Have a look at the manual Panasonic Upgrade Utility For Audio Mixer WR-DA7 Version 2.0 Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

Users’ Guide Upgrade Utility for Audio Mixer WR-DA7 Version 2.0 The meter bridge shown in photo is one of the optional accessories. Before attempting to connect or operate this product, please read these instructions completely.

TRADEMARKS All trademarks are the property of their respective copyright holder for use in this document, including but not limited to; ProTools is a registered trademark of DigiDesign ADAT is a registered trademark of ALESIS Corp. CS-10 is a registered trade mark of JL Cooper Electronics Macintosh is a registered trademark of Apple Computer, Inc. Windows is either a trademark or a registered trademark of Microsoft Corporation Copyright 2000 Limit of Liability/Disclaimer of Warranty:The author, Audio Video Systems Division of Matsushita Communication Industrial Co., LTD and Professional Audio Division of Panasonic Broadcast and Digital Systems Company have used their best efforts in preparing this book. However, Audio/Video Systems Division of Matsushita Communication Industrial Co., LTD and Professional Audio Division of Panasonic Broadcast and Digital Systems Company make no representation or warranties with respect to the accuracy or completeness of the contents of this book and hereby specifically disclaims any implied warranties or merchantability or fitness for any particular purpose and shall in no event be liable for any loss of profit or any other commercial damage, including but not limited to special, incidental, consequential, or other damages. 2

Panasonic DA7 Upgrade Utility License Agreement Matsushita Communication Industrial Co., Ltd. (“MCI”) permits you to use the Panasonic DA7 Upgrade Utility software (“Software”) on condition of your acceptance of the following terms. As use of the Software shall be deemed that you have accepted the following terms, please read the following terms carefully before you use the Software. 1. Copyright and License for use MCI grants you an individual and a non-exclusive right to use the Software on only single computer. You own the magnetic media on which the Software is originally or subsequently recorded or fixed, but MCI retains title to and ownership in the Software. The Software and the accompanying documentation are copyrighted by MCI. 2. Prohibition and Restrictions You may not modify, adapt, translate, decompile, disassemble, reverse-engineer, or create derivative works based on the Software, nor may you allow another person to do so. The Software may not be duplicated, corrected, modified, lent, leased, sold, distributed, licensed or disposed of in any other way in part or in whole. The Software may not be transmitted over a network to another computer without written authorization from MCI. You may transfer the Software and accompanying documentation on a permanent basis to transferee provided it is for non-commercial purposes and you retain no copies and recipient agrees to the terms of this Agreement. 3. Limited Responsibility MCI shall not be liable for any direct, indirect, consequential, or incidental damages (including damages from but not limited to data loss, loss of business profit, business interruption, or loss of business information) arising out of the use of or inability to use the Software even, if MCI has been advised of the possibility of such damages. 3

5 The DA7 Upgrade Utility Users’ Guide Introduction Welcome to New Version 2.0 Operating System for the DA7. We hope you are enjoying your DA7, and that you will find that the 64 enhancements we have included in the Version 2.0 operating system will increase your enjoyment of our product. Please note that there are changes in the default settings of the DA7, some of which will affect how you operate your mixer. Please take a few moments to review the changes. This document covers ALL upgraded features to the original DA7 Operating System (Version 1.01/1.02). Therefore, we strongly recommend that you review this document before you upgrade your console so that you are familiar with all the new features. We also recommend that you print and keep this document as a supplement to the DA7 operation manual that came with your DA7. If you would like to have an electronic copy of the DA7 user guide, it can be downloaded from http://www.panasonic.com/proaudio. Once you have entered this site, go to the download section and select DA7 User Guide.

6 Important Notes: Due to the fact that there are many new default settings in the Version 2.0 upgrade, we are recommending that you do a Master Reset of the console after the upgrade. Therefore you should backup any settings in the Libraries, Scene Memories, Mixes, etc. BEFORE you begin the upgrade process. Instruction for this process can be found in Section 1. After the upgrade, make certain that you look at the MIDI REMOTE and INPUT MTX windows on the LCD to see if they are properly assigned. If they are not, please reset them to your desired settings or, do a master reset to the console to return the DA7 to the new factory default settings. There are several updates to the default settings that may have an affect on the settings in your console. This will protect you from accidental erasure of any of your presets. After the upgrade, simply restore the data you have saved following the instructions in Section 1. If you are planning to use our optional automation software package (MAX), please be aware that you must be running at least O.S. Version 1.10 for it to operate properly, and we recommend that you upgrade your DA7 to Version 2.0 for optimum performance. Some of the features documented here are from intermediate upgrade versions. If you are upgrading your console from Version 1.01 or 1.02, all of the features in this document will apply to you. If you have previously upgraded your console to Version 1.10-1.20-1.21 or 1.22, you have already been using some of the features documented here in Section 2. If you are upgrading from version 1.21 or 1.22, you should follow all the instructions in Section 1, and then you may proceed directly to Section 3. Contents: Section 1 - Upgrade Utility instructions Section 2 - Upgrade from Version 1.01/1.02/1.10/1.20 Section 3 - Upgrade from Version 1.21 or 1.22 Section 4 - APPENDIX - New Default Settings

1-1 Section 1 Upgrade Utility Instructions Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Cables and Connections . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Setting up the DA7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Operating the DA7 Upgrade Utility . . . . . . . . . . . . . . . . . 1-7 [SETUP] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 [VERSION] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 [BACKUP]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 [UPGRADE] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 [RESTORE] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 [EXIT] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19

1-2 Preface The DA7 Upgrade Utility is a multifunction software manager program specifically designed to allow you to perform operating system upgrades, as well as backup and restore functions for the library, scene memory, automation data, as well as setup data for the DA7. Using the serial ports on the DA7 and your computer, data can be sent to or from a DA7 and then saved to your computer hard disk for backup and retrieval. The memories and programs can be retrieved individually, or in groups. The retrieved memory and program titles can be edited using the computer’s keyboard. The data, including edited titles, can be transmitted between the computer and the DA7. Installation It is recommended that you perform a backup of your current data BEFORE you perform an upgrade to your DA7s operating system. Macintosh Version 1. Copy the files for installation file (DA7UPINS) to a folder on to your hard drive. 2. Once you have loaded the file, you need to open the folder to gain access to the following files: DA7UPG - Executable file of the Upgrade Utility V200R23.mot - Upgrade file for the DA7 CNV - Data Conversion folder for old backup versions BKUP - Backup Data folder 3. Open the file “DA7UPG”. 4. Test the communication path between the computer and your DA7 by clicking on the VERSION button on your computer in the open window. If it is properly connected, you will see the version of software that is currently in your DA7 displayed, and the “BACKUP” and “RESTORE” buttons will become active. (You need to set up DA7 and Upgrade Utility Configuration before test. To set up Configuration, read the following chapter “Cables and Connections”, “Setting up the DA7”, and “[Setup]” in “Operating the DA7 Upgrade Utility”.)

1-3 Windows Version 1. Copy the files for installation file (DA7UPINS.EXE) to folder on to your hard drive. 2. Double–click on “DA7IPINS.exe”, If you are unzipping the file, you can unzip it. The installation file installs the upgrade utility in “C:\UpgradeDA7”. 3.Once you have loaded the file, you need to open the folder to gain access to the following files: DA7UPG.exe - Executable file of the Upgrade Utility V200R23.mot - Upgrade file for the DA7 CNV - Data Conversion folder for old backup versions BKUP - Backup Data folder 4. Click on DA7UPG.exe to open the utility. 5. Test the communication path between the computer and your DA7 by clicking on the VERSION button on your computer in the open window. If it is properly connected, you will see the version of software that is currently in your DA7 displayed, and the BACKUP and RESTORE buttons will become active. (You need to set up DA7 and Upgrade Utility Configuration before test. To set up Configuration, read the following chapter “Cables and Connections”, “Setting up the DA7”, and “[Setup]” in “Operating the DA7 Upgrade Utility”.)

1-4 Cables and Connections For Macintosh Computer Use ONLY the recommended serial cable (cross cable) with a wiring pattern as described below. This cable is the same cable used for the ImageWriter II printer. Do NOT use a standard Macintosh Serial cable. Use this to connect between the modem port or printer port of the computer and the TO PC port of the DA7. For Windows/95 or PC compatible computer Use ONLY a serial cable with a wiring pattern as described below. This cable is available from Panasonic Pro Audio in the United States, part number DA/DB-DIN. Do NOT use a standard serial cable. Use this cable to connect between the serial port (COM1, COM2, COM3 or COM4) of your PC and the TO PC port of the DA7. When using a Windows computer, use the following cable: Pinout configuration of the cable. When building this cable, connect the pins in the following manner: DA7 port (Mini DIN 8p) pin # PC port (D-sub 9p) pin # 1 . . . . . .8 2 . . . . . .7 3 . . . . . .2 4 . . . . . .5 5 . . . . . .3 7 8 3 5 2 1 2 3 4 5Pin #Pin # 1 2 3 4 5 6 7 8 Frame 1 2 3 4 5 6 7 8 Frame Shield wire Pin #Pin # Mini DIN 8 (Male)DB9 (Female) Windows Computer TO PC of the DA7 Mini DIN 8 (Male) Mini DIN 8 (Male) TO PC of the DA7MODEM or Printer port of Mac Computer