Home > Konica > Printer > Konica Minolta bizhub 363 User Manual

Konica Minolta bizhub 363 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Konica Minolta bizhub 363 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 61 Konica manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							bizhub 423/363/283/2232-66
    2.15 S/MIME Communication Setting Function2
    
    0For the procedure to access the Admin Mode, see page 2-2.
    0Do not leave the machine with the Admin Mode setting screen left shown on the display. If it is abso-
    lutely necessary to leave the machine, be sure first to log off from the Admin Mode.
    1Start PageScope Web Connection and access the Admin Mode.
    2Select [E-mail Setting] from the pull-down menu of Network and click [Display].
    3Click [S/MIME] from the [E-mail Setting] menu.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-67
    2.15 S/MIME Communication Setting Function2
    4Make the necessary settings.
    %For encryption method, select the strong 3DES, AES-128, AES-192, or AES-256. If the mail 
    software being used does not support AES, encrypted mail messages may be received, but they 
    cannot be decrypted. Use AES-compliant mail software or select the encryption method that is the 
    strongest of all compliant with the currently used mail software.
    %Each encryption method represents the following.
    Name: encryption algorithm: encryption key length
    3DES: 3 key triple DES: 168 bits
    AES-128: AES: 128bit
    AES-192: AES: 192bit
    AES-256: AES: 256bit
    %In the Enhanced Security Mode, the setting cannot be changed to RC2 or DES.
    5Click [OK].
    6Click [OK].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-68
    2.15 S/MIME Communication Setting Function2
    2.15.2 Registering the certificate
    0For the procedure to access the Admin Mode, see page 2-2.
    0Do not leave the machine with the Admin Mode setting screen left shown on the display. If it is abso-
    lutely necessary to leave the machine, be sure first to log off from the Admin Mode.
    1Start PageScope Web Connection and access the Admin Mode.
    2Select [Address Book] from the pull-down menu of Store Address and click [Display].
    3Click [New Registration].
    %To change the details of a previously registered destination, click [Edit].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-69
    2.15 S/MIME Communication Setting Function2
    4Select [E-mail] and click [OK].
    5Click to select the [Registration of Certification Information] check box, and through [Browse], set the 
    certificate information. If certificate information is to be deleted, select [Deletion of Certification Infor-
    mation].
    %Set 1024 bits or more for the key length of the RSA public key for the certificate of each destination.
    6Make the necessary settings.
    %A number that already exists cannot be redundantly registered.
    %If Name and E-mail Address have not been registered, a message appears that tells that Name and 
    E-mail Address are yet to be entered. Enter the correct Name and E-mail Address.
    7Click [OK].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-70
    2.16 SNMP Setting Function2
    2.16 SNMP Setting Function
    When access to the machine by the Administrator of the machine through the Administrator Settings is au-
    thenticated, the machine enables changing of the SNMP v3 Write User Password (auth-password, priv-pass-
    word) required for accessing the MIB object over the network using the SNMP from the PC. In PageScope 
    Web Connection, import/export of the Device Setting is enabled, allowing the setting for Security Level of 
    SNMP v3 Setting to be saved or the saved backup data to be restored.
    Each of the auth-password and priv-password can consist of 8 to 32 digits. The password entered for the 
    authentication purpose appears as * or ● on the display.
    2.16.1 Changing the auth-password and priv-password
    
    0For the procedure to call the Administrator Settings on the display, see page 2-2.
    0Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If 
    it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings.
    1Call the Administrator Settings on the display from the control panel.
    2Touch [Network Settings].
    3Touch [SNMP Settings].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-71
    2.16 SNMP Setting Function2
    4Touch [Forward] to show [2/3] and touch [SNMP v3 Settings].
    5Touch [Forward] to show [4/5] SNMPv3/Write Settings screen.
    6Select [auth-password] or [auth-password/priv-password] of Security Level and touch [Password Set-
    ting].
    7Touch [Write auth].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-72
    2.16 SNMP Setting Function2
    %When a screen appears that prompts you to enter the current password, enter the MAC Address 
    that is set in the machine. To check the MAC Address, from [Network Settings] of step 2, select [For-
    ward] → [Detail Settings] → [Device Setting].
    %The entry of a wrong SNMP password (auth-password, priv-password) is counted as unauthorized 
    access, if the Enhanced Security Mode is set to [ON]. If a wrong SNMP password (auth-password, 
    priv-password) is entered a predetermined number of times (once to three times) or more set by the 
    Administrator of the machine, the machine is set into an access lock state, rejecting any more logon 
    attempts. To cancel the access lock state, perform the Release Setting by the Administrator of the 
    machine.
    8Enter the new 8-digit-or-more auth-password from the keyboard or keypad.
    %Press the [C] key to clear all characters.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    %Touch [Cancel] to go back to the previous screen.
    9Touch [OK].
    %If the entered auth-password does not meet the requirements of the Password Rules, a message 
    that tells that the entered auth-password cannot be used appears. Enter the correct auth-password. 
    For details of the Password Rules, see page 1-8.
    10To prevent entry of a wrong password, enter the auth-password again.
    %Press the [C] key to clear all characters.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    %Touch [Cancel] to go back to the previous screen.
    11Touch [OK].
    %Go to step 12 if [auth-password/priv-password] is selected in step 6.
    %If the entered auth-password does not match, a message that tells that the auth-password does not 
    match appears. Enter the correct auth-password.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-73
    2.16 SNMP Setting Function2
    12Touch [Write priv].
    %When a screen appears that prompts you to enter the current password, enter the MAC Address 
    that is set in the machine. To check the MAC Address, from [Network Settings] of step 2, select [For-
    ward] → [Detail Settings] → [Device Setting].
    %The entry of a wrong SNMP password (auth-password, priv-password) is counted as unauthorized 
    access, if the Enhanced Security Mode is set to [ON]. If a wrong SNMP password (auth-password, 
    priv-password) is entered a predetermined number of times (once to three times) or more set by the 
    Administrator of the machine, the machine is set into an access lock state, rejecting any more logon 
    attempts. To cancel the access lock state, perform the Release Setting by the Administrator of the 
    machine.
    13Enter the new 8-digit-or-more priv-password from the keyboard or keypad.
    %Press the [C] key to clear all characters.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    %Touch [Cancel] to go back to the previous screen.
    14Touch [OK].
    %If the entered priv-password does not meet the requirements of the Password Rules, a message 
    that tells that the entered priv-password cannot be used appears. Enter the correct priv-password. 
    For details of the Password Rules, see page 1-8.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-74
    2.16 SNMP Setting Function2
    15To prevent entry of a wrong password, enter the priv-password again.
    %Press the [C] key to clear all characters.
    %Touch [Delete] to delete the last character entered.
    %Touch [Shift] to show the upper case/symbol screen.
    %Touch [Cancel] to go back to the previous screen.
    16Touch [OK].
    %If the entered priv-password does not match, a message that tells that the priv-password does not 
    match appears. Enter the correct priv-password.
    17Touch [Close] and [OK].
    Downloaded From ManualsPrinter.com Manuals 
    						
    							bizhub 423/363/283/2232-75
    2.16 SNMP Setting Function2
    
    0For the procedure to access the Admin Mode, see page 2-2.
    0Do not leave the machine with the Admin Mode setting screen left shown on the display. If it is abso-
    lutely necessary to leave the machine, be sure first to log off from the Admin Mode.
    1Start PageScope Web Connection and access the Admin Mode.
    2Select [SNMP Setting] from the pull-down menu of Network and click [Display].
    3Enter the auth-password and priv-password in the boxes marked by the rectangle, that is, the Write 
    side SNMP v3 Setting.
    %For the current password, enter the MAC Address that is set in the machine. To check the MAC Ad-
    dress, see step 7 of page 2-70.
    %The entry of a wrong SNMP password (auth-password, priv-password) is counted as unauthorized 
    access, if the Enhanced Security Mode is set to [ON]. If a wrong SNMP password (auth-password, 
    priv-password) is entered a predetermined number of times (once to three times) or more set by the 
    Administrator of the machine, the machine is set into an access lock state, rejecting any more logon 
    attempts. To cancel the access lock state, perform the Release Setting by the Administrator of the 
    machine.
    Downloaded From ManualsPrinter.com Manuals 
    						
    All Konica manuals Comments (0)

    Related Manuals for Konica Minolta bizhub 363 User Manual