Home > Flir > Thermovision > ThermovisionFLIR FPTSeries Payload Installation Guide

ThermovisionFLIR FPTSeries Payload Installation Guide

    Download as PDF Print this page Share this page

    Have a look at the manual ThermovisionFLIR FPTSeries Payload Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 33 Flir manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							427-0031--00-12  Rev. 110    Payload Installation Guide 
     
    11 
     6) To change the parameters, select the Devices tab (near the top center of the 
    page) and then select the Infrared link from the list of devices on the left of the 
    page.  
     
    Figure 3:  Infrared Device Configuration 
    7) Modify the FOV Degrees parameter to match the horizontal FOV of the new 
    payload.  
    8) If the new payload has a different resolution, modify the Frame Size X and Frame 
    Size Y to match the resolution of the new payload.  
    						
    							427-0031--00-12  Rev. 110    Payload Installation Guide 
     
    12 
     Note: Setting the Frame Size parameters does not actually change the 
    resolution of the camera. The parameters are used for information purposes 
    in the FLIR Sensors Manager (FSM) software. 
    Saving Configuration Changes 
    After making any configuration changes, it is necessary to save the changes to the 
    server (there is a Save button at the bottom of each configuration page). Once you save 
    configuration changes to the server, the changes do not take effect immediately. 
    Generally it is also necessary to stop and restart the server for the changes to become 
    effective. The server has a configuration that is in effect and running, and another 
    configuration that is saved (and possibly different than the running configuration). The 
    following message indicates the saved configuration is different than the configuration in 
    effect (the running configuration): “You must restart the server for the changes to be 
    effective”.  
     
    Restarting the Server 
    To restart the server, first click on the Stop button at the top of the page, and wait for 
    the page to refresh. When the server is stopped and the page is refreshed, the status 
    will show as “Server Stopped” and the button at the top of the page will change to Start 
    rather than Stop. 
     
    Click on the Start button to restart the server, and when the page refreshes, the status 
    will again show as “Server Running…”. It may take up to 15 seconds to start the server, 
    depending on the configuration.  
      
    						