    							6 - 31
    128 Redundancy bar code below, then scan a redundancy count between 
    0 and 10 on the Programming Chart inside the back cover of this manual.  
    Then scan the Save bar code.  Default = 0.
    GS1-128 Message Length
    Scan the bar codes below to change the message length.  Refer to 
    Message Length Description (page 6-2) for additional information.  Mini-
    mum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum 
    Default = 80.
    GS1-128 Redundancy
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 32
    Te l e p e n
    
    Telepen On/Off
    Telepen Output
    Using AIM Telepen Output, the scanner reads symbols with start/stop pat-
    tern 1 and decodes them as standard full ASCII (start/stop pattern 1).  
    When Original Telepen Output is selected, the scanner reads symbols with 
    start/stop pattern 1 and decodes them as compressed numeric with 
    optional full ASCII (start/stop pattern 2).  Default = AIM Telepen Output.
    Telepen Redundancy
    If you are encountering errors when reading Telepen bar codes, you may 
    want to adjust the redundancy count.  Redundancy adjusts the number of 
    times a bar code is decoded before transmission, which may reduce the 
    number of errors.  Note that the higher the redundancy count, the longer it 
    will take to decode the bar code.  To adjust the redundancy, scan the 
    On
    *  Off
    Original Telepen Output *  AIM Telepen Output 
    						
    							6 - 33
    Telepen Redundancy bar code below, then scan a redundancy count 
    between 0 and 10 on the Programming Chart inside the back cover of this 
    manual.  Then scan the Save bar code.  Default = 0.
    Telepen Message Length
    Scan the bar codes below to change the message length.  Refer to 
    Message Length Description (page 6-2) for additional information.  Mini-
    mum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum 
    Default = 80.
    UPC-A
    
    UPC-A On/Off
    Note: To convert UPC-A bar codes to EAN-13, see Convert UPC-A to 
    EAN-13 on page 6-44.
    Telepen Redundancy
    Minimum Message Length
    Maximum Message Length
    *  On
    Off 
    						
    							6 - 34
    UPC-A Number System and Check Digit
    UPC-A Number System
    The numeric system digit of a U.P.C. symbol is normally transmitted at 
    the beginning of the scanned data, but the  can be programmed so it 
    will not transmit it.   Default = On.
    UPC-A Check Digit
    This selection allows you to specify whether the check digit should be 
    transmitted at the end of the scanned data or not.  Default = On.
    Check 
    Digit Number
    System
    UPC-A sample showing the number system and check digit:
    Off *  On
    *  On
    Off 
    						
    							6 - 35
    UPC-A Addenda
    This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
    Default = Off for both 2 Digit and 5 Digit Addenda.
    UPC-A Addenda Required
    When Required is scanned, the scanner will only read UPC-A bar codes 
    that have addenda.  You must then turn on  a 2 or 5 digit addenda listed on 
    page 6-35.  Default = Not Required.
    Addenda Timeout
    You can set a time during which the scanner looks for an addenda.  If an 
    addenda is not found within this time period, the data can be either trans-
    mitted or discarded, based on the setting you are using for UPC-A 
    Addenda Required (see page 6-35).  Set the length (in milliseconds) for this 
    * 5 Digit Addenda Off 5 Digit Addenda On* 2 Digit Addenda Off 2 Digit Addenda On
    *  Not Required Required 
    						
    							6 - 36
    timeout by scanning the bar code below, then setting the timeout (from 0-
    65535 milliseconds) by scanning digits from the Programming Chart, then 
    scanning Save.  Default = 100.
    Note: The Addenda Timeout setting is applied to all addenda and coupon 
    code searches.
    UPC-A Addenda Separator  
    When this feature is on, there is a space between the data from the bar 
    code and the data from the addenda.  When turned off, there is no space.  
    Default = Off.
    UPC-A Redundancy
    If you are encountering errors when reading UPC-A bar codes, you may 
    want to adjust the redundancy count.  Redundancy adjusts the number of 
    times a bar code is decoded before transmission, which may reduce the 
    number of errors.  Note that the higher the redundancy count, the longer it 
    will take to decode the bar code.  To adjust the redundancy, scan the UPC-
    A Redundancy bar code below, then scan a redundancy count between 0 
    and 10 on the Programming Chart inside the back cover of this manual.  
    Then scan the Save bar code.  Default = 0.
    UPC-A/EAN-13 with Extended Coupon Code
    Use the following codes to enable or disable UPC-A and EAN-13 with Extended 
    Coupon Code.  When left on the default setting (Off), the scanner treats Cou-
    pon Codes and Extended Coupon Codes as single bar codes.  
    Addenda Timeout
    * Off On
    UPC-A Redundancy 
    						
    							6 - 37
    If you scan the Allow Concatenation code, when the scanner sees the coupon 
    code and the extended coupon code in a single scan, it transmits both as sepa-
    rate symbologies.  Otherwise, it transmits the first coupon code it reads.  
    If you scan the Require Concatenation code, the scanner must see and read 
    the coupon code and extended coupon code in a single read to transmit the 
    data.  No data is output unless both codes are read. 
    Default = Off.
    UPC-A Number System 4 Addenda Required 
    This setting programs the scanner to require a coupon code only on UPC-A 
    bar codes that begin with a “4.”  The following settings can be programmed:
    Require Coupon Code:  All UPC-A bar codes that begin with a “4” must 
    have a coupon code.  The UPC-A bar code with the coupon code is then 
    transmitted as a single, concatenated bar code.  If a coupon code is not 
    found within the Addenda Timeout period, the UPC-A bar code is dis-
    carded.
    Don’t Require Coupon Code:  If you have selected Require Coupon 
    Code, and you want to disable this feature, scan Don’t Require Coupon 
    Code.  UPC-A bar codes are transmitted, depending on the setting you are 
    using for UPC-A/EAN-13 with Extended Coupon Code.
    Default = Don’t Require Coupon Code.
    Allow Concatenation * Off
    Require Concatenation
    Require Coupon Code * Don’t Require Coupon Code 
    						
    							6 - 38
    UPC-A Number System 5 Addenda Required 
    This setting programs the scanner to require any combination of a coupon 
    code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that 
    begin with a “5.”  The following settings can be programmed:
    Require Coupon Code/Addenda:  All UPC-A bar codes that begin with a 
    “5” must have a coupon code, a 2 digit addenda, a 5 digit addenda, or a 
    combination of these addenda.  The UPC-A bar code with the coupon code 
    and/or addenda is then transmitted as a single, concatenated bar code.  If 
    a coupon code and/or required addenda is not found within the Addenda 
    Timeout period, the UPC-A bar code is discarded.
    Don’t Require Coupon Code/Addenda:  If you have selected Require 
    Coupon Code/Addenda, and you want to disable this feature, scan Don’t 
    Require Coupon Code/Addenda.  UPC-A bar codes are transmitted, 
    depending on the setting you are using for UPC-A/EAN-13 with Extended 
    Coupon Code.
    Default = Don’t Require Coupon Code/Addenda.
    Require 2 Digit Addenda * Don’t Require Coupon Code/
    Addenda
    Require 5 Digit Addenda
    Require 2 or 5 Digit Addenda
    Require Coupon Code
    Require Coupon Code or 2 Digit 
    Addenda
    Require Coupon Code or 5 Digit 
    Addenda
    Require Coupon Code, 2 Digit 
    Addenda, or 5 Digit Addenda 
    						
    							6 - 39
    Addenda Timeout
    You can set a time during which the scanner looks for a coupon code.  If a 
    coupon code is not found within this time period, the data can be either 
    transmitted or discarded, based on the setting you are using for UPC-A/
    EAN-13 with Extended Coupon Code or UPC-A Number System 4 
    Addenda Required.  Set the length (in milliseconds) for this timeout by 
    scanning the bar code below, then setting the timeout (from 0-65535 milli-
    seconds) by scanning digits from the Programming Chart, then scanning 
    Save.  Default = 100.
    Note: The Addenda Timeout setting is applied to all addenda and coupon 
    code searches.
    UPC-E0
    
    UPC-E0 On/Off
    Most U.P.C. bar codes lead with the 0 number system.  To read these 
    codes, use the UPC-E0 On selection.  If you need to read codes that lead 
    with the 1 number system, use EAN/JAN-13 (page 6-44).  Default = On.
    Addenda Timeout
    *  UPC-E0 On
    UPC-E0 Off 
    						
    							6 - 40
    UPC-E0 Expand
    UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.  
    Default = Off.
    UPC-E0 Number System
    The numeric system digit of a UPC-A symbol is normally transmitted at the 
    beginning of scanned data.  When using UPC-E Expand, the unit can be 
    programmed so it will not transmit it.  Default = On.
    On
    *  Off
    Off *  On 
    						