GE Logiq 7 User Manual
Here you can view all the pages of manual GE Logiq 7 User Manual. The GE manuals for Medical Equipment are available online for free. You can easily download all the documents as PDF.
Page 71
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 60>Study Instance UID (0020,000D) 1 Taken from Study Instance UID in General Study Module >Referenced Study Sequence (0008,1110) 2 Not used >>Referenced SOP Class UID (0008,1150) 1 Not used >>Referenced SOP Instance UID (0008,1155) 1 Not used >Accession Number (0008,0050) 2 Taken from Accession Number in General Study Module >Placer Order Number/Imaging Service Request (0040,2016) 2 Not used >Filler Order...
Page 72
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 61Content Template Sequence (0040,A504) 1C - Template id GEMS_US_0100 from mapping resource 99GEMS - Template id 5100 Vascular Ultrasound Procedure Report from resource DCMR -Template id 5000 OBGYN Ultrasound Procedure Report from resource DCMR -Template id 5200 Adult Echocardiography Procedure Report from resource DCMR > Template Identification Macro Value Type (0040,A040) 1 CONTAINER Continuity of Content...
Page 73
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 62Comprehensive SR 5000 “OB-GYN Ultrasound Procedure Report” Create Comprehensive SR 5100 “Vascular Ultrasound Procedure Report” Create Comprehensive SR 5200 “Adult Echocardiography Procedure Report” Create
Page 74
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 637.6 STANDARD EXTENDED AND PRIVATE DATA ATTRIBUTES Not applicable. 7.7 STANDARD EXTENDED AND PRIVATE CONTEXT GROUPS Not applicable. 7.8 STANDARD EXTENDED AND PRIVATE TEMPLATES LOGIQ 7 supports the Standard Extended and Private Templates defined in the following sections. 7.8.1 Standard Extended Templates i. Usage and Extension of TID 5100 Vascular Ultrasound Report NL Relation with Parent Value Type...
Page 75
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 64 NL Relation with Parent Value Type Concept Name VM Req Type Condition Value Set Constraint 1 CONTAINER DT (121111, DCM, “Summary”) 1 M > CONTAINS TEXT EV (121106, DCM, “Comment”) 1 M iv. TID 5103 Vascular Ultrasound Section NL Relation with Parent Value Type Concept Name VM Req Type Condition Value Set Constraint 1 CONTAINER DT (121070, DCM, “Findings”) 1 M > HAS CONCEPT MOD CODE EV (G-C0E3,...
Page 76
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 65(T-40501, SRT, “Blood Vessel of Head”) (G-A101, SRT, Left) for Left, (G-A100, SRT, Right) for Right. Or (G-A103, SRT, Unilateral) DCID 12105 or (12106) Intracranial Cerebral Vessels (Unilateral) Anatomy GEU parameter (G-C0E3, SRT, Finding Site) ICA (T-45300, SRT, Internal Carotid Artery) MCA G (T-45600, SRT, Middle Cerebral Artery) ACA (T-45540, SRT, Anterior Cerebral Artery) PCA (T-45900, SRT,...
Page 77
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 66(T-49403, SRT, “Vein of Lower Extremity”) (G-A101, SRT, Left) for Left, or (G-A100, SRT, Right) for Right. DCID (12110) Lower Extremity of Veins Anatomy GEU parameter (G-C0E3, SRT, Finding Site) Popliteal (T-49640, SRT, Popliteal Vein) LSaphenous (T-49550, SRT, Lesser Saphenous Vein) AntTibial (T-49630, SRT, Anterior Tibial Vein) PostTibial (T-49620, SRT, Posterior Tibial Vein) Peroneal (T-49650, SRT,...
Page 78
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 67(T-71019, SRT, “Vascular Structure of Kidney”) (G-A101, SRT, Left) for Left, or (G-A100, SRT, Right) for Right. DCID(12115) Renal Vessels Anatomy GEU parameter (G-C0E3, SRT, Finding Site) MRenalA (T-46600, SRT, Renal Artery) RenalV (T-48740, SRT, Renal Vein) SegmentalA (T-46659, SRT, Segmental Artery) InterlobarA (T-4667D, SRT, Interlobar Artery of Kidney) ArcurateA (T-4668A, SRT, Arcuate Artery of the...
Page 79
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 68ICA/CCA Ratio (PS) (33868-1, LN, ICA/CCA velocity”) with Concept Modifier (R-4089A, SRT, Cardiac Cycle Point) = (F-32030, SRT, Systole) ICA/CCA Ratio (ED) (33868-1, LN, ICA/CCA velocity”) with Concept Modifier (R-4089A, SRT, Cardiac Cycle Point) = (F-32010, SRT, Diastole) Note: If there are multiple measurements, the measurement, which noted for further processing has possible derivation and selection, which...
Page 80
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 69 ix. TID 5001 OB-GYN Patient Characteristics NL Relation with Parent Value Type Concept Name VM Req Type Condition / Notes 1 CONTAINER EV (12118, DCM, “Patient Characteristics”) M > CONTAINS TEXT EV (121106, DCM,”Comment”) 1 U > CONTAINS NUM EV (8302-2, LN, “Patient Height”) 1 U > CONTAINS NUM EV (11996-6, LN, “Gravida) 1 U See GEU SR Mapping Table > CONTAINS NUM EV (11977-6, LN,”Para”) 1 U See GEU...