    							41
    ENGLISH
    Cleaning and replacement of air filter
    If too much dust accumulates on the air filter, [AIR FILTER] appears at the lower left of the screen, and the
    temperature monitor (TEMP) will blink once. If even more dust is allowed to accumulate, the temperature inside the
    main unit will rise, the temperature monitor (TEMP) will blink twice, and the power is turned off.
    Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector
    operation.
    It appears only for 30 seconds within 3 minutes after the power is turned on. It disappears if any of the buttons
    on the rear side of the main unit or on the remote control is pressed.
    Procedure of cleaning
    Turn off the main power and remove the power plug from the receptacle.
    Turn off the main power supply observing the procedure (Powering off the projector) on page 23 and then
    remove the power plug.
    Dismantle the air filter.
    There are two air filters, one at the left and one at the right.
    Use your finger to pull the air filter tab toward you, and remove it from the main unit.
    Set the air filter.
    Set the air filter in the reverse order to step  .
    Clean the air filter.
    Suck off deposited dust with a vacuum cleaner.
    • Do not to suck in the air filter itself.
    • Do not rinse off the air filter with water. Doing so will impair the filter’s ability to provide
    protection from dust.Attention
    • Fit the air filters into place with the filter material facing the back.
    (The left and right filters have the same shape.)
    • The air filter must be fitted in place when using the projector.
    Using the projector without the air filter fitted inside, dirt and dust are sucked into the projector,
    causing failure.Attention
    • If cleaning cannot remove the dust completely, then it is a sign to replace the air filter. Consult the
    dealer. In addition, when the lamp unit is replaced, also replace the air filter.
    • Be absolutely sure to use the air filter specifically designed for use with the projector.Note
    Air filter 
    						
    							42
    Replacing the lamp unit
    Precautions on lamp unit replacement
    Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.
    Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled,
    explosion might result.
    A used lamp unit may burst if it is handled violently.
    For disposition of used lamps, request an industrial waste disposal contractor.
    Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit.
    If you continue to use a lamp after the replacement time, the lamp may break.
    Phillips screwdriver is necessary when replacing a lamp unit.
    Take care not to slip your hand when using a screwdriver.
    • A lamp unit is an optional part. Contact the dealer.
    Replacement lamp unit model No.: ET-LAD55 (single bulb), ET-LAD55W (double bulbs)
    Rating: 300W
    Long life lamp unit model No.: ET-LAD55L (single bulb), ET-LAD55LW (double bulbs)
    Rating: 160W
    • Other lamps than specified above cannot be used. Be sure to use the specified lamp.Attention
    Timing of lamp unit replacement
    The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500
    hours1(when “LAMP POWER” is “HIGH” and “LAMP  SELECT” is “DUAL”). However, it may happen that the
    lamp becomes dead (will not light) by the time of 1 500 hours1depending on the characteristics of individual
    lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals
    between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare
    bulb.
    If your lamp unit is not replaced after 1 300 hours
    2(with “LAMP POWER” set at “HIGH”), power supply will be
    turned off automatically at the time of 1 500 hours1, entering a standby state. After 1 500 hours1of initial
    lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is
    turned on again.
    Indication after 1 300 hours2(with “LAMP POWER” set at “HIGH”)
    When lamp unit used hours have reached 1 300 hours2, lamp monitor
    (LAMP1 or LAMP2) light up including standby state.
    Further, an on-screen indication will appear for about 30 seconds as
    shown in the diagram on the left, recommending replacement of lamp unit.
    (The indication on the left diagram will disappear after about 30 seconds or
    when either control button on the rear of main unit or remote control button
    is operated.)
    After the time of 1 500 hours
    1, the on-screen indication will not disappear
    unless the menu (MENU) button is operated.
    REPLACE LAMP
    1 This time period is 4 000 hours when long life lamp units are used.
    2 This time period is 3 800 hours when long life lamp units are used.
    WARNING!
    When replacing the lamp, allow it to 
    cool for at least one hour before 
    handling it. 
    						
    							43
    ENGLISH
    Lamp unit replacement steps
    • After 1 500 hours (4 000 hours when long life lamp units are used) of operating the same lamp, it
    is only possible to operate the unit for approximately 10 minutes. Steps  to  must be
    completed within 10 minutes.Attention
    Turn the power off by following the steps on page 23, remove the power plug and
    confirm that the surroundings of the lamp unit have cooled off.
    Check that the fan has stopped running.
    Have a Phillips screwdriver ready ahead of time.
    Remove the screw securing the lamp unit
    cover, and then slide the lamp unit cover
    a little toward the left, and remove it.
    Remove the two screws securing the
    fan unit.
    Lamp unit cover
    Open the fan unit as shown in the
    figure.
    Remove the screws securing the lamp
    units (two for each unit), take hold of
    the handles, and remove the lamp units.
    Install the new lamp unit.
    Use a Phillips screwdriver to securely
    tighten the 2 lamp unit fixing screws
    (two for each unit).
    Lamp unit 2
    Handle
    Lamp unit 1 Lamp unit
    Fixing screws
    Secure the two screws for securing the
    fan unit tightly.
    Slide the cover a little toward the right,
    and secure it using the screw for
    securing the lamp unit cover tightly.
    • Firmly install the lamp unit and lamp
    unit cover. If not installed firmly, a
    protection circuit will function and the
    power will not be turned on.Attention
    • The lamp units are constructed in such
    a way that the screws in steps  and
    will not fall through completely.Note
    Caution
    The lamp unit will be hot after it has
    been used.
    You might get burned if you touch it while it is
    still hot.
    (Continued on next page) 
    						
    							44
    Insert the power cord plug into the wall outlet and then
    press the MAIN POWER switch.
    Press the “ I ” button so that a picture is projected onto
    the screen.
    Press the “MENU” button to display the MAIN MENU
    screen, and then press the  and  buttons to move
    the cursor to select “OPTION2”.
    Press the “ENTER” button to display the “OPTION2”
    screen, and select “SYSTEM INFORMATION” with the 
    and buttons.
    Press the “ENTER” button.
    The SYSTEM INFORMATION screen will be displayed.
    Press and hold the “ENTER” button on the projector or
    the remote control for approximately 3 seconds.
    An item “LAMP TIME RESET” will be added.
    Select the lamp which has been replaced with the  and
    buttons. 
    LAMP1: Replace the LAMP UNIT 1
    LAMP2: Replace the LAMP UNIT 2
    Press the ENTER button, and when the “LAMP TIME
    RESET” display flashes, press the ENTER button again.
    The used hours of the specified lamp unit will be reset to zero.
    When more than one lamp has been replaced, repeat the procedure from
    step .
    • If the power does not turn on even after turning the MAIN
    POWER switch “I”, turn the MAIN POWER “O”, confirm that
    the lamp unit and door are installed correctly, and turn on
    again.Attention
    MENU
    PICTURE
    ADVANCED MENU
    OPTI0N2
    TEST PATTERN OPTION1 POSITION
    LANGUAGE
    LAMP TIME RESET
    LAMP1
    LAMP2
      LAD55
      LAD55L   LAD55
    1433h
    0h
    1100h
    0h   LAD55L
    SYSTEM INFORMATION
    ROM VERSION
              HIGH
    200h
            TOTAL
    300h
    LAMP2 LOW SET RUNTIME
    300h
    LAMP1 LOW
    100h
    100h 1. 00. 00
    • When the “LAMP TIME RESET” display flashes, the lamp
    time reset can be canceled by pressing the MENU button.
    • The used hours of the lamp units can also be reset to zero
    by taking the following action instead of steps  to  .
    When lamp unit 1 has been replaced:
    In the standby mode, press the number buttons in the
    sequence of 737381, and then press the ENTER button.
    When lamp unit 2 has been replaced:
    In the standby mode, press the number buttons in the
    sequence of 737382, and then press the ENTER button.
    When the used hours have been reset, the lamp monitor
    (LAMP1/LAMP2) will flash for 3 seconds.Note
    Replacing the lamp unit 
    						
    							45
    ENGLISH
    Using Web Browser Control 
    Accessing from the Web browser
    Start the web browser on your PC, then
    enter the IP address which was set in
    the projector.
    Enter “user1” in the user name field,
    then enter the password in the
    password field.
    The default setting is “panasonic” (all lower case). If
    you have changed the password, enter the new
    password here. 
    The host name set in the projector is displayed in
    the “Realm” field.
    Click [OK]. 
    The Basic Control page is displayed.
    Password change page
    Click [Change password].
    • Avoid activating two or more Web browser
    simultaneously to work out setting or
    control actions.
    • Change the password first of all.Note This projector has networking functions which allow it to be controlled through a web browser on a PC. 
    The controlled items are:
    • Projector’s settings and adjustment
    • Projector’s status display
    • Transmission of a E-mail message when the projector has a problem
    Old password input field
    New password input field
    New password input field
    (re-enter for confirmation)
    Button for executing password change
    Button for erasing all entered characters 
    						
    							46
    Using Web Browser Control 
    Basic control page
    This page is the first page displayed when the projector is accessed through a web browser.
    To move from another page, click [Projector control], then [Basic control]. 
    OSD
    (On-screen Display)
    display/non-display
    Use these to select
    the input signals.
    Signal System
    Switching
    Change password button
    Power On/Off control 
    Shutter control
    Control button
    Click this item, and a
    projector control page
    appears.
    E-mail set up button
    Click this item, and an E-
    mail setting page appears.
    Monitor information
    button
    Click this item, and the
    status of the projector is
    displayed.
    Network set up button
    Click this item, and a network set up page for IP address and other items appear. 
    						
    							47
    ENGLISH
    Monitor information page
    Click [Projector control], then [Status information] to display the Status information page.
    This page displays the projector statuses established for the items shown below.
    Detail control page
    Click [Projector control], then [Detail control] to display the Detail control page.
    Temporary stop of video
    Lens adjustment
    Test pattern display
    This button updates the
    on-screen description on
    the right of the control
    page with the latest
    information.
    Pressing these buttons controls the projector and updates the on-screen
    description on the right of the control page when control is finished.
    Displays the input
    switching status.
    Displays temperature of
    projector’s intake air.
    Displays temperature
    inside the projector.
    Displays temperature
    around the lamp.
    Displays the lamp1 lit
    hours.
    Displays the lamp2 lit
    hours.
    Displays used hours of the
    projector.
    Displays self-diagnosis
    information.
    Displays the type
    of projector.Displays the firmware version
    of the projector main unit.
    On-screen status is
    displayed, even if the on-
    screen of projector is set
    to off. 
    						
    							OK: Normal operation
    FAILED: Occurrence of trouble
    48
    Using Web Browser Control 
    Error information page
    When  is displayed on the status information screen, click it to display the error details.
    • Depending on the nature of the error, the projector may be placed in the standby mode for its own
    protection.Note
    When [FAILED] has appeared for an item
    Parameter
    MAIN CPU BUS
    FAN
    OPTICS MODULE
    TEMPERATURE
    INPUT AIR TEMPERATURE
    AROUND LAMP
    TEMPERATURE
    LAMP REMAIN TIME
    LAMP STATUS
    SHUTTER
    AIR FILTER
    OPTICS MODULE TEMP.SENSOR
    INPUT AIR TEMP.SENSOR
    AROUND LAMP 
    TEMP. SENSOR
    BATTERY
    AIRFLOW SENSOR
    COLOR WHEEL
    Description
    Trouble has occurred in the microcomputer circuitry. Consult your dealer.
    Trouble has occurred in the fan or its drive circuit. Consult your dealer.
    The temperature inside the projector is high. It may be that the projector is
    being used where the ambient temperature is high such as near a heating
    appliance.
    The input air temperature is too high. It may be that the projector is being
    used where the ambient temperature is high such as near a heating
    appliance.
    The temperature near the lamp has risen very high.
    Something may be blocking the exhaust vent.
    The lamp runtime has exceeded the prescribed cumulative time, and it is
    now time to replace the lamp.
    The lamp has failed to light.
    Wait a short while for the lamp to cool off, and then turn on the power.
    Trouble has occurred in the shutter circuitry. Consult your dealer.
    Too much dust accumulates on the air filter.  
    Turn off the MAIN POWER switch using the procedure on page 23 and
    clean the air filter (refer to page 41).
    Trouble has occurred in the temperature detection sensor inside the
    projector. Consult your dealer.
    Trouble has occurred in the sensor used to detect the input air temperature.
    Consult your dealer.
    Trouble has occurred in the temperature detection sensor around lamps.
    Consult your dealer.
    The backup battery has been run out. Consult your dealer.
    Trouble has occurred in the air volume sensor. Consult your dealer.
    Trouble has occurred in the colour wheel or the colour wheel drive circuit.
    Consult your dealer.  
    						
    							49
    ENGLISH
    E-mail setup page
    With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be
    sent to one or more preset e-mail addresses (maximum two addresses). Click [Projector Control], then [E-mail
    set up] to display the E-mail setup page.
    Select “Enable” to use
    the E-mail function.Enter the IP address or server name of the E-mail server (SMTP).
    The DNS server must be set if the server name is entered.
    Enter the E-mail address of the
    projector.
    (maximum 63 characters)
    The user can enter the location
    of, for example, the installed
    projector so that the recipient
    may easily identify the
    originator of the E-mail.
    (maximum 63 characters)
    The user can modify the threshold temperature for sending
    temperature warning mail. If the temperature rises above the set value,
    control sends temperature warning mail.
    Periodic warning interval setting
    (e-mail is sent on the checked
    days of the week/times)
    (Continued on next page)
    The user can modify the
    minimum time interval of
    temperature warning mail.  The
    default value is 60 minutes.  In
    this case, the user cannot send
    another mail for 60 minutes
    after sending previous
    temperature warning mail even
    the set warning temperature is
    reached again.
    Enter the E-mail address of
    your desired recipient.
    Select the conditions for
    sending E-mail.
    ERROR:
    an error is detected by self-
    diagnosis.
    LAMP RUNTIME:remaining
    lamp service time has reached
    the value set in the field.
    INPUT AIR TEMPERATURE:
    intake air temperature has
    reached the value set in the field. 
    						
    							50
    Using Web Browser Control 
    DNS server set up page
    Click [Network set up], then [DNS server set up] to display the DNS server set up page.
    Enter the E-mail address to
    which the E-mail is to be sent
    when two E-mail addresses
    are going to be used. Do not
    enter it when the second E-
    mail address is not going to
    be used.
    Check these boxes when E-
    mail is to be sent periodically
    to two E-mail addresses. E-
    mail will be sent at the times
    and on the days checked.
    Button to update settings
    Button to update settings
    Primary DNS server
    address
    Available input characters:
    Numbers (0 - 9), period (.)
    (ex. 192.168.0.253)
    Secondary DNS server
    address
    Available input characters: 
    Numbers (0 - 9), period (.)
    (ex. 192.168.0.254)
    E-mail setup page (continuing)
    Select the conditions for sending the second E-mail.
    ERROR:an error is detected by self-diagnosis.
    LAMP RUNTIME:remaining lamp service time has reached the value set in the field.
    INPUT AIR TEMPERATURE: intake air temperature has reached the value set in the field.
    • Only alphanumeric characters, “.”, “_”, “-”, or “@” are available to set an e-mail address.Note 
    						