IR Imager Status Byte  
The status byte (Byte 2) of all commands to the IR Imager should, under normal operating conditions, 
contain 00
H.  For all responses, the thermal imager will set the status byte in accordance with the 
following table: 
 
Status Byte 
Value (hex) 
Definition Description 
0x00  CAM_OK  Function executed  
0x01  CAM _BUSY  Camera busy processing serial 
command 
0x02  CAM _NOT_READY  Camera...

Page 32

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   32 
AGC Type       
Plateau 
Equalization 6E0000130002E5CA00000000 6E0000130002E5CA00000000  
Linear 
Histogram 6E0000130002E5CA000550A5 6E0000130002E5CA000550A5  
Logarithmic 6E0000130002E5CA000660C6  6E0000130002E5CA000660C6   
Command Value Command Word  System Response Notes
Get FPA 
Temp 6E0000200002793F00000000  6E0000200002793F(abcd)XXXX  ab cd Hex Deg 
C  XXXX is 
CRC 2 
Shutter 
Position    
Open...

Page 33

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   33 
 100 6E00003F0002166D00000000  6E00003F0002166D00000000   
 200 6E00003F0002166D00642C22  6E00003F0002166D00642C22   
 300 6E00003F0002166D00C85844  6E00003F0002166D00C85844   
 400 6E00003F0002166D012CDFD6 6E00003F0002166D012CDFD6  
 500 6E00003F0002166D0190B088  6E00003F0002166D0190B088   
 600 6E00003F0002166D0258BD9F  6E00003F0002166D0258BD9F   
 700 6E00003F0002166D02BC0035  6E00003F0002166D02BC0035   
 800...

Page 34

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   34 
10.3 Daylight Camera  
This section describes the structure of the commands of the daylight camera on the PTZ-35 MS / PTZ-
50 MS Sensor.  Note that all data values are called out in hexadecimal.  The command and response 
strings of the daylight camera interface are of variable length, ranging from of 5 to 32 bytes.  The 
format for these command / response strings differs from the IR Imager in that the number of...

Page 35

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   35 
10.4 Pan/Tilt Mechanism  
This section describes the structure of the commands for the Pan/Tilt on the PTZ-35 MS / PTZ-50 MS 
Sensor.  Note that all data values are called out in hexadecimal.  The command and response strings 
of the Pan / Tilt Mechanism interface are of variable length, ranging from 5 to 32 bytes.  The format for 
these command / response strings differs from the IR Imager in that the number of...

Page 36

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   36 
WW=Tilt Speed, 0 to FEH,  
FE
H = fastest 
Min value = 28
H typical 
Up Right  81010601VVWW0201 FF  90 41 FF 90 51 FF  VV=Pan Speed, 0 to FEH,  
FE
H = fastest 
WW=Tilt Speed, 0 to FE
H,  
FE
H = fastest 
Min value = 28
H typical 
Down Left  81010601VVWW0102 FF  90 41 FF 90 51 FF  VV=Pan Speed, 0 to FEH,  
FE
H = fastest 
WW=Tilt Speed, 0 to FE
H,  
FE
H = fastest 
Min value = 28
H typical 
Down Right...

Page 37

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   37 
10.5 Pelco  D  Commands 
This section describes the structure of the Pelco D commands that the camera responds to. 
Pelco D Structure 
Byte 1  Byte 2 Byte 3 Byte 4 Byte 5Byte 6 Byte 7 
Sync Byte  Address Command 
1 Command 
2 Data 1  Data 2  Checksum 
FF Desired Pelco 
Address xx  xx  xx  xx  Hex Sum of Bytes 2-6 
 
Standard Command Set 
  Bit 7  Bit 6  Bit 5  Bit 4  Bit 3  Bit 2  Bit 1  Bit 0  
Command 1   -  -  -...

Page 38

427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   38 
(0x5B) 
Query Zoom 
Position  00 
0x55   0 0Extended 
(0x5D)  
 
Extended Response 
Byte 1  Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 
Sync Byte  Address  0x00  opcode  Data1  Data2  Checksum 
Query Pan 
Response 
     0x59 Pan position 
MSB  Pan position 
LSB    
Query Tilt 
Response 
     0x5B Tilt position 
MSB  Tilt position 
LSB    
Query Zoom 
Response 
     0x5D Zoom 
position MSB Zoom 
position LSB    
 
The...

Page 39

 
427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   39 
Installation Notes 
 
____________________________________________________________________________
 
 
____________________________________________________________________________
 
 
____________________________________________________________________________
 
 
____________________________________________________________________________...

Page 40

 
427-0116-00-10 Revision 140     Copyright © 2010 FLIR Systems, Inc.                   40 
11.0 USER CONTROLS FOR KBD300A 
 
  
 
    
Keystrokes  PTZ-35 MS / PTZ-50 MS Function Toggle Values (default to first 
value) 
Near button  Increments DLTV Focus closer    
Far button  Increments DLTV Focus farther    
CW Joystick  Increments DLTV Zoom closer    
CCW Joystick  Increments DLTV Zoom farther    
1, Aux On  IR Polarity to Black Hot 
  
1, Aux Off  IR Polarity to White Hot 
  
2, Aux On  Set IR to 2X...