    							bizhub 423/363/283/2231-7
    1.4 Precautions for Operation Control1
    Network Connection Requirements for the Machine
    Packets being transmitted over the LAN installed in the office, in which the machine is installed, should be 
    protected from unauthorized manipulation. If the LAN is to be connected to an outside network, no unautho-
    rized attempt to establish connection from the external network should be permitted.
    
    -If the LAN, in which the machine is installed, is connected to an outside network, install a firewall or 
    similar network device to block any access to the machine from the outside network and make the nec-
    essary settings.
    -Configure the LAN installed in the office, in which the machine is installed, by using a switching hub and 
    other devices to ensure that the packets are protected from unauthorized manipulation.
    -Provide an appropriate network control at all times to make sure that packets are protected from un-
    authorized manipulation and no other copying machine is connected without prior notice to the office 
    LAN to which this machine is connected.
    User information control server control requirements
    The server administrator is required to apply patches and control accounts for the user information control 
    server connected to the LAN within the office, in which this machine is installed, to ensure operation control 
    that achieves appropriate access control.
    Security function operation setting operating requirements
    The Administrator should make sure of correct operation control so that the machine is used with the En-
    hanced Security Mode set to [ON].
    Operation and control of the machine
    The Administrator of the machine should perform the following operation control.
    -The Administrator of the machine should log off from the Administrator Settings whenever the operation 
    in the Administrator Settings is completed. The Administrator of the machine should also make sure 
    that each individual user logs off from the User Authentication mode after the operation in the User Au-
    thentication mode is completed, including operation of the Secure Print Document, User Box, and User 
    Box file.
    -The Administrator of the machine should set the Encryption Key according to the environment, in which 
    this machine is used.
    Machine Maintenance Control
    The Administrator of the machine should perform the following maintenance control activities.
    -Provide adequate control over the machine to ensure that only the Service Engineer is able to perform 
    physical service operations on the machine.
    -Provide adequate control over the machine to ensure that any physical service operations performed 
    on the machine by the Service Engineer are overseen by the Administrator of the machine.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2231-8
    1.5 Miscellaneous1
    1.5 Miscellaneous
    Password Rules
    According to certain Password Rules, registration of a password consisting of a string of a single character 
    or change of a password to one consisting of a string of a single character is rejected for the Administrator 
    Password, User Password, Account Password, User Box Password, Secure Print Password, SNMP Pass-
    word, WebDAV Server Password, and Encryption Key. For the Administrator Password, User Password, Ac-
    count Password, User Box Password, SNMP Password, WebDAV Server Password, and Encryption Key, the 
    same password as that currently set is not accepted.
    Study the following table for details of the number of digits and characters that can be used for each pass-
    word.
    Precautions for Use of Umlaut
    -The maximum number of digits allowed for the User Password is 64, if umlaut is used with all charac-
    ters, however, the maximum number of digits allowed becomes 32 digits.
    -Setting or entering an umlaut from the control panel may be disabled depending on the setting made 
    in this machine, but not on the client PC side including PageScope Web Connection. If an umlaut is set 
    in a password on the PC side, therefore, the umlaut cannot be entered from the control panel, which 
    means that this particular password is not usable.
    Precautions for Use of Various Types of Applications
    Comply with the following requirements when using various types of applications.
    -When PageScope Web Connection or an application of various other types is used, the password con-
    trol function of the application stores the password that has been entered in your PC. If you want the 
    password not stored, disable the password control function of the application. 
    When using the PageScope Web Connection or an application of various other types, use one that 
    shows * or ● for the password entered.
    -Internet Explorer or other type of web browser, SSL v3 or TLS v1 should be used, not SSL v2, for 
    the SSL setting.
    -Expanded functions, which can be used in association with applications by registering the optional Li-
    cense Kit, are available, including collecting and controlling user and account information by means of 
    the WebDAV function. Use of these expanded functions is not covered by certification of ISO15408.
    Types of passwordsNo. of digitsCharacters
    User Password 8 digits • Numeric characters: 0 to 9
    • Alpha characters: upper and lower case letters
    • Symbols: !, #, $, %, &, , (, ), *, ,, -, ., /, :, ;, , 
    ?, @, [, \, ], ^, _, `, {, |, }, ~, +
    • Characters with umlaut (95 characters)
    Selectable from among a total of 188 characters
    Encryption Key 20 digits • Numeric characters: 0 to 9
    • Alpha characters: upper and lower case letters
    • Symbols: !, #, $, %, &, , *, +, -, ., /, =, ?, @, ^, _, `, 
    {, |, }, ~
    Selectable from among a total of 83 characters
    Administrator Password 8 digits • Numeric characters: 0 to 9
    • Alpha characters: upper and lower case letters
    • Symbols: !, #, $, %, &, , (, ), *, ,, -, ., /, :, ;, , 
    ?, @, [, \, ], ^, _, `, {, |, }, ~, +
    Selectable from among a total of 93 characters Account Password
    User Box Password
    Secure Print Password
    WebDAV Server Password
    SNMP Password
    • auth-Password
    • priv-Password8 digits or more • Numeric characters: 0 to 9
    • Alpha characters: upper and lower case letters
    • Symbols: !, $, %, &, (, ), *, ,, -, ., /, :, ;, , ?, @, 
    [, ], ^, _, `, {, |, }, ~, +
    Selectable from among a total of 90 characters
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2231-9
    1.5 Miscellaneous1
    Encrypting communications
    The following are the cryptographic algorithms of key exchange and communications encryption systems 
    supported in generation of encryption keys.
    -TLS_RSA_WITH_RC4_128_MD5
    -TLS_RSA_WITH_3DES_EDE_CBC_SHA
    -TLS_RSA_WITH_AES_128_CBC_SHA
    -TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA
    -TLS_DHE_RSA_WITH_AES_256_CBC_SHA
    NOTICE
    No algorithms can be selected during generation of encryption keys. SSL v3 is automatically selected for the 
    SSL setting according to the application and browser. Do not therefore change the setting manually to SSL 
    v2.
    Use the following browsers to ensure SSL encryption communication with appropriate strength. Use of any 
    of the following browsers achieves SSL encryption communication that ensures confidentiality of the image 
    data transmitted and received.
    Windows NT4.0, 2000, XP, Server2003, Vista, Server2008, Windows 7
    -Recommended is Microsoft Internet Explorer 6 or later.
    -Recommended is Netscape Navigator 7.02 or later.
    -Recommended is Mozilla Firefox 1.0 or later.
    Macintosh MacOS 9.x, MacOS X
    -Recommended is Netscape Navigator 7.02 or later.
    -Recommended is Mozilla Firefox 1.0 or later.
    Linux
    -Recommended is Netscape Navigator 7.02 or later.
    -Recommended is Mozilla Firefox 1.0 or later.
    SSL encryption communication with confidentiality properly maintained can be achieved in image data trans-
    mitted and received in any of the following applications.
    -PageScope Box Operator
    -HDD TWAIN
    -PageScope Direct Print
    -HDD Backup Utility
    NOTICE
    SSL encryption communication is not applicable to transmission of Secure Print in PageScope Direct Print.
    IPP printing
    IPP (Internet Printing Protocol) is a function that allows Secure Print Documents and image data stored in 
    boxes to be printed via the Internet by using the HTTP (HyperText Transfer Protocol) of the TCP/IP Protocol. 
    IPPS (IPP over SSL/TLS) is the type of IPP that performs the SSL encryption communication.
    
    To perform IPP printing, the printer driver must be installed. From Add Printer Wizard, select Connect to 
    a printer on the Internet or on a home or office network and type the URL of this machine in the following 
    format in the URL field. The printer, for which the settings have been made, can be used in the same manner 
    as the ordinary local printer.
    http://  /ipp
    E.g.: If the machine IP address is 192.168.1.20
    Type http://192.168.1.20/ipp
    To set IPPS printing:
    Type https://  /ipp.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2231-10
    1.5 Miscellaneous1
    
    Windows Vista/Server2008, which offers enhanced security functions, gives a certificate error message if the 
    SSL certificate is one that is not issued by a certification body. In such cases, it becomes necessary to reg-
    ister with Windows Vista the certificate of this machine as that issued by a reliable party for the computer 
    account.
    First, register Host Name and IP address of this machine in the DNS server in advance. Then, in TCP/IP Set-
    tings of PageScope Web Connection, set the DNS Host Name and DNS Default Domain Name registered 
    with the DNS server.
    It should also be noted that, for the certificate to be imported, a certificate for SSL encryption communication 
    should be registered in PageScope Web Connection and exported in advance as the certificate including the 
    public key.
    1From Continue to this website, call the PageScope Web Connection window to the screen.
    2Click Certificate Error to display the certificate. Then, click Install Certificate to install the certificate.
    3Display the physical stores. Then, deploy the certificate, which has earlier been exported, in Local 
    Computer of Trusted Root Certification Authorities to thereby import the certificate.
    
    Through additional printer setting, type https://Host Name.Domain Name/ipp.
    For [Host Name] and [Domain Name], specify the names set with the DNS server.
    Items of Data Cleared by Overwrite All Data Function
    The Overwrite All Data function clears the following items of data.
    Items of Data ClearedDescription
    User registration data Deletes all user-related data that has been registered
    Account registration data Deletes all account track-related data that has been registered
    Box registration data/fileDeletes all User Box-related information and files saved in User Box
    Secure Print ID/Password/
    DocumentDeletes all Secure Print Document-related information and files saved
    ID & Print Document Deletes all ID & Print Documents saved in ID & Print User Box
    Image files • Image files other than Secure Print Documents, ID & Print Docu-
    ments, and User Box files
    • Image files of jobs in the queue state
    • Data files left in the HDD data space, used as image files and not 
    deleted through the general deletion operation
    • Temporary data files generated during print image file processing
    Destination recipient data files Deletes all destination recipient data including e-mail addresses and 
    telephone numbers
    Encryption Key Clears the currently set Encryption Key
    Administrator Password Clears the currently set password, resetting it to the factory setting
    SNMP Password Clears the currently set password, resetting it to the factory setting 
    (MAC address)
    WebDAV Server Password Clears the currently set password, resetting it to the factory setting 
    (sysadm)
    S/MIME certificate Deletes the currently set S/MIME certificate
    Device certificate
    (SSL certificate)Deletes the currently set Device certificate (SSL certificate)
    Network Setting Clears the currently set network settings (DNS Server setting, IP Ad-
    dress setting, SMTP Server setting, NetWare Setting, NetBIOS setting 
    and AppleTalk Printer Name setting), resetting it to the factory setting
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2231-11
    1.5 Miscellaneous1
    Fax functions
    An optional Fax Kit is required for using fax functions. Contact your Service Representative.
    Bluetooth communication
    An optional Local Interface Kit is required for Bluetooth communication. Contact your Service Representa-
    tive.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							2Administrator Operations
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-2
    2.1 Accessing the Administrator Settings2
    2 Administrator Operations
    2.1 Accessing the Administrator Settings
    In Administrator Settings, the settings for the machine system and network can be registered or changed.
    This machine implements authentication of the user of the Administrator Settings function through the 8-digit 
    Administrator Password that verifies the identity as the Administrator of the person who accesses the func-
    tion. During the authentication procedure, the Administrator Password entered for the authentication purpose 
    appears as * or ● on the display.
    When the Enhanced Security Mode is set to [ON], the number of times in which authentication fails is count-
    ed.
    NOTICE
    Make sure that none of the general users of the machine will know the Administrator Password.
    If the Administrator Password is forgotten, it must be set again by the Service Engineer. Contact your Service 
    Representative.
    2.1.1 Accessing the Administrator Settings
    The machine does not accept access to the Administrator Settings under any of the following conditions. 
    Wait for some while before attempting to gain access to the Administrator Settings again.
    -The Administrator Settings has been logged on to through access made from the PC.
    -A remote operation is being performed from an application on the PC.
    -There is a job being executed by the machine.
    -There is a reserved job (timer TX, fax redial waiting, etc.) in the machine.
    -Immediately after the main power switch has been turned ON.
    -A malfunction code is displayed on the machine.
    
    0When accessing the Administrator Settings from the control panel, if you have already logged on to the 
    Administrator Settings using PageScope Web Connection, the machine displays a message that tells 
    not to turn off the power because of the remote operation being performed and rejects any operation 
    on the control panel. Wait until the message disappears before attempting to access the Administrator 
    Settings once again.
    0When accessing the Administrator Settings from the control panel, if [Export to the device] operation is 
    being executed using the PageScope Data Administrator, the machine displays a message that tells 
    not to turn off the power because of the remote operation being performed and rejects any operation 
    on the control panel. Wait until the message disappears before attempting to access the Administrator 
    Settings once again.
    0Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If 
    it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings.
    1Press the [Utility/Counter] key.
    2Touch [Administrator Settings].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-3
    2.1 Accessing the Administrator Settings2
    3Enter the 8-digit Administrator Password from the keyboard or keypad.
    %Press the [C] key to clear all characters.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    %Touch [Cancel] to go back to the screen shown in step 2.
    4Touch [OK].
    %If a wrong Administrator Password is entered, a message that tells that the Administrator Password 
    does not match appears. Enter the correct Administrator Password.
    %If the Enhanced Security Mode is set to [ON], entry of a wrong password is counted as unauthorized 
    access. If a wrong Administrator Password is entered a predetermined number of times (once to 
    three times) or more set by the Administrator of the machine, a message appears saying that the 
    machine accepts no more Administrator Passwords because of unauthorized access for any sub-
    sequent entry of the Administrator Password. The machine is then set into an access lock state. To 
    cancel the access lock state, settings must be made by the Service Engineer; or, turn off, and then 
    turn on, the main power switch of the machine. If the main power switch is turned off and on, the 
    access lock state is canceled after the lapse of time set for [Release Time Settings]. When the main 
    power switch is turned off, then on again, wait at least 10 seconds to turn it on after turning it off. If 
    there is no wait period between turning the main power switch off, then on again, the machine may 
    not function properly.
    Here is the sequence, through which the main power switch and sub power switch are turned on 
    and off:
    Turn off the sub power switch →
     Turn off the main power switch → Turn on the main power switch 
    → Turn on the sub power switch
    5Press the [Utility/Counter] key to log off from the Administrator Settings.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-4
    2.1 Accessing the Administrator Settings2
    2.1.2 Accessing the User Mode
    You can log on to the User Mode as an Administrator. In the User Mode, you can check or delete a job, which 
    is disabled in Administrator Settings.
    Reference
    -The authority relating to box settings is the same as that of Administrator Settings.
    
    0The Administrator must first make User Authentication settings before he or she can access User Mode. 
    For details of the User Authentication, see page 2-17.
    0Do not leave the machine with the User Mode setting screen left shown on the display. If it is absolutely 
    necessary to leave the machine, be sure first to log off from the User Mode.
    1Touch [User Name].
    2Type admin in User Name.
    %Press the [C] key or touch [Undo] to clear the value entered last.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    3Touch [OK].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-5
    2.1 Accessing the Administrator Settings2
    4Touch [Password].
    5Enter the 8-digit Administrator Password from the keyboard or keypad.
    %Press the [C] key to clear all characters.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    %Touch [Cancel] to go back to the screen shown in step 4.
    6Touch [OK].
    7Press [Access] or touch [Login].
    %If a wrong Administrator Password is entered, a message that tells that the authentication has failed 
    appears. Enter the correct Administrator Password.
    %If the Enhanced Security Mode is set to [ON], entry of a wrong password is counted as unauthorized 
    access. If a wrong Administrator Password is entered a predetermined number of times (once to 
    three times) or more set by the Administrator of the machine, a message appears saying that the 
    machine accepts no more Administrator Passwords because of unauthorized access for any sub-
    sequent entry of the Administrator Password. The machine is then set into an access lock state. To 
    cancel the access lock state, settings must be made by the Service Engineer; or, turn off, and then 
    turn on, the main power switch of the machine. If the main power switch is turned off and on, the 
    access lock state is canceled after the lapse of time set for [Release Time Settings]. When the main 
    power switch is turned off, then on again, wait at least 10 seconds to turn it on after turning it off. If 
    there is no wait period between turning the main power switch off, then on again, the machine may 
    not function properly.
    Here is the sequence, through which the main power switch and sub power switch are turned on 
    and off:
    Turn off the sub power switch → Turn off the main power switch → Turn on the main power switch 
    → Turn on the sub power switch
    8Press the [Access] key to log off from the User Mode.
    Downloaded From ManualsPrinter.com Manuals 
    						