    Have a look at the manual Panasonic High Speed Color Scanner Kv S5055c Operating Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Inside of the Scanner
    Note•Clean the scanner at least once a week or when 20,000 sheets have been scanned, whichever comes
    first.
    • Clean the rollers and sensors if paper jamming or double feeding occurs frequently.
    • If double feed detection does not function properly, clean the double feed detectors.
    • Clean the scanning glass when black or white lines appear on the scanned images.
    • If the documents you are scanning are dirty, then the scanner parts will also become dirty. To maintain
    proper scanning, clean the scanner parts frequently.
    About the roller cleaning paper Open the roller cleaning paper on the dotted line ( A), and take out the roller cleaning paper.
    Notice
    •Keep the roller cleaning paper out of reach of small children.
    • Do not store the roller cleaning paper in direct sunlight or in a place with temperature over 40 
    (104 ).
    • Only use the roller cleaning paper to clean the rollers and scanning glass.
    • For details about the roller cleaning paper, please refer to the Material Safety Data Sheet (MSDS).
    Please ask your Panasonic sales company about obtaining the Material Safety Data Sheet.
    Note
    •If the bag is left opened for a long period of time before using it, the alcohol will evaporate.
    Please use the roller cleaning paper immediately after opening the bag.
    • The roller cleaning paper (KV-SS03) is available from the dealer where you purchased the scanner.
    For supplies and accessories:
    Call 1-800-726-2797 (U.S.A. only) or your dealer.
    Operating Manual51Care and Maintenance1 °C °F  
    						
    							How to use the blowerRemove the brush tip from the blower ( A), place it on the area that you want to clean ( B), and then blow away
    any dirt, as shown in the following figure.
    • If dirt has accumulated, first remove the dirt with the brush tip of the blower, and then remove the brush tip
    and blow away the remaining dirt.52Operating ManualCare and Maintenance  
    						
    							Cleaning the Conveyor
    CAUTION•The scanning glass may be very hot after scanning a lot of documents.
    Clean the scanning glass after the temperature has cooled.
    Note
    •Clean the conveyor before cleaning the rollers.
    1. Set the power switch of the scanner to "
    " (OFF).
    2. Pull the ADF door release ( A) towards you, and open the ADF door ( B).
    3. With a dry cloth, wipe off any dirt on the conveyor ( A).
    Operating Manual53Care and Maintenance 12 1  
    						
    							4.With the included blower, blow away any dirt that has accumulated on the self-cleaning brushes ( A).
    • Rotate the reference plates ( B, C ) in the direction indicated by the arrow so that you can see the
    brush.
    • After cleaning, rotate the reference plates ( B, C ) in the directions indicated by the arrows to return
    the plates to the original background color.
    Notice
    •After cleaning, make sure that the 
     mark on the outside of the reference plate and the  mark
    on the reference plate are aligned (page 44).
    If the marks are not aligned, the background color will not be correct.
    54Operating ManualCare and Maintenance1
    3
    2    
    						
    							5.With the included blower, blow away any dirt that has accumulated on the ion outlets ( A).
    Notice
    •When cleaning the ion outlets, be sure to remove the brush tip from the blower. Using the blower
    with the brush tip still on might damage the ionizer.
    6. Close the ADF door.
    • Push both sides of the ADF door down slowly until it clicks into place.
    7.Set the power switch of the scanner to "" (ON).
    Operating Manual55Care and Maintenance1    
    						
    							Cleaning the Rollers
    CAUTION•The scanning glass may be very hot after scanning a lot of documents.
    Clean the scanning glass after the temperature has cooled.
    1. Set the power switch of the scanner to "
    " (OFF).
    2. Pull the ADF door release ( A) towards you, and open the ADF door ( B).
    56Operating ManualCare and Maintenance 12  
    						
    							3.Use the roller cleaning paper (page 51) to remove the dirt from the surfaces of all rollers.
    Direction to wipe rollersDouble feed prevention roller, Separation rollerOther rollers
    Notice •After removing the double feed prevention roller, gently wipe dirt from the surface of the roller in
    the direction indicated by the arrows in the illustration. If you wipe too hard, you may damage or
    misalign the roller.
    For instructions on how to remove the double feed prevention roller, see "Replacing the Double
    Feed Prevention Roller" (page 69).
    • Wipe dirt off of the other rollers in the directions indicated by the arrows in the illustration. Use your
    finger to rotate the roller and wipe dirt off of the entire surface of the roller. If the roller rotates when
    wiping it, gently hold it in place with your finger.
    Operating Manual57Care and Maintenance   
    						
    							Location of RollersAPaper feed rollerBSeparation rollerCFree rollersDDouble feed prevention rollerEDrive rollers58Operating ManualCare and Maintenance3
    4
    12 5  
    						
    							4.Close the ADF door.
    • Push both sides of the ADF door down slowly until it clicks into place.
    5.Set the power switch of the scanner to "" (ON).
    6. Reset the roller cleaning counter in User Utility to 0.
    • Start User Utility, and in the window, click the [Clear Counter] button for "After Clean Roller" to reset
    to counter to 0.
    • For details, refer to the help for User Utility.
    Operating Manual59Care and Maintenance   
    						
    							Cleaning the Sensors and Scanning Glass
    CAUTION•The scanning glass may be very hot after scanning a lot of documents.
    Clean the scanning glass after the temperature has cooled.
    1. Set the power switch of the scanner to "
    " (OFF).
    2. Pull the ADF door release ( A) towards you, and open the ADF door ( B).
    60Operating ManualCare and Maintenance 12  
    						