    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 171
    [Adjust clock] page
    Click [Detailed set up] → [Adjust clock].
    1
    2
    3
    4
    5
    6
    7
    1 [Time Zone]
    Select the time zone.
    2
     
    [Set time zone]
    Updates the time zone setting.
    3
    
     
    [NTP
      SYNCHRONIZATION]
    Set to [ON] to adjust the date and time automatically.
    4
     
    [NTP
      SERVER NAME]
    Enter the IP address or server name of the NTP server when 
    you set to adjust the date and time manually.
    (To enter the server name, the DNS server needs to be set up.) 5
     [Date]
    Enter the date to be changed.
    6
     
    [T
     ime]
    Enter the time to be changed.
    7
     
    [Submit]
    Updates the date and time settings.
    Note
     fThe replacement of the battery inside the projector is required when the time goes out of alignment right after correcting the time. Consult 
    your dealer
    .
    [Ping test] page
    Check whether the network is connected to the E-mail server, POP server, DNS server, etc.
    Click [Detailed set up]  → [Ping test].
    1
    2 3
    4
    1 [Input IP  address]
    Enter the IP address of the server to be tested.
    2
     
    [Submit]
    Executes the connection test. 3
    
     Example of display when the connection has succeeded
    4  
    Example of display when the connection has failed  
    						
    							Chapter 4 Settings — [NETWORK] menu
    172 - ENGLISH
    [E-mail set up] page
    Send an E-mail to preset E-mail addresses (up to two addresses) when a problem has occurred.
    Click [Detailed set up] → [E-mail set up].
    1
    2
    3
    4
    5
    6
    1 [ENABLE]
    Select [Enable] to use the E-mail function.
    2
     
    [SMTP
      SERVER NAME]
    Enter the IP address or the server name of the E-mail server 
    (SMTP). To enter the server name, the DNS server needs to be 
    set up.
    3
     
    [MAIL
      FROM]
    Enter the E-mail address of the projector. (Up to 63 characters 
    in single byte)
    4
     
    [MEMO]
    Enter information such as the location of the projector that 
    notifies the sender of the E-mail. (Up to 63 characters in single 
    byte) 5
    
     [MINIMUM TIME]
    Change the minimum interval for the temperature warning 
    E-mail. 
    The default value is 60 minutes. In this case, another 
    E-mail will not be sent for 60 minutes after sending the 
    temperature warning E-mail even if it reaches the warning 
    temperature.
    6
     
    [INT
     AKE AIR TEMPERATURE]
    Change the temperature setting for the temperature warning 
    mail. A temperature warning E-mail is sent when the 
    temperature exceeds this value.  
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 173
    8
    7
    9
    8
    7
    7 [E-MAIL ADDRESS 1], [E-MAIL ADDRESS 2]
    Enter the E-mail address to be sent. Leave [E-MAIL ADDRESS 
    2] blank when two E-mail addresses are not to be used. 8
     Settings of the conditions to send E-mail
    Select the conditions to send E-mail.
    [MAIL
     CONTENTS]: 
    Select either [NORMAL] or [SIMPLE].
    [ERROR]: 
    Send an E-mail when an error occurred in the self-diagnosis.
    [INTAKE AIR TEMPERATURE]: 
    Send an E-mail when the intake air temperature has reached 
    the value set at the above field.
    [PERIODIC REPORT]: 
    Place a check mark on this to send an E-mail periodically.
    It will be sent on the days and time with the check mark.
    9
     
    [Submit]
    Update the settings.  
    						
    							Chapter 4 Settings — [NETWORK] menu
    174 - ENGLISH
    [Authentication set up] page
    Set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail.
    Click [Detailed set up] → [Authentication set up].
    1
    2
    3
    4
    5
    6
    7
    8
    1 [Auth]
    Select the authentication method specified by your Internet 
    service provider
    .
    2
     
    [SMTP
      Auth]
    Set when the SMTP authentication is selected.
    3
     
    [POP
      server name]
    Enter the POP server name.
    Allowed characters:
    Alphanumerics (A - Z, a - z, 0 - 9)
    Minus sign (-) and period (.)
    4
     
    [User name]
    Enter the user name for the POP
    
     server or the SMTP server. 5
     [Password]
    Enter the password for the POP
     server or the SMTP server.
    6
     
    [SMTP
      server port]
    Enter the port number of the SMTP server.
    (Normally 25)
    7
     
    [POP
      server port]
    Enter the port number of the POP server.
    (Normally 110)
    8
     
    [Submit]
    Update the settings.  
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 175
    Contents of E-mail sent
    Example of the E-mail sent when E-mail is set
    The following E-mail is sent when the E-mail settings have been establis\
    hed.
    === P anas onic  pr ojec t or  r epor t ( CO NF I G URE )  ===
    P r ojec t or  T y pe  :  RZ 12K
    S er ial No  :  123456789012
    -----  E-mail set up dat a -----
    T EMPERAT URE WARNING  SET UP 
    MINIMUM TIME  at  [  60]  m inut es  int er v al 
    I NT A K E  A I R T E M P E RA T URE   O v er  [  46 degC /  114 degF  ]  
    E RRO R  [ OFF ] 
    INT AKE AIR T EMPERAT URE  [ O F F  ]
    P E RI O DI C RE P O RT  
    S unday   [  O N  ]   M onday   [  O N  ]   T ues day   [  O N  ]   Wednes day   [  O N  ]  
    T hur s day   [  O N  ]   F r iday   [  O N  ]   S at ur day   [  O N  ]  
    00: 00  [  O N  ]     01: 00  [  O N  ]     02: 00  [  O N  ]     03: 00  [  O N  ]  
    04: 00  [  O N  ]     05: 00  [  O N  ]     06: 00  [  O N  ]     07: 00  [  O N  ]  
    08: 00  [  O N  ]     09: 00  [  O N  ]     10: 00  [  O N  ]     11: 00  [  O N  ]  
    12: 00  [  O N  ]     13: 00  [  O N  ]     14: 00  [  O N  ]     15: 00  [  O N  ]  
    16: 00  [  O N  ]     17: 00  [  O N  ]     18: 00  [  O N  ]     19: 00  [  O N  ]  
    20: 00  [  O N  ]     21: 00  [  O N  ]     22: 00  [  O N  ]     23: 00  [  O N  ]  
    -----  check syst em -----
    M A I N CP U B US   [   O K   ]
    F A N  [   O K   ]
    INT AKE AIR T EMPERAT URE  [   O K   ]
    O PT ICS MO DULE T EMPERAT URE  [   O K   ]
    EXHAUST  AIR T EMPERAT URE  [   O K   ]
    LD1 T EMPERAT URE  [   O K   ]
    LD2 T EMPERAT URE  [   O K   ]
    LD1 ST AT US  [   O K   ]
    LD2 ST AT US  [   O K   ]
    S HUT T E R(M UT E -S HUT T E R)  [    O K    ]
    INT AKE AIR T EMP.SENSO R  [   O K   ]
    F I LT E R UNI T   [   O K   ]
    A I R F I LT E R  [   O K   ]
    AC VO LT AG E   [   O K   ]
    ( E r r or  c ode 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
    I nt ak e air  t em per at ur e  :  30 degC /   86 degF
    O pt ic s  m odule t em per at ur e  :  39 degC /  102 degF
    E x haus t  air  t em per at ur e  :  32 degC /   89 degF
    A r ound light 1 t em per at ur e  :  34 degC /   93 degF
    A r ound light 2 t em per at ur e  :  34 degC /   93 degF
    P RO JE CT O R RUNT I M E      77 H
    P O WE R O N  1906 t im es
    LD1- 1 O N  1906 t im es
    LD1-1 RUNT I M E      76 H
    LD1- 2 O N  1906 t im es
    LD1-2 RUNT I M E      76 H
    LD1- 3 O N  1906 t im es
    LD1-3 RUNT I M E      76 H
    LD1- 4 O N  1906 t im es
    LD1-4 RUNT I M E      76 H
    LD1- 5 O N  1906 t im es
    LD1-5 RUNT I M E      76 H
    LD1- 6 O N  1906 t im es
    LD1-6 RUNT I M E      76 H
    LD2- 1 O N  1900 t im es
    LD2-1 RUNT I M E      75 H
    LD2- 2 O N  1900 t im es
    LD2-2 RUNT I M E      75 H
    LD2- 3 O N  1900 t im es
    LD2-3 RUNT I M E      75 H
    LD2- 4 O N  1900 t im es
    LD2-4 RUNT I M E      75 H
    LD2- 5 O N  1900 t im es
    LD2-5 RUNT I M E      75 H
    LD2- 6 O N  1900 t im es
    LD2-6 RUNT I M E      75 H
    -------- Current  st at us ---------
    MAIN VERSIO N  0. 24 
    SUB VERSIO N  0. 04. 01 
    LD S T A T US
    LD1- 1=O N LD1- 2=O N LD1- 3=O N LD1- 4=O F F  LD1- 5=O F F  LD1- 6=O N 
    LD2- 1=O N LD2- 2=O N LD2- 3=O N LD2- 4=O F F  LD2- 5=O F F  LD2- 6=O F F
    I NP UT   S DI 1
    SIG NAL NAME  ---
    S I G NA L F RE Q UE NCY   ---kHz /  ---Hz
    REMO T E2 ST AT US  DISABLE 
    ----- Wired Net work conf igurat ion -----
    DHCP  Client   O F F  
    I P  addr es s   192. 168. 0. 8
    M A C addr es s   12: 34: 56: 78: 90: 12
    M on J an 01 12: 34: 56 20X X
    ----- Memo -----  
    						
    							Chapter 4 Settings — [NETWORK] menu
    176 - ENGLISH
    Example of the E-mail sent for an error
    The following E-mail is sent when an error has occurred.
    === P anas onic  pr ojec t or  r epor t ( E RRO R)  ===
    P r ojec t or  T y pe  :  RZ 12K
    S er ial No  :  123456789012
    -----  check syst em -----
    M A I N CP U B US   [ F AILED ]
    F A N  [   O K   ]
    INT AKE AIR T EMPERAT URE  [   O K   ]
    O PT ICS MO DULE T EMPERAT URE  [   O K   ]
    EXHAUST  AIR T EMPERAT URE  [   O K   ]
    LD1 T EMPERAT URE  [   O K   ]
    LD2 T EMPERAT URE  [   O K   ]
    LD1 ST AT US  [   O K   ]
    LD2 ST AT US  [   O K   ]
    S HUT T E R(M UT E -S HUT T E R)  [    O K    ]
    INT AKE AIR T EMP.SENSO R  [   O K   ]
    O PT ICS MO DULE T EMP.SENSO R  [   O K   ]
    EXHAUST  AIR T EMP.SENSO R  [   O K   ]
    LD1 T EMP.SENSO R  [   O K   ]
    LD2 T EMP.SENSO R  [   O K   ]
    P O WE R CI RCUI T  T E M P E RA T URE   [    O K    ]
    F PG A T EMPERAT URE  [   O K   ]
    BAT T ERY  [   O K   ]
    LE NS  M O UNT E R  [   O K   ]
    BRIG HT NESS SENSO R  [   O K   ]
    PHO SPHO R WHEEL1  [   O K   ]
    PHO SPHO R WHEEL2  [   O K   ]
    F I LT E R UNI T   [   O K   ]
    A I R F I LT E R  [   O K   ]
    AC VO LT AG E  [   O K   ]
    ( E r r or  c ode 80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
    I nt ak e air  t em per at ur e  :  30 degC /   86 degF
    O pt ic s  m odule t em per at ur e  :  39 degC /  102 degF
    E x haus t  air  t em per at ur e  :  32 degC /   89 degF
    A r ound light 1 t em per at ur e :  34 degC /   93 degF
    A r ound light 2 t em per at ur e :  34 degC /   93 degF
    P RO JE CT O R RUNT I M E   77 H     
    P O WE R O N  1906 t im es
    LD1- 1 O N  1906 t im es
    LD1-1 RUNT I M E   76 H     
    LD1- 2 O N  1906 t im es
    LD1-2 RUNT I M E   76 H     
    LD1- 3 O N  1906 t im es
    LD1-3 RUNT I M E   76 H     
    LD1- 4 O N  1906 t im es
    LD1- 4 O N  1906 t im es
    LD1-4 RUNT I M E   76 H     
    LD1- 5 O N  1906 t im es
    LD1-5 RUNT I M E   76 H     
    LD1- 6 O N  1906 t im es
    LD1-6 RUNT I M E   76 H     
    LD2- 1 O N  1900 t im es
    LD2-1 RUNT I M E   75 H     
    LD2- 2 O N  1900 t im es
    LD2-2 RUNT I M E   75 H     
    LD2- 3 O N  1900 t im es
    LD2-3 RUNT I M E   75 H     
    LD2- 4 O N  1900 t im es
    LD2-4 RUNT I M E   75 H     
    LD2- 5 O N  1900 t im es
    LD2-5 RUNT I M E   75 H     
    LD2- 6 O N  1900 t im es
    LD2-6 RUNT I M E   75 H     
    -------- Current  st at us ---------
    MAIN VERSIO N  0. 24 
    SUB VERSIO N  0. 04. 01 
    LD S T A T US
    LD1- 1=O N LD1- 2=O N LD1- 3=O N LD1- 4=O F F  LD1- 5=O F F  LD1- 6=O N 
    LD2- 1=O N LD2- 2=O N LD2- 3=O N LD2- 4=O F F  LD2- 5=O F F  LD2- 6=O F F
    I NP UT   S DI 1
    SIG NAL NAME  ---
    S I G NA L F RE Q UE NCY   ---kHz /  ---Hz
    REMO T E2 ST AT US  DISABLE 
    ----- Wired Net work conf igurat ion -----
    DHCP  Client   OFF 
    I P  addr es s   192. 168. 0. 8
    M A C addr es s   12: 34: 56: 78: 90: 12
    M on J an 01 12: 34: 56 20X X
    ----- Memo -----  
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 177
    [Change password] page
    Click [Change password].
    1
    2
    3
    1 [Administrator]
    Used to change the setting of the [Administrator].
    2
     
    [User]
    Used to change the setting of the [User]. 3
    
     [Next]
    Used to change the setting of the password.
    [Administrator] account
    1
    3
    2
    4
    1 [Account]
    Displays the account to change.
    2
     
    [Current]
    [User name]: 
    Enter the user name before the change.
    [Password]: 
    Enter the current password. 3
    
     [New]
    [User name]: 
    Enter the desired new user name. (Up to 16 characters in single 
    byte)
    [Password]: 
    Enter the desired new password. (Up to 16 characters in single 
    byte)
    [Password(Retype)]: 
    Enter the desired new password again.
    4
     
    [OK]
    Determines the change of password.  
    						
    							Chapter 4 Settings — [NETWORK] menu
    178 - ENGLISH
    [User] account
    1
    2
    3
    1 [Account]
    Displays the account to change.
    2
     
    [New]
    [User name]: 
    Enter the desired new user name. (Up to 16 characters in single 
    byte)
    [Password]: 
    Enter the desired new password. (Up to 16 characters in single 
    byte)
    [Password(Retype)]: 
    Enter the desired new password again. 3
    
     [OK]
    Determines the change of password.
    [Change password] (For user rights)
    Only the change of password is enabled under the user rights.
    1
    2
    4 3
    1 [Old Password]
    Enter the current password.
    2
     
    [New Password]
    Enter the desired new password. (Up to 16 characters in single 
    byte) 3
    
     [Retype]
    Enter the desired new password again.
    4
     
    [OK]
    Determines the change of password.
    Note
     fTo change the account of the administrator, you must enter the [User name] and [Password] in [Current].
    [Crestron Connected(TM)] page
    The projector can be monitored/controlled with Crestron ConnectedTM.
    It is necessary to access with the administrator rights to start the ope\
    ration screen of Crestron Connected
    TM from 
    the web control screen. (The [Crestron Connected(TM)] button is not displayed in the web control screen with the 
    user rights.)
    The operation page of Crestron Connected
    TM is displayed by clicking [Crestron Connected(TM)].
    It is not displayed if Adobe Flash Player is not installed on your computer, or the browser you use does not 
    support Flash. In such a case, click [Back] in the operation page to go back to the previous page.  
    						
    							Chapter 4 Settings — [NETWORK] menu
    ENGLISH - 179
    Operation page
    1
    2
    3
    4
    5
    6
    7
    1 [Tools], [Info], [Help]Tabs for selecting the setting, information, or help page of the 
    projector.
    2
     
    [POWER]
    T
    
    urns on/off the power.
    3
     
    [SHUTTER]
    Switches whether to use the shutter function (enabled (shutter: 
    closed)/disabled (shutter: open)). 4
    
     [Input Select]
    Controls input selection.
    Not available when the power of the projector is turned of
    f.
    5
     
    Menu screen control buttons
    Navigates the menu screen.
    6
    
     
    Freeze/image quality adjustment
    Controls items related to freeze/image quality
    
    .
    7
     
    [Back]
    Returns to the previous page.
    [Tools] page
    Click [Tools] in the operation page.
    1
    2
    3
    4
    5
    1 [Control System]
    Set the information required for communicating with the 
    controller to be connected with the projector
    .
    2
     
    [User Password]
    Set the user rights password for the operation page of Crestron 
    Connected
    TM.
    3
     
    [Admin Password]
    Set the administrator rights password for the operation page of 
    Crestron Connected
    TM. 4  
    Network status
    Displays the settings of wired LAN.
    [DHCP]
    Displays the current setting.
    [Ip 
    
    Address]
    Displays the current setting.
    [Subnet Mask]
    Displays the current setting.
    [Default Gateway]
    Displays the current setting.
    [DNS Server]
    Displays the current setting.
    5
     
    [Exit]
    Returns to the operation page.  
    						
    							Chapter 4 Settings — [NETWORK] menu
    180 - ENGLISH
    [Info] page
    Click [Info] in the operation page.
    4
    5
    6
    1
    2
    3
    7
    1 [Projector Name]
    Displays the projector name.
    2
     
    [Mac Address]
    Displays the MAC address.
    3
    
     
    [Lamp1 Hours], [Lamp2 Hours]
    Displays the runtime of the light source 1 and the light source 2.
    4
    
     
    [Power Status]
    Displays the status of the power
    
    . 5
     [Source]
    Displays the selected input.
    6
     
    [Error Status]
    Displays the error status.
    7
    
     
    [Exit]
    Returns to the operation page.
    [Help] page
    Click [Help] in the operation page.
    The [Help Desk] window is displayed.
    1
    1 [Help Desk]
    A  message can be sent/received with the administrator using 
    the Crestron Connected
    TM.  
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Projector PT-RS11K User Manual