Home > Panasonic > Music Mixer > Panasonic Upgrade Utility For Audio Mixer WR-DA7 Version 2.0 Users Guide

Panasonic Upgrade Utility For Audio Mixer WR-DA7 Version 2.0 Users Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Upgrade Utility For Audio Mixer WR-DA7 Version 2.0 Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Users’ Guide
    Upgrade Utility
    for Audio  Mixer
    WR-DA7
    Version 2.0
    The meter bridge shown in photo is one of the optional accessories.
    Before attempting to connect or operate this product, please read these instructions completely. 
    						
    							TRADEMARKS
    All trademarks are the property of their respective copyright holder for use in
    this document, including but not limited to; 
    ProTools is a registered trademark of DigiDesign
    ADAT is a registered trademark of ALESIS Corp.
    CS-10 is a registered trade mark of JL Cooper Electronics
    Macintosh is a registered trademark of Apple Computer, Inc.
    Windows is either a trademark or a registered trademark of Microsoft
    Corporation
    Copyright 2000 
    Limit of Liability/Disclaimer of Warranty:The author, Audio Video Systems
    Division of Matsushita Communication Industrial Co., LTD and Professional
    Audio Division of Panasonic Broadcast and Digital Systems Company have
    used their best efforts in preparing this book. However, Audio/Video Systems
    Division of Matsushita Communication Industrial Co., LTD and Professional
    Audio Division of Panasonic Broadcast and Digital Systems Company make
    no representation or warranties with respect to the accuracy or completeness
    of the contents of this book and hereby specifically disclaims any implied
    warranties or merchantability or fitness for any particular purpose and shall
    in no event be liable for any loss of profit or any other commercial damage,
    including but not limited to special, incidental, consequential, or other
    damages.
    2 
    						
    							Panasonic DA7 Upgrade Utility License Agreement
    Matsushita Communication Industrial Co., Ltd. (“MCI”) permits you to use the
    Panasonic DA7 Upgrade Utility software (“Software”) on condition of your acceptance
    of the following terms. As use of the Software shall be deemed that you have
    accepted the following terms, please read the following terms carefully before you use
    the Software.
    1. Copyright and License for use
    MCI grants you an individual and a non-exclusive right to use the Software on only
    single computer. You own the magnetic media on which the Software is originally or
    subsequently recorded or fixed, but MCI retains title to and ownership in the Software.
    The Software and the accompanying documentation are copyrighted by MCI.
    2. Prohibition and Restrictions
    You may not modify, adapt, translate, decompile, disassemble, reverse-engineer, or
    create derivative works based on the Software, nor may you allow another person to
    do so. The Software may not be duplicated, corrected, modified, lent, leased, sold,
    distributed, licensed or disposed of in any other way in part or in whole. The Software
    may not be transmitted over a network to another computer without written
    authorization from MCI. You may transfer the Software and accompanying
    documentation on a permanent basis to transferee provided it is for non-commercial
    purposes and you retain no copies and recipient agrees to the terms of this
    Agreement. 
    3. Limited Responsibility
    MCI shall not be liable for any direct, indirect, consequential, or incidental damages
    (including damages from but not limited to data loss, loss of business profit, business
    interruption, or loss of business information) arising out of the use of or inability to use
    the Software even, if MCI has been advised of the possibility of such damages.
    3 
    						
    							4
    (This page left blank intentionally.) 
    						
    							5
    The DA7 Upgrade Utility
    Users’ Guide
    Introduction
    Welcome to New Version 2.0 Operating System for the DA7.
    We hope you are enjoying your DA7, and that you will find that the 64
    enhancements we have included in the Version 2.0 operating system will
    increase your enjoyment of our product. Please note that there are changes
    in the default settings of the DA7, some of which will affect how you operate
    your mixer.  Please take a few moments to review the changes.
    This document covers ALL upgraded features to the original DA7 Operating
    System (Version 1.01/1.02).  Therefore, we strongly recommend that you
    review this document before you upgrade your console so that you are
    familiar with all the new features.
    We also recommend that you print and keep this document as a supplement
    to the DA7 operation manual that came with your DA7.  If you would like to
    have an electronic copy of the DA7 user guide, it can be downloaded from
    http://www.panasonic.com/proaudio.  Once you have entered this site, go to
    the download section and select DA7 User Guide. 
    						
    							6
    Important Notes:
    Due to the fact that there are many new default settings in the Version
    2.0 upgrade, we are recommending that you do a Master Reset of the
    console after the upgrade.  Therefore you should backup any settings
    in the Libraries, Scene Memories, Mixes, etc. BEFORE you begin the
    upgrade process.  Instruction for this process can be found in Section
    1. After the upgrade, make certain that you look at the MIDI REMOTE
    and INPUT MTX windows on the LCD to see if they are properly
    assigned.  If they are not, please reset them to your desired settings or,
    do a master reset to the console to return the DA7 to the new factory
    default settings.
    There are several updates to the default settings that may have an affect on
    the settings in your console.  This will protect you from accidental erasure of
    any of your presets.  After the upgrade, simply restore the data you have
    saved following the instructions in Section 1.
    If you are planning to use our optional automation software package (MAX),
    please be aware that you must be running at least O.S. Version 1.10 for it to
    operate properly, and we recommend that you upgrade your DA7 to Version
    2.0 for optimum performance.
    Some of the features documented here are from intermediate upgrade
    versions.  If you are upgrading your console from Version 1.01 or 1.02, all of
    the features in this document will apply to you. If you have previously
    upgraded your console to Version 1.10-1.20-1.21 or 1.22, you have already
    been using some of the features documented here in Section 2. 
    If you are upgrading from version 1.21 or 1.22, you should follow all the
    instructions in Section 1, and then you may proceed directly to Section 3.
    Contents:
    Section 1 - Upgrade Utility instructions
    Section 2 - Upgrade from Version 1.01/1.02/1.10/1.20
    Section 3 - Upgrade from Version 1.21 or 1.22
    Section 4 - APPENDIX - New Default Settings 
    						
    							1-1
    Section 1
    Upgrade Utility Instructions
    Contents
    Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
    Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
    Cables and Connections . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
    Setting up the DA7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
    Operating the DA7 Upgrade Utility . . . . . . . . . . . . . . . . . 1-7
    [SETUP] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
    [VERSION] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
    [BACKUP]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
    [UPGRADE] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
    [RESTORE] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
    [EXIT] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
    Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 
    						
    							1-2
    Preface
    The DA7 Upgrade Utility is a multifunction software manager program
    specifically designed to allow you to perform operating system upgrades, as
    well as backup and restore functions for the library, scene memory,
    automation data, as well as setup data for the DA7. 
    Using the serial ports on the DA7 and your computer, data can be sent to or
    from a DA7 and then saved to your computer hard disk for backup and
    retrieval. The memories and programs can be retrieved individually, or in
    groups. The retrieved memory and program titles can be edited using the
    computer’s keyboard. The data, including edited titles, can be transmitted
    between the computer and the DA7.
    Installation
    It is recommended that you perform a backup of your current data BEFORE
    you perform an upgrade to your DA7s operating system.
    Macintosh Version
    1. Copy the files for installation file (DA7UPINS) to a folder on to your hard
    drive.
    2. Once you have loaded the file, you need to open the folder to gain access
    to the following files:
    DA7UPG - Executable file of the Upgrade Utility
    V200R23.mot - Upgrade file for the DA7 
    CNV - Data Conversion folder for old backup versions 
    BKUP - Backup Data folder 
    3. Open the file “DA7UPG”.
    4. Test the communication path between the computer and your DA7 by
    clicking on the VERSION button on your computer in the open window.
    If it is properly connected, you will see the version of software that is
    currently in your DA7 displayed, and the “BACKUP” and “RESTORE”
    buttons will become active. (You need to set up DA7 and Upgrade Utility
    Configuration before test. To set up Configuration, read the following
    chapter “Cables and Connections”, “Setting up the DA7”, and “[Setup]” in
    “Operating the DA7 Upgrade Utility”.) 
    						
    							1-3
    Windows Version
    1. Copy the files for installation file (DA7UPINS.EXE) to folder on to your
    hard drive.
    2. Double–click on “DA7IPINS.exe”, If you are unzipping the file, you can
    unzip it. The installation file installs the upgrade utility in
    “C:\UpgradeDA7”.
    3.Once you have loaded the file, you need to open the folder to gain access
    to the following files:
    DA7UPG.exe - Executable file of the Upgrade Utility
    V200R23.mot - Upgrade file for the DA7 
    CNV - Data Conversion folder for old backup versions 
    BKUP - Backup Data folder
    4. Click on DA7UPG.exe to open the utility.
    5. Test the communication path between the computer and your DA7 by
    clicking on the VERSION button on your computer in the open window.
    If it is properly connected, you will see the version of software that is
    currently in your DA7 displayed, and the BACKUP and RESTORE buttons
    will become active. (You need to set up DA7 and Upgrade Utility
    Configuration before test. To set up Configuration, read the following
    chapter “Cables and Connections”, “Setting up the DA7”, and “[Setup]” in
    “Operating the DA7 Upgrade Utility”.) 
    						
    							1-4
    Cables and Connections
    For Macintosh Computer
    Use ONLY the recommended serial cable (cross cable) with a wiring
    pattern as described below.  This cable is the same cable used for the
    ImageWriter II printer.  Do NOT use a standard Macintosh Serial cable.
    Use this to connect between the modem port or printer port of the
    computer and the TO PC port of the DA7.
    For Windows/95 or PC compatible computer
    Use ONLY a serial cable with a wiring pattern as described below.  This
    cable is available from Panasonic Pro Audio in the United States, part
    number DA/DB-DIN.  Do NOT use a standard serial cable.
    Use this cable to connect between the serial port (COM1, COM2, COM3
    or COM4) of your PC and the TO PC port of the DA7.
    When using a Windows computer, use the following cable:
    Pinout configuration of the cable.  When building this cable, connect the
    pins in the following manner:
    DA7 port (Mini DIN 8p) pin # PC port (D-sub 9p) pin #
    1  . . . . . .8
    2  . . . . . .7
    3  . . . . . .2
    4  . . . . . .5
    5  . . . . . .3
    7
    8
    3
    5
    2 1
    2
    3
    4
    5Pin #Pin #
    1
    2
    3
    4
    5
    6
    7
    8
    Frame  1
    2
    3
    4
    5
    6
    7
    8
    Frame 
    Shield wire
    Pin #Pin #
    Mini DIN 8 (Male)DB9 (Female)
    Windows 
    Computer TO PC of the DA7 Mini DIN 8 (Male)
    Mini DIN 8 (Male)
    TO PC of the DA7MODEM or 
    Printer port of
    Mac Computer 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Upgrade Utility For Audio Mixer WR-DA7 Version 2.0 Users Guide