    Have a look at the manual Alarm Lock DL3500 DL3500EX ETDL DL3200 Programming Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31 
    Function Number(s) Function Name Programming  
    41 Daylight Saving Time Code   
    43/44 Clock Adjust    
    52/53/54 Pass Time          (3 sec) †     10 sec †    15 sec †  
    59 AL-DTM Door Number    
    60 Set Lockout Attempts   
    61 Set Lockout Time     
    64/65 Remote Input Momentary          (Enable) †    Disable †   
    66 Ambush Code   
    67 Add Relay/System Features 
     
      
     
     
     
     
    69/70 Enter Key Enable †    (Disable) †   
      
    +/-    0-55  
     (0) (0) Seconds 
      1-96 (48 for AL-DTM (Version 1) 
    (0) (1) Door Number 
     1-9 Attempts 
    (6)  
      1-60 seconds 
    (1) (8)  
      00-99 
    (9) (9) Ambush Code 
    Default Values are shown in parentheses. 
      01-24 
    (1) (2) DST Code 
    Check all that apply   
    1.    Remote Input switch closed and Function 65 Remote 
    Input enabled † 
    2.    Remote Input switch closed and Function 64 Remote 
    Input disabled  † 
    3.    Failed attempted entry † 
    4.    Disabled User or Group † 
    5.    Follow Access Granted † 
    6.    Group 1 User Code † 
    7.    Scheduled Lock Event † 
    8.    Scheduled Unlock Event † 
    9.    Lock Out † 
    10.   Ambush † 
    11.  First Key Press † 
    25.   Disable  Sounder † 
    26.  5 sec. Delayed Entry † 
    27.  15 sec. Delayed Entry † 
    28.  45 sec. Delayed Entry † 
    29.  Toggle Passage Mode † 
    30.  Forced Unlock Follows Remote Input † 
    31.   Follow  Access  Granted--No  Time  Limit † 
    32.  Remote Input Disables Unit † 
    33.  Remote Input Puts Unit in PC Communication Mode †  
    						
    							32 
    User Number 
    (1-2000) User Code  
    (3-6 digits)  User Name 
           1 2 3 4  
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
                
    Group  
    Association 
      
    For a complete list of user codes, obtain a printout from either the remote printer 
    (Program Function 56) or using the DL-WINDOWS Software. 
    Note:  
    						
    							33 
     Day(s)  
     
       
     
     
    Function Number Up to 500 scheduled functions can be programmed (Up to 
    only 150 using AL-DTM).  For Day Enter : 
    1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday 
    5 = Thursday, 6 = Friday, 7 = Saturday, 8 = Monday through 
    Friday, 9 = Saturday and Sunday, 0 = All days of the week 
    Enter time of day in 24-hour format (00:00- 23:59)  
     
    Time  
     
    Function Name 
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :  
      :   
    						
    							34 
    ACCESS = Entry into a restricted area. 
     
    AMBUSH = A special Code entered at the keypad when the User is 
    forced to unlock a device.  The device unlocks but sends a silent 
    alarm with no indication at the keypad.  Can be used to trip a re-
    lay, to alert security, or trip a silent alarm on a Burglary Control 
    Panel. 
     
    AUDIT TR AIL = A date/time stamped log of previous lock events. 
     
    BURGLARY CONTROL PANEL = Provides local alarm and remote 
    communication to request security for burglary/break-in.  A 
    DL4500 relay output used for Ambush can provide a silent alarm 
    and call-for-help.  
     
    CLOCK 
    •REAL TIME CLOCK = An accurate built-in clock that allows date/
    time stamping of events.  The clock can be slowed or speeded up to 
    fine tune long term accuracy to within three minutes per year. 
     
    •CLOCK SETTINGS = Printout includes date, time, weekday, and 
    clock speed. 
     
    •CLOCK SPEED = The clock can be adjusted to allow faster/slower 
    speeds and therefore increasing clock accuracy. 
     
    CODE = Numeric sequence of numbers (such as: 1234) entered at 
    the keypad.  If Star-Enter-Key is required, must be followed by a 
    [:] key. 
    •AMBUSH CODE = See Ambush. 
     
    •BASIC USER CODE = User Codes assigned to User Num-
    bers 12+ (except Users 297-300).  (Does not allow 
    programming) 
     
    •INSTALLER CODE = User Codes assigned to User Numbers 
    2 and 3.  (Allows all programming except Master functions). 
     
    •INVALID CODE = A User Code that has not been 
    programmed in the lock. 
     
    •MANAGER CODE = User Codes assigned to User Numbers 4 
    through 6.  (Allows most of the programming functions). 
     
    •MASTER CODE = User Code assigned to User Number 1.  
    Default (factory) Master Code is 123456.  The User with the 
    Master Code has complete control of the lock. 
     
    •PRINT ONLY USER CODE = User Code assigned to Users 
    10 and 11.  (Allows no programming except print functions). 
     
    •QUICK ENABLE USER 300 CODE = Refers to the User Code 
    entered by User 297 which (when entered at the keypad) en-
    ables the User Code assigned to User 300 for one time only.   
     
    •QUICK PC ACCESS CODE = Permits upload/download to 
    DL-Windows Software on IBM/compatible computer running 
    Microsoft Windows 95, 98, or NT 4.0.  Refers to the User Code 
    for User 298. 
     
    •SERVICE CODE = User 300 User Code.  Allows only one 
    entry, then needs to be re-enabled by the User 297 User Code 
    to regain access. 
     
    •SUPERVISOR CODE = User Codes assigned to Users 7, 8 
    and 9.  Can only program day-to-day operation. 
     
    •USER CODE = Code used by Users.  Code is 3 to 6 numeric 
    digits long, allowing controlled entry. 
     
    •VALID CODE = An entered User Code that has been 
    programmed in the device. 
     
    COM PORT = A computer serial communications port used to 
    communicate with the Lock and/or Data Transfer Module. 
     
    DATA TRANSFER MODULE = A device that permits transfer of 
    program/data between a computer and the lock. 
     
    DATE = Month, Day and Year entered as MMDDYY. 
     
    DAY OF WEEK = Sunday through Saturday (where 1 = Sunday and 7 
    = Saturday). 
     
    DEFAULT = Default settings are the original settings that were set at 
    the factory; in other words, it is the locks original factory condition 
    when the lock was first taken out of its box.  The default settings 
    are permanently encoded within the locks fixed memory, and 
    when the lock is first started, or when power is removed and re-
    applied (see Wiring and Power-Up, page 11), the original factory 
    default settings are re-loaded and take effect. 
     
    DISABLE = Turn off. 
     
    DOOR NUMBER = Identification of each door lock with a specific 
    number in order to ensure that the correct lock is associated with 
    the correct lock program within DL-Windows or the AL-DTM.   
           Note: Door Number is a term used with AL-DTM versions 1 and 
    2 and with DL-Windows versions 3.5.0 and earlier. Later versions 
    of the AL-DTM and DL-Windows monitor door numbers automati-
    cally, therefore there is no need to manually change door numbers 
    via the keypad. Therefore, Function 59 is no longer used with the 
    later versions of the AL-DTM and DL-Windows. See page 23, 
    Function 59 for more information. 
     
    DOWNLOAD = Send data to lock or AL-DTM. 
     
    ENABLE = Turn on. 
     
    EVENTS = Recorded lock activity. 
     
    FUNCTION (also called Programming Functions) = are the numbers 
    used to program lock features (enabling/disabling Users, User 
    Groups, Passage Mode, Schedules, etc.). 
     
    GROUP 
    •USER GROUP = Defining a User to specific Groups, allows 
    User entry when the Group is allowed entry. 
     
    •GROUP 1 DISARMS BURGLAR CONTROL = A Group 1 
    USER CODE entry can disarm an alarm panel during a 
    predefined schedule.  Should the Group 1 enter the lock 
    outside of the scheduled time, the alarm will not disarm. The 
    Glossary  
    						
    							35 
    alarm panel must be armed through other means (such as an 
    Alarm Panel Keypad).  The Burglary Alarm Panel must be 
    programmed to disarm from an Armed State Only and the 
    zone input must be programmed for input disarming. 
     
    •GROUP 1 ENABLES GROUP 4 USERS = A Group 1 USER 
    CODE entry during a predefined schedule will allow access to 
    Group 4 Users. 
     
    •GROUP 1 PUTS UNIT IN PASSAGE = A Group 1 USER 
    CODE entry during a pre-defined schedule will unlock unit. 
     
    INSTALLER = See.... CODE, INSTALLER CODE. 
     
    KEYPAD = 10-numeric keys, : and special ; key. 
     
    •KEYPAD LOCKOUT = Keypad is programmed to lockout Us-
    ers, for a specified period of time, when a specified number of 
    invalid User Codes are entered. 
     
    •KEYPAD PROGRAMMING = Ability to program the lock 
    through the keypad. 
     
     
    KEYPRESS = Pressing a button on the Lock’s Keypad. 
     
    LEVEL ABILITY = Predefined User Types (such as Master, Installer, 
    Manager, Supervisor, and Print Only User) have specific abilities 
    to program and/or control the lock. 
     
    LOCKOUT ATTEMPTS = A specified number of invalid User Code 
    entries (1-9), that will disable the keypad for a predefined period of 
    time (1-60 seconds). 
     
    LOCKOUT TIME =  A predefined time (1-60) seconds that the lock will 
    stop accepting User Codes, after a specified number of invalid 
    User Code entries (1-9). 
     
    LOG = See... AUDIT TRAIL. 
     
    MANAGER = See... CODE, MANAGER CODE. 
     
    MASTER = See... CODE, MASTER CODE. 
     
    PASSAGE = Allow anyone to pass through the door without USER 
    CODES (door is unlocked). 
     
    PRINTER = A printout device such as an infrared printer or computer 
    printer. 
     
    PROGRAM MODE = A mode allowing program/data to be entered 
    through the keypad.  Only specific Users can program a lock 
    manually, by entering their USER CODE, followed by the [;] 
    key.  To exit program mode, hold any key until repeated beeps are 
    heard.  
    PROGRAMMABLE RELAY FUNCTIONS = The relay can be 
    programmed for one or more functions. 
     
    RELAY = Switched output allowing remote control of other devices.  
    For an explanation of all relay features, see Function 67 on page 
    24.   
     
    REMOTE INPUT = Entry into a restricted area, by pressing a button 
    connected to the REMOTE INPUT WIRES (White and White) by 
    someone on the other side of the door. 
     
    SCHEDULE = A programmed operation (enable/disable, lock/unlock, 
    etc.) on a specific day (Sunday through Saturday) and time. 
     
    SCHEDULES, QUICK = Any one of four most common types of 
    schedules can be programmed. 
     
    TIME = Hours and Minutes in the HHMM format. 
     
    TIME/DATE STAMP = A recorded date and time that an event 
    occurred. 
     
    TIMEOUT = Immediate operation for a specified number of hours. 
     
    UPLOAD = Receive data from the lock or AL-DTM. 
     
    USER = A person who has been provided with a USER CODE for 
    access through the door. 
     
    USER LOCKOUT, TOTAL = All Users (except for Master Code) have 
    been locked out. 
    Glossary (contd)  
    						
    							36 
    ALARM LOCK  SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in materials 
    and workmanship for 24 months following the date of manufacture. ALARM LOCK will, within said period, at its option, 
    repair or replace any product failing to operate correctly without charge to the original purchaser or user. 
    This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly 
    installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have been 
    altered, defaced or removed. Seller will not be responsible for any dismantling or reinstallation charges. 
    THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON THE 
    FACE HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF 
    FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU OF ALL OTHER 
    OBLIGATIONS OR LIABILITIES ON THE PART OF ALARM LOCK. 
    Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be brought 
    within the six months following the end of the warranty period. IN NO CASE SHALL ALARM LOCK BE LIABLE TO 
    ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER 
    WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLERS OWN 
    NEGLIGENCE OR FAULT. 
    In case of defect, contact the security professional who installed and maintains your security system. In order to exercise 
    the warranty, the product must be returned by the security professional, shipping costs prepaid and insured to ALARM 
    LOCK. After repair or replacement, ALARM LOCK assumes the cost of returning products under warranty. ALARM LOCK 
    shall have no obligation under this warranty, or otherwise, if the product has been repaired by others, improperly installed, 
    improperly used, abused, altered, damaged, subjected to accident, nuisance, flood, fire or acts of God, or on which any 
    serial numbers have been altered, defaced or removed. ALARM LOCK will not be responsible for any dismantling, 
    reassembly or reinstallation charges. 
    This warranty contains the entire warranty. It is the sole warranty and any prior agreements or representations, whether 
    oral or written, are either merged herein or are expressly canceled. ALARM LOCK neither assumes, nor authorizes any 
    other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability 
    concerning its products. 
    In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCKs original selling price of the product, 
    for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the 
    product. Sellers warranty, as hereinabove set forth, shall not be enlarged, diminished or affected by and no obligation or 
    liability shall arise or grow out of Sellers rendering of technical advice or service in connection with Buyers order of the 
    goods furnished hereunder. 
    ALARM LOCK RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY. 
    Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, electrical or 
    communications disruption, it is possible for the system to fail to perform as expected. ALARM LOCK does not represent 
    that the product/system may not be compromised or circumvented; or that the product or system will prevent any personal 
    injury or property loss by burglary, robbery, fire or otherwise; nor that the product or system will in all cases provide 
    adequate warning or protection. A properly installed and maintained alarm may only reduce risk of burglary, robbery, fire or 
    otherwise but it is not insurance or a guarantee that these events will not occur. CONSEQUENTLY, SELLER SHALL 
    HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR OTHER LOSS BASED ON A CLAIM 
    THE PRODUCT FAILED TO GIVE WARNING. Therefore, the installer should in turn advise the consumer to take any and 
    all precautions for his or her safety including, but not limited to, fleeing the premises and allege police or fire department, in 
    order to mitigate the possibilities of harm and/or damage. 
    ALARM LOCK is not an insurer of either the property or safety of the users family or employees, and limits its liability for 
    any loss or damage including incidental or consequential damages to ALARM LOCKs original selling price of the product 
    regardless of the cause of such loss or damage. 
    Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of 
    incidental or consequential damages, or differentiate in their treatment of limitations of liability for ordinary or gross 
    negligence, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights and 
    you may also have other rights which vary from state to state. 
    ALARM LOCK LIMITED WARRANTY  
    						
    All Alarm Lock manuals Comments (0)

    Related Manuals for Alarm Lock DL3500 DL3500EX ETDL DL3200 Programming Instructions User Manual