    							2-81
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Table 2-49 WS-X6724-SFP and WS-X6824-SFP-2T/-2TXL Ethernet Modules Physical and Environmental Specifications 
    Item Specification
    Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
    Weight Base module—8.8 lb (4.0 kg) 
    Base module + DFC daughter card—9.4 lb (4.3 kg)
    Power and heat numbers
    Base module + CFC daughter card (WS-F6700-CFC)
     –Module current—2.98 A
     –Module power—125.16 W
     –AC-input power—156.45 W
     –AC heat dissipation—534.28 BTU/hour
     –DC-input power—168.23 W
     –DC heat dissipation—574.49 BTU/hour
    Base module + DFC3A daughter card (WS-F6700-DFC3A)
     –Module current—5.23 A
     –Module power—219.66 W
     –AC-input power—274.58 W
     –AC heat dissipation—937.67 BTU/hour
     –DC-input power—295.24 W
     –DC heat dissipation—1008.25 BTU/hour
    Base module + DFC3B daughter card (WS-F6700-DFC3B)
     –Module current—4.93 A
     –Module power—207.06 W
     –AC-input power—258.83 W
     –AC heat dissipation—883.89 BTU/hour
     –DC-input power—278.31 W
     –DC heat dissipation—950.42 BTU/hour 
    						
    							2-82
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Power and heat numbers
    (continued)Base module + DFC3BXL daughter card (WS-F6700-DFC3BXL)
     –Module current—5.53 A
     –Module power—232.26 W
     –AC-input power—290.33 W
     –AC heat dissipation—991.46 BTU/hour
     –DC-input power—312.18 W
     –DC heat dissipation—1066.09 BTU/hour
    Base module + DFC3C daughter card (WS-F6700-DFC3C)
     –Module current—3.88 A
     –Module power—162.96 W
     –AC-input power—203.70 W
     –AC heat dissipation—695.64 BTU/hour
     –DC-input power—219.03 W
     –DC heat dissipation—748.00 BTU/hour
    Base module + DFC3CXL daughter card (WS-F6700-DFC3CXL)
     –Module current—4.58 A
     –Module power—192.36 W
     –AC-input power—240.45 W
     –AC heat dissipation—821.14 BTU/hour
     –DC-input power—258.55 W
     –DC heat dissipation—882.94 BTU/hour
    WS-X6824-SFP-2T + DFC4-A daughter card
     –Module current—4.87 A
     –Module power—204.66 W
     –AC-input power—255.68 W
     –AC heat dissipation—873.13 BTU/hour
     –DC-input power—274.92 W
     –DC heat dissipation—938.85 BTU/hour
    WS-X6824-SFP-2TXL + DFC4-AXL daughter card
     –Module current—4.99 A
     –Module power—209.66 W
     –AC-input power—261.98 W
     –AC heat dissipation— 894.64BTU/hour
     –DC-input power—281.69 W
     –DC heat dissipation—961.98 BTU/hour
    Table 2-49 WS-X6724-SFP and WS-X6824-SFP-2T/-2TXL Ethernet Modules Physical and Environmental Specifications 
    Item Specification 
    						
    							2-83
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL
    The WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Ethernet modules (Figure 2-23) provide 48 1-Gbps 
    full- or half-duplex ports. Table 2-50 lists the module features, and Table 2-50 lists the module physical 
    and environmental specifications. 
    NoteA sticker is placed on the module faceplate identifying it as either a WS-X6848-SFP-2T or 
    WS-X6848-SFP-2TXL depending on whether a WS-F6K-DFC4-A or WS-F6K-DFC4-AXL daughter 
    card is installed on the module.
    Figure 2-23 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Switching Module Front Panel
    Environment
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
    Table 2-49 WS-X6724-SFP and WS-X6824-SFP-2T/-2TXL Ethernet Modules Physical and Environmental Specifications 
    Item Specification
    Table 2-50 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Features 
    Feature Description
    Ports per module
    48 ports. Ports are numbered (left to right):
     –Top row, odd numbered ports 1–47.
     –Bottom row, even numbered ports 2–48.
    4 port groups
    Port ranges per port group:
     –1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23
     –2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24
     –25, 27, 29, 31, 33, 35, 37, 39, 41, 43, 45, 47
     –26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48
    Port connector type LC (optical) or RJ-45 (copper) depending on the type of SFP 
    transceiver installed in the port.
    STATUS
    WS-X6748-SFP
    48 PORT GIGABIT ETHERNET-SFP
    144612 
    						
    							2-84
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Cabling distance Depends on the SFP transceiver installed in the module port. For SFP 
    transceivers currently supported, refer to the compatibility matrices at 
    the following URL:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_
    device_support_tables_list.html
    For cabling distance information, refer to the transceiver installation 
    guides at the following URL:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/prod_insta
    llation_guides_list.html
    Buffer size Rx—166 kB per port
    Tx—1.17 MB per port
    Maximum frame size Up to 9216 bytes per frame
    Module oversubscription rate 1.2:1
    Supervisor engine support
    WS-X6748-SFP
     –Supervisor Engine 720
     –Supervisor Engine 720-10GE
     –Supervisor Engine 2T (the module must be equipped with 
    either a CFC daughter card, or a DFC4-A or DFC4-AXL 
    daughter card.
    WS-X6848-SFP-2T/-2TXL
     –Supervisor Engine 2T-10GE
    NoteWS-X6748-SFP modules that are upgraded with DFC4-A or 
    DFC4-AXL daughter cards are supported only on the 
    Supervisor Engine 2T-10GE
    Software support
    WS-X6748-SFP
     –With Supervisor Engine 720—12.2(17d)SXB
     –With Supervisor Engine 720 and DFC3C or 
    DFC3CXL—12.2(33)SXH
     –With Supervisor Engine 720-10GE—12.2(33)SXH
    WS-X6848-SFP-2T/-2TXL
     –With Supervisor Engine 2T-10GE—12.2(50)SY
    Queues per port
    With CFC daughter card:
     –Tx—1p3q8t
     –Rx—1q8t
    With DFC daughter card:
     –Tx—1p3q8t
     –Rx—2q8t
    Table 2-50 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Features (continued)
    Feature Description 
    						
    							2-85
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Chassis/slot restrictionsThe module is not supported in the Catalyst 6503 switch chassis. 
    The WS-X6748-SFP module can occupy any slot in any other 
    Catalyst 6500 or Catalyst 6500-E chassis with the exception of the 
    Catalyst 6513 chassis where the module must be installed only in 
    slots 9–13. The module will not power up if it is installed in 
    slots 1–8.
    The WS-X6848-SFP-2T/-2TXL operates only in a Catalyst 6500 
    E-series chassis equipped with a Supervisor Engine 2T-10GE
    Requires that modules be installed in adjacent slots or, if either 
    adjacent slot is unused, you must install a switching-module filler 
    plate (Cisco part numbers WS-X6K-SLOT-CVR-E or 
    SLOTBLANK-09) rather than a blank slot cover 
    (WS-X6K-SLOT-CVR) to maintain an adequate air flow through 
    the chassis.
    Fabric connection
    Dual switch-fabric connections:
     –Fabric channel 1—Ports 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 
    24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48
     –Fabric channel 2—Ports 1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 
    25, 27, 29, 31, 33, 35, 37, 39, 41, 43, 45, 47
    Table 2-50 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Features (continued)
    Feature Description 
    						
    							2-86
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Fabric channel speed 20 Gb/sec (dual channel, 40 Gb/sec total)
    Module upgrades available
    PoE support Not supported.
    Distributed forwarding 
    support
    The WS-X6748-SFP module ships with the WS-F6700-CFC 
    daughter card factory-installed. The module can be upgraded in the 
    field to support dCEF with the installation of a WS-F6700-DFC3A, 
    WS-F6700-DFC3B, WS-F6700-DFC3BXL, WS-F6700-DFC3C, 
    WS-F6700-DFC3CXL, WS-F6K-DFC4-A, or the 
    WS-F6K-DFC4-AXL daughter card.
    The WS-X6848-SFP-2T module ships with the DFC4-A installed; 
    the WS-X6848-TX-2TXL ships with the DFC-4AXL daughter 
    card installed.
    NoteRefer to the Catalyst 6500 Series DFC3A, DFC3B, and 
    DFC3BXL Installation Note or the Catalyst 6500 Series 
    Distributed Forwarding Card 4 for WS-X68xx Modules 
    Installation Note for additional information and field upgrade 
    procedures.
    Pluggable transceivers 
    supportSFP transceivers are supported. Refer to your software release notes to 
    determine which SFP transceivers are supported. See the “1-GB 
    Transceivers” section on page B-3 in Appendix B for additional 
    information on the SFP transceivers.
    Digital Optical Monitoring 
    (DOM) supportNot supported.
    Module front panel LEDsSTATUS
    Green—All diagnostics pass; the module is operational.
    Orange—The module is booting or running diagnostics; an 
    overtemperature condition has occurred.
    LINK
    Green—The port is active (the link is connected and operational).
    Flashing orange—The port failed diagnostics and is disabled.
    Orange—The port is disabled.
    Red—The module is resetting; an overtemperature condition has 
    occurred. 
    NoteIf the module fails to download code and configuration 
    information successfully during the initial reset, the LED stays 
    red; the module does not come online.
    Off—The port is not active or the link is not connected.
    Table 2-50 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Features (continued)
    Feature Description 
    						
    							2-87
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Table 2-51 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Physical and Environmental Specifications 
    Item Specification
    Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
    Weight
    Base module with CFC daughter card (WS-F6700-CFC) installed—9.0 lb 
    (4.1 kg)
    Base module with DFC daughter card WS-F6700-DFC installed—10.8 lb 
    (4.5 kg)
    Base module with DFC4-A or DFC4-AXL installed—10.8 lb (4.5 kg)
    Power requirement
    (at 42 VDC)
    WS-X6748-SFP + CFC daughter card WS-X6700-CFC)
     –Module current—6.07 A
     –Module power—254.94 W
     –AC-input power—318.68 W
     –AC heat dissipation—1088.28 BTU/hour
     –DC-input power—342.66 W
     –DC heat dissipation—1170.19 BTU/hour
    WS-X6748-SFP + DFC3A daughter card (WS-F6700-DFCA)
     –Module current—8.32 A
     –Module power—349.44 W
     –AC-input power—436.80 W
     –AC heat dissipation—1491.67 BTU/hour
     –DC-input power—469.68 W
     –DC heat dissipation—1603.95 BTU/hour
    WS-X6748-SFP + DFC3B daughter card (WS-F6700-DFC3B)
     –Module current—8.02 A
     –Module power—336.84 W
     –AC-input power—421.05 W
     –AC heat dissipation—1437.89 BTU/hour
     –DC-input power—452.74 W
     –DC heat dissipation—1546.11 BTU/hour 
    						
    							2-88
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Power and heat numbers
    (continued)WS-X6748-SFP + DFC3BXL daughter card (WS-F6700-DFC3BXL)
     –Module current—8.62 A
     –Module power—362.04 W
     –AC-input power—452.55 W
     –AC heat dissipation—1545.46 BTU/hour
     –DC-input power—486.61 W
     –DC heat dissipation—1661.78 BTU/hour
    WS-X6748-SFP + DFC3C daughter card (WS-F6700-DFC3C)
     –Module current—6.97 A
     –Module power—292.74 W
     –AC-input power—365.93 W
     –AC heat dissipation—1249.63 BTU/hour
     –DC-input power—393.47 W
     –DC heat dissipation—1343.69 BTU/hour
    WS-X6748-SFP + DFC3CXL daughter card (WS-F6700-DFC3CXL)
     –Module current—7.67 A
     –Module power—322.14 W
     –AC-input power—402.68 W
     –AC heat dissipation—1375.14 BTU/hour
     –DC-input power—432.98 W
     –DC heat dissipation—1478.64 BTU/hour
    WS-X6848-SFP-2T + DFC4-A daughter card
     –Module current—7.96 A
     –Module power—334.44 W
     –AC-input power—417.90 W
     –AC heat dissipation—1427.13 BTU/hour
     –DC-input power—449.35 W
     –DC heat dissipation—1534.55 BTU/hour
    WS-X6848-SFP-2TXL + DFC4-AXL daughter card
     –Module current—8.08 A
     –Module power—339.44 W
     –AC-input power—424.20 W
     –AC heat dissipation—1448.64 BTU/hour
     –DC-input power—456.13 W
     –DC heat dissipation—1557.68 BTU/hour
    Table 2-51 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Physical and Environmental Specifications (continued)
    Item Specification 
    						
    							2-89
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    WS-X6816-GBIC
    The WS-X6816-GBIC Ethernet module (Figure 2-24) provides 16 1-Gbps full- or half-duplex ports. 
    Table 2-52 lists the module features, and Table 2-53 lists the module physical and environmental 
    specifications. 
    Figure 2-24 WS-X6816-GBIC Switching Module Front Panel
    Environment
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
    Table 2-51 WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Physical and Environmental Specifications (continued)
    Item Specification
    Table 2-52 WS-X6816-GBIC Ethernet Module Features 
    Feature Description
    Ports per module
    16 ports. Ports are numbered (left to right):
     –Top row, odd numbered ports 1 through 15.
     –Bottom row, even numbered ports 2 through 16.
    2 port groups
    Port ranges per port group: 1–8, 9–16
    Port connector type SC (optical) or RJ-45 (copper) depending on the type of GBIC 
    transceiver installed in the module port.
    Cabling distance Depends on the GBIC transceiver installed in the module port. Refer to 
    Appendix B for supported GBIC transceiver types and supported 
    cabling distances.
    Buffer size
    Tx—1.17 MB per port
    Rx—166 kB per port
    QoS
    Number of egress queues: 3
    Number of ingress queues: 2
    Number of thresholds per egress queue: 2
    Number of thresholds per ingress queue: 4
    5271916 PORT GIGABIT ETHERNET
    WS-X6816-GBIC
    2S
    T
    A
    T
    U
    S
    LIN
    K LIN
    K
    1
    12
    4
    LIN
    K LIN
    K
    3
    34
    6
    L
    IN
    K LIN
    K
    5
    56
    8
    LIN
    K LIN
    K
    7
    78
    10
    LIN
    K LIN
    K
    9
    910
    12
    LIN
    K LIN
    K
    11
    11
    12
    14
    LIN
    K LIN
    K
    13
    13 14
    16
    LIN
    K L
    IN
    K
    15
    15 16 
    						
    							2-90
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      1-Gigabit Ethernet Modules
    Maximum frame size Up to 9216 bytes per frame
    Module oversubscription rate  Approximately  1:1
    Supervisor engine support Supported by the following supervisor engines:
    Supervisor Engine  2 (requires a Switch Fabric Module or SFM2 be 
    installed in the switch chassis and a DFC3 daughter card installed 
    on the WS-X6816-GBIC)
    Supervisor Engine 720 (requires a DFC3A, DFC3B, or DFC3BXL 
    daughter card be installed on the module)
    Supervisor Engine 720-10GE (requires a DFC3A, DFC3B, or 
    DFC3BXL daughter card be installed on the module)
    Software support
    With Supervisor Engine 720-10GE—12.2(33)SXH
    With Supervisor Engine 720—12.2(14)SX
    With Supervisor Engine 2—12.2(17d)SXB
    With Supervisor Engine 2—12.1(8a)E
    NoteWith CWDM GBIC and WS-G5483 GBIC 
    support—12.1(13)E. With DWDM GBIC support—12.1(20)E2
    Queues per port
    Tx—1p2q2t
    Rx—1p1q4t
    NoteRx is 2q8t when using dCEF.
    Chassis/slot restrictions
    Can occupy any slot in any Catalyst 6500 or Catalyst 6500-E 
    chassis except for the Catalyst 6513 switch chassis.
    In the Catalyst 6513 chassis, the module can occupy only slots 
    9–13. The module does not power up if it is installed in slots 1–8.
    Fabric connection
    Dual switch-fabric connections:
     –Fabric channel 1—Ports 1–8
     –Fabric channel 2—Ports 9–16
    Fabric channel speed 8 Gb/sec
    Module upgrades available
    PoE support Not supported.
    Distributed forwarding 
    supportCan be upgraded in the field to support dCEF with the installation of a 
    DFC daughter card (WS-F6K-DFC3A, WS-F6K-DFC3B, or the 
    WS-F6K-DFC3BXL).
    NoteRefer to the Catalyst 6500 Series DFC3A, DFC3B, and 
    DFC3BXL Installation Note for additional information and 
    field upgrade procedures.
    Pluggable transceivers 
    supportGBIC transceivers are supported. Refer to your software release notes 
    to determine which GBIC transceivers are supported. See the “1-GB 
    Transceivers” section on page B-3 in Appendix B for additional 
    information on the GBIC transceivers.
    Table 2-52 WS-X6816-GBIC Ethernet Module Features (continued)
    Feature Description 
    						
    All Cisco manuals Comments (0)