Home > Cisco > Ethernet Switch > Cisco 6509 E Installation Manual

Cisco 6509 E Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 6509 E Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1-45
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513 Switch
    Table 1-21 Catalyst 6513 Switch Features 
    Feature Description
    Chassis Thirteen horizontal slots. Slots are numbered from (1) top to (13) bottom. 
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CAC-2500W (2500 W AC-input power supply)
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –WS-CAC-8700W-E (8700 W AC-input power supply)
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    The 8700 W AC-input power supply is limited to 6000 W when it is 
    installed in a Catalyst 6513 switch chassis.
    Installed power supplies can be of different ratings. Installed power 
    supplies can also be both AC-input, both DC-input, or one AC-input and 
    one DC-input. Power supplies can be configured in either redundant or 
    nonredundant mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    You must install a 2500 W or higher capacity power supply when using 
    the Supervisor Engine 32 or the Supervisor Engine 720 and the 
    high-speed fan tray. 
    						
    							1-46
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513 Switch
    Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE. 
     –Supervisor Engine 2 is installed in slot 1 and slot 2. 
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine  720, and Supervisor Engine  720-10GE are installed in slot  7 
    and slot 8.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE require that you 
    install the high-speed fan tray (WS-C6K-13SLT-FAN2) be installed 
    in the chassis. You must also install a 2500 W or higher capacity 
    power supply in the chassis to power the high-speed fan tray.
     –Supervisor Engine 720 and Supervisor Engine 720-10GE have 
    built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM 
    and WS-X6500-SFM2) are not supported by Supervisor Engine  720 
    and Supervisor Engine 720-10GE and cannot be installed in the 
    same chassis.
     –Supervisor Engine 32 and Supervisor Engine 32 PISA do not 
    support the Switch Fabric Modules ((WS-C6500-SFM and 
    WS-X6500-SFM2).
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Table 1-21 Catalyst 6513 Switch Features (continued)
    Feature Description 
    						
    							1-47
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513 Switch
    ModulesChassis supports up to 12 Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 7 or slot 8.
    WS-X6748-SFP, WS-X6748-GE-TX, and WS-X6704-10GE modules 
    are not supported in slots 2–8; they are supported in slots 9–13.
     –Slots 1–8 support a single fabric channel; slots 9–13 support dual 
    fabric channels.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a Supervisor Engine 720
     –Have chassis slot restrictions
     –Require a specific software release level
    NoteCheck your software release notes for specific information on 
    module support and restrictions.
    Table 1-21 Catalyst 6513 Switch Features (continued)
    Feature Description 
    						
    							1-48
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513 Switch
    Table 1-22 Catalyst 6513 Switch Specifications 
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storage–4° to 149°F (–20° to 65°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 10% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating  Certified for operation: 0 to 6500 feet (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
    Physical Characteristics
    Dimensions (H x W x D)33.3 x 17.2 x 18.1 in. (84.6 x 43.7 x 46.0 cm). 
    Chassis requires 20 RU.
    Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D 
    and ETS 300-119 standards.
    Weight Chassis fully configured with 2 supervisor engines, 11 switching modules, 
    and 2 power supplies: 280 lb (127 kg).
    Airflow
    WS-C6K-13SLOT-FAN (standard fan tray)—641 CFM
    WS-C6K-13SLT-FAN2 (optional high-speed fan tray)—1090 CFM 
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15  cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side.  
    						
    							1-49
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513-E Switch
    Catalyst 6513-E Switch
    The Catalyst 6513-E switch is an enhanced version of the Catalyst 6513 chassis. Figure 1-15 shows a 
    front view of the chassis. Table 1-23 provides a description of the major switch features. Table 1-24 lists 
    the specifications of the Catalyst 6513-E switch chassis. 
    Figure 1-15 Catalyst 6513-E Switch
    INPUT
    OKFA N
    OKOUTPUT
    FAIL
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I L
    o
    208620
    Power supply 1Power supply 2
    (redundant)
    8 PORT GIGABIT ETHERNETWS-X64081LINKSTATUS2
    3
    45
    6
    7
    8LINKLINKLINKLINKLINKLINKLINK
    24 PORT 100FXWS-X6224STATUS
    24 PORT 100FXWS-X6224STATUS
    24 PORT 100FXWS-X6224STATUS
    24 PORT 100FXWS-X6224STATUS
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    WS-SUP32-GE-3BS TAT U S
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVISOR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINKWS-SUP32-GE-3BSTATUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVISOR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    W S-C 6513-E
    Switching modules
    Switching modules
    Fan assembly
    (accessible from
    rear of chassis) Supervisor engine
    Redundant supervisor
    engine 
    						
    							1-50
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513-E Switch
    Table 1-23 Catalyst 6513-E Switch Features 
    Feature Description
    Chassis Thirteen horizontal slots. Slots are numbered from (1) top to (13) bottom. 
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –PWR-6000-DC (6000 W DC-input power supply)
     –WS-CAC-8700W-E (8700 W AC-input power supply)
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    Installed power supplies can be of different ratings. Installed power 
    supplies can also be both AC-input, both DC-input, or one AC-input and 
    one DC-input. Power supplies can be configured in either redundant or 
    nonredundant mode.
    Supervisor Engine 2T requires a 3000 W or greater power supply to 
    operate.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated. 
    						
    							1-51
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513-E Switch
    Supervisor enginesSupports Supervisor Engine 32, Supervisor Engine 720, Supervisor 
    Engine 720-10GE, and Supervisor Engine 2T. 
     –Supervisor Engine 32, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE are installed in slot 7 and slot 8.
     –Supervisor Engine 720, Supervisor Engine 720-10GE, and 
    Supervisor Engine 2T have built-in switching fabric; Switch Fabric 
    Modules (WS-C6500-SFM and WS-X6500-SFM2) are not 
    supported.
     –Supervisor Engine 32 does not support the Switch Fabric Modules 
    ((WS-C6500-SFM and WS-X6500-SFM2).
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Table 1-23 Catalyst 6513-E Switch Features (continued)
    Feature Description 
    						
    							1-52
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513-E Switch
    ModulesChassis supports up to 12 Catalyst 6500 series modules.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a specific supervisor engine
     –Have chassis slot restrictions
     –Require a specific software release level
    NoteCheck your software release notes for specific information on 
    module support and restrictions.
    Table 1-24 Catalyst 6513-E Switch Specifications 
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storage–4° to 149°F (–20° to 65°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 10% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating  Certified for operation: 0 to 6500 feet (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
    Table 1-23 Catalyst 6513-E Switch Features (continued)
    Feature Description 
    						
    							1-53
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513-E Switch
    Physical Characteristics
    Dimensions (H x W x D)33.3 x 17.2 x 18.1 in. (84.6 x 43.7 x 46.0 cm). 
    Chassis requires 20 RU.
    Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D 
    and ETS 300-119 standards.
    Weight Chassis fully configured with 2 supervisor engines, 11 switching modules, 
    and 2 power supplies: 280 lb (127 kg).
    Airflow
    WS-C6513-E-FAN—1755 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15  cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side. 
    Table 1-24 Catalyst 6513-E Switch Specifications (continued)
    Item Specification 
    						
    							1-54
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6513-E Switch 
    						
    All Cisco manuals Comments (0)

    Related Manuals for Cisco 6509 E Installation Manual