    							9 COMPONENT IDENTIFICATION
    PARALLEL OPERATION OUTLETS
    OVERLOAD INDICATOR LIGHT
    OUTPUT INDICATOR LIGHT
    FUEL TANK CAP VENT LEVER
    FUEL TANK CAP AC RECEPTACLES
    GROUND TERMINALDC CIRCUIT PROTECTORDC RECEPTACLE
    MAINTENANCE COVERAC CIRCUIT PROTECTOR
    CHOKE LEVER
    ENGINE SWITCH OIL ALERT
    INDICATOR LIGHT
    STARTER GRIP ECO-THROTTLE SWITCH
    TM
    06/12/21 09:12:43 31Z07602_010 
    						
    							10
    SPARK PLUG MAINTENANCE COVER
    SPARK PLUG
    MUFFLER
    AIR CLEANERFRAME SERIAL NUMBER
    Record the frame serial number for your future reference. Refer to this
    serial number when ordering parts, and when making technical or
    warranty inquiries (see page ).
    Frame serial number:
    Date purchased:62
    06/12/21 09:12:49 31Z07602_011 
    						
    							11 CONTROLS
    ENGINE SWITCH
    STARTER GRIP Switch position:
    OFF:
    ON:
    OOFFFF
    OONN ENGINE SWITCH
    STARTER GRIP
    DDiirreeccttiioonnttooppuullll
    To start and stop the engine.
    To stop the engine.
    To start and run the engine.
    Do not allow the starter grip to snap back against the engine. Return it
    gently to prevent damage to the starter.
    To start the engine, pull the starter grip lightly until you feel resistance,
    then pull briskly in the direction of the arrow as shown below.
    06/12/21 09:12:58 31Z07602_012 
    						
    							12
    FUEL TANK CAP VENT LEVER
    CHOKE LEVER
    CHOKE LEVER
    OOPPEENN
    OONNOOFFFF
    FUEL TANK CAP VENT LEVER
    CLOSEDFUEL TANK CAP VENT LEVEROONNOOFFFF NON-CALIFORNIA TYPE CALIFORNIA TYPE
    The fuel tank cap is provided with a vent lever to seal the fuel tank.
    The vent lever must be in the ON position for the engine to run.
    The choke is used to provide proper starting mixture when the engine
    is cold. It can be opened and closed by operating the choke lever
    manually. Move the choke lever to the CLOSED position to enrich the
    mixture for cold starting. When the engine is not in use, leave the vent lever in the OFF position
    to reduce the possibility of fuel leakage. Allow the engine to cool well
    before turning the vent lever to the OFF position.
    06/12/21 09:13:08 31Z07602_013 
    						
    							13
    OUTPUT INDICATOR LIGHT
    OVERLOAD INDICATOR LIGHT
    OVERLOAD INDICATOR
    LIGHT (RED)OUTPUT INDICATOR
    LIGHT (GREEN)
    The output indicator light (green) is illuminated when the generator is
    operating normally. It indicates that the generator is producing
    electrical power at the receptacles.
    If the generator is overloaded (in excess of 2,000 VA), or if there is a
    short circuit in a connected appliance, the overload indicator light (red)
    will go ON. The overload indicator light (red) will stay ON, and after
    about four seconds, current to the connected appliance(s) will shut off,
    and the output indicator light (green) will go OFF.
    ——y
    y
    /y
    y 
    						
    							14
    OIL ALERTSYSTEM
    GROUND TERMINAL
    GROUND TERMINALOIL ALERT INDICATOR
    LIGHT (RED)
    The generator ground terminal is connected to the frame of the
    generator, the metal non-current-carrying parts of the generator, and
    the ground terminals of each receptacle.
    Before using the ground terminal, consult a qualified electrician,
    electrical inspector or local agency having jurisdiction for local codes
    or ordinances that apply to the intended use of the generator. If the engine stops or the Oil Alert indicator light comes on when you
    pull the starter grip, check the engine oil level (see page ) before
    troubleshooting in other areas. The Oil Alert
    system is designed to prevent engine damage caused
    by an insufficient amount of oil in the crankcase. Before the oil level in
    the crankcase can fall below a safe limit, the Oil Alert indicator light
    comes on and the Oil Alert system automatically will stop the engine
    (the engine switch will remain in the ON position).
    28
    06/12/21 09:13:17 31Z07602_015 
    						
    							15
    PARALLEL OPERATION OUTLETS ECO-THROTTLE SWITCH
    ON:
    OFF:
    TM
    OOFFFF
    PARALLEL OPERATION OUTLETS
    OONN ECO-THROTTLE SWITCH
    The Eco-Throttle system automatically reduces engine speed when
    all loads are turned off or disconnected. When appliances are turned
    on or reconnected, the engine returns to the proper speed to power
    the electrical load.
    If high electrical loads are connected simultaneously, turn the Eco-
    Throttle switch to the OFF position to reduce voltage changes.
    When using the DC output, turn the Eco-Throttle switch to the OFF
    position.
    Recommended to minimize fuel consumption and further
    reduce noise levels when no load is applied to the generator.
    The Eco-Throttle system does not operate.
    These outlets are used for connecting two EU2000i generators for
    parallel operation (see page ). A Honda approved parallel operation
    kit (optional equipment) is required for parallel operation. This kit can
    be purchased from an authorized Honda generator dealer.23TM
    06/12/21 09:13:27 31Z07602_016 
    						
    							16
    AC CIRCUIT PROTECTOR
    DC RECEPTACLE
    DC CIRCUIT PROTECTOR
    PUSH AC CIRCUIT PROTECTOR AC RECEPTACLES
    AC CIRCUIT PROTECTORON
    OFF
    ONOFF
    DC CIRCUIT PROTECTORDC RECEPTACLE
    PUSH
    The AC circuit protector will automatically switch OFF if there is a short
    circuit or a significant overload of the generator at the AC receptacles.
    If the circuit protector switches OFF automatically, check that the
    appliance is working properly and does not exceed the rated load
    capacity of the circuit before resetting the circuit protector ON.
    The DC circuit protector automatically shuts off the DC battery
    charging circuit when the DC charging circuit is overloaded, when
    there is a problem with the battery, or when the connections between
    the battery and the generator are improper. The DC receptacle should ONLY be used for charging 12-volt
    automotive type batteries. The DC charging output is not regulated.
    06/12/21 09:17:33 31Z07602_017 
    						
    							17 GENERATOR USE
    CONNECTIONS TO A BUILDING ELECTRICAL SYSTEM
    Improper connections to a building electrical system can allow
    electrical current from the generator to backfeed into the utility lines.
    Such backfeed may electrocute utility company workers or others
    who contact the lines during a power outage, and the generator may
    explode, burn, or cause fires when utility power is restored. Consult
    the utility company or a qualified electrician.
    GROUND SYSTEM Connections for standby power to a building electrical system must be
    made by a qualified electrician. The connection must isolate the
    generator power from utility power, and must comply with all
    applicable laws and electrical codes.
    Honda portable generators have a system ground that connects
    generator frame components to the ground terminals in the AC output
    receptacles. The system ground is not connected to the AC neutral
    wire. If the generator is tested by a receptacle tester, it will not show
    the same ground circuit condition as for a home receptacle.
    05/12/26 17:07:15 31Z07602_018 
    						
    							18
    SPECIAL REQUIREMENTS
    Do not lay the generator on its side when moving, storing, or
    operating it. Oil may leak and damage the engine or your property.
    There may be Federal or State Occupational Safety and Health
    Administration (OSHA) regulations, local codes, or ordinances that
    apply to the intended use of the generator. Please consult a qualified
    electrician, electrical inspector, or the local agency having jurisdiction.
    In some areas, generators are required to be registered with local
    utility companies.
    If the generator is used at a construction site, there may be
    additional regulations that must be observed.
    Keep all cooling holes open and clear of debris, mud, water, etc.
    Cooling holes are located on the side panel, the control panel, and the
    bottom of the generator. If the cooling holes are blocked, the
    generator may overheat and damage the engine, inverter, or windings.
    06/12/21 09:17:38 31Z07602_019 
    						