    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    TABLE 12 
    PROGRAM 
    07-AUTOMATIC RELEASE ON HOLD (AROH) TIMJNG 
    1. Operate SET switch on MCAU LED on MCAU on 
    Station 17 MW/FL LED on 
    System is in program mode 
    Normal functions halt on Station 17 
    2. Operate F[ key on Station 17 
    3. Dial m p[ on dial pad 
    To program CO 18 ~21, dial m R PI, 
    then CO 1~4 = CO 18~21. 
    4. Refer to the System Record Sheet. 
    Using the m keys, turn the associated 
    LEDs on or off, as required. Each CO 
    key/LED represents itself-that is, if 
    CO 1 LED is on, CO 1 will use XB 
    (crossbar) timing for AROH. If CO 1 
    LED is off, ESS timing will be used 
    on that line. 
    5. Operate the / key to place 
    new data in memory. 
    6A. Return to Step 2 in order to continue 
    with this program 
    . ..or... SPKR LED steady on 
    SPKR LED flashes continuously 
    CO LEDs will be on according 
    to present data 
    An X on the record sheet means the LE.D 
    should be on 
    If the LED is already on, pushing 
    the associated key will turn it 
    off and vice-versa 
    LEDs may be turned off and on 
    until the desired pattern is set 
    All Station 17 LEDs (except MW/FL) 
    go off 
    6B. Go to Step 2 in another program table 
    . ..or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/FL LED goes off 
    New data is stored, previous data is erased 
    NOTE: 
    This program will have no meaning unless A ROH is enabled via Program 06. 
    -38-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    TABLE 13 
    PROGRAM 08 -TENANT SERVICE SELECTION . . 
    LED on MCAU on 
    1. Operate SET switch on MCAU Station 17 MW/FL LED on 
    System is in program mode 
    Normal functions halt on Station 17 
    2. Operate ‘a key on Station 17 
    3. Dial 
    q q on dial pad 
    To program CO 18~21, dial 
    q q q , 
    then CO 1~4 = CO 18~21. SPKR LED steady on 
    SPKR LED flashes continuously 
    CO LEDs will be on according 
    to present data 
    4. Refer to the System Record Sheet. 
    An X on the record sheet means the LED 
    Using the m keys, turn the associated 
    should be on 
    LEDs on or off, as required. Each CO 
    If the LED is already on, pushing 
    key/LED represents itself-that is, if 
    the associated key will turn it 
    CO 1 LED is on, CO 1 will belong to off and vice-versa 
    tenant #2. If CO 1 LED is off, CO 1 
    LEDs may be turned off and on 
    will belong to tenant #l. 
    until the desired pattern is set 
    5. Operate the !F] key to place All Station 17 LEDs (except MW/F L) 
    new data in memory. go off 
    6A. Return to Step 2 in order to continue 
    with this program 
    . ..or... 
    6B. Go to Step 2 in another program table 
    . . . or . . . 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/FL LED goes off 
    New data is stored, previous data is erased 
    NO TE: 
    This program will have no meaning unless Tenant Service was selected in Program 03. 
    -39-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 
    1983 
    TABLE 14 
    PROGRAM 09-CO 
    LINE “DIAL 9” GROUP SELECTION.- 
    1. Operate SET switch on MCAU LED on MCAU on 
    Station 17 MW/FL LED on 
    System is in program mode 
    Normal functions halt on Station 17 
    2. Operate ;] key on Station 17 SPKR LED steady on 
    3. Dial m m on dial pad 
    To program CO 18 ~21, dial 
    q q q , 
    then CO 1%4= CO 18~21. SPKR LED flashes continuously 
    CO LEDs will be on according 
    to present data 
    4. Refer to the System Record Sheet. 
    Using the m keys, turn the associated 
    LEDs on or off, as required. Each CO 
    key/LED represents itself-that is, if 
    CO 1 LED is on, CO 1 will be included 
    in the “Dial 9” Group for random 
    selection by a single line (OPX) 
    extension. If CO 1 LED is off, 
    CO 1 can be accessed only by dialing 
    m [?J r;l at the OPX extension. An X on the record sheet means the LED 
    should be on 
    If the LEDs are already on, pushing 
    the associated key will turn 
    them off and vice-versa 
    LEDs may be turned off and on until 
    the desired pattern is set 
    5. Operate the /I key to place 
    new data in memory. All Station 17 LEDs (except MW/FL) 
    go off 
    6A. Return to Step 2 in order to continue 
    with this program 
    . ..or... 
    6B. Go to Step 2 in another program table 
    . ..or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/FL LED goes off 
    New data is stored, previous data is erased 
    -4o-  
    						
    							TABLE 15 
    PROGRAM lo-PBX BACK-UP SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    1. Operate SET switch on MCAU LED on MCAU on 
    Station 17 MW/FL LED on 
    System is in program mode 
    Normal functions halt on Station 17 
    2. Operate XI key on Station 17 SPKR LED steady on 
    3. Dial m w on dial pad 
    To program CO 18~21, dial m R fij, 
    then CO 1~4 = CO 18~21. SPKR LED flashes continuously 
    CO LEDs will be on according 
    to present data 
    * 
    4. Refer to the System Record Sheet. 
    Using the m keys, turn the associated 
    LEDs on or off, as required. Each CO 
    key/LED represents itself-that is, if 
    CO 1 LED is on, the system assumes that 
    CO 1 line is connected to a PBX line 
    and will cause features such as Toll 
    Restriction and Automatic Dialing to 
    function accordingly. An X on the record sheet means the LED 
    should be on 
    If the LED is already on, pushing 
    the associated key will turn it 
    off and vice-versa 
    LEDs may be turned off and on 
    until the desired pattern is set 
    5. Operate the ‘HOLD key to place 
    new data in memory. All Station 17 LEDs (except MW/FL) 
    go off 
    6A. Return to Step 2 in order to continue 
    with this program 
    . . . or.. . 
    6B. Go to Step 2 in another program table 
    . . . qr . . . 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/FL LED goes off 
    New data is stored, previous data is erased 
    -4%  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    TABLE 16 
    PROGRAM 1 X- PBX ACCESS CODES 
    LED on MCAU on 
    1. Operate the SET switch on the MCAU 
    2. Operate ‘3 key on Station 17 
    3. Dial 
    q q on the dial pad X = 1, 2,3, 
    4, etc.-the system will store a maximum 
    of 8 access codes. 
    Dial m m (X= 1) to program 1st access Station 17 MW/FL LED on 
    System is in program mode d 
    Normal functions halt on Station 17 
    . 
    SPKR LED steady on 
    SPKR LED flashes continuously 
    CO 10 LED will flash 
    code; 
    q q (X=2) to program the 2nd 
    access code, etc. 
    4. Refer to the System Record Sheet. 
    Using the dial pad, enter the required 
    access code (two digits must be entered) 
    l If access code is a single digit, 
    enter a 
    q as the second digit 
    l If all combinations following a 
    particular 1st digit are to be 
    considered access codes (e.g., 91, 
    92, 93, etc), operate the DND key 
    (do not care) key for the second 
    digit. 
    NOTE: INT & CO 2,4, & 6 LEDs will light to 
    display data in Binary format 
    CO 10 or 12 LED will light steadily to indicate 
    which digit is being displayed 
    Key 
    Start 1st Digit ’ 2nd Digit P co 12 Steady 
    co IO Flash Steady 
    CO8 
    CO6 Binary Data Binary Dat 
    co4 Binary Data Binary Dat 
    _ co2 Binary Data Binary Dat 
    INT Binary Data Binary Dat 
    a) Depressing the q key displays the data without changing it. The first m will display 
    the 1st digit; the second 
    q will display the 2nd digit. 
    6) To clear existing data without entering a new number, depress 
    q key two times. 
    Binary Numbers CO 6 X = LED on 
    All LEDs off = no data 
    . ..or... 
    66. Go to Step 2 in another program table 
    . ..or... 
    6C. Transfer data into working memory per LED on MCAU goes off 
    a 
    - 
    a 
    - 
    a 
    - 
    a 
    -42-  
    						
    							TABLE 17 
    PROGRAM 20-TOLL RESTRICTION DISABLE SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    . . 
    LED on MCAU on 
    1. Operate SET switch on 
    MCAU Station 17 MW/FL LED on 
    System is in program mode 
    Normal functions halt on Station 17 
    2. Operate j key on Station 17 
    SPKR LED steady on 
    3. Dial 
    q q on dial pad SPKR LED flashes continuously 
    To program CO 18 ~21, dial m 14 m, CO LEDs will be on according 
    * 
    then CO l-4 = CO 18~21. to present data 
    4. Refer to the System Record Sheet. 
    An X on the record sheet means the LED 
    Using the m keys, turn the associated LEDs 
    should be on 
    on or off, as required. Each CO key/LED 
    If the LED is already on, pushing 
    represents itself-that is, if CO 1 LED is 
    the associated key will turn it 
    on, Toll Restriction will not function on 
    off and vice-versa 
    CO 1. If CO 1 LED is off, Toll 
    LEDs may be turned off and on 
    Restriction will function on CO 1, etc. 
    until the desired pattern is set 
    5. Operate the i* key to place All Station 17 LEDs (except MW/FL) 
    new data in memory. go off 
    6A. Return to Step 2 in order to continue 
    with this program 
    . ..or... 
    6B. Go to Step 2 in another program table 
    . ..or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/F L LED goes off 
    New data is stored, previous data is erased 
    -43-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    TABLE 18 
    PROGRAM 2X-TOLL RESTRICTION EXCEPTION CODES 
    LED on MCAU on 
    1. Operate the SET switch on the MCAU Station 17 MW/F L LED on 
    System is in program mode 
    ’ 
    Normal functions halt on Station 17 
    2. Operate =I key on Station 17 SPK R LED steady on . . 
    3. Dial i?l n on the dial pad. X = 1, 2,3,4 or 5- 
    the system will store a maximum of 5 
    access codes. SPKR LED flashes continuously 
    Dial m r/ (X= 1) to program 1 st access code; CO 10 LED will flash 
    q q ( X=2) to program the 2nd access code, etc. 
    4. Refer to the System Record Sheet. INT & CO 2,4, & 6 LEDs will light to 
    Using the dial pad, enter the 4-digit display data in Binary format 
    exception code (4 digits must be entered). CO 10, 12 or 14 LEDs will light 
    l If less than 4 digits are used, steadily to indicate which digit is being 
    enter 
    for remaining digits. displayed 
    ‘VU TE: 
    j) Depressing the g key displays the data without changing it. 
    The first E will display the 1st 
    Binary Numbers X= LE.D on 
    ALL LEDs off=no data 
    . ..or... 
    6B. Go to Step 
    2 in another program table 
    . ..or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/F L LED goes off 
    New data is stored, previous data is erased 
    -44- .  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    TABLE 19 
    PROGRAM 3XX-STATION CO LINE ACCESS 
    LED on MCAU on 
    1. Operate SET switch on the MCAU Station 17 MW/FL LED on 
    System is in program mode 
    Normal functions halt on Station 17 
    2. Operate the im key on Station 17 
    3. Dial 
    q n n on the dial pad 
    XX = the station number of the station 
    to be programmed. SPKR LED steady on 
    To program CO 18~21, dial m R n r;?l, SPKR LED flashes continuously n 
    then CO l-4 = CO 18~21. CO LEDs will be on according to 
    NOTE: present data 
    For multiple station programming, refer 
    to Paragraph 02.22. 
    4. Refer to the System Record Sheet. 
    Using the CO keys, turn the associated 
    LEDs on or off, as required. 
    l LED on =Access allowed 
    l Each CO key/LED represents itself- 
    that is, if CO 1 LED is on, station 
    being programmed 
    ( q q ) is 
    allowed access to CO 1. 
    5. Operate the j/ key to place 
    new data in memory. 
    6A. Return to Step 2 in order to continue 
    with this program 
    . ..or... An X on the record sheet means 
    the LED should be on 
    If the LED is already on, pushing 
    the associated key will turn it 
    off and vice-versa 
    LEDs may be turned off and on 
    until the desired pattern is set 
    All Station 17 LEDs (except MW/FL) 
    go off 
    68. Go to Step 2 in another program table 
    . ..or... 
    6C. Transfer data into working memory 
    per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/FL LED goes off 
    New data is stored, previous data is erased 
    -45-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 TABLE 20 
    PROGRAM 4XX-STATION TYPE and KEY ASSIGNMENT 
    LED on MCAU on 
    1. Operate the SET switch on the MCAU Station 17 MW/FL LED on 
    System is in program mode 
    2. Operate the ‘F] key on Station 17 
    3. Dial m w fl on the dial pad 
    XX = the station number of the station 
    to be programmed. 
    Note: 
    For multiple station programming, refer to 
    Paragraph 02.22. 
    4. 
    Refer to the System Record Sheet. 
    Using the m or m key turn the 
    associated LED on as required, depending 
    upon the type and style of the telephone 
    being used at that station. The detailed 
    meaning of each key is shown below. 
    NOTE: Normal functions halt on Station 17 
    SPKR LED steady on 
    .’ 
    SPKR LED flashes continuously 
    An INT or CO LED will be on accord-ing to 
    present data 
    An X on the record sheet means 
    the LED should be on 
    Only one LED is permitted to be on for each 
    station. Pushing a key will turn that LED 
    on and turn off the previous LED 
    If any key/L ED is not shown, it is not used. See Par. 02.37 for the definition of the assignment numbers. 
    If a station is equipped with a DSS (Program 031, key assign. 20-key #8 will be selected automatically. 
    with this program 
    . ..or... 
    6B. Go to Step 2 in another program table 
    . . . or . . . 
    5C. Transfer data into working memory per 
    Paragraph 02.06 
    -46-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-020-300 
    JUNE 1983 
    TABLE 21 
    PROGRAM 5XX - STATION CLASS OF SERVICE 
    LED on MCAU on 
    1. Operate the SET switch on the MCAU Station 17 MW/FL LED on 
    System is in program mode 
    , 
    Normal functions halt on Station 17 
    2. Operate the I/ key on Station 17 
    3. Dial m m 
    q on the dial pad 
    XX = the station number of the station 
    to be programmed 
    NOTE: 
    For multiple station programming, refer 
    to Paragraph 02.22. 
    SPKR LED steady on .- 
    SPKR LED flashes continuously 
    INT & CO LEDs will be on according 
    to present data 
    4. Refer to the System Record Sheet. 
    Using the ) and lcoi keys, turn the 
    associated LEDs on or off, as required. 
    The detailed meaning of each key is 
    shown 
    below. 
    An X on the record sheet means 
    the LED should be on 
    If the LED is already on, pushing the 
    associated key will turn it off 
    and vice-versa 
    LEDs may be turned off and on until 
    the desired pattern is set 
    NOTE: 
    if any key/LED is not shown, it is not used. 
    5. 
    Operate the (=I key to place 
    new data in memory. 
    6A. Return to Step 2 in order to continue 
    with this program 
    . ..or... All station 17 LEDs (except MW/FL) 
    go off 
    6B. Go to Step 2 in another program table 
    . ..or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06 LED on MCAU goes off 
    Station 17 MW/FL LED goes off 
    New data is stored, previous data is erased 