Home > AEM > Analog Performance Gauges > AEM Analog Boost Metric Gauge 305137M User Manual

AEM Analog Boost Metric Gauge 305137M User Manual

Here you can view all the pages of manual AEM Analog Boost Metric Gauge 305137M User Manual. The AEM manuals for Analog Performance Gauges are available online for free. You can easily download all the documents as PDF.

Page 1

 
 
 
 
AEM Performance Electronics 2205 126th Street Unit A, Hawthorne, CA. 90250 Phone: (310) 484-2322 Fax: (310) 484-0152 http://www.aemelectronics.com Instruction Part Number: 10-5137 Rev 01  2010 AEM Performance Electronics 
 
Part Number 30-5137  
Analog Style 60 PSI Boost Pressure Gauge 
NOTE: Faceplate Configuration Instructions Included on Separate Sheet 
Figure 1.  Wiring Schematic 
AEM 60 PSI Boost Pressure Gauge Parts 
1 x 35-5137 Pressure Gauge Assembly  
1 x 30-2131-100 Pressure Sensor 
1...

Page 2

Page 2 
INSTALLATION 
 
1. Disconnect the negative battery cable. 
2. Secure the gauge in a 2 1/16th” (52MM) mounting hole with the supplied bracket. 
3. Plug the 8-wire power harness into the mating connector on the back of the 
gauge and connect the wires as shown in Figure 1.  Note: the locating tabs on 
the side of the connector should be nearest the center of the gauge. 
4. Using the supplied hose adapter, boost tee, vacuum hose, and zip ties, connect 
the sensor to a good engine manifold pressure...

Page 3

Page 3 
connected to a power ground.  Note: The BROWN wire must be connected in order 
to get correct readings from the analog output. 
 
Changing the Bezel and Faceplate 
 
The gauge kit comes with the black bezel and black faceplate installed.  However, the 
kit also comes with a silver bezel and multiple faceplates.  Instructions on how to 
change the faceplate are included in the kit on a separate sheet of paper.  To change 
the bezel, orient the gauge so you are looking at the faceplate.  Rotate the...

Page 4

Page 4 
 
 
 
Status Lights 
 
The AEM Pressure gauge has two status lights, see Figure 4.  The status light on the 
left will flash if an out of range low voltage sensor error is detected.  The status light on 
the right will flash if an out of range high voltage sensor error is detected.  In either 
case, the needle will point straight downward to signify an error.  See Table 1 for 
corrective actions. 
 
 
 
 
 
Status Light Fault Corrective Action 
Left Sensor Wiring and/or sensor Make sure sensor is...

Page 5

Page 5 
Analog Output 
 
The analog output from the AEM 100 PSI Pressure gauge is a linear dc voltage signal 
that varies from 0.5 Vdc at 0 psig (0 Bar) to 4.5 Vdc at 60 psig (4.1 Bar) over the 
operating range of the gauge.  The signal is used for sending information to a data 
logger or an engine management system like the AEM EMS or F/IC.  The transfer 
function for pressure units in PSI is listed below. 
 
Pressure (psi) = 15 x Voltage – 7.5  
 
The transfer function for pressure units in bar is...

Page 6

Page 6 
Specifications 
 
Gauge 
Supply Current 0.1 A  
Differential Analog Outputs 1 
Measuring Range 0 PSI – 60 PSI 
0 Bar - 4.1 Bar  
Operating Voltage (nominal) 8.5-15 volts dc 
Harness & Connector Temp Limit: 105C 
 
Notes 
 
The sensor is a precision pressure measuring device and should not be subject to 
mechanical or thermal shock or it may be damaged.  
 
If  further  tuning  help  is  needed  be  sure  to  visit  the  video  gallery  or  performance 
electronics  forum  at...
Start reading AEM Analog Boost Metric Gauge 305137M User Manual