Home > Panasonic > Music Mixer > Panasonic Digital AV Mixer Agmx70 Operating Instructions

Panasonic Digital AV Mixer Agmx70 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Digital AV Mixer Agmx70 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							81
    TYPE
    The data playback format will be displayed.
    When double-clicked, the Properties window (page 86)
    will open.
    7OFF
    The operation at the time of DSK OFF will be displayed.
    The display contents are the same as for DSK ON.
    When double-clicked, the Properties window (page 86)
    will open.
    8
    NAME/COMMENT
    The name given to the data and the comment string will
    be displayed.
    When double-clicked, the Properties window (page 86)
    will open.
    9
    Duration
    (This appears only when Auto Trigger of
    DSK OFF is valid.)
    Screen descriptions
    Data playback format
    Still
    Movie Once
    Movie Repeat
    Crawl
    Roll
    ON
    The operation at the time of DSK ON will be displayed.
    When double-clicked, the Properties window (page 86)
    will open.
    6ICON
    The image is reduced and displayed.  When several files
    are used with one title, one of them will be used for the
    display.  The aspect ratio of the reduced image changes
    according to the memory setting (16:9/4:3) of the main
    unit.
    When double-clicked, the image display screen (page
    89) opens and the original image can be checked.
    5
    Special
    effects and
    effect time
    Slide
    settingTrigger setting
    AutoTrigger is valid.
    The time taken for DSK ON
    to be established is
    displayed at the side.
    AutoTrigger is not valid.
    D, F
    The upper line shows the Divide value for the data and
    the lower line shows the number of images of the data.
    4 
    						
    							82
    OFF
    The operation at the time of DSK OFF will be displayed.
    The display contents are the same as for DSK ON.
    When double-clicked, the Properties window (page 86)
    will open.
    8
    NAME/COMMENT
    The name given to the data will be displayed.
    When double-clicked, the Properties window (page 86)
    will open.
    9
    Screen descriptions
    TYPE
    The data playback format will be displayed.
    When double-clicked, the Properties window (page 86)
    will open.
    7
    Duration(This appears only when Auto
    Trigger of DSK OFF is valid.)
    Data playback format
    Still
    Movie Once
    Movie Repeat
    Crawl
    Roll
    List mode
    1
    2
    3456789
    For data with a Mark setting, the Mark number is
    displayed.1
    This is displayed for data with the Protect setting.2
    O (Order)
    The order of the data in the transmission list is displayed.
    This is the same as with icon mode.
    3
    D
    The Divide value of the data is shown.
    4
    F
    The number of images of the data is shown.
    5
    ON
    The operation at the time of DSK ON will be displayed.
    When double-clicked, the Properties window (page 86)
    will open.
    6
    Special effects Slide setting Trigger setting
    The yellow frame is the cursor.  The data marked by the cursor will be the object for transmission, deletion, memory clearing,
    property setting, etc.
    When the mouse is left-clicked on data, the cursor will move to that data.  When “Ctrl” is held down, several titles can be
    selected by left-clicking, and when “Shift is held down, the titles between the first click and the last click will be selected.
    When several titles are selected, the data selected first will be the object for Properties settings and screen display.  For other
    operations, all selected titles will be the object.
    
    For the setting contents for DSK ON and DSK OFF, refer to “Setting the title data playback properties” (page 86). 
    						
    							83
    Menu descriptions
    File menu
    Creation of a new list
    This clears the current transmission list and creates a new
    one (refer to page 86).  The same operation can be
    performed with the operation button  .
    Open image
    This opens an image and adds the title data at the end of
    the transmission list.  The same operation can be performed
    with the operation button  .
    Open List
    This clears the current transmission list and opens a
    previously saved transmission list.  The same operation can
    be performed with the operation button  .
    Save List
    This overwrites and saves the current transmission list.
    If the current transmission list does not have a name, the
    operation becomes the same as with “Save List as...”
    The same operation can be performed with the operation
    button .
    Save List as...
    This saves the current transmission list with a new name.
    Preview
    This opens the image display screen and displays the image
    of the title selected by the cursor.  The same operation can
    be performed by double-clicking the ICON column of the
    data display and selecting “Preview” from the pop-up menu.
    Property
    This opens the Properties setting screen for the title
    selected by the cursor.
    The same operation can be performed by double-clicking
    the column IN, TYPE, OUT, NAME of the title data display
    or by right-clicking the title data and selecting “Property”
    from the displayed menu.
    Read flash memory
    This reads the data (SETUP menu settings, operation panel
    settings, etc.) in the flash memory of the AG-MX70, and
    saves it in files.
    Select this menu item after turning on the power while
    holding down the “0” key and “5” key on the operation panel
    of the AG-MX70 and setting the AG-MX70 to the flash
    memory backup mode.  A dialog box now appears so input
    the file name and click the “OK” button to save the flash
    memory data.
    Write Flash memory
    This writes the data of the saved file into the flash memory
    of the AG-MX70.
    Select this menu item after turning on the power while
    holding down the “0” key and “5” key on the operation panel
    of the AG-MX70 and setting the AG-MX70 to the flash
    memory backup mode.  A dialog box now appears so select
    the file and click the “OK” button to write the file data.  When
    this operation is performed, all the data in the flash memory
    of the AG-MX70 is replaced.
    Exit
    This shuts down the program.
    Edit menu
    Undo
    This undoes data additions, deletions and other operations.
    Up to 16 steps can be undone.
    The same operation can be performed by pressing “Ctrl” +
    “Z.”
    Redo
    This cancels the contents of the Undo.
    The same operation can be performed by pressing “Ctrl” +
    “Y.”
    Cut
    This deletes the selected title from the transmission list and
    saves it to the clipboard.  The saved title can be added to
    the transmission list via the “Paste” menu.  Only the title cut
    last will be saved.
    The same operation also can be performed by “Ctrl” + “X” or
    by right-clicking the title data display column and selecting
    “Cut” from the pop-up menu.
    Copy
    This copies the selected title to the clipboard.
    The saved title can be added to the transmission list via the
    “Paste” menu.  Only the title cut last will be saved.
    The same operation can be performed with “Ctrl” + “C” or by
    right-clicking the title data display column and selecting
    “Copy” from the pop-up menu.
    Paste
    This adds the title saved on the clipboard to the
    transmission list.
    The same operation can be performed with “Ctrl” + “V” or by
    right-clicking the title data display column and selecting
    “Paste” from the pop-up menu. 
    						
    							84
    Menu descriptions
    Delete
    This deletes the selected title from the transmission list.
    The same operation can be performed with the “DEL” key or
    by right-clicking on the title data display column and
    selecting “Delete” from the pop-up menu.
    Select all
    This selects all titles in the transmission list.
    The same operation can be performed by pressing “Ctrl” +
    “A.”
    View menu
    ICON view
    This switches the display mode for the main screen to icon
    mode.
    The same operation can be performed by right-clicking the
    data display and selecting “View” >“ICON view” from the
    displayed pop-up menu.
    LIST view
    This switches the display mode for the main screen to list
    mode.
    The same operation can be performed by right-clicking the
    data display and selecting “View” >“LIST view” from the
    displayed pop-up menu.
    Sort by name
    This rearranges the data of the transmission list by the
    Name character order.
    The same operation can be performed with the  , 
    buttons in the Name heading part of the data display.
    Sort by comments
    This rearranges the transmission list by the Comment
    character order.
    The same operation can be performed with the  , 
    buttons in the Comment heading part of the data display.
    Cursor menu
    Top
    This moves the cursor to the start of the transmission list.
    The same operation can be performed with the operation
    button  or with the HOME key.
    Jump to 10th Previous
    This moves the cursor up 10 from the present position.
    The same operation can be performed with the operation
    button  or with the Left arrow key.
    Previous
    This moves the cursor up one from the present position.
    The same operation can be performed with the operation
    button  or with the Up arrow key.
    Next
    This moves the cursor down one from the present position.
    The same operation can be performed with the operation
    button  or with the Down arrow key.
    Jump to  10th Next
    This moves the cursor down 10 from the present position.
    The same operation can be performed with the operation
    button  or with the Right arrow key.
    Bottom
    This moves the cursor to the end of the transmission list.
    The same operation can be performed with the operation
    button  or with the END key.
    Jump to the Current DSK Title
    This moves the cursor to the title being played.
    The same operation can be performed with the number key
    0.
    Jump to the marked Title
    This moves the cursor to a title with a Mark setting.
    Select Mark1 to Mark9 from the submenu.
    The same operation can be performed with the number keys
    1 to 9. 
    						
    							85
    Menu descriptions
    Tool menu
    Memory status
    This displays the memory status screen.  For details, refer
    to “Checking the memory status of the AG-MX70” (page 90).
    AG-MX70 setup
    This displays the memory setting screen.  For details, refer
    to “Changing the AG-MX-70 memory settings” (page 90)
    and “Recalling events” (page 91.)
    Properties initial value setting
    This displays the Properties initial value setting screen.  For
    details, refer to “Initial set of Property data” (page 92).
    Operating environment
    This displays the Operating environment screen.  For
    details, refer to “Setting the operating environment” (page
    93).
    Help menu
    Help
    This displays the Help contents.
    The same operation can be performed with the operation
    button .
    Version
    This displays the version of this application.
    Operation menu
    (effective only when the AG-MX70 is connected)
    AutoLoad
    This automatically transmits the data from the selected data
    to the end of the list and performs DSK playback.  For
    details, refer to “Automatic transmission and playback of
    Title data” (page 88).
    The same operation can be performed with the operation
    button or with “Shift” + “Space.”
    Load Title
    This transmits the selected data.  For details, refer to
    “Manual transmission and playback of Title data” (page 88).
    The same operation can be performed with the operation
    button  or with the L key.
    Play
    This performs DSK playback for the selected data.  When
    the data has not yet been transmitted, DSK playback will be
    performed after transmission.  For details, refer to “Manual
    transmission and playback of Title data” (page 88).
    The same operation can be performed with the operation
    button or with “Space.”
    Stop
    This stops DSK playback.
    The same operation can be performed with the operation
    button .
    Clear the selected title
    This clears the selected data from the image memory of the
    AG-MX70.  For details, refer to “Clearing Title data” (page
    90).
    The same operation can be performed with the operation
    button or with “Ctrl” + “R.”
    Clear all titles
    This clears all data in the transmission list from the image
    memory of the AG-MX70.  For details, refer to “Clearing
    Title data” (page 88).
    The same operation can be performed with the operation
    button or with “Ctrl” + “T.”
    Auto Take
    This executes Auto Take using the AG-MX70. 
    						
    							86
    Title data operations
    Flow until Title data playback
    The procedure for transmission of PC images as Title data
    and DSK playback is as follows.
    1) Register the image in the list of Title data for
    transmission to the AG-MX70 (transmission list).
    2) Perform data playback settings.
    3) Play back and transmit data manually or
    automatically.
    Registering Title data in the transmission list
    The transmission list is a list of Title data to be transmitted
    to the AG-MX70.  Up to 99 Title data items can be
    registered in the transmission list.  Images can be registered
    as Title data in the transmission list using the following
    procedure.
    1) Select “Open image” from the “File” menu of the main
    window.  The “Open file” dialog will open.
    2) Select the image to be transmitted.  When playback
    as MOVIE, ROLL, or CRAWL is desired, select the
    image to be displayed first from a series of images.
    3) Set the data playback format etc.
    1
    2
    3
    1 Set the data playback format.
    2 Set the data frame number (number of images).
    3 Set the frame number for the image to be
    displayed in the Icon row.
    
    When the selected image is not a series format, it will be
    registered automatically as STILL data, so this screen will
    not be displayed.
    4) The data is added to the transmission list and
    displayed in the main window.
    Setting the Title data playback properties
    Setting of special effects with DSK ON, DSK OFF, the data
    display position, etc. will be done automatically according to
    the initial value settings at the time the data was registered
    in the transmission list.
    These settings can be changed on the Properties screen of
    the data.  The properties screen of the data is opened using
    the following procedure.
    1) Move the mouse cursor to the data for which the
    settings are to be changed and left click on the data.
    The yellow band cursor will move and the data will be
    selected.
    2) Select “Property” from the “File” menu of the main
    window.
    The Properties window will open. 
    						
    							87
    Off: This is used for setting the operation to be
    performed when the data is deleted from the
    screen (DSK OFF).
    ≥AutoTrigger: This sets the start operation.
    No check: DSK OFF will be performed when the playback
    button on the main window is pressed or when
    the DSK button on the main unit is pressed.
    Check:DSK OFF will be performed according to the
    time set for Duration.
    ≥Effect: Same as for DSK ON.
    ≥Slide : Same as for DSK ON.
    Duration: This is used for setting the data playback time.
    The playback time also includes the time for
    DSK ON and DSK OFF.  This is effective only
    when AutoTrigger of DSK OUT is checked.
    Position: This is used for setting the data display position
    as the offset (pixels) from the left top of the
    screen.
    X and Y can be set for STILL and MOVIE, Y can
    be set for CRAWL, and X can be set for Roll.
    ≥X: A value from 0 to 719 can be set for NTSC
    as well as PAL.
    ≥Y: A value of 0 to 480 can be set for NTSC,
    and a value of 0 to 576 can be set for PAL
    (only even numbers).
    Protect:When this is checked, the data will not be
    cleared from the memory by normal clearing
    operation.
    Mark: Any number from 1 to 9 can be set.  When the
    number to be set is selected via “Cursor” >
    “Jump to Mark.”  it is possible to jump straight to
    the desired data.
    Name: This is used for setting the name of the data.  Up
    to 128 single-byte characters can be entered.
    Comment: This is used for setting a comment for the data.
    Up to 128 single-byte characters can be entered.
    
    ≥The initial value for the playback setting can be changed
    at the “Initial set of Property data” screen.  (Refer to page
    92.)
    ≥When the pattern entered for DSK ON and DSK OFF is a
    pattern that can not be used with DSK, automatic
    correction will be made to a similar pattern.
    ≥When there are 3000 or more patterns, the same pattern
    must be used for DSK ON and DSK OFF.
    For 0 to 2999 patterns, the combination of DSK ON and
    DSK OFF can be selected freely.
    ≥Set Time as 00:00 when no special effects are to be used
    with DSK ON and DSK OFF.
    ≥When 1 has been selected for DIVIDE with the CRAWL
    data, the Position Y value cannot be set.
    Title data operations
    Description of the setting items (depending on the data
    playback format, some items may not be displayed or
    setting may not be possible)
    Icon: This is used for setting the frame number of the
    image to be used for display in the ICON row of
    the main window.
    Mode:This is used for selecting ONCE or REPEAT
    when MOVIE display is being used.
    During ROLL and CRAWL, it is used for
    selecting the scroll direction and entering the
    speed (number of pixels to be moved per field).
    On: This is used for setting the operation when the
    data is displayed on the screen (DSK ON).
    ≥AutoTrigger: This sets the start operation.
    No check: DSK ON will be performed when the playback
    button on the main window is pressed or when
    the DSK button on the main unit is pressed.
    Check:DSK ON will be executed when the specified
    time has expired after the data playback
    operation.
    ≥Effect: This sets the special effects.
    Pattern: The specified pattern will be used at DSK ON.
    Diss: Dissolve will be used.
    Time:Set the time for execution of special effects
    from 00:00 to 00:30.
    ≥Slide: This is used for the slide display settings.
    Dir:Click the arrow to select the slide direction.
    When a setting other than 1 has been selected
    for DIVIDE, sliding in the vertical direction
    cannot be set.
    Speed: Enter the slide speed (number of pixels to be
    moved per field). 
    						
    							88
    Automatic transmission and playback of Title data
    The data from the cursor position to the end of the
    transmission list can be transmitted automatically and DSK
    playback can be performed automatically.
    Select “Operation” >“Autoload” from the menu of the main
    window.
    Manual transmission and playback of Title
    data
    Data registered in the transmission list can be transmitted to
    the AG-MX70 using the following procedure.
    1) Move the cursor to the data to be transmitted and left
    click on the data.
    The yellow frame cursor moves to the selected data.
    2) Select “Operation” >“Load title” from the menu of
    the main window.
    The data is transmitted to the AG-MX70.
    
    ≥The time required for the transmission differs according to
    the image size and the number of images.
    ≥Transmission is not possible when the image memory of
    the AG-MX70 does not have the required free space.
    Clear any data that is not required from the image
    memory (refer to “Clearing Title data”) and repeat the
    transmission operation.
    ≥Images cannot be transmitted while the “Loading...”
    display appears on the LCD screen immediately after the
    AG-MX70’s power has been turned on or immediately
    after changes have been made to the image memory
    settings.
    ≥While transmission is in progress, the LCD display of the
    AG-MX70 shuts down.
    DSK playback of the transmitted data is possible using the
    following procedure.
    1) Move the cursor to the data for DSK playback and left
    click on the data.
    The yellow frame cursor moves to the selected data.
    2) Select “Operation” >“Play” from the menu of the
    main window.
    DSK playback is performed for the data.
    
    In order to perform DSK playback for the data, it is
    necessary to set Key and Fill to Title using the DSK/Fade
    item on the DSK Fade menu of the AG-MX70.  For details,
    refer to page 46.
    Title data operations
    1
    2
    53
    4
    1 The DSK status is displayed here.
    2 The transmission status is displayed here.
    3 This executes DSK ON/OFF.
    4 This stops automatic loading.
    5 When a check is entered, a return is made to the
    initial data and playback continues after the last
    data on the transmission list has been played
    back.
    
    ≥Any data that has not been transmitted will be transmitted
    automatically.  Transmission also will be executed during
    playback of other data.
    ≥If the data transmission has not been completed by the
    time the DSK playback stage is reached, standby status
    will be maintained until it is completed.
    ≥After DSK playback, data without the Protect setting will
    be cleared from the memory.
    Clearing Title data
    The data written to the image memory of the AG-MX70 will
    be cleared only by a clearing operation or when the power
    supply of the AG-MX70 is switched off.  When space is
    required for transmission of new data, delete any data that
    is not required.  The clearing operation is performed using
    the following procedure.
    1) Move the cursor to the data to be cleared and left
    click on the data.
    The yellow frame cursor moves to the selected data.
    2) Select “Operation” >“Clear the selected title” from
    the menu of the main window.
    The data is cleared.
    
    ≥
    When “Operation” >“Clear all title” is selected from the menu
    of the main window, all transmitted Title data will be cleared.
    ≥Data for which Protect has been set will not be cleared by
    this operation.  Clearing of data for which Protect has
    been set must be done from the memory status screen.
    (Refer to page 90.) 
    						
    							89
    Reordering the transmission list
    The transmission list can be reordered by any one of the
    following methods.
    ≥Select the reordering method as “Sort by name” or
    “Sort by comments” from the “Display” menu.
    ≥Double-click the  ,  buttons in the heading column
    of NAME/COMMENT of the transmission list.  When
    the display mode is Icon mode, reordering by name will
    be done with the left button and reordering by comment
    with the right button.  When the display mode is List
    mode, it is only possible to reorder by name.
    ≥Data can be dragged to a different position by left-
    clicking on the data and releasing the button after
    dragging the cursor to a new position.  The data will be
    moved to the position where the button was released.
    Saving the transmission list
    The created transmission list can be saved to a file.
    1) Select “Save list as...” from the “File” menu of the
    main window.
    The “Save List as...” dialog will be displayed.
    2) Enter the list name and click on the “Save” button.
    Opening a transmission list
    A saved transmission list can be opened as follows.
    1) Select “Open list” from the “File” menu of the main
    window.
    The “Open file” dialog will be displayed.
    2) Select the list to be opened and click on the “Open”
    button.
    Deleting Title data from the transmission list
    Data registered in the transmission list can be deleted from
    the list using the following procedure.
    1) Move the cursor to the data to be deleted and left-
    click on the data.
    The yellow frame cursor moves to the selected data.
    2) Select “Edit” >“Delete” from the menu of the main
    window.
    The data is deleted from the transmission list.
    1
    Title data operations
    Checking the Title data image
    The image of the data selected on the image display screen
    can be displayed in the original size so it can be checked.
    The image display screen can be displayed using one of the
    following methods.
    ≥Select “Preview” from the file menu of the main
    window.
    ≥Select “Preview” from the menu displayed when the
    mouse is right-clicked on the data.
    ≥Double-click the ICON part in the data display column.
    When the selected data has been changed on the main
    window, the image changes to reflect the changes.
    1Order
    This is the order of the data to which the displayed
    image belongs.  The order displayed data can be
    changed either by direct input of numbers or by
    clicking the arrows.
    2Frame
    This shows the data frame to which the displayed
    image corresponds.  The displayed frame can be
    changed either by direct input of numbers or by
    clicking the arrows.
    2 
    						
    							90
    Checking the memory status of the AG-MX70
    The status of the image memory of the AG-MX70 can be
    checked on the memory status screen.
    Select “Tools” >“Memory status” from the menu of the
    main window to open the memory status screen.
    Other operations
    1
    2
    1The system setting status of the AG-MX70 is
    displayed here.
    2This is the memory status display column.
    ≥One line corresponds to one page.
    ≥The column with the line numbers displayed in
    yellow is the Title data area, and the blue column
    shows the range of the IntVideo data.
    ≥With Title data, the color differs according to the
    data type.
    Orange: Normal data
    Pink: Data with Protect setting
    Green: Data that cannot be recognized by MX-Navi
    (data written on the AG-MX70 side, data transmitted the
    previous time when MX-Navi had been started, etc.)
    ≥The data can be selected by left-clicking on the data
    in the status display column.  The selected data
    becomes the object for clearing and for reading to
    the PC.
    
    ≥On this screen, select the data to be cleared and then
    select “Operation” >“Clear specified area ” from the
    menu.  Title data with Protect setting also will be cleared
    by this operation.
    ≥All Title IntVideo data can be cleared by selecting
    “Operation” >“All Clear” from the menu of this screen.
    Changing the AG-MX-70 memory settings
    The settings of the AG-MX70 (switching between NTSC and
    PAL, switching between 4:3 and 16:9, changing the page
    distribution between Title data and IntVideo data) can be
    changed from the PC.
    1) From the menu of the main window, select “Tools” >
    “AG-MX70 setup” to open the mixer setting screen.
    2) Change the memory settings in the Memory column
    on the mixer setting screen.
    Signal This setting can be switched between NTSC
    and PAL.
    AspectThis setting can be switched between 4:3
    and 16:9.
    Allocation The page distribution between Title data and
    IntVideo data can be changed here.
    3) The settings are reflected by clicking the “Set” button.
    
    ≥When the memory setting has been switched to 4:3 or
    when the page distribution for Title data and IntVideo data
    has been changed, all data will be cleared from the image
    memory.
    ≥When the memory setting has been switched from NTSC
    to PAL or vice versa, the current transmission list will be
    closed and a new list will be opened. 
    						
    All Panasonic manuals Comments (0)