    Have a look at the manual Toshiba Strata S Electronic Key Telephone System Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SYSTEM PROGRAMMI#G 
    SECTION 100-003-390 
    JULY 1994 
    e.. . - 
    TABLE 9 
    PROGRAM 20-TOLL RESTRICTION DISABLE 
    1. Lock in SET switch. 
    2. Depress the (SPKRI key on station 17. 
    3. Dial 
    q q on dial pad. 
    4. Refer to the System Record Sheet. 
    Using the m keys, turn the associated 
    LEDs on or off, as required. Each CO 
    key/LED represents itself-that is, if the CO 1 
    LED is on, Toll Restriction will not function on 
    CO 1. If CO 1 LED is off, Toll Restriction will 
    function on CO 1 _ etc. 
    5. Depress the l=I key to place new data 
    in memory. 
    6A. Go to Step 2 in another program table 
    . . . or. . . 
    66. Transfer data into working memory per 
    Paragraph 02.06. SET LED on. 
    Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steadv on. 
    SPKR LED flashes continuously. 
    CO LEDs are on according to present data. 
    An X on the record sheet means the LED 
    should be on. 
    If the LED is already on, depressing the 
    associated key will turn it off and vice- 
    versa. LEDs may be turned off and on until 
    the desired pattern is set. : 
    All station 17 LEDs (except MW/FL) go off.. 
    SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored. previous data is erased.  
    						
    							SYSTEM PROGRAMMING 
    SECTION 199-993-399 
    JUCY 1994 
    TABLE 10 
    PROGRAM 2X-TOLL RESTRICTION EXCEPTION CODES 
    1. Lock in SET switch. 
    2. Depress the /SPKRl key on station 17. 
    3. Dial 
    q a on the dial pad. X = 1,2,3, 
    ztc.-the system will store a maximum of five 
    ties. Dial 0111 (X = 1) to program first 
    exception code, 
    q @ (X = 2) to program 
    second 
    exception code, etc. 
    4. Refer to the System Record Sheet. Using 
    :he dial pad, enter the required 4-digit excep- 
    :ion code (four digits must be entered). 
    l ff less than four digits are used, enter q 
    for remaining digits. 
    1 I I I SET LED on. 
    Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    AD 2 LED will flash. 
    INT, CO 1,2 & 3 LEDs will light to display 
    data in Binary format. 
    2nd Digit  AD 2. 3 & 4 LEDs will light steadily to indi- 
    cate which digit is being displayed. 
    * 
    I I 
    Steady 
    3rd Digit 
    Steady 
    Steady 
    4th Dieii 
    steady Kev/LED Start 
    AD4 
    L AD3 
    AD2 Flash 1st Digit 
    steady 
    , co3 Binatv Data Binary Data Binary Data Binary Data 
    I co2 Binary Data Binary Data 
    Binary Data Binary Data 
    . co1 8inary Data Binary Data 
    Binary Data Binary Data 
    INT Binary Data Binary Data Binary Data Binarv Data 
    NOTES: 
    1. Depressing the 
    q key displays the data wtihout changing it The first q 
    the second q 
    will displa y the first dig&- 
    will display the second dig& etc. 
    data without ente 
    X=LEDon 
    AllLEDsoff=nodata 
    I memorv. 
     Return to Step 2 in order to continue 
    th this program 
    . ..or... 
    Go to Step 2 in another program table 
    . . . or... 
    Tran3er data into working memory per 
    lgraph 02.06. 
    ,. - 
    SET LED goes off. 
    Station 17 MW/FL LED goes off.  
    						
    							SYSTEM PROGfIAMYlNG 
    SECTION lW4G3400 
    JULY 1984 . - 
    TABLE 11 
    PROGRAM SXX-STATION CO LINE ACCESS 
    1. Lock in SET switch. 
    2. Depress the 
    1 SPKR [ key on station 17. 
    3. Dial mm @ on the dial pad. XX = the 
    number of the station(s) to be programmed. 
    l Enter q n if all stations are to be 
    programmed simultaneously. 
    l Enter q m if four lower numbered 
    stations (10 - 13) are to be programmed 
    simultaneously. SET LED on. 
    Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    CO LEDs will be on according to present 
    data. 
    l Enter j?jj (?l if four higher numbered 
    stations (14 - 17) are to be programmed 
    simultaneously. I 
    4. Refer to the System Record Sheet. Using 
    the CO keys, turn their associated LEDs on or 
    off, as required. 
    0 LED on = Access allowed 
    l Each CO key/LED represents itself-that 
    is, if the CO 1 LED is on, then the station 
    being programmed (XX) is allowed access 
    to CO 1, etc. 
    5. Depress the 1-1 key to place new data 
    in memory. An X on the record sheet means the LED 
    should be on. 
    If the LED is already on, depressing its as- 
    sociated key will turn it off and vice-versa. 
    LEDs may be turned off and on until the 
    desired pattern is set. 
    All station 17 LEDs (except MW/FL) go off. 
    6A. Return to Step 2 in order to continue 
    with this program 
    66. Go to Step 2 in’&%& program table 
    . . . 
    6C. Transfer data intoOCwwking memory per 
    Paragraph 02.06. 
    , . SET LED goes off: 
    Station 17 MW/FL LED goes off. 
    New data is stored, previous data is erased. 
    ,.-- 
    -2o-  
    						
    							SYSTEM PROGRAMMING 
    - SECTION 
    100-003-300 
    JULY 1984 
    TABLE 12 
    . 
    PROGRAM 4XX-STATION TYPE and FLEXIBLE KEY ASSIGNMENT 
    SET LED on. 
    1. Lock in SET switch. Station 17 MW/FL LED on. 
    System is in program mode. 
    2. Depress the 
    1 SPKR 1 key on station 17. 
    3. Dial 1’ rrrl Kl on the dial pad. XX = the 
    number of the station(s) to be programmed. 
    l Enter Dm if all stations are to be pro- 
    grammed simultaneously. 
    l Enter q I if four lower numbered sta- 
    tions (10 - 13) are to be programmed 
    simultaneously. Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    INT & CO LEDs will be on according to 
    present data. 
    e Enter 
    q q if four higher numbered sta- 
    tions (14 - 17) are to be programmed 
    simultaneously. 
    4. Refer to the System Record Sheet. Using An X on the record sheet means the LED 
    the INT and CO keys, turn their associated should be on. 
    LEDs on or off, as required. If the LED is already on, depressing its as- 
    The detailed meaning of each key is shown sociated key will turn it off and vice-versa. - 
    below. LEDs may be turned off and on until the 
    desired pattern is set. 
    Key/LED. EKT TYPE” 
    1 O-key 20-key 
    co2 #2 #3 
    ,COl - #2 “See Figure 1 
    INT #1 #l 
    5. Depress the mj key to place new data All station 17 LEDs (except MW/FL) go off. 
    in memory. 
    6A. Return to Step 2 in order to continue 
    with this program 
    6B. Go to Step 2 in.ar%er program table 
    . . . or. . . 
    6C. Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored, previous data is erased. 
    ..- 
    -21-  
    						
    							SYSTEM PROGRAMMING ‘.. 
    SECTION 199-093-390 
    JULY 1994 
    e.. 
    TABLE 13 
    PROGRAM SXX-STATION CLASS OF SERVICE 
    1. Lock in SET switch. 
    all stations are to be pro- 
    if four lower numbered sta- 
    - 13) are to be programmed 
    simultaneously. 
    l Enter q m if four higher numbered sta- 
    tions (14 - 17) are to be programmed 
    and AD keys, turn their asso- 
    ciated LEDs on or off, as required. 
    The detailed meaning of each key is shown 
    below. should be on. 
    If the LED is already on, depressing its as- 
    sociated key will turn it off and vice-versa. 
    LEDs may be turned off and on until the 
    or. . . 
    6B. Go to Step 2 in’another program table 
    . . . or . . . 
    6C. Transfer data into working memory per 
    Paragraph 02.06. 
    /FL LED goes off. 
    red, previous data is erased. 
    ,. - 
    -22-  
    						
    							‘. SYSTEM PROGRAMMI#G 
    SECTlON100-003-300 
    JULY 1994 
    TABLE 14 
    PROGRAM GXX-TOLL RESTRICTION CLASSIFICATION 
    1. Lock in SET switch. W/FL LED on. 
    number of the station(s) to be programmed. 
    l Enter q j?jJ if all stations are to be pro- 
    grammed simultaneously. 
    l Enter a/-i-J if four lower numbered sta- 
    tions (10 - 13) are to be programmed 
    simultaneously. . . 
    l Enter ]a p) if four higher numbered sta- 
    D keys, turn their asso- 
    IS already on, depressing its as- 
    with this program 
    66. Go to Step 2 in’ar$her program table 
    6C. Transfer data into working memory per 
    Paragraph 02.06. 
    -23-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 199-993-399 
    JULY 1994 
    v.. 
    TABLE 15 
    PROGRAM 7XX-STATION OUTGOING CALL RESTRICTION 
    SET LED on. 
    1. Lock in SET switch. 
    2. Depress the 
    ISPKR] key on station 17. 
    3. Dial 17 fl Kl on the dial pad. XX = the 
    number of the station(s) to be programmed. 
    l Enter /?jJa if all stations are to be 
    programmed simultaneously. 
    l Enter q j-iJ if four lower numbered 
    stations (10 - 13) are to be programmed 
    simultaneously. Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    CO LEDs will be on according to present 
    data. 
    l Enter m m if four higher numbered 
    stations (14 - 17) are to be programmed 
    simultaneously. 
    4. Refer to the System Record Sheet. Using 
    the CO keys, turn their associated LEDs on or 
    off, as required. 
    * LED on = Restricted outgoing calls. 
    l Each CO key/LED represents itself-that 
    is, if the CO 1 LED is on, then the station 
    being programmed (XX) is restricted from 
    outgoing calls on CO 1, etc. ’ 
    . 
    An X on the record sheet means the LED 
    should be on. 
    If the LED is already on, depressing its as- 
    sociated key will turn it off and vice-versa. 
    LEDs may be turned off and on until the 
    desired pattern is set. 
    5. Depress the [‘I key to place new data 
    in memory. All station 17 LEDs (except MW/FL) go off. 
    6A. Return to Step 2 in order to continue 
    with this program 
    68. Go to Step 2 in’igthei program table 
    . . . or. . . 
    6C. Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored, previous data is erased. 
    . . - 
    -24-  
    						
    							w.. SYSTEM PROGRAMMING 
    SECTION 100-003-300 
    JULY 1994 
    TABLE 16 
    PROGRAM 8xX-CO RINGING ASSIGNMENTS-DAY 
    SET LED on. 
    1. Lock in SET switch. Station 17 MW/FL LED on. 
    System is in program mode. 
    2. Depress the ISPKR 1 key on station 17. 
    3. Dial mm m on the dial pad.* XX = the 
    number of the station(s) to be programmed. 
    0 Enter 
    q a if all stations are to be 
    programmed simultaneously. Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    CO LEDs will be on according to present 
    data. 
    l Enter q m if four lower numbered 
    stations (10 - 13) are to be programmed 
    simultaneously. 
    l Enter m m if four higher numbered 
    stations (14 - 17) are to be programmed 
    simultaneously. 
    4. Refer to the System Record Sheet. Using 
    the CO keys, turn their associated LEDs on or 
    off, as required. 
    l LED on = Ring in DAY mode. 
    0 Each CO key/LED represents itself-that 
    is, if the CO 1 LED is on, then the station 
    being programmed (XX) will ring when a 
    call comes in on CO 1 in 
    DAY mode. 
    5. Depress the m) key to place new data 
    in memory. An X on the record sheet means the LED 
    should be on. 
    If the LED is already on, depressing its as- 
    sociated key will turn it off and vice-versa. 
    LEDs may be turned off and on until the 
    desired pattern is set. 
    All station 17 LEDs (except MW/FL) go off. 
    6A. Return to Step 2 in order to continue 
    with this program 
    6B. Go to Step 2 in.ar%her program table 
    . . . or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06 SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored, previous data is erased. 
    NOTE: 
    Station(s) being designated to ring must be allowed access by Program 3XX. 
    ,.- 
    -25-  
    						
    							SYSTEM PROGRAMMING 
    SECTION 100-003-300 
    JULY 1994 
    TABLE 17 
    PROGRAM 9xX-CO RINGING ASSIGiVMENTS-NITE 
    1. Lock in SET switch. 
    2. Depress the m key on station 17. 
    3. Dial jq rjil rjil on the dial pad.* XX = the 
    number of the station(s) to be programmed. 
    l Enter q m if all stations are to be 
    programmed simultaneously. 
    l Enter q a if four lower numbered 
    stations (10 - 13) are to be programmed 
    simultaneously. SET LED on. 
    Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    CO LEDs will be on according to present 
    data. 
    l Enter m Tz] if four higher numbered 
    stations (14 - 17) are to be programmed 
    simultaneously. 
    4. Refer to the System Record Sheet. Using 
    the CO keys, turn their associated LEDs on or 
    off, as required. 
    l LED on = Ring in NITE mode. 
    l Each CO key/LED represents itself-that 
    is, if the CO 1 LED is on, then the station 
    being programmed (XX) will ring when a 
    call comes in on CO 1 in 
    NITE mode. 
    5. Depress the [mj key to place new data 
    in memory. An X on the record sheet means the LED 
    should be on. 
    If the LED is already on, depressing its as- 
    sociated key will turn it off and vice-versa. 
    LEDs may be turned off and on until the 
    desired pattern is set. 
    All station 17 LEDs (except MW/FL) go off. 
    6A. Return to Step 2 in order to continue 
    with this program 
    6B. Go to Step 2 in’ar%er program table 
    . ..or... 
    6C. Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored, previous data is erased. 
    NOTE: 
    Station&) being designated to ring must be al/owed access by Program 3XX. 
    -26-  
    						
    							SYSTEM PROGRAMMING 
    JULY 1984 . M.. 
    Strata s” 
    SYSTEM RECORD SHEET 
    PROGRAM 01 -SYSTEM ASSIGNMENTS 
    X = Select (LED on) Initialized Data: AD 4 LED on; all other LEDsoff 
    NOTE: 
    Only one Message Center is permitter2 if both stations 10 and ? 1 
    are chosen as Message Centers, station 10 will have priority. 
    PROGRAM 05 
    AUTOMATIC RECALL FROM HOLD TIMING 
    KEY/LED X TIME 
    AD4 ’ 18oseconds 
    AD3 128 Seconds 
    AD2 98 Seconds 
    AD1 
    84 !%cm& 
    co3 48 Seconds 
    co2 32 !Seconds 
    co i 18 Seconds 
    INT No Recall 
    X = Select (LED on) 
    Initialized Data: 32 Seconds 
    CO LINE OPTIONS 
    PROGRAM 06 PROGRAM 07 
    AUTOMATIC RELEASE AUTOMATIC RELEASE 
    ON HOLD ENABLE ON HOLD TIMING 
    X = Enable (LED on) 
    initialized Data: 
    All LEDs off X =X6 (LED on) ,.. 
    Initialized Data: 
    All LEDs off 