODULE TEMP.SENSOR [ FAILED ] INTERNAL AIR TEMP.SENSOR [ OK ] BATTERY [ OK ] PHOSPHOR WHEEL [ OK ] (Error code 00 00 00 00 00 00 00 00 00 00 00 02 00 00 00 00) Intake air temperature :[ 18 degC / 64 degF ] Optics module temperature :[ 30 degC / 86 degF ] Internal air temperature :[ 28 degC / 82 degF ] PROJECTOR RUNTIME 9 H -------- Current status -------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 POWER STATUS POWER=STANDBY INPUT SIGNAL DVI-D SIGNAL NAME XGA60 SIGNAL FREQUENCY 48.36kHz / 60.00H ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.0.8 MAC address 04:20:9A:00:00:00 Mon Jul 05 14:11:29 2012 ----- Memo ----- [ECO management set up] page You can make settings for the ECO management function of the projector. Click [Detailed set up] → [ECO management set up]. 1 2 3 4 5 6 7 1 [LIGHT POWER] Select the light source power setting. 2 [AUTO POWER SA VE] Select [ON] to set [AMBIENT LIGHT DETECTION], [SIGNAL DETECTION], and [AV MUTE DETECTION]. 3 [AMBIENT LIGHT DETECTION] Enable ([ON])/disable ([OFF]) the ambient light detection function. 4 [SIGNAL DETECTION] Enable ([ON])/disable ([OFF]) the signal detection function. 5 [AV MUTE DETECTION] Enable ([ON])/disable ([OFF]) the AV mute detection function. 6 [NO SIGNAL SHUT -OFF] Select the time until the projector enters the standby mode when the signal detection function is used. 7 [Submit] Update the setting. Note f For detailed description of each setting item, refer to the [PROJECTOR SETUP] menu of the projector → [ECO MANAGEMENT] ( x page 70).

Chapter 4 Settings — [NETWORK] menu ENGLISH - 103 User name [Change password] page Click [Change password]. 1 2 3 1 [Administrator] Used to change the setting of [Administrator]. 2 [User] Used to change the setting of [User]. 3 [Next] Used to change the setting of the password. [Administrator] account 1 2 3 4 5 6 7 1 [Account] Displays the account to change. 2 [Current][User name] Enter the user name before the change. 3 [Current][Password] Enter the current password. 4 [New][User name] Enter the desired new user name. (Up to 16 characters in single byte) 5 [New][Password] Enter the desired new password. (Up to 16 characters in single byte) 6 [New][Password(Retype)] Enter the desired new password again. 7 [OK] Determines the change of password.

Chapter 4 Settings — [NETWORK] menu 104 - ENGLISH [User] account 1 2 3 5 4 1 [Account] Displays the account to change. 2 [New][User name] Enter the desired new user name. (Up to 16 characters in single byte) 3 [New][Password] Enter the desired new password. (Up to 16 characters in single byte) 4 [New][Password(Retype)] Enter the desired new password again. 5 [OK] Determines the change of password. [Change password] (for user rights) Only the change of password is enabled under the user rights. 1 2 4 3 1 [Old Password] Enter the current password. 2 [New Password] Enter the desired new password. (Up to 16 characters in single byte) 3 [Retype] Enter the desired new password again. 4 [OK] Determines the change of password. Note f To change the account of the administrator, you must enter the [Current] [User name] and [Password].

Chapter 4 Settings — [NETWORK] menu ENGLISH - 105 [CRESTRON RoomView] page The projector can be monitored and/or controlled with RoomView. To start the RoomView control page from the web control screen, you need to access with the administrator rights. (For user rights, the [CRESTRON RoomView] button is not displayed on the web control screen.) The control page of RoomView is displayed by clicking [CRESTRON RoomView]. It is not displayed if Adobe Flash Player is not installed on the computer used, or the browser\ used does not support Flash. In that case, click [Back] on the control page to go back to the previous page. Control page 1 2 3 4 5 6 7 1 [Tools][Info][Help] Tabs for selecting the setting, information, or help page of the projector. 2 [POWER] Switches the power on/off. 3 [VOL DOWN]/[A V MUTE]/[VOL UP] Operate the volume/AV mute. These operations are not available when the power of the projector is turned off. 4 [Input Select] Controls input selection. Not available when the power of the projector is turned off. 5 Menu screen control buttons Navigates the menu screen. 6 Freeze/image quality adjustment Controls items related to freeze/image quality. 7 [Back] Performs return to the previous page. [Tools] page Click [Tools] on the control page. 1 2 3 4 5 1 [Control System] Set the information required for communicating with the controller to be connected with the projector. 2 [User Password] Set the user rights password for the RoomView control page. 3 [Admin Password] Set the administrator rights password for the RoomView control page. 4 Network Status Displays the settings of wired LAN. [DHCP] Displays the current setting. [IpAddress] Displays the current setting. [SubnetMask] Displays the current setting. [DefaultGateway] Displays the current setting. [DNSServer] Displays the current setting. 5 [Exit] Returns to the control page.

Chapter 4 Settings — [NETWORK] menu 106 - ENGLISH [Info] page Click [Info] on the control page. 45 6 7 1 2 3 8 1 [Projector Name] Displays the projector name. 2 [Mac Address] Displays the MAC address. 3 [Lamp Hours] Displays the cumulative operating time (converted value) of the projector. 4 [Power Status] Displays the status of the power. 5 [Source] Displays the selected image input. 6 [Lamp Mode] Displays the light source mode. 7 [Error Status] Displays the error status. 8 [Exit] Returns to the control page. [Help] page Click [Help] on the control page. The [Help Desk] window is displayed. 1 1 [Help Desk] Messages can be sent to or received from an administrator who uses Crestron RoomView .

Chapter 4 Settings — [DIGITAL LINK] menu ENGLISH - 107 [DIGITAL LINK] menu On the menu screen, select [DIGITAL LINK] from the main menu. Refer to “Navigating through the menu” ( x page 41) for the operation of the menu screen. Switch the input to DIGITAL LINK. Note fWhen the optional digital interface box (Model No.: ET-YFB100G) is connected to the terminal, the main menu of ET-YFB100G is displayed. Refer to the user manual supplied with ET-YFB100G for details. f When a twisted-pair-cable transmitter of other company is connected to t\ he projector, the main menu of the projector is displayed.

108 - ENGLISH Chapter 5 Maintenance This chapter describes inspection when there are problems, and maintenan\ ce methods.

Chapter 5 Maintenance — Light source/temperature indicator ENGLISH - 109 Light source/temperature indicator Managing the indicated problems If a problem should occur inside the projector, the light source indicator /temperature indicator will i\ nform you by lighting or flashing. Check the status of the indicators and manage the indicated problems as \ follows. Attention fWhen switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” ( x page 34). fCheck the status of the power supply with the power indicator . ( x page 32) /LJKWVRXUFHLQGLFDWRU/,*+7!3RZHULQGLFDWRU21*67$1%

Chapter 5 Maintenance — Light source/temperature indicator 110 - ENGLISH Temperature indicator Indicator statusLighting in redFlashing in red (1 time) Flashing in red (2 time) Flashing in red (3 time) Status Warm-up status Internal temperature is high (warning).Internal temperature is high (during projection).Internal temperature is high (standby warning). The fan has stopped. Cause f Did you turn on the power when the room temperature was low (about 0 °C (32 °F))? f Is the air intake/exhaust port blocked? fIs the room temperature high? ― Solution f Wait at least five minutes in the current status. fInstall the projector in a location with an ambient temperature of 0 °C (32 °F) to 45 °C (1 13 °F)*1. fRemove any objects that are blocking the air intake/exhaust port. fSet up the projector in a location with an ambient temperature of 0 °C (32 °F) to 45 °C (1 13 °F)*1, and a humidity of 20 % to 80 % (no condensation). f Do not use the projector at high elevations 2 700 m (8 858') or higher above sea level. fSet the switch to ( x page 34), and consult your dealer . *1 When using the projector at high altitudes (1 400 m (4 593') – 2 700 m (8 858') above sea level), the ambient temperature will be 0 °C (32 °F) – 40 °C (104 °F). Note f If the temperature indicator is still lit or flashing after taking the preceding measures, ask your dealer to repair the projector .