LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 802D/SV(Cube) (F-32120, SRT, Stroke Volume) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (G-0373, SRT, Image Mode) = (G-03A2, SRT, 2D mode) or (R-409E2, SRT, Doppler Color Flow) depending on scan mode (G-C036, SRT, Measurement Method) = (125206, DCM, Cube Method) 2D/SI(Cube) (F-00078, SRT, Stroke Index) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (G-0373, SRT, Image Mode) =...
Page 92
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 812D/LVs Mass/ASE (18087-7, LN, Left Ventricle Mass) (G-0373, SRT, Image Mode) = (G-03A2, SRT, 2D mode) or (R-409E2, SRT, Doppler Color Flow) depending on scan mode (R-4089A, SRT, Cardiac Cycle Point) = (F- 32020, SRT, Systole) (G-C036, SRT, Measurement Method) = (125221, DCM, Left Ventricle Mass by M- mode) 2D/LVA diastole (G-0375, SRT, Left Ventricular Diastolic Area) (G-0373, SRT, Image Mode) = (G-03A2, SRT,...
Page 93
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 822D/EF(A-L) (18043-0, LN, Left Ventricular Ejection Fraction) (G-0373, SRT, Image Mode) = (G-03A2, SRT, 2D mode) or (R-409E2, SRT, Doppler Color Flow) depending on scan mode (G-C036, SRT, Measurement Method) = (125205, DCM, Area-Length Single Plane) 2D/SV(A-L) (F-32120, SRT, Stroke Volume) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (G-0373, SRT, Image Mode) = (G-03A2, SRT, 2D mode) or...
Page 94
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 83LVESV(A-L A4C) (18148-7, LN, Left Ventricular End Systolic Volume) (111031, DCM, Image View) = (G-A19C, SRT, Apical four chamber) (G-C036, SRT, Measurement Method) = (125205, DCM, Area-Length Single Plane) LVESV(MOD A4C) (18148-7, LN, Left Ventricular End Systolic Volume) (111031, DCM, Image View) = (G-A19C, SRT, Apical four chamber) (G-C036, SRT, Measurement Method) = (125208, DCM, Method of Disks, Single...
Page 95
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 84CO(MOD A4C) (F-32100, SRT, Cardiac Output) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (111031, DCM, Image View) = (G-A19C, SRT, Apical four chamber) (G-C036, SRT, Measurement Method) = (125208, DCM, Method of Disks, Single Plane) CI(MOD A4C) (F-32110, SRT, Cardiac Index) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (111031, DCM, Image View) = (G-A19C, SRT, Apical four chamber)...
Page 96
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 85CO(A-L A2C) (F-32100, SRT, Cardiac Output) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (111031, DCM, Image View) = (G-A19B, SRT, Apical two chamber) (G-C036, SRT, Measurement Method) = (125205, DCM, Area-Length Single Plane) CI(A-L A2C) (F-32110, SRT, Cardiac Index) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (111031, DCM, Image View) = (G-A19B, SRT, Apical two chamber)...
Page 97
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 86LVAs(LAX) (G-0374, SRT, Left Ventricular Systolic Area) (111031, DCM, Image View) = (G-0395, SRT, Apical long axis) LVESV(A-L LAX) (18148-7, LN, Left Ventricular End Systolic Volume) (111031, DCM, Image View) = (G-0395, SRT, Apical long axis) (G-C036, SRT, Measurement Method) = (125205, DCM, Area-Length Single Plane) LVESV(MOD LAX) (18148-7, LN, Left Ventricular End Systolic Volume) (111031, DCM, Image View) =...
Page 98
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 87SI(MOD LAX) (F-00078, SRT, Stroke Index) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (111031, DCM, Image View) = (G-0395, SRT, Apical long axis) (G-C036, SRT, Measurement Method) = (125208, DCM, Method of Disks, Single Plane) CO(MOD LAX) (F-32100, SRT, Cardiac Output) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (111031, DCM, Image View) = (G-0395, SRT, Apical long axis)...
Page 99
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 88LVAs(sax PM) (G-0374, SRT, Left Ventricular Systolic Area) (111031, DCM, Image View) = (G-039B, SRT, Parasternal short axis at the Papillary Muscle level) LVAd(sax) (G-0375, SRT, Left Ventricular Diastolic Area) (111031, DCM, Image View) = (G-0397, SRT, Parasternal short axis) LVAs(sax) (G-0374, SRT, Left Ventricular Systolic Area) (111031, DCM, Image View) = (G-0397, SRT, Parasternal short axis) EDV(mod sim)...
Page 100
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 89ESV(bp el) (18148-7, LN, Left Ventricular End Systolic Volume) (G-C036, SRT, Measurement Method) = (125211, DCM, Biplane Ellipse) EF(bp el) (18043-0, LN, Left Ventricular Ejection Fraction) (G-C036, SRT, Measurement Method) = (125211, DCM, Biplane Ellipse) SV(bp el) (F-32120, SRT, Stroke Volume) (G-C0E3, SRT, Finding Site) = (T-32600, SRT, Left Ventricle) (G-C036, SRT, Measurement Method) = (125211, DCM,...