Page 311

NDA-24305 CHAPTER 6
Page 293
Revision 1.0
Q-SIG (CIRCUIT SWITCHED BASIC CALL - ETSI VERSION)
Note 3:
Assign “1” when the number display on LCD of terminal is required.
Note 4:Assign “1” when the User-to-User Signaling notification is required.
Note 5:Assign “1” when the multi-rate bearer service is used.
STEP 4: ARTI - Assign the trunk application data for Bch and Dch as follows. 
INTD=0 (Q-SIG)
Note:This data is effective since release 4.
STEP 5: ATRK - Assign Bch trunk data. Note that Dch trunk data...

Page 312

CHAPTER 6 NDA-24305
Pag e 2 94
Revision 1.0
ADVICE OF CHARGE (AOC) - RECEIPT AND DISPLAY OF AOC FROM A FOREIGN Q-SIG NETWORK
A-136 ADVICE OF CHARGE (AOC) - RECEIPT AND DISPLAY OF AOC FROM A FOREIGN Q-SIG 
NETWORK
1. General Description
This feature provides the calling station originated a call to ISDN network using Q-SIG/IS-11572 line with the
charge information display sent from the ISDN network. Whether the charge information is displayed or not can
be specified on a station basis.
2. Operating...

Page 313

NDA-24305 CHAPTER 6
Page 295
Revision 1.0
ADVICE OF CHARGE (AOC) - RECEIPT AND DISPLAY OF AOC FROM A FOREIGN Q-SIG NETWORK
4. Interactions
1. When Call Transfer - All Calls service/Blind Transfer Service is activated with this feature, the call charge
is not sent to the calling station. However, when Call Transfer - All Calls  is activated with this feature, the
call charge is sent to the forwarding station.
2. When Call Forwarding - Busy Line [C-2], Call Forwarding - All Calls [C-5] is activated with...

Page 314

CHAPTER 6 NDA-24305
Pag e 2 96
Revision 1.0
ADVICE OF CHARGE (AOC) - RECEIPT AND DISPLAY OF AOC FROM A FOREIGN Q-SIG NETWORK
5. Example of Message Sequence
Some examples of message sequence for this service are shown below.
Station A calls to Station B and the two stations are connected.
ETSI/ 
IS-11572ISDN 
network
Station B Station A
(1)
Message Sequence of charge information sent when the call is disconnected from a called user 
(2) Message Sequence of charge information sent when the call is...

Page 315

NDA-24305 CHAPTER 6
Page 297
Revision 1.0
ADVICE OF CHARGE (AOC) - RECEIPT AND DISPLAY OF AOC FROM A FOREIGN Q-SIG NETWORK
6. Programming
STEP 1: Assign the data for establishing Q-SIG/IS-11572 line followed by “Q-SIG (CIRCUIT SWITCHED
BASIC CALL - ETSI VERSION)” or “IS-11572 (LAYER 3 SPECIFICATIONS FOR INTER-PBX
SIGNALING PROTOCOL)” in this chapter. Also, assign the data for “STATION MESSAGE
DETAIL RECORDING SYSTEM-RS232C-PRI” [S-83] in Chapter 5.
STEP 2: ASFC – Assign the service feature class to be...

Page 316

CHAPTER 6 NDA-24305
Pag e 2 98
Revision 1.0
This page is for your notes. 