    Have a look at the manual Netgear Readynas 628x Ultimate Performance Business Data Storage 8 Bay Hardware Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 137 Netgear manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Environmental requirements:
    •Operating temperature: 0 to 40°C (32° to 104°F)
    •Operating humidity: 20 to 80% relative humidity (noncondensing)
    •Storage temperature: –20 to 70°C (–4 to 158°F)
    •Storage humidity: 5 to 95% relative humidity (noncondensing)
    •Software-controlled 120 mm chassis cooling fan
    Certifications:
    FCC Class B, CE Class B, RoHS, VCCI Class B, CCC, MIC, BIS
    ReadyNAS 626X Technical Specifications
    The ReadyNAS 626X storage system meets the following technical specifications:
    General:
    •Intel Xeon processor D-1521
    •8GB ECC DDR4 memory
    •Six-bay storage
    •One eSATA port
    •One USB 3.0 port (front)
    •Two USB 3.0 ports (back)
    •Two 1 GbE LAN ports
    •Two 10 Gbe LAN ports
    •OLED display
    Physical dimensions (h x w x d):
    260 x 190 x 280 mm (10.24 x 7.48 x 11.02 in.)
    Physical weight:
    7.9 kg (17.4 lb) without disks
    Defaults and Technical Specifications
    151
    ReadyNAS OS 6.5 
    						
    							Power consumption:
    •BTU at full power supply utilization: 100W
    •In operation: 70.5W
    •Power off (Wake On LAN): 310 mW
    •Power off: 264 mW
    Electrical:
    •Internal 200W server-rated AC power supply
    •Input: 100–240 VAC, 50/60 Hz
    Environmental requirements:
    •Operating temperature: 0 to 40°C (32° to 104°F)
    •Operating humidity: 20 to 80% relative humidity (noncondensing)
    •Storage temperature: –20 to 70°C (–4 to 158°F)
    •Storage humidity: 5 to 95% relative humidity (noncondensing)
    •Software-controlled 120 mm chassis cooling fan
    Certifications:
    FCC Class B, CE Class B, RoHS, VCCI Class B, CCC, MIC, BIS
    ReadyNAS 716X Technical Specifications
    The ReadyNAS 716X storage system meets the following technical specifications:
    General:
    •Intel Xeon processor E3-1265L v2 CPU
    •16 GB ECC memory
    •Six-bay storage
    •Three eSATA ports
    •One HDMI port
    •One USB 2.0 port (front)
    •Two USB 3.0 ports (back)
    •Two 1 GbE LAN ports
    Defaults and Technical Specifications
    152
    ReadyNAS OS 6.5 
    						
    							•Two 10 GbE LAN ports
    •LCD display
    •Infrared remote receiver
    •Proximity sensor
    Physical dimensions (h x w x d):
    259 x 192 x 287.5 mm (10.20 x 7.56 x 11.32 in.)
    Physical weight:
    8.20 kg (18.04 lb) without disks
    Power consumption:
    •BTU at full power supply utilization: 172.79W
    •In operation: 96.15W
    •Power off (Wake On LAN): 799.89 mW
    •Power off: 419.62 mW
    Electrical:
    •Internal 200W server-rated AC power supply
    •Input: 100-240 VAC, 50/60 Hz
    Environmental requirements:
    •Operating temperature: 0 to 40°C (32° to 104°F)
    •Operating humidity: 20 to 80% relative humidity (noncondensing)
    •Storage temperature: -20 to 70°C (-4 to 158°F)
    •Storage humidity: 5 to 95% relative humidity (noncondensing)
    •Software-controlled 120 mm chassis cooling fan
    Certifications:
    FCC Class B, CE Class B, RoHS, VCCI Class B
    Defaults and Technical Specifications
    153
    ReadyNAS OS 6.5 
    						
    							EDA 500 Technical Specifications
    The EDA 500 storage system meets the following technical specifications:
    General:
    •Five-bay storage
    •One eSATA port
    •Proximity sensor
    Physical dimensions (h x w x d):
    259 x 192 x 287.5 mm (10.20 x 7.56 x 11.32 in.)
    Physical weight:
    7.3 kg (16.1 lb) without disks
    Power consumption:
    •BTU at full power supply utilization: 88.17W
    •In operation: 37.3W
    •Power off: 453.8 mW
    Electrical:
    •Internal 200W server-rated AC power supply
    •Input: 100-240 VAC, 50/60 Hz
    Environmental requirements:
    •Operating temperature: 0 to 40°C (32° to 104°F)
    •Operating humidity: 20 to 80% relative humidity (noncondensing)
    •Storage temperature: -20 to 70°C (-4 to 158°F)
    •Storage humidity: 5 to 95% relative humidity (noncondensing)
    •Software controlled 120 mm chassis cooling fan
    Defaults and Technical Specifications
    154
    ReadyNAS OS 6.5 
    						
    							Certifications:
    FCC Class B, CE Class B, RoHS, VCCI Class B
    Safety Warnings
    •The equipment contains no operator access areas and is certified for installation only by trained personnel,
    according to the installation instructions provided with each storage system.
    •Install the socket-outlet near the equipment in an easily accessible location.
    •Observe the on-board battery precautions.
    Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
    according to their instructions.
    Note
    •Connect the storage systems and their associated LAN connections only to equipment within the same
    building.
    Electrical Safety Precautions
    Follow basic electrical safety precautions to protect yourself from harm and the ReadyNAS from damage:
    •Be aware of the locations of the power on/off switch on the chassis as well as the rooms emergency
    power-off switch, disconnection switch, or electrical outlet. If an electrical accident occurs, you can then
    quickly remove power from the system.
    •Do not work alone when working with high-voltage components.
    •Always disconnect power from the system when removing or installing main system components, such
    as the main board or memory modules.When disconnecting power, first power down the system with
    the operating system and then unplug the power cords of all the power supply storage systems in the
    system.
    •When working around exposed electrical circuits, ensure that another person who is familiar with the
    power-off controls is nearby to switch off the power if necessary.
    •Use only one hand when working with powered-on electrical equipment.This is to avoid making a
    complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which
    can easily damage any electrical components or circuit boards they come into contact with.
    •Do not use mats designed to decrease static electrical discharge as protection from electrical shock.
    Instead, use rubber mats that have been specifically designed as electrical insulators.
    •Use only power supply cords that include a grounding plug and plug them into grounded electrical
    outlets.
    General Safety Precautions
    Follow these rules to ensure general safety:
    Defaults and Technical Specifications
    155
    ReadyNAS OS 6.5 
    						
    							•Keep the area around the ReadyNAS clean and free of clutter.
    •See the technical specifications in this manual for details about your specific ReadyNAS storage systems.
    •Replace the on-board battery only with the same battery or an equivalent type of battery recommended
    by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
    Installing the battery upside down reverses its polarities and creates a danger of
    explosion.
    Note
    •Only trained service technicians can replace the soldered-in self-resetting PTC (positive temperature
    coefficient) fuses on the main board, using only new fuses that are the same as or equivalent to the
    ones being replaced. Contact technical support for details and support.
    Electrostatic Discharge Precautions
    Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact
    with each other. An electrical discharge is created to neutralize this difference, which can damage electronic
    components and printed circuit boards.The following measures are generally sufficient to neutralize this
    difference before contact is made to protect your equipment from ESD:
    •Use a grounded wrist strap designed to prevent static discharge.
    •Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.
    •Touch a grounded metal object before removing the board from the antistatic bag.
    •Do not let components or PCBs come into contact with your clothing, which might retain a charge even
    if you are wearing a wrist strap.
    •Handle a board by its edges only; do not touch its components, peripheral chips, memory modules, or
    contacts.
    •When handling chips or modules, avoid touching their pins.
    •Put the main board and peripherals back into their antistatic bags when not in use.
    •For grounding purposes, make sure your computer chassis provides excellent conductivity between the
    power supply, the case, the mounting fasteners, and the main board.
    Defaults and Technical Specifications
    156
    ReadyNAS OS 6.5 
    						
    All Netgear manuals Comments (0)

    Related Manuals for Netgear Readynas 628x Ultimate Performance Business Data Storage 8 Bay Hardware Manual