Home > Honeywell > Scanner > Honeywell 1300g2 Owners Manual

Honeywell 1300g2 Owners Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1300g2 Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							6 - 45
    Code 49
    
    Code 49
    Code 49 Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.    Minimum and Maximum
    lengths = 1-81.   Minimum Default = 1, Maximum Default = 81.
    On
    * Off
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 46
    Trioptic Code
    Trioptic Code is used for labeling magnetic storage media.
    GS1 Emulation
    The scanner can automatically format the output from any GS1 data carrier to 
    emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar  
    symbol.  GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, 
    ITF-14, GS1-128, and GS1-128 DataBar and GS1Composites.  If GS1-128 
    Emulation is selected, the AIM Symbology Identifier will be reported as “]C1”.  If 
    GS1 DataBar Emulation is selected, the AIM Symbology Identifier will be 
    reported as “]e0.”  Any application that accepts GS1 data can be simplified 
    since it only needs to recognize one data carrier type.  Default = GS1 Emulation 
    Off.
    On
    Off
    GS1 Data Bar Emulation
    GS1-128 Emulation
    * GS1 Emulation Off 
    						
    							6 - 47
    Label Code
    The standard Label Code is used in library situations.  Default = Off.
    On
    * Off 
    						
    							7 - 1
    7
    Interface Keys
    Keyboard Function Relationships
    The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII 
    “CTRL”+  relationships apply to all terminals that can be used with the scanner.  
    Refer to Windows Mode Control + X Mode On (page 2-20) to enable Control + 
    ASCII mode.
    Function Code HEX/ASCII Value Full ASCII “CTRL” +
    NUL 00 2
    SOH 01 A
    STX 02 B
    ETX 03 C
    EOT 04 D
    ENQ 05 E
    ACK 06 F
    BEL 07 G
    BS 08 H
    HT 09 I
    LF 0A J
    VT 0B K
    FF 0C L
    CR 0D M
    SO 0E N
    SI 0F O
    DLE 10 P
    DC1 11 Q
    DC2 12 R
    DC3 13 S
    DC4 14 T
    NAK 15 U
    SYN 16 V
    ETB 17 W
    CAN 18 X
    EM 19 Y
    SUB 1A Z
    ESC 1B [
    FS 1C \
    GS 1D ]
    RS 1E 6
    US 1F - 
    						
    							7 - 2
    Supported Interface Keys
    ASCIIHEX
    IBM AT/XT and 
    PS/2 Compatibles, 
    WYSE PC/AT
    Supported Keys
    NUL 00 Reserved
    SOH 01 Enter (KP)
    STX 02 Cap Lock
    ETX 03 ALT make
    EOT 04 ALT break
    ENQ 05 CTRL make
    ACK 06 CTRL break
    BEL 07 CR/Enter
    BS 08 Reserved
    HT 09 Tab
    LF 0A Reserved
    VT 0B Tab
    FF 0C Delete
    CR 0D CR/Enter
    SO 0E Insert
    SI 0F Escape
    DLE 10 F11
    DC1 11 Home
    DC2 12 Print
    DC3 13 Back Space
    DC4 14 Back Tab
    NAK 15 F12
    SYN 16 F1
    ETB 17 F2
    CAN 18 F3
    EM 19 F4
    SUB 1A F5
    ESC 1B F6
    FS 1C F7
    GS 1D F8
    RS 1E F9
    US 1F F10
    * IBM 3191/92, 3471/72, 3196/97, 3476/77,
    Telex (all models) 
    						
    							7 - 3
    Supported Interface Keys
    ASCIIHEX
    Apple Mac/iMac 
    Supported Keys
    NUL 00 Reserved
    SOH 01 Enter/Numpad Enter
    STX 02 CAPS
    ETX 03 ALT make
    EOT 04 ALT break
    ENQ 05 CNTRL make
    ACK 06 CNTRL break
    BEL 07 RETURN
    BS 08 APPLE make
    HT 09 TAB
    LF 0A APPLE break
    VT 0B TAB
    FF 0C Del
    CR 0D RETURN
    SO 0E Ins Help
    SI 0F ESC
    DLE 10 F11
    DC1 11 Home
    DC2 12 Prnt Scrn
    DC3 13 BACKSPACE
    DC4 14 LSHIFT TAB
    NAK 15 F12
    SYN 16 F1
    ETB 17 F2
    CAN 18 F3
    EM 19 F4
    SUB 1A F5
    ESC 1B F6
    FS 1C F7
    GS 1D F8
    RS 1E F9
    US 1F F10
    DEL 7F BACKSPACE 
    						
    							8 - 1
    8
    Utilities
    To Add a Test Code I.D. Prefix to All Symbologies
    This selection allows you to turn on transmission of a Code I.D. before the 
    decoded symbology.  (See the Symbology Charts (page A-1) for the single 
    character code that identifies each symbology.)  This action first clears all cur-
    rent prefixes, then programs a Code I.D. prefix for all symbologies.  This is a 
    temporary setting that will be removed when the unit is power cycled.
    Show Software Revision
    Scan the bar code below to output the current software revision, unit serial num-
    ber, and other product information.
    Show Data Format
    Scan the bar code below to show current data format settings.
    EZConfig-Scanning Introduction
    EZConfig-Scanning provides a wide range of PC-based programming functions 
    that can be performed on a scanner connected to your PCs COM port.  EZCon-
    fig-Scanning allows you to download upgrades to the scanners firmware, 
    Add Code I.D. Prefix to
    All Symbologies (Temporary)
    Show Revision
    Data Format Settings
    DFMBK3?. 
    						
    							8 - 2
    change programmed parameters, and create and print programming bar codes.  
    Using EZConfig-Scanning, you can even save/open the programming parame-
    ters for a scanner.  This saved file can be e-mailed or, if required, you can cre-
    ate a single bar code that contains all the customized programming parameters 
    and mail or fax that bar code to any location.  Users in other locations can scan 
    the bar code to load in the customized programming. 
    To communicate with a scanner, EZConfig-Scanning requires that the PC have 
    at least one available serial communication port, or a serial port emulation using 
    a physical USB port.  If you are using the serial port and RS232 cable, an exter-
    nal power supply is required.  When using a USB serial port emulation, only a 
    USB cable is required.
    EZConfig-Scanning Operations
    The EZConfig-Scanning software performs the following operations:
    Scan Data
    Scan Data allows you to scan bar codes and display the bar code data 
    in a window.  Scan Data lets you send serial commands to the scanner 
    and receive scanner response that can be seen in the Scan Data win-
    dow.  The data displayed in the Scan Data window can either be saved 
    in a file or printed. 
    Configure
    Configure displays the programming and configuration data of the 
    scanner.  The scanners programming and configuration data is 
    grouped into different categories.  Each category is displayed as a tree 
    item under the Configure tree node in the application explorer.  When 
    one of these tree nodes is clicked, the right-hand side is loaded with 
    the parameters form belonging to that particular category.  The Con-
    figure tree option has all the programming and configuration parame-
    ters specified for a scanner.  You can set or modify these parameters 
    as required.  You can later write the modified settings to the scanner, 
    or save them to a dcf file. 
    Installing EZConfig-Scanning from the Web
    1. Access the Honeywell web site at www.honeywellaidc.com
    2. Click on the Resources tab.  Select Download.
    3. Click on the dropdown for Select Product Number and select the 
    number of your product.
    4. Under Tools and Utilities, click on the listing for EZConfig for 
    Scanning.  
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell 1300g2 Owners Manual