Home > GE > Alarm system > GE Cpv14di018 Manual

GE Cpv14di018 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Cpv14di018 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							2004/11 – Subject to change – Info 20111
    Fieldbus Direct, CPV-DI01
    Technical data – Fieldbus node CPV-DI01
    Connection and display components
    1
    2
    4 3
    1Red LED: Bus status/error (BUS)
    2Green LED: Power supply
    (POWER)
    3Yellow LED row: For pilot solenoid
    coils 12
    4Yellow LED row: For pilot solenoid
    coils 14
    Pin allocation for fieldbus interface (plug view)
    PinFesto Sub- DManufacturer-specific signal designation
    plug (IP65)Festo fieldbusABB CS31PROFIBUS DPMoeller SUCONET K
    interface
    3
    Sub- D, 9- pinDIN (round)
    5- pin
    1n.c.
    2n.c.
    3BS+Bus1RxD/TxD-P3(TA/RA)4(TA/RA)
    4CNTR-P
    5DGND
    6VP
    7n.c.
    8AS-Bus2RxD/TxD-N7(TB/RB)1(TB/RB)
    9n.c.
    HousingCable clipScreenScreenScreen4 (screen)Housing
    Pin allocation for M12 adapter
    Profibus DP
    (signal)Bus In (pin)Bus Out (socket)Designation
    ScreenM12 and 5M12 and 5Screen or functional earthing
    RxD / TxD-P44Data B
    DGND-3Reference potential to supply
    voltage plus (VP)
    VP (P5V)-1Supply voltage – Plus
    RxD / TxD-N22Data A 
    						
    							Info 201 – Subject to change – 2004/1112
    Fieldbus Direct, CPV-DI01
    Accessories – Fieldbus node CPV-DI01
    Ordering data
    DesignationTy p ePart No.
    Power supply
    Power supply socket, straightFBSD-GD-718 497
    FBSD-GD-918 495
    Power supply socket, angledFBSD-WD-718 524
    FBSD-WD-918 525
    Fieldbus connection
    Fieldbus socket, Sub- D connectionFBS-Sub-9-GS-DP-B532 216
    M12 adapterFBA-2-M12-5POL-RK533 118
    Valve terminal connection
    Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g
    1mKVI-CP-1-WS-WD-1.0191 892
    2mKVI-CP-1-WS-WD-2163 139
    3mKVI-CP-1-WS-WD-3.0191 893
    5mKVI-CP-1-WS-WD-5163 138
    Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137
    8mKVI-CP-1-GS-WD-8163 136
    Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g
    5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235
    8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616
    User documentation
    UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-DI01-DE165 816,
    DI01EnglishP.BE-CP-DI01-EN165 817
    ItalianP.BE-CP-DI01-IT165 818
    FrenchP.BE-CP-DI01-FR165 819
    SpanishP.BE-CP-DI01-ES165 820
    SwedishP.BE-CP-DI01-SV165 821
    Software
    CD-ROMValve terminal user
    documentation (PDF)P.CD-VALVE-T183 350
    UtilitiesP.CD-VI-UTILITIES-2533 500 
    						
    							2004/11 – Subject to change – Info 20113
    Fieldbus Direct, CPV-DN2
    Technical data – Fieldbus node CPV-DN2
    CPV fieldbus node for communication
    between a CPV valve terminal and a
    fieldbusmaster.Thefieldbusnodeis
    used for activation of a CPV valve
    terminal with 8 valve slices and
    16 solenoid coils and for displaying
    the switching status via LED.
    TheCPV-…valvesareactivatedusing
    automatic current reduction, which
    resultsinlesspowerconsumption
    and heat emission. 16 digital inputs
    and 8 digital outputs or 16 solenoid
    coils can be connected via a serial CP
    string extension.
    The CPV fieldbus node supports the
    DeviceNet protocol and conforms to
    the equipment profile of the
    pneumatic valve.
    TheCPVfieldbusnodeisavailablein
    three sizes, with identical
    performance characteristics:
    CPV10
    CPV14
    CPV18
    Application
    Bus connection
    Micro Style Open Style
    Open Style
    5- pin terminal strip
    For installations in protected
    environments (IP20)
    Open Style offers a 5-pin row with the
    DeviceNet pin allocation.
    If the valve terminal is ordered with
    this bus connection, the 5-pin screw
    terminal strip will also be supplied. It
    is designed with double screw
    terminals for the incoming and the
    outgoing bus cable. This connection
    technology provides the function of a
    T-distributor.Micro Style
    Push-in connector 2xM12
    Installation with IP65 protection
    Micro Style is prepared for connecting
    through the bus cable with an M12
    plug for the incoming cable and a
    socket for the outgoing bus cable.
    The bus connection fulfils the require-
    ment of a T-distributor, this means
    that the CPV valve terminal can be
    disconnected from the DeviceNet with-
    out interrupting the bus. This method
    of direct connection does away with
    the need for the branch line length in
    the DeviceNet configuration. 
    						
    							Info 201 – Subject to change – 2004/1114
    Fieldbus Direct, CPV-DN2
    Technical data – Fieldbus node CPV-DN2
    Condition monitoring
    Condition monitoring supports the
    preventative maintenance of the func-
    tionchaininautomationsystems.
    Each valve is assigned a switching
    cycle counter that automaticallyregisters movements of the system
    components.
    Once a maximum number of
    activations is reached, a message issent to the controller via DeviceNet
    and maintenance can be started. In
    the same way condition monitoring
    supports the determination of theservice intervals for the function
    chain.
    All movements immediately after
    installation are registered.
    General technical data
    Ty p eCPV10-GE-DN2-8CPV14-GE-DN2-8CPV18-GE-DN2-8
    Part No.525 630525 878525 880
    CP string extensionYes
    16 inputs and 8 outputs (or 16 valves)
    Baud rates[kbps]125, 250, 500
    Addressing range0…63
    Set using switch module
    Product familyPneumatic valve (27 dec.)
    Ident. number8942 dec.
    Type of communicationPolling, change of state, strobed I/O
    Configuration supportEDS file and graphics symbol
    Max. no. of solenoid coils2x16
    Max. no. of outputs8 (1x16 solenoid coils omitted)
    Max. no. of inputs16
    LED diagnostic displaysPSCommon message concerning supply voltagegpy
    MNSDeviceNet status
    Device-specific diagnosis via DeviceNetShort circuit/overload of outputs
    Short circuit/overload of inputs
    Undervoltage of valve terminal
    Undervoltage of valve terminal (extension)
    Undervoltage of output module
    Undervoltage of sensor supply
    Missing module on CP string
    Condition monitoring
    Operating voltageNominal value[V]24 DC, reverse polarity protectedpgg
    Permissible range[V]20.4 … 26.4 DC
    Power failure buffering[ms]20
    Current consumption[mA]Max. 200 + sensor supply
    Protection class to EN 60 529IP65
    ApprovalCE
    Temperature rangeOperating[°C]–5 … +50pg
    Storage[°C]–20 … +60
    MaterialsHousingDie-cast aluminium
    Plug capPolyamide, glass fibre (Ultramide)
    SealNitrile rubber, Neoprene
    DimensionsInfo 213 Valve terminal CPV
    WeightInfo 213
    Technical data for valvesInfo 213 
    						
    							2004/11 – Subject to change – Info 20115
    Fieldbus Direct, CPV-DN2
    Technical data – Fieldbus node CPV-DN2
    Connection and display components
    1
    5 2
    3
    4
    61Interchangeable fieldbus
    connection:
    – Micro Style connection
    (2xM12)
    – Open Style connection
    (terminal strip)
    –9-pinSub-Dplug
    2Switch module (removable)
    3Connection for voltage supply
    (4-pin M12 plug, operating
    voltage for electronics, load
    voltage for CP valves)
    4LEDs:
    –Powerstatus(PS)
    – Module/network status (MNS)
    5CP extension connection
    6Switching status displays of CPV
    solenoid coils
    Pin allocation for M12 adapter
    PinSignal-specific
    core colourSignalDesignation
    1blankScreenConnection to housing
    2red24 V DC bus24 V supply CAN interface
    3black0Vbus0VCANinterface
    4whiteCAN_HReceived/transmitted data high
    5blueCAN_LReceived/transmitted data low
    Pin allocation for Open Style adapter
    PinSignal-specific
    core colourSignalDesignation
    1black0Vbus0VCANinterface
    2blueCAN_LReceived/transmitted data low
    3blankScreenConnection to housing
    4whiteCAN_HReceived/transmitted data high
    5red24 V DC bus24 V DC supply CAN interface 
    						
    							Info 201 – Subject to change – 2004/1116
    Fieldbus Direct, CPV-DN2
    Accessories – Fieldbus node CPV-DN2
    Ordering data
    DesignationTy p ePart No.
    Power supply
    Power supply socket, straightFBSD-GD-718 497
    FBSD-GD-918 495
    Power supply socket, angledFBSD-WD-718 524
    FBSD-WD-918 525
    Bus connection Micro Style M12
    Bus connection Micro Style, 2xM12FBA-2-M12-5POL525 632
    Fieldbus socket for Micro Style connection, M12, 5-pin, straightFBSD-GD-9-5POL18 324
    Plug for Micro Style connection, M12, 5-pin, straightFBS-M12-5GS-PG9175 380
    Bus connection Open Style, 5-pin screw terminal strip
    Bus connection Open Style for 5-pin terminal stripFBA-1-SL-5POL525 634
    Bus connection, 5-pin terminal stripFBSD-KL-2x5POL525 635
    Valve terminal connection
    Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g
    1mKVI-CP-1-WS-WD-1.0191 892
    2mKVI-CP-1-WS-WD-2163 139
    3mKVI-CP-1-WS-WD-3.0191 893
    5mKVI-CP-1-WS-WD-5163 138
    Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137
    8mKVI-CP-1-GS-WD-8163 136
    Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g
    5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235
    8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616
    User documentation
    UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-DN2-DE526 016,
    DN2EnglishP. B E - C P - D N 2 - E N526 017
    ItalianP. B E - C P - D N 2 - I T526 018
    FrenchP. B E - C P - D N 2 - F R526 019
    SpanishP. B E - C P - D N 2 - E S526 020
    SwedishP. B E - C P - D N 2 - S V526 021
    Software
    CD-ROMValve terminal user
    documentation (PDF)P.CD-VALVE-T183 350
    UtilitiesP.CD-VI-UTILITIES-2533 500 
    						
    							2004/11 – Subject to change – Info 20117
    Fieldbus Direct, CPASC1-AE32-DN
    Technical data – Fieldbus node CPASC1-AE32-DN
    CPASC1 fieldbus node for communica-
    tion between a CPASC1 valve terminal
    and a fieldbus master. The fieldbus
    node is used for activation of a
    CPASC1 valve terminal with up to
    32 solenoid coils on max. 24 valve
    positions and for displaying the
    switching status via LED.
    TheCPASC1…valvesareactivated
    using automatic current reduction,
    which results in less power consump-
    tion and heat emission. 16 digital
    inputs and 8 digital outputs or
    16 solenoid coils can be connected
    via a serial CP string extension.
    TheCPASC1fieldbusnodesupports
    the DeviceNet protocol and conforms
    to the equipment profile of the
    pneumatic valve.
    Application
    Bus connection
    The DeviceNet connection is estab-
    lished via a 5-pin M12 plug with pins
    that corresponds to the specific mini
    connector. A DeviceNet installation
    with a higher degree of protection is
    typically configured using main and
    branch lines that are connected via
    T- pieces.Various manufacturers such as Turck,
    Lumberg and Rockwell offer finished
    cables and terminating resistors. The
    terminating resistors are attached to
    the two outermost T-pieces. This
    installation technique keeps the bus
    closed while a bus station is being
    removed.In order to prevent confusion when
    establishing a connection to the field-
    bus, a Micro Style M12, 5-pin plug
    connector with a straight socket
    (A-coded) is used. A Micro Style M12,
    5- pin plug connector with a straight
    socket (B- coded) is used for the power
    supply. 
    						
    							Info 201 – Subject to change – 2004/1118
    Fieldbus Direct, CPASC1-AE32-DN
    Technical data – Fieldbus node CPASC1-AE32-DN
    Condition monitoring
    Condition monitoring supports the
    preventative maintenance of the func-
    tionchaininautomationsystems.
    Each valve is assigned a switching
    cycle counter that automaticallyregisters movements of the system
    components.
    Once a maximum number of
    activations is reached, a message issent to the controller via DeviceNet
    and maintenance can be started. In
    the same way condition monitoring
    supports the determination of theservice intervals for the function
    chain.
    All movements immediately after
    installation are registered.
    General technical data
    Ty p eCPASC1 -AE3 2 -DN
    Part No.538 652
    CP string extensionYes
    16 inputs and 8 outputs (or 16 valves)
    Baud rates[kbps]125, 250, 500
    Addressing range0…63
    Set using switch module
    Product familyPneumatic valve (27 dec.)
    Ident. number5250 dec.
    Type of communicationPolling, change of state, strobed I/O
    Configuration supportEDS file and graphics symbol
    Max. no. of solenoid coils32+16
    Max. no. of outputs8 (1x16 solenoid coils omitted)
    Max. no. of inputs16
    LED diagnostic displaysPSCommon message concerning supply voltagegpy
    PLPower supply for valves
    SFCP system error
    NETDeviceNet network status
    MODDeviceNet module status
    Device-specific diagnosis via DeviceNetShort circuit/overload of outputs
    Short circuit/overload of inputs
    Undervoltage of valve terminal
    Undervoltage of valve terminal (extension)
    Undervoltage of output module
    Undervoltage of sensor supply
    Missing module on CP string
    Condition monitoring
    Operating voltageNominal value[V]24 DC, reverse polarity protectedpgg
    Permissible range[V]20.4 … 26.4 DC
    Power failure buffering[ms]20
    Current consumption[mA]Max. 200 + sensor supply
    Residual ripple[Vss]4
    Protection class to EN 60 529IP40 (with fitted cover)
    Vibration resistanceTo EN 60 068-2-6: Wall mounting class 2
    H-rail mounting class 1
    Shock resistanceTo EN 60 068-2-27: Wall mounting class 2
    H-rail mounting class 1
    To EN 60 068-2-29: Wall mounting class 1
    H-rail mounting class 1
    ApprovalCE
    Temperature rangeOperating[°C]–5 … +50pg
    Storage[°C]–20 … +50
    MaterialsPolymer
    DimensionsInfo 211
    WeightInfo 211
    Technical data for valvesInfo 211 
    						
    							2004/11 – Subject to change – Info 20119
    Fieldbus Direct, CPASC1-AE32-DN
    Technical data – Fieldbus node CPASC1-AE32-DN
    Connection and display components
    654732181Connection for CP extension
    2Connection for power supply
    3Connection for fieldbus
    4DIL switch for CP extension
    5Rotary switch for baud rate
    6Rotary switch for station number
    7Earth terminal
    8Cover (for IP40 protection)
    Pin allocation for fieldbus interface
    PinSignal-specific
    core colourSignalDesignation
    1blankScreenConnection to housing
    2red24 V DC bus24 V supply CAN interface
    3black0Vbus0VCANinterface
    4whiteCAN_HReceived/transmitted data high
    5blueCAN_LReceived/transmitted data low 
    						
    							Info 201 – Subject to change – 2004/1120
    Fieldbus Direct, CPASC1-AE32-DN
    Accessories – Fieldbus node CPASC1-AE32-DN
    Ordering data
    DesignationTy p ePart No.
    Power supply Micro Style M12
    Power supply socket, for Micro Style connection, M12, 5-pin, straight socket (B-coded)NTSD-GD-9-M12-5POL-RK538 999
    Bus connection Micro Style M12
    Fieldbus socket for Micro Style connection, M12, 5- pin, straight socket (A- coded)FBSD-GD-9-5POL18 324
    Valve terminal connection
    Connecting cable with angled plug and angled socket0.5 mKVI-CP-1-WS-WD-0,5178 564ggpgg
    1mKVI-CP-1-WS-WD-1.0191 892
    2mKVI-CP-1-WS-WD-2163 139
    3mKVI-CP-1-WS-WD-3.0191 893
    5mKVI-CP-1-WS-WD-5163 138
    Connecting cable with straight plug and angled socket5mKVI-CP-1-GS-WD-5163 137
    8mKVI-CP-1-GS-WD-8163 136
    Connecting cable with straight plug and straight socket2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234ggpgg
    5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235
    8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616
    User documentation
    UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CPASC-CPVSC-DE539 008,
    DN2EnglishP.BE-CPASC-CPVSC-EN539 009
    ItalianP.BE-CPASC-CPVSC-IT539 010
    FrenchP.BE-CPASC-CPVSC-FR539 011
    SpanishP.BE-CPASC-CPVSC-ES539 012
    SwedishP.BE-CPASC-CPVSC-SV539 013
    Software
    CD-ROMValve terminal user
    documentation (PDF)P.CD-VALVE-T183 350
    UtilitiesP.CD-VI-UTILITIES-2533 500 
    						
    All GE manuals Comments (0)