    							-19-
    eSet G/L PHASE ON/OFF Switch of the multi hybrid con-
    trol panel back to the OFF position.
    ·Subcarrier Phase Adjustment
    qSet G/L PHASE ON/OFF Switch (15) of the multi hybrid
    control panel to the ON position.
    Note:When G/L PHASE ON/OFF Switch of the multi
    hybrid control panel is set to the ON position, the
    sync phase of the camera changes to the settings
    of G/L PHASE H Control, G/L PHASE Coarse
    Switch, and G/L PHASE SC Control.  Unless G/L
    phase adjustment is necessary, do not set G/L
    PHASE ON/OFF Switch to the ON position.
    wAdjust G/L PHASE Coarse Switch and G/L PHASE SC
    Control to match the subcarrier color phase of the
    video signal output with that of the reference tone,
    such as of the program output (split color bar output)
    of a Color Special Effect Generator, for example.
    Higher accuracy can be obtained if a vectorscope is
    used for color phase adjustment.ON SC H
    OFF
    G/L PHASE
    90° 180°
    0°      270°
    External genlock
    input signal
    (black burst sig-
    nal)
    Video signal
    G/L PHASE H Control
    eSet G/L PHASE ON/OFF Switch of the multi hybrid con-
    trol panel back to the OFF position.
    Magenta Green
    Cyan
    Yellow
    White
    Red
    Blue
    Black
    ON SC H
    OFF
    G/L PHASE
    90° 180°
    0°      270°
    G/L PHASE ON/OFF Switch
    G/L PHASE Coarse Switch
    G/L PHASE SC Control
    Color bar of
    camera
    Color bar of
    special Effects
    generator Split line
    G/L PHASE
    ON/OFF Switch 
    						
    							-20-
    •Total Pedestal AdjustmentTotal pedestal adjustment is made to adjust the
    pedestals of two or more cameras.  Using an oscillo-
    scope or a waveform monitor, adjust the pedestals to 5
    IRE (0.035 V) or 7.5 IRE (0.050 V) with T.PED Control of
    the multi hybrid control panel.
    T.PED
    CABLE COMP
    YC
    T. PED Control
    5 IRE (0.035V) or
    7.5 IRE (0.050V)
    3) Set the switches for gain, shutter, etc. as appropriate
    to the conditions of using the camera.
    4) Set the camera control switch on the multi hybrid con-
    trol panel to the OFF position.
    5) Repeat Steps 1 to 4 to finish cable compensation, G/L
    adjustment, total pedestal adjustment, and switch set-
    ting for all the cameras.
    4. White Balance and Black Balance
    Setting1) Select a camera with the CONTROL switch on the multi
    hybrid control panel.
    2) Select a camera with the CONTROL switch on the multi
    hybrid control panel.
    • White balance adjustment is necessary when using the
    camera for the first time, or if the camera has not been
    used for a long period of time.
    • Once the white balance is adjusted, no readjustment is
    necessary if the camera is used under the same condi-
    tions.• Automatic White Balance Control (AWC)The color temperature conditions for two channels A
    and B can be stored in the memory in advance.  Once
    the white balance is adjusted, all that is needed is to
    select either AUTO/ATW A Switch or AUTO/ATW B
    Switch of the multi hybrid control panel. if the camera is
    used under the same conditions.  No readjustment is
    necessary.  If the white balance is readjusted, the exist-
    ing white balance data is replaced with new data.
    qPress either AUTO/ATW A Switch or AUTO/ATW B
    switch of the multi hybrid control panel. 
    						
    							-21-
    wPick up a white object (a white wall or white handker-
    chief, for example) fully on the screen.  Be careful to
    keep a shiny or bright object out of the screen.
    eWhen AWC Switch of the multi hybrid control panel is
    pressed, the auto Auto set Indicator flashes and the
    white balance is automatically adjusted.  It goes out
    when it has been properly adjusted.  If the adjustment
    fails, Auto set Indicator remains lit.  In such a case,
    change the brightness, iris, object, light source, etc.
    and adjust it again.
    • Automatic Tracing White Balance Control (ATW)
    When AUTO/ATW-ATW Switch of the multi hybrid con-
    trol panel is pressed, the white balance is automatical-
    ly adjusted even if the light source or color tempera-
    ture changes, thus reproducing a natural image.
    Note:The white balance may deviate if there is noth-
    ing white in the image.  The white balance may not
    be fully adjusted depending on the light source or
    color temperature.
    • Black balance adjustment is necessary when using the
    camera for the first time, or if the camera has not been
    used for a long period of time.
    • Black balance adjustment is necessary if there is a big
    change in the ambient temperature or at the turn of a
    season. 
    • Once the black balance is adjusted, no readjustment
    is necessary if the camera is used under the same
    conditions.• Automatic Black Balance Control (ABC)
    When ABC Switch of the multi hybrid control panel  is
    pressed, the lens iris is automatically closed to set the
    black balance.  Keep IRIS AUTO/MANU Switch of the
    multi hybrid control panel in the AUTO position when
    setting the black balance.  The auto set LED flashes
    during black balance adjustment, and goes out when it
    is finished normally.  The LED remains lit if the adjust-
    ment fails.  In such a such, try to adjust it again.
    Black balance adjustment may fail in some cases
    where the total pedestal is too low.  Adjust the total
    pedestal with T.PED Control of the multi hybrid control
    panel and adjust the black balance again.
    3) Repeat Steps 1) and 2) to adjust the white blance and
    black balance of all cameras. 
    						
    							-22-
    5. Camera and Pan/tilt Head Presetting1) Select a camera and pan/tilt head with the CONTROL
    switch on the multi hybrid control panel.
    2) Pick up a desired object with the camera using
    PAN/TILT Lever ZOOM Lever and FOCUS Lever of the
    multi hybrid control panel. Select a white balance con-
    trol mode using AUTO/ATW ATW Switch AUTO/ATW A
    Switch or AUTO/ATW B Switch.  To store iris data in the
    memory, set IRIS AUTO/MANU Switch to the MANU
    position and turn the iris control.  When IRIS
    AUTO/MANU Switch is in the AUTO position, iris data
    will not be stored in the memory.
    3) Keep MEMORY Switch of the multi hybrid control panel
    depressed (MEMORY Switch lights and all the 10 but-
    tons of PRESET Switch flash), press any of the buttons
    [1] to [10] of PRESET Switch as desired to store the
    data in the memory.  Only that button of PRESET
    Switches where the data is stored lights.
    Note:If data is stored again in the same button of
    PRESET Switches of the multi hybrid control
    panel the preceding data is deleted.
    4) Repeat Steps qand eto store the presettings of all
    the cameras and pan/tilt heads in the memory.
    6. Various Switch SettingsSelect a desired operating camera and pan/tilt head with
    the CONTROL switch on the multi hybrid control panel,
    then control the camera and pan/tilt headControl the cam-
    era and pan/tilt head using PRESET Switch, PAN/TILT
    Lever, ZOOM Lever, FOCUS Lever, IRIS AUTO/MANU
    Switch and other switches.
    * In case of not changing the adjustment data and set-
    tings, it is not necessary to repeat the adjustment and
    setting procedures described in Sections 2 to 5. 
    						
    							1
    YC2
    YC3
    YC4
    YC5
    YC
    CABLE  COMP1
    YC2
    YC3
    YC4
    YC5
    YC
    CABLE  COMP
    1
    YC2
    YC3
    YC4
    YC5
    YC
    CABLE  COMP
    -23-
    RACK MOUNTINGTo mount the multiport hub in a rack, use the supplied rack
    mounting brackets and screws (M4x10).
    qPress the power switch to turn power off.
    wRemove the 4 feet.
    eWith the rack mounting brackets on both ends of the
    multiport hub, fasten them with the supplied screws (4
    pcs.)
    rMount the multiport hub in the rack and fasten it with
    the rack mounting screws (4 pcs.)
    Notes:
    • The rack mounting screws are optional. (Optional)
    • Keep the multiport hub away (at least its size) from
    other devices, or mount a cooling fan in the rack,
    so that the temperature inside the rack will not rise
    above 50°C.
    Rack mounting bracket
    Rack mounting screws (Optiona) Mounting
    screws
    Remove them
    Power switch 
    						
    							-24-
    SPECIFICATIONSSource Voltage 12 V DC (4-pin cannon connector)
    Power Consumption 12V, 2A
    Video Input 1.0 V[p-p] composite/75½x 5 (BNC connector)
    Genlock Input 1.0 V[p-p] black burst/75½(BNC connector)
    Camera Control Intput Control signal (BNC connector)
    Pan/tilt Control Intput Control signal (RJ-45 8P modular jack)
    Video Output 1.0 V[p-p] composite/75½x 5 (BNC connector)
    S-video Output Y: 0.714 V[p-p] (75 ½)
    C: 0.286 V[p-p] burst level chrominance/75½x 5 (S-VIDEO connector)
    Preview Video Output 1.0 V[p-p] composite/75½(BNC connector)
    Genlock Output 75½x 5 (BNC connector)
    Camera Control Output Control signal x 5 (BNC connector)
    Pan/tilt Control Output Control signal x 5 (RJ-45 8P modular jack)
    Switches Power ON/OFF Switch
    Controls CABLE COMP Y Control, CABLE COMP C Control
    Pan/tilt Head Connecting Cable: x 4 (Coaxial Cable 3 pcs., 10BASE-T straight cable 1 pc.)
    (In case of using G/L function)
    Control Panel Connecting Cable: pan/tilt head x 4  (Coaxial Cable: 3 pcs., 10BASE-T straight cable: 1 pc.)
    (In case of using G/L function)
    Maximum cable length: Control panel connecting cable :10 m (In case of using coaxial cables 5C-2V and
    10BASE-T cable UTP category-5)
    Pan/tilt head connecting cable :500 m (In case of using coaxial cables 5C-2V and
    10BASE-T cable UTP category-5) 
    						
    							-25-
    Operating temperature-10°C to +45°C (14°F to +113°F)
    Dimensions 420 (W) x 88 (H) x 250 (D) mm [16-9/16 (W) x 3-7/16 (H) x9-13/16” (D)]
    Weight 4 kg(8.8 lbs.)
    Finish Cover: AV Ivory vinyl chloride steel
    Panel: AV Ivory painting
    Weight and dimensions indicated are approximate.
    Specifications are subject to change without notice.ACCESSORIESRack mounting part ................................ 2
    Mounting screws .................................... 4 
    						
    							N1197-0 7J1A108A Printed in Japan
    Broadcast & Television Systems Company
    Division of Matsushita Electric Corporation of AmericaExecutive Office:One Panasonic Way 2E-6, Secaucus, NJ 07094
    Regional Offices:
    EASTERN ZONE:43 Hartz Way, Secaucus, NJ 07094 (201) 348-7620
    CENTRAL ZONE:1707 North Randall Road, Elgin, IL 60123 (847) 468-5200
    SOUTHERN ZONE:
    Atlanta Region:1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30174
    Panazip 11 (770) 338-6841, fax (770) 338-6741
    Law Enforcement Video Products:1225 Northbrook Parkway, Suite 1-160, Suwanee, GA
    30174, Panazip 11 (770) 338-6844, fax (770) 338-6721
    WESTERN ZONE:
    Los Angeles Region:6550 Katella Ave. 17A-1, Cypress, CA 90630 (714) 373-7271
    Government Marketing Department:52 West Gude Drive, Rockville, MD 20850 (301) 738-3840PANASONIC CANADA INC.5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905) 624-5010PANASONIC SALES COMPANY
    DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC.San Gabriel Industrial Park, 65th Infantry Ave. KM. 9.5 Carolina, Puerto Rico 00630 (809) 750-4300 
    						
    All Panasonic manuals Comments (0)