    Installing Options201
    Removing a memory module
    c
    Caution:
    Before you remove a memory module, be sure to discharge any static electricity by touching a grounded 
    piece of metal. Otherwise, you may damage static-sensitive components.
    w
    Warning:
    Be careful when working inside the printer as some components are sharp and may cause injury.
    Perform the installation procedure in reverse.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products202
    Chapter 10 
    Replacing Consumable Products
    Replacement Messages
    If a consumable product reaches the end of its service life, the printer stops printing and displays 
    the following messages on the LCD panel or the window of EPSON Status Monitor. When this 
    happens, replace the depleted consumable products.
    * The letters C, M, Y, or K appear in this position, indicating the color of the imaging cartridge to be replaced. For 
    example, the message Yellow Toner Low means that the yellow imaging cartridge is near the end of its service life.
    Note:
    Messages appear for one consumable product at a time. After replacing a consumable product, check the LCD 
    panel for replacement messages for other consumable products.
    Imaging Cartridge
    Handling precautions
    Always observe the following handling precautions when replacing the consumable products:
    ❏Installing a genuine imaging cartridge is recommended. Using a non-genuine imaging 
    cartridge may affect print quality. Epson shall not be liable for any damages or problems 
    arising from the use of consumable products not manufactured or approved by Epson.
    ❏When handling imaging cartridge, always place them on a clean smooth surface.
    ❏If you have moved an imaging cartridge from a cool to a warm environment, wait for at least 
    one hour before installing it to prevent damage from condensation.
    LCD Panel Message Description
    Replace Toner uuuu* The imaging cartridge for the indicated color has reached the end of its 
    service life.
    Replace Fuser The fuser unit has reached the end of its service life.
    Replace Transfer Unit The transfer unit has reached the end of its service life.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products203
    ❏Do not expose the imaging cartridge to sunlight at all and avoid exposing it to room light for 
    more than five minutes. Exposure to light can damage the drum, causing dark or light areas to 
    appear on the printed page and reducing the service life of the drum.
    w
    Warning:
    ❏Do not touch the toner. Keep the toner away from your eyes. If toner gets on your skin or 
    clothes, wash it off with soap and water immediately.
    ❏Keep consumable products out of the reach of children.
    ❏Do not dispose of used consumable products in fire, as they may explode and cause injury. 
    Dispose of them according to local regulations.
    ❏If toner is spilled, use a broom and dustpan or a damp cloth with soap and water to clean it up. 
    Because the fine particles can cause a fire or explosion if they come into contact with a spark, 
    do not use a vacuum cleaner.
    Replacing an imaging cartridge
    Follow the steps below to replace an imaging cartridge.
    1. Confirm the color of the imaging cartridge that needs to be replaced by checking the LCD panel 
    or EPSON Status Monitor.
    2. Press the latch on the front cover and open the cover.
    c
    Caution:
    ❏Do not leave the front cover open for more than five minutes to avoid exposing the imaging 
    cartridges to light.
    ❏Do not expose the imaging cartridges to sunlight at all.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products204
    3. Remove the used imaging cartridge from the printer.
    w
    Warning:
    Be careful not to touch the fuser, which is marked CAUTION HIGH TEMPERATURE, or the 
    surrounding areas. If the printer has been in use, the fuser and the surrounding areas may be very 
    hot. If you must touch one of these areas, wait 30 minutes to allow the heat to subside before doing 
    so.
    c
    Caution:
    Do not touch the transfer belt on the transfer unit to avoid damaging it.
    4. Take the new imaging cartridge out of its package, and gently shake it from side to side and 
    front to back to distribute the toner evenly.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products205
    5. Remove the cartridge seal, pulling straight from the imaging cartridge. Make sure to pull the 
    tape slowly to avoid tearing it.
    6. Insert the new imaging cartridge all the way until it stops.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products206
    7. Remove the orange plastic cover by pinching the center of the cover and pulling it.
    8. Close the front cover.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products207
    Fuser Unit
    Handling precautions
    Always observe the following handling precautions when replacing the consumable products.
    Do not touch the surface of the consumable product. Doing so may impair print quality.
    w
    Warning:
    ❏The fuser unit can be very hot if the printer has been in use. Turn the printer off and wait for 30 
    minutes until the temperature has subsided before replacing the fuser unit.
    ❏Keep the consumable products out of the reach of children.
    Replacing the fuser unit
    Follow the steps below to replace the fuser unit.
    1. Turn off the printer, and wait with the front cover closed for 30 minutes until the temperature 
    has subsided.
    *OFF
    *
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products208
    2. Press the latch on the front cover and open the cover.
    c
    Caution:
    ❏Do not leave the front cover open for more than five minutes to avoid exposing the imaging 
    cartridges to light.
    ❏Do not expose the imaging cartridges to sunlight at all.
    3. Take the light shielding paper from the new fuser unit’s package and attach it to the printer.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products209
    4. Open the paper guide on the top front of the printer.
    5. Unlock the lock levers on both sides of the fuser unit.
    6. Pull the fuser unit towards you and then lift it out of the printer.
     
    						
    							AcuLaser C2800 Series Users Guide
    Replacing Consumable Products210
    w
    Warning:
    Be careful not to touch the fuser, which is marked CAUTION HIGH TEMPERATURE, or the 
    surrounding areas. If the printer has been in use, the fuser and the surrounding areas may be very 
    hot. If you must touch one of these areas, wait 30 minutes to allow the heat to subside before doing 
    so.
    7. Take the new fuser unit out of its package and remove the protective materials.
    8. Lower the new fuser into the printer making sure that the notch on the right side of the fuser 
    unit into the post of the printer.
     
    						
    All Epson manuals Comments (1)

    Related Manuals for Epson AcuLaser C2800N User Manual