Chapter 6 Maintenance — [SELF TEST] indications ENGLISH - 181 Error/warning displayDetailsAction number FF0 Radiator fan 2 error 5 FF1 Radiator fan 1 error 5 FH0 Phosphor wheel 1 error 5 FH1 5 FH2 Phosphor wheel 2 error 5 FH3 5 FJ0 Liquid cooling pump 1 error 5 FJ1 Liquid cooling pump 2 error 5 FL1 Light source 1 unit error 6 FL2 Light source 2 unit error 6 Note fThe self-diagnosis display and the details of the malfunction may be dif\ ferent. fFor errors and warnings that are not described in the table, consult you\ r dealer . rMeasure for error and warning Action number Measure 1 The operating environment temperature is too high. Use the projector in \ an appropriate operating environment temperature *1. 2 The operating environment temperature is too low. Use the projector in an appropriate operating environment temperature *1. 3 The input supply voltage is low. Use electric wiring that can sufficiently withstand the power consumption of the projector. 4 Battery replacement is required. Consult your dealer. 5 If the display does not clear after switching the main power off and on, consult your dealer. 6 The light source has failed to turn on. If the light source does not lig\ ht up after turning the power off and on, consult your dealer. *1 For details of operating environment temperature of the projector , refer to “Operating environment temperature” (x page 203).

182 - ENGLISH Chapter 7 Appendix This chapter describes specifications and after-sales service for the projector.

Chapter 7 Appendix — Technical information ENGLISH - 183 Technical information PJLink protocol The network function of this projector supports the PJLink class 1, and the PJLink protocol can be used to perform projector setting and projector status query operations from a computer. Control commands The following table lists the PJLink protocol commands that can be used to control the projector . fx characters in tables are non-specific characters. Command Control details Parameter/response string Remark POWR Power supply control 0 Standby 1 Power on POWR? Power supply status query 0 Standby 1 Power on 2 Preparing for switching off the projector 3 Warm-up INPT Input selection 11 RGB1 12 RGB2 INPT? Input selection query 31DVI - D 32 HDMI 33 DIGITAL LINK 34 SDI (Only for PT - RZ770, PT - RZ660) AVMT Shutter control 30Shutter function disabled (shutter: open) AVMT? Shutter status query 31Shutter function enabled (shutter: closed) ERST? Error status query xxxxxx 1st byte Indicates fan errors, and returns 0 - 2. f 0 = No error is detected f1 = W arning f2 = Error 2nd byte Indicates light source errors, and returns 0 - 2. 3rd byte Indicates temperature errors, and returns 0 - 2. 4th byte Returns 0. 5th byte Indicates filter errors, and returns 0 - 2. 6th byte Indicates other errors, and returns 0 - 2. LAMP? Light source status query xxxxxxxxxxxx 1st number (1 - 5 digits): Light source 1 runtime 2nd number: 0 = Light source 1 of f, 1 = Light source 1 on 3rd number (1 - 5 digits): Light source 2 runtime 4th number: 0 = Light source 2 off, 1 = Light source 2 on INST? Input selection list query 11 12 31 32 33 34 Only for PT - RZ770, PT - RZ660 11 12 31 32 33 Only for PT - RW730, PT - RW620 NAME? Projector name query xxxxx Returns the name set in [PROJECTOR NAME] of [NETWORK SETUP]. INF1? Manufacturer name query Panasonic Returns manufacturer name. INF2? Model name query RZ770 RW730 RZ660 RW620Returns model name. INF0? Other information queries xxxxx Returns version number. CLSS? Class information query 1Returns class for PJLink.

Chapter 7 Appendix — Technical information 184 - ENGLISH PJLink security authentication The password used for PJLink is the same as that of the password set for web control. When using the projector without security authentication, do not set a p\ assword for web control. fFor specifications related to PJLink, visit the website of Japan Business Machine and Information System Industries Association. URL http://pjlink.jbmia.or.jp/english/ Using Art-Net function Since the network function of the projector supports the Art-Net function, you can control the projector settings with the DMX controller and application software using the Art-Net protocol. Channel definition The following table lists the channel definitions used for controlling the projector with the Art-Net function. Channel settings can be switched using the [NETWORK] menu → [Art-Net CHANNEL SETTING] (x page 152). The control details assigned to each channel are listed in the following\ table. f Channel assignment for [USER] is in factory default setting. Assignment can be changed. Channel Control details [2] [USER] [1] CHANNEL1 LIGHT OUTPUT LIGHT OUTPUT SHUTTER CHANNEL2 INPUT SELECT INPUT SELECT INPUT SELECT CHANNEL3 LENS POSITION LENS POSITIONLENS FUNCTION SELECT CHANNEL4 LENS H SHIFT LENS H SHIFTLENS CONTROL CHANNEL5 LENS V SHIFT LENS V SHIFT POWER CHANNEL6 LENS FOCUS LENS FOCUSLIGHT OUTPUT CHANNEL7 LENS ZOOM LENS ZOOMENABLE/DISABLE CHANNEL8 POWERPOWER FADE-IN CHANNEL9 GEOMETRY GEOMETRY FADE-OUT CHANNEL10 CUSTOM MASKING *1CUSTOM MASKING*1CUSTOM MASKING*1 CHANNEL11 ENABLE/DISABLE ENABLE/DISABLE GEOMETRY CHANNEL12 NONENONE NONE *1 For PT-RZ770, PT- RZ660. The setting for PT- RW730 or PT- RW620 is “NONE”. Control details rLIGHT OUTPUT This can be set in 256 steps between 100 % and 0 %. Performance ParameterDefault value 100 % 0 0 … … 0 % 255

Chapter 7 Appendix — Technical information ENGLISH - 185 rINPUT SELECT (when [Art-Net CHANNEL SETTING] is set to [1]) Performance ParameterDefault value No operation 0 - 7 0 RGB1 8 - 15 RGB2 16 - 23 No operation 24 - 31 DVI - D 32 - 39 HDMI 40 - 47 DIGITAL LINK 48 - 55 SDI (Only for PT - RZ770, PT - RZ660) 56 - 63 No operation 64 - 127 P IN P execution, USER1 128 - 135 P IN P execution, USER2 136 - 143 P IN P execution, USER3 144 - 151 No operation 152 - 255 rINPUT SELECT (when [Art-Net CHANNEL SETTING] is set to [2] or [USER]) Performance ParameterDefault value No operation 0 - 7 0 RGB1 8 - 15 RGB2 16 - 23 DVI - D 24 - 31 HDMI 32 - 39 DIGITAL LINK 40 - 47 SDI (Only for PT - RZ770, PT - RZ660) 48 - 55 No operation 56 - 119 P IN P OFF 120-127 P IN P execution, USER1 128 - 135 P IN P execution, USER2 136 - 143 P IN P execution, USER3 144 - 151 No operation 152 - 255 rLENS POSITION Performance ParameterDefault value No operation 0 - 31 0 Move to the home position *132-63 Move to the ET- DLE030 lens standard position*2 No operation 64 - 255 *1 Operation when [NORMAL] is selected in [HOME POSITION] in the [HOME POSITION] screen *2 Operation when [DLE030] is selected in [HOME POSITION] in the [HOME POSITION] screen rLENS H SHIFT , LENS V SHIFT, LENS FOCUS, LENS ZOOM Performance ParameterDefault value Lens adjustment ( -) High speed 0 - 31 128 ( -) Low speed 32 - 63 ( -) Fine adjustment 64 - 95 Operation stop 96 - 159 Lens adjustment (+) Fine adjustment 160 - 191 (+) Low speed 192 - 223 (+) High speed 224 - 255

Chapter 7 Appendix — Technical information 186 - ENGLISH rLENS FUNCTION SELECT (when [Art-Net CHANNEL SETTING] is set to [1]) Operate together with LENS CONTROL. PerformanceParameterDefault value No operation 0 - 15 0 LENS H SHIFT 16 - 31 LENS V SHIFT 32 - 47 LENS FOCUS 48 - 63 LENS ZOOM 64 - 79 Move to the home position *180-95 Move to the ET- DLE030 lens standard position*2 No operation 96 - 255 *1 Operation when [NORMAL] is selected in [HOME POSITION] in the [HOME POSITION] screen *2 Operation when [DLE030] is selected in [HOME POSITION] in the [HOME POSITION] screen rLENS CONTROL (when [Art-Net CHANNEL SETTING] is set to [1]) Operate together with LENS FUNCTION SELECT. Performance ParameterDefault value Lens adjustment ( -) High speed 0 - 31 100 ( -) Low speed 32 - 63 ( -) Fine adjustment 64 - 95 Operation stop 96 - 127 Lens adjustment (+) Fine adjustment 128 - 159 (+) Low speed 160 - 191 (+) High speed 192 - 223 Execute command action 224 - 255 rPOWER Performance ParameterDefault value Standby 0 - 63 128 No operation 64 - 191 Power on 192 - 255 rSHUTTER Performance ParameterDefault value SHUTTER: Open 0 - 63 128 No operation 64 - 191 SHUTTER: Closed 192 - 255 rFADE ‑ IN, FADE ‑ OUT (when [Art ‑ Net CHANNEL SETTING] is set to [1] or [USER]) Operate together with SHUTTER. Performance ParameterDefault value OFF 0 - 15 255 0.5s 16 - 31 1.0s 32 - 47 1.5s 48 - 63 2.0s 64 - 79 2.5s 80 - 95 3.0s 96 - 111 3.5s 112 - 127 4.0s 128 - 143 5.0s 144 - 159 7.0s 160 - 175 10.0s 176 - 191 No operation 192 - 255

Chapter 7 Appendix — Technical information ENGLISH - 187 rGEOMETR Y Performance ParameterDefault value OFF 0 - 15 255 KEYSTONE 16 - 31 CURVED CORRECTION 32 - 47 PC-1 *148-63 PC-2 *164-79 PC-3 *180-95 CORNER CORRECTION 96 - 111 No operation 112 - 255 *1 Only for PT- RZ770, PT- RZ660 rCUSTOM MASKING (Only for PT‑RZ770, PT‑RZ660) To use PC-1, PC-2, or PC-3, the optional Upgrade Kit (Model No.: ET- UK20) is required. PerformanceParameterDefault value OFF 0 - 31 255 PC-1 32 - 63 PC-2 64 - 95 PC-3 96 - 127 No operation 128 - 255 rFREEZE Performance ParameterDefault value No operation 0 - 31 128 OFF 32 - 95 No operation 96 - 159 ON 160 - 223 No operation 224 - 255 rCOLOR, TINT Performance ParameterDefault value No operation 0 - 31 0 Factory default setting 32 - 63 -31 64 - 65 … … 0 128 - 129 … … +31 190 - 191 No operation 192 - 255 rRASTER P ATTERN Performance ParameterDefault value No operation 0 - 15 0 OFF 16 - 31 WHITE 32 - 47 YELLOW 48 - 63 CYAN 64 - 79 GREEN 80 - 95 MAGENTA 96 - 111 RED 112 - 127 BLUE 128 - 143 BLACK 144 - 159 USER LOGO 160 - 175 No operation 176 - 255

Chapter 7 Appendix — Technical information 188 - ENGLISH rENABLE/DISABLE Operation for all channels is not accepted when set to “Disable”. Performance ParameterDefault value Disable 0 - 127 0 Enable 128 - 255 Note fIf the projector is operated using the remote control or the control pan\ el, or by the control command while controlling the projector using the \ Art-Net function, the setting of the DMX controller or computer application may be dif ferent from the projector status. To reflect the controls of all channels to the projector, set “ENABLE/DISABLE” of channel 11 to “Disable” and then back to “Enable”. f T o create/register the USER LOGO image, use “Logo Transfer Software” included in the supplied CD-ROM. Control commands via LAN When web control administrator rights password is set (Protect mode) Connecting 1) Obtain the IP address and port number (Initial set value = 1024) of the projector a\ nd request a connection to the projector. f Y ou can obtain both the IP address and the port number from the menu screen of the projector. IP address Obtain from the [NETWORK] menu → [NETWORK STATUS]. Port number Obtain from the [NETWORK] menu → [NETWORK CONTROL] → [COMMAND PORT]. 2) Check the response from the projector. Data section Blank Mode Blank Random number section Termination symbol Command example “NTCONTROL” (ASCII string) ‘ ’ 0x20 ‘1’ 0x31 ‘ ’ 0x20 “zzzzzzzz” (ASCII code hex number) (CR) 0x0d Data length 9 bytes 1 byte 1 byte 1 byte8 bytes1 byte fMode: 1 = Protect mode fExample: Response during protect mode (random number section is undefined value) “NTCONTROL 1 23181e1e” (CR) 3) Generate a 32-byte hash value from the following data using MD5 algorith\ m. f “xxxxxx:yyyyy:zzzzzzzz” xxxxxx Administrator rights user name for the web control (default user name is “admin1”) yyyyy Password of above administrator rights user (default password is “panasonic”) zzzzzzzz 8-byte random number obtained in Step 2)

Chapter 7 Appendix — Technical information ENGLISH - 189 Command transmission method Transmit using the following command formats. r Transmitted data Header Data sectionTermination symbol Command example Hash value “Connecting” ( x page 188) ‘0’ 0x30 ‘0’ 0x30 Control command (ASCII string) (CR) 0x0d Data length 32 bytes 1 byte 1 byteUndefined length 1 byte fExample: Transmission of power supply status acquisition command (hash value is calculated from default user name, password, and acquired random number) “dbdd2dabd3d4d68c5dd970ec0c29fa6400QPW” (CR) r Received data Header Data sectionTermination symbol Command example ‘0’ 0x30 ‘0’ 0x30 Control command (ASCII string) (CR) 0x0d Data length 1 byte 1 byte Undefined length 1 byte fExample: The projector is powered on “00001” (CR) r Error response String DetailsTermination symbol Message “ERR1” Undefined control command (CR) 0x0d “ERR2” Out of parameter range “ERR3” Busy state or no-acceptable period “ERR4” Timeout or no-acceptable period “ERR5” Wrong data length “ERRA” Password mismatch Data length 4 bytes ―1 byte When web control administrator rights password is not set (Non-protect \ mode) Connecting 1) Obtain the IP address and port number (Initial set value = 1024) of the projector a\ nd request a connection to the projector. f Y ou can obtain both the IP address and the port number from the menu screen of the projector. IP address Obtain from the [NETWORK] menu → [NETWORK STATUS]. Port number Obtain from the [NETWORK] menu → [NETWORK CONTROL] → [COMMAND PORT]. 2) Check the response from the projector. Data sectionBlankModeTermination symbol Command example “NTCONTROL” (ASCII string) ‘ ’ 0x20 ‘0’ 0x30 (CR) 0x0d Data length 9 bytes 1 byte1 byte1 byte fMode: 0 = Non-protect mode fExample: Response during non-protect mode “NTCONTROL 0” (CR)

Chapter 7 Appendix — Technical information 190 - ENGLISH Command transmission method Transmit using the following command formats. r Transmitted data Header Data sectionTermination symbol Command example ‘0’ 0x30 ‘0’ 0x30 Control command (ASCII string) (CR) 0x0d Data length 1 byte 1 byte Undefined length 1 byte fExample: Transmission of power supply status acquisition command “00QPW” (CR) r Received data Header Data sectionTermination symbol Command example ‘0’ 0x30 ‘0’ 0x30 Control command (ASCII string) (CR) 0x0d Data length 1 byte 1 byte Undefined length 1 byte fExample: The power of the projector is in standby status “00000” (CR) r Error response String DetailsTermination symbol Message “ERR1” Undefined control command (CR) 0x0d “ERR2” Out of parameter range “ERR3” Busy state or no-acceptable period “ERR4” Timeout or no-acceptable period “ERR5” Wrong data length “ERRA” Password mismatch Data length 4 bytes ―1 byte