    							9 - 27
    Codabar Check 
    Char.*No Check Char. CBRCK206-4
    Validate Modulo 16, 
    But Don’t TransmitCBRCK216-4
    Validate Modulo 16, 
    and TransmitCBRCK226-4
    Validate Modulo 7 
    CD, But Don’t 
    Tr a n s m i tCBRCK236-4
    Validate Modulo 7 
    CD, and TransmitCBRCK246-4
    Validate CLSI, But 
    Don’t TransmitCBRCK256-4
    Validate CLSI, and 
    Tr a n s m i tCBRCK266-4
    Codabar 
    Concatenation*Off CBRCCT06-5
    On CBRCCT16-5
    Require CBRCCT26-5
    Concatenation 
    TimeoutDLYCCT6-5
    Codabar 
    RedundancyRange (0 - 10) *0 CBRVOT##6-5
    Codabar Message 
    LengthMinimum (1 - 80)  *3 CBRMIN##6-6
    Maximum (1 - 80)  
    *80CBRMAX##6-6
    Code 39 Default All Code 39 
    SettingsC39DFT6-7
    Off C39ENA06-7
    *On C39ENA16-7
    Code 39 Start/Stop 
    Char.*Don’t Transmit C39SSX06-7
    Transmit C39SSX16-7 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 28
    Code 39 Check Char.*No Check Char. C39CK206-8
    Validate, But Don’t 
    Tr a n s m i tC39CK216-8
    Validate, 
    and TransmitC39CK226-8
    Code 39 
    RedundancyRange (0 - 10) *0 C39VOT##6-8
    Code 39 Message 
    LengthMinimum (1 - 80)  *3 C39MIN##6-8
    Maximum (1 - 80)  
    *80C39MAX##6-8
    Code 32 
    Pharmaceutical 
    (PARAF)*Off C39B3206-9
    On C39B3216-9
    Code 39 Full ASCII *Off C39ASC06-10
    On C39ASC16-10
    Interleaved 2 of 5 Default All 
    Interleaved
    2 of 5 SettingsI25DFT6-10
    Off I25ENA06-10
    *On I25ENA16-10
    NULL Characters *Off I25NUL06-10
    On I25NUL16-10
    Interleaved 2 of 5 
    Check Digit*No Check Char. I25CK206-11
    Validate, But Don’t 
    Tr a n s m i tI25CK216-11
    Validate, and 
    Tr a n s m i tI25CK226-11
    Interleaved 2 of 5 
    RedundancyRange (0 - 10) *0 I25VOT##6-11
    Interleaved 2 of 5 
    Message LengthMinimum (1 - 80)  *6 I25MIN##6-12
    Maximum (1 - 80)  
    *80I25MAX##6-12 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 29
    NEC 2 of 5 Default All NEC
    2 of 5 SettingsN25DFT6-12
    *Off N25ENA06-12
    On N25ENA16-12
    NEC 2 of 5 Check 
    Digit*No Check Char. N25CK206-13
    Validate, But Don’t 
    Tr a n s m i tN25CK216-13
    Validate, and 
    Tr a n s m i tN25CK226-13
    NEC 2 of 5 
    RedundancyRange (0 - 10) *0 N25VOT##6-13
    NEC 2 of 5 Message 
    LengthMinimum (1 - 80)  *3 N25MIN##6-13
    Maximum (1 - 80)  
    *80N25MAX##6-13
    Code 93 Default All Code 93 
    SettingsC93DFT6-14
    Off C93ENA06-14
    *On C93ENA16-15
    Code 93 
    RedundancyRange (0 - 10) *0 C93VOT##6-14
    Code 93 Message 
    LengthMinimum (1 - 80)  *3 C93MIN##6-15
    Maximum (1 - 80)  
    *80C93MAX##6-15
    Straight 2 of 5 
    IndustrialDefault All Straight 2 
    of 5 Industrial 
    SettingsR25DFT6-15
    *Off R25ENA06-15
    On R25ENA16-15
    Straight 2 of 5 
    Industrial 
    RedundancyRange (0 - 10) *0 R25VOT##6-16
    Straight 2 of 5 
    Industrial Message 
    LengthMinimum (1 - 80)  *3 R25MIN##6-16
    Maximum (1 - 80)  
    *80R25MAX##6-16 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 30
    Straight  2 of 5 IATA Default All Straight 2 
    of 5 IATA
    SettingsA25DFT6-17
    Straight  2 of 5 IATA *Off A25ENA06-17
    On A25ENA16-17
    Straight  2 of 5 IATA 
    RedundancyRange (0 - 10) *0 A25VOT##6-17
    Straight  2 of 5 IATA 
    Message LengthMinimum (1 - 80)  
    *13A25MIN##6-18
    Maximum (1 - 80)  
    *15A25MAX##6-18
    Matrix 2 of 5 Default All Matrix 2 
    of 5
    SettingsX25DFT6-18
    *Off X25ENA06-18
    On X25ENA16-18
    Matrix 2 of 5 
    RedundancyRange (0 - 10) *0 X25VOT##6-19
    Matrix 2 of 5 
    Message LengthMinimum (1 - 80)  *3 X25MIN##6-19
    Maximum (1 - 80)  
    *80X25MAX##6-19
    Matrix 2 of 5 Check 
    Char.*No Check Char. X25CK206-19
    Validate, But Don’t 
    Tr a n s m i tX25CK216-19
    Validate and 
    Tr a n s m i tX25CK226-19
    Code 11 Default All Code 11 
    SettingsC11DFT6-20
    *Off C11ENA06-20
    On C11ENA16-20 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 31
    Code 11 Check 
    Digits Required1 Check Digit 
    RequiredC11CK206-20
    *2 Check Digits 
    RequiredC11CK216-20
    Auto Select Check 
    Digits RequiredC11CK226-20
    Check Digit 
    ValidationValidate and 
    Transmit One Check 
    DigitC11CK236-21
    Validate and 
    Tr a n s m i t  Tw o  C h e c k  
    DigitsC11CK246-21
    Validate and 
    Tr a n s m i t  A u t o  S e l e c t  
    Check DigitsC11CK256-21
    Code 11 
    RedundancyRange (0 - 10) *0 C11VOT##6-21
    Code 11 Message 
    LengthMinimum (1 - 80)  *3 C11MIN##6-22
    Maximum (1 - 80)  
    *80C11MAX##6-22
    Code 128 Default All Code 128
    Settings128DFT6-23
    Off 128ENA06-23
    *On 128ENA16-23
    128 Group Separator 
    Output*Off 128GSE06-23
    On 128GSE16-23
    Code 128 
    RedundancyRange (0 - 10) *0 128VOT##6-24
    Code 128 Message 
    LengthMinimum (1 - 80)  *1 128MIN##6-24
    Maximum (1 - 80)  
    *80128MAX##6-24
    ISBT 128 *Off ISBENA06-24
    On ISBENA16-24
    Concatenation 
    TimeoutDLYCCT6-25 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 32
    ISBT128 Predefined 
    Concatenation 
    Sequences* Donation ID 
    Number (001)
    and ABO/RhD Blood 
    Groups (002)ISBPCS06-25
    Donation ID Number 
    (001) and
    Donor ID Number 
    (019)ISBPCS16-25
    Donation ID Number 
    (001) and 
    Confidential Unit 
    Exclusion StatusISBPCS26-25
    Product Code (003) 
    and Expiration Date 
    (Form 1)ISBPCS36-25
    Product Code (003) 
    and Expiration Date 
    (Form 2)ISBPCS46-25
    Product Code (003) 
    and Expiration Date 
    (Form 3)ISBPCS56-25
    Product Code (003) 
    and Expiration Date 
    (Form 4)ISBPCS66-25
    ISBT 128 Predefined 
    Concatenation 
    Sequences On/Off*Off ISBPCE06-26
    Allow Predefined 
    SequenceISBPCE16-26
    Require Predefined 
    SequenceISBPCE26-26 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 33
    ISBT 128 User-
    Defined 
    Concatenation 
    Sequences1st Left Identifier (0-
    255) *0ISBUL1##6-27
    2nd Left Identifier (0-
    255) *0ISBUL2##6-27
    1st Right Identifier 
    (0-255) *0ISBUR1##6-27
    2nd Right Identifier 
    (0-255) *0ISBUR2##6-27
    ISBT 128 User-
    Defined 
    Concatenation 
    Sequences On/Off*Off ISBUCE06-28
    Allow User-Defined 
    SequenceISBUCE16-28
    Require User-
    Defined SequenceISBUCE26-28
    Content Verification *Off ISBXM006-28
    On ISBXM016-28
    Transmit Identifiers Off ISBXM106-29
    *On ISBXM116-29
    Flag Conversion *Off ISBXM206-29
    On ISBXM216-29
    GS1-128 Default All GS1-128 
    SettingsGS1DFT6-30
    *On GS1ENA16-30
    Off GS1ENA06-30
    GS1-128 Application 
    Identifier Parsing*Off GS1EMU06-30
    Transmit Without 
    IdentifiersGS1EMU16-30
    Tr a n s m i t  W i t h  
    IdentifiersGS1EMU26-30
    GS1-128 
    RedundancyRange (0 - 10) *0 GS1VOT##6-31
    GS1-128 Message 
    LengthMinimum (1 - 80)  *3 GS1MIN6-31
    Maximum (0 - 80)  
    *80GS1MAX6-31 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 34
    Telepen Default All Telepen
    SettingsTELDFT6-32
    *Off TELENA06-32
    On TELENA16-32
    Telepen Output *AIM Telepen Output TELOLD06-32
    Original Telepen 
    OutputTELOLD16-32
    Telepen Redundancy Range (0 - 10) *0 TELVOT##6-33
    Telepen Message 
    LengthMinimum (1 - 80)  *3 TELMIN##6-33
    Maximum (1 - 80)  
    *80TELMAX##6-33
    UPC-A Default All 
    UPC-A SettingsUPADFT6-33
    Off UPBENA06-34
    *On UPBENA16-34
    UPC-A Number 
    SystemOff UPANSX06-34
    *On UPANSX16-34
    UPC-A Check Digit Off UPACKX06-33
    *On UPACKX16-34
    UPC-A 2 Digit 
    Addenda*Off UPAAD206-35
    On UPAAD216-35
    UPC-A 5 Digit 
    Addenda*Off UPAAD506-35
    On UPAAD516-35
    UPC-A Addenda 
    Required*Not Required UPAARQ06-35
    Required UPAARQ16-35
    Addenda Timeout Range (0 - 65535) 
    *100DLYADD#####6-36
    UPC-A Addenda 
    Separator*Off UPAADS06-36
    On UPAADS16-36
    UPC-A Redundancy Range (0 - 10) *0 UPAVOT##6-36 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 35
    UPC-A/EAN-13 with 
    Extended Coupon 
    Code*Off CPNENA06-37
    Allow Concatenation CPNENA16-37
    Require 
    ConcatenationCPNENA26-37
    UPC-A Number 
    System 4 Addenda 
    Required* Don’t Require 
    Coupon CodeARQSY406-37
    Require Coupon 
    CodeARQSY416-37
    UPC-A Number 
    System 5 Addenda 
    Required* Don’t Require 
    Coupon Code/
    AddendaARQSY506-38
    Require 2 Digit 
    AddendaARQSY516-38
    Require 5 Digit 
    AddendaARQSY526-38
    Require 2 or 5 Digit 
    AddendaARQSY536-38
    Require Coupon 
    CodeARQSY546-38
    Require Coupon 
    Code or 2 Digit 
    AddendaARQSY556-38
    Require Coupon 
    Code or 5 Digit 
    AddendaARQSY566-38
    Require Coupon 
    Code, 2 Digit 
    Addenda, or 5 Digit 
    AddendaARQSY576-38
    Addenda Timeout Range (0 - 65535) 
    *100DLYADD#####6-39
    UPC-E0 Default All UPC-E
    SettingsUPEDFT6-39
    Off UPEEN006-39
    *On UPEEN016-39 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 36
    UPC-E0 Expand *Off UPEEXP06-40
    On UPEEXP16-40
    UPC-E0 Number 
    System*On UPEEXN16-40
    Off UPEEXN06-40
    UPC-E0 Check Digit *Off UPECKX06-41
    On UPECKX16-41
    UPC-E0 Leading 
    Zero*Off UPENSX06-41
    On UPENSX16-41
    UPC-E0 Addenda 2 Digit Addenda On UPEAD216-42
    *2 Digit Addenda Off UPEAD206-42
    5 Digit Addenda On UPEAD516-42
    *5 Digit Addenda Off UPEAD506-42
    UPC-E0 Addenda 
    RequiredRequired UPEARQ16-42
    *Not Required UPEARQ06-42
    Addenda Timeout Range (0 - 65535) 
    *100DLYADD#####6-43
    UPC-E0 Addenda 
    SeparatorOn UPEADS16-43
    *Off UPEADS06-43
    UPC-E0 
    RedundancyRange (0 - 10) *1 UPEVOT##6-43
    EAN/JAN-13 Default All EAN/
    JAN SettingsE13DFT6-44
    Off E13ENA06-44
    *On E13ENA16-44
    Convert UPC-A to 
    EAN-13UPC-A Converted to 
    EAN-13UPAENA06-44
    *Do Not Convert 
    UPC-AUPAENA16-44
    EAN/JAN-13 Check 
    DigitOff E13CKX06-45
    *On E13CKX16-45 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						