    - 68 -  
                  
    < 2 > P A R A M E T E R    S E T
     
    S P E E D          9 6 0 0 b p s
     
                 (11)  RS232C communication speed setting: 
      Select a communication speed using the 
    [FEED] and [RESTART] 
            [PAUSE] 
     
    (12)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    D A T A    L E N G .    8 b i t s
     
                 (13)  RS232C data length setting: 
      Select a data length using the [FEED] and 
    [RESTART] keys. 
            [PAUSE] 
     
    (14)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    S T O P    B I T         1 b i t
     
                 (15)  RS232C stop bit length setting: 
      Select a stop bit length using the [FEED] and 
    [RESTART] keys. 
            [PAUSE] 
     
    (16)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    P A R I T Y              E V E N
     
                 (17)  RS232C parity setting: 
      Select a parity value using the [FEED] and 
    [RESTART] keys. 
            [PAUSE] 
     
    (18)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    X O N + R E A D Y        A U T O
     
                 (19)  RS232C flow control method setting: 
      Select a flow control method using the [FEED] 
    and [RESTART] keys. 
            [PAUSE] 
     
    (20)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    L C D       E N G L I S H
     
                 (21)  Setting of language for LCD messages: 
      Select a language for LCD messages using the 
    [FEED] and [RESTART] keys.   
            [PAUSE] 
     
    (22)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    F O R W A R D    W A I T    O F F
     
                 (23)  Setting of forward feed standby after an issue:
      Enable/disable the forward feed standby 
    function using the [FEED] and [RESTART] 
    keys. 
            [PAUSE] 
     
    (24)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    C O D E      E S C , L F , N U L
     
                 (25)  Control code setting: 
      Select a control code using the [FEED] and 
    [RESTART] keys. 
            [PAUSE] 
     
    (26)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    P E E L    O F F   S T S    O F F
     
                 (27)  Strip wait status setting: 
      Enable/disable the Strip wait status function 
    using the [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (28)  Press the [PAUSE] key. 
                   
    						
    							 
    - 69 -  
                  
    < 2 > P A R A M E T E R    S E T
     
    F E E D    K E Y         F E E D
     
                 (29)  [FEED] key function setting: 
      Select a function of the [FEED] key using the 
    [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (30)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    K A N J I    C O D E    T Y P E 1
     
                 (31)  Kanji code setting:   
    Select a Kanji code using the [FEED] and 
    [RESTART] keys. 
            [PAUSE] 
     
    (32)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    E U R O    C O D E          B 0
     
                 (33)  Euro code setting: 
      Select a Euro code using the [FEED] and 
    [RESTART] keys. 
            [PAUSE] 
     
    (34)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    A U T O  H D  C H K    O F F
     
                 (35)  Automatic head broken dots check setting: 
      Enable/disable the automatic head broken dots 
    check using the [FEED] and [RESTART] keys.
            [PAUSE] 
     
    (36)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    A C K / B U S Y       T Y P E 1
     
                 (37)  Centronics ACK/BUSY timing setting: 
      Select an ACK/BUSY timing using the [FEED] 
    and [RESTART] keys. 
            [PAUSE] 
     
    (38)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    W E B    P R I N T E R      O F F
     
                 (39)  Web printer function setting: 
      Enable/disable the web printer function using 
    the [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (40)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    I N P U T    P R I M E      O N
     
                 (41)  Setting of reset process when the nInit signal is 
    ON: 
      Enable/disable the reset process function 
    using the [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (42)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    R B N    N E A R   E N D    7 0 m
     
                 (43)  Ribbon near end detection setting: 
      Select a remaining ribbon length to be detected 
    as a ribbon near end state using the [FEED] 
    and [RESTART] keys. 
            [PAUSE] 
     
    (44)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    E X . I / O            T Y P E 1
     
                 (45)  Expansion I/O operation mode setting: 
      Select an operation mode using the [FEED] 
    and [RESTART] keys. 
            [PAUSE] 
     
    (46)  Press the [PAUSE] key. 
                   
    						
    							 
    - 70 -  
                  
    < 2 > P A R A M E T E R    S E T
     
    P L U G  &  P L A Y    O F F
     
                 (47)  Plug-and-play operation setting: 
      Enable/disable the plug-and-play operation 
    function using the [FEED] and [RESTART] 
    keys. 
     
            [PAUSE] 
     
    (48)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    L B L / R B N    E N D    T Y P 1
     
                 (49)  Label end/ribbon error process setting: 
      Select a label end or ribbon error process 
    using the [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (50)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    P R E    P E E L   O F F    O F F
     
                 (51)  Pre-strip process setting: 
      Enable/disable the pre-strip process function 
    using the [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (52)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    B A C K    S P E E D        S T D
     
                 (53)  Reverse feed speed setting: 
      Select a reverse feed speed using the [FEED] 
    and [RESTART] keys. 
            [PAUSE] 
     
    (54)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    M A X I    C O D E      T Y P E 1
     
                 (55)  MaxiCode specification setting: 
      Select a type of MaxiCode specification using 
    the [FEED] and [RESTART] keys. 
            [PAUSE] 
     
    (56)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    K B  I / F        O F F
     (57)  Keyboard I/F setting: 
    Enable/disable the keyboard I/F using the 
    [FEED] and [RESTART] keys. 
                  
            [PAUSE] 
    (58)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
    P E E L    O F F   T R Q    R 0(59)  Strip motor torque setting: 
    Select a strip motor torque using the [FEED] 
    and [RESTART] keys. 
                  
            [PAUSE] 
     
    (60)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
    T O N E    T A B L E    T Y P E 1(61)  Print head applied current table setting: 
    Select the type of table using the [FEED] or 
    [RESTART] key. 
                  
            [PAUSE] 
     
    (62)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     
    C U T    M O D E       T Y P E 1
     (63)  High speed cut issue: 
    Select a cut issue type using the [FEED] and 
    [RESTART] keys. 
                  
            [PAUSE] 
    (64)  Press the [PAUSE] key.  
    						
    							 
    - 71 - < 2 > P A R A M E T E R    S E T
    M U L T I    L A B E L      O F F(65)  Multiple-label set issue: 
    Enable/disable the function using the [FEED] 
    and [RESTART] keys. 
                  
            [PAUSE] 
     
    (66)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
    P A S S W O R D   O F F - - - -(67)  System mode password operation setting: 
    Set the system mode password operation 
    using the [FEED] or [RESTART] key. 
                  
            [PAUSE] 
     
    (68)  Press the [PAUSE] key. 
    < 2 > P A R A M E T E R    S E T
     (69)  The parameter setting menu is displayed. 
                 
      
     
      
    						
    							 
    - 72 -
    FEED 
    RESTART  6.3.2  Details of Various Parameter Setting   
    (1)  Character code (FONT CODE) 
     
     • PC-8 
     • PC-857 
     • PC-852 
     • PC-850 
     • Arabic 
     • LATIN9 
     • PC-1257 
     • PC-1254 
     • PC-1253 
     • PC-1252 
     • PC-1251 
     • PC-1250 
     • PC-855 
     • PC-851 
     • PC-866 
     • UTF-8 
     
     
    (2)  Font “0” (ZERO FONT) 
     
      •  0 (Without slash) 
      •  0 (With slash) 
     
     
     
     
     
     
    (3)  RS-232C communication speed (SPEED) 
     
     • 115200 bps 
     • 38400 bps 
     • 19200 bps 
     • 9600 bps 
     • 4800 bps 
     • 2400 bps 
     
     
    FEED 
    RESTART 
    FEED 
    RESTART NOTE: The following fonts do not support a zero with 
    a slash.    Therefore, even if a zero with a 
    slash is selected, a zero without a slash is 
    used. 
      [Bit map fonts] 
      OCR-A, OCR-B, GOTHIC725 Black, Kanji, 
    Chinese Kanji 
     [Outline fonts] 
      Price fonts 1, 2, and 3, DUTCH801 Bold, 
    BRUSH738 Regular, GOTHIC725 Black,   
    TrueType font
      
    						
    							 
    - 73 - (4)  RS-232C data length (DATA LENG.) 
     
     • 8 bits 
     • 7 bits 
     
     
     
    (5)  RS-232C stop bit length (STOP BIT) 
     
     • 2 bits 
     • 1 bit 
     
     
     
    (6)  RS-232C parity (PARITY) 
     
     • EVEN 
     • ODD 
     • NONE 
     
     
    (7)  RS-232C flow control method (XON/XOFF, READY/BUSY) 
      •  XON/XOFF AUTO  :  XON/XOFF protocol 
            (XON output when the power is on, XOFF 
    output when the power is off) 
      •  XON + READY AUTO  :  XON/XOFF + READY/BUSY (DTR) protocol 
            (XON output when the power is on, XOFF 
    output when the power is off) 
     • READY/BUSY : READY/BUSY (DTR) protocol 
            (No XON output when the power is on, no 
    XOFF output when the power is off) 
     • XON/XOFF : XON/XOFF protocol 
            (No XON output when the power is on, no 
    XOFF output when the power is off) 
      •  READY/BUSY RTS  :  RTS protocol 
            (No XON output when the power is on, no 
    XOFF output when the power is off) 
     
    FEED 
    RESTART 
    FEED 
    RESTART 
    FEED 
    RESTART 
    FEED 
    RESTART  
    						
    							 
    - 74 - (8)  Language for LCD messages (LCD) 
     
     • ENGLISH 
     • ITALIAN 
     • JAPANESE 
     • SPANISH 
     • DUTCH 
     • FRENCH 
     • GERMAN 
     
     
    (9)  Forward feed standby after an issue (FORWARD WAIT) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    FEED 
    RESTART 
    [FEED]  [RESTART] 
    FORWARD WAIT OFF
    FORWARD  WAIT  ON
    POSITION  +0.0mm
    POSITION  +0.1mm
    POSITION  +5.0mm
    POSITION  -5.0mm
    [PAUSE] 
    [FEED] [RESTART]
    [FEED] [RESTART]
    [FEED] [RESTART][FEED]
    [RESTART]
    POSITION  -4.9mm [FEED] [RESTART]
    POSITION  -0.1mm [FEED] [RESTART]
    • OFF:  Disabled   
    • ON:  Enabled 
    Setting for a fine adjustment value for a stop 
    position after a forward feed standby: 
      -5.0 mm to +5.0 mm 
      +:  Performs a longer length of a forward 
    feed, then stops. 
      -:  Performs a shorter length of a forward 
    feed, then stops.  [FEED]  [RESTART]  
    						
    							 
    - 75 - (10)  Control code (CODE) 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    (11)  Strip wait status (PEEL OFF STS) 
     
     • OFF: Disabled  
     • ON: Enabled 
     
     
    (12)  [FEED] key function (FEED KEY) 
     
      •  FEED:  Feeds one label. 
      •  PRINT:  Prints data in the image buffer on one label. 
     
     
    FEED 
    RESTART [FEED]  [RESTART] 
    CODE        AUTO 
    CODE  ESC,LF,NUL
    CODE       {  |  } 
    CONTROL CODE1 1B
    CODE      MANUAL 
    CONTROL CODE2 0A[PAUSE] 
    PEEL OFF STS OFF
    CONTROL CODE3 00
    [FEED]  [RESTART] 
    [FEED]  [RESTART] 
    [PAUSE] 
    [PAUSE] 
    [PAUSE] 
    [FEED] [FEED] [RESTART]
    CONTROL CODE1 02 
    CONTROL CODE1 01 
    CONTROL CODE1 FE 
    CONTROL CODE1 00 
    CONTROL CODE1 FF  [FEED][RESTART]
    [FEED][RESTART]
    [FEED][RESTART]
    [RESTART] [FEED]  [RESTART] 
    FEED 
    RESTART [FEED]  [RESTART] 
    CODE   IBM  HOST NOTE: IBM HOST is only for the Japan model.  
    						
    							 
    - 76 - (13)  Kanji code (KANJI CODE) 
     
     
     
      
     
    (14)  Euro code (EURO CODE) 
     
     
     
     
     
    (15)  Automatic head broken dots check (AUTO HD CHK) 
     
      •  OFF:  A head broken dots check is not automatically performed when 
    the power is turned on. 
      •  ON:  A head broken dots check is automatically performed when the 
    power is turned on. 
     
     
    (16)  Centronics ACK/BUSY timing (ACK/BUSY) 
     
      •  TYPE 1    BUSY goes low at the same time as when ACK goes high. 
      •  TYPE 2    BUSY goes high at the same time as when ACK goes low. 
     
     
     
    (17)  Web printer function (WEB PRINTER) 
     
      •  OFF:  Web printer function is disabled. 
      •  ON:  Web printer function is enabled. 
     
     TYPE 1:  For Windows codes 
    TYPE 2:  For original codes 
    FEED 
    RESTART 
    FEED 
    RESTART 
    FEED 
    RESTART 20H 
    FFH 
    KANJI CODE TYPE1
    KANJI CODE TYPE2[FEED] [RESTART]
    EURO  CODE     B0 
    EURO  CODE     B1  [FEED] [RESTART] 
    						
    							 
    - 77 - (18)  Reset process when the nInit signal is ON (INPUT PRIME) 
     
      •  OFF:  The reset process is not performed. 
      •  ON:  The reset process is performed. 
     
     
     
    (19)  Ribbon near end detection (RBN NEAR END) 
      •  70 m:  A ribbon near end state is detected when the remaining ribbon 
    length is approximately 70 m. 
      •  30 m:  A ribbon near end state is detected when the remaining ribbon 
    length is approximately 30 m. 
      •  OFF:  A ribbon near end state is not detected. 
      NOTE: There are some variations in detecting a ribbon near end 
    state.    It is preferable to use this setting for reference 
    purposes. 
     
     
    (20)  Expansion I/O operation mode (EX. I/O) 
     
     • TYPE1: Standard mode 
     • TYPE2: In-line mode 
     
     
     
     
    (21)  Plug-and-play operation (PLUG & PLAY) 
     
      •  OFF:  A plug-and-play operation is disabled. 
      •  ON:  A plug-and-play operation is enabled. 
     
      NOTE:  In the USB interface, plug-and-play operations are always 
    enabled, regardless of this setting. 
    FEED 
    RESTART 
    FEED 
    RESTART 
    FEED 
    RESTART 
    FEED 
    RESTART  
    						
    All Toshiba manuals Comments (1)