    Have a look at the manual Toshiba Strata Xiie, Strata Xxe Electronic Key Telephone Systems Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 19 
    PROGRAM 0#9 
    OFF-PREMISE LINE HUNTING 
    1) Lock in the SET switch on the HCAU. 
    uired. Each CO key/LED represents associated key will turn it off and vice versa. 
    first incoming CO line connected to LEDs may be turned off and on until the desired 
    (i.e., 1,4, 7, etc.) will ring the HUNT 
    output in the day and night mode if the asso- 
    ciated LED is off. If the LED is on, the HUNT 
    6B) Go to Step 2 in a%her program table 
    into working memory per 
    -4l-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 20 
    PROGRAM 100 
    TOLL RESTRICTION SYSTEM PARAMETERS 
    (DIALING PLAN) 
    1) Lock in the SET switch on the HCAU. 
    2) Depress the m key on station 17. 
    3) Dial 0 m 1 on the dial pad. 
    4) Refer to the System Record Sheet. 
    Turn the associated LED on for the dialing plan 
    of the home Area Code. Only one LED may be 
    on at one time. 
    5) Depress the m key to place new data 
    in memory. 
    6A) Return to Step 2 in order to continue with 
    this program 
    6B) Go to Step 2 in another program table 
    . . . or . ~ 
    6C) Transfer data into working memory per 
    Paragraph 02.06. SET LED on. 
    Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steady on. 
    SPKR LED flashes continuously. 
    CO LEDs go on according to present data. 
    An X on the record sheet means the LED should 
    be on. 
    If the LED is already on, depressing the asso- 
    ciated key will turn it off and vice versa. LEDs 
    may be turned off and on until the desired pat- 
    tern is set. 
    All station 17 LEDs (except MW/FL) go off. 
    SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored, previous data is erased. 
    -42-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 21 
    PROGRAM 101 
    TOLL RESTRICTION DISABLE 
    W/FL LED on. 
    1) Lock in the SET switch on the HCAU. 
    stem IS In program mode. 
    If the. LED is already on, depressing the asso- 
    ciated key will turn it off and vice versa. LEDs 
    may be turned off and on until the desired pat- 
    this program 
    6B) Go to Step 2 in another program table 
    -43-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 22 
    PROGRAM 102 
    FORCED ACCOUNT CODE CHECK 
    1) Lock in the SET switch on the HCAU. 
    associated LEDs 
    l LED ON = Forced Account Codes are checked. 
    l Each CO key/LED represents itself-that 
    is, if the CO1 LED is on, stations calling out 
    over CO1 will be forced to enter an account If the LED is already on, depressing the asso- 
    ciated key will turn it off and vice versa. LEDs 
    may be turned off and on until the desired pat- 
    this program 
    6B) Go to Step 2 in ar%her program table 
    ~ . ~ or . . ~ 
    6C) Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    New data is stored revious data is erased. 
    -44-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 23 
    PROGRAM 103 
    OCC or EQUAL ACCESS #1 
    1 SET LED on. 
    1) Lock in the 
    SET switch on the HCAU. Station 17 MW/FL LED on. 
    is in program mode. 
    X=LEDon 
    All LEDs off = no data 
    66) Go to Step 2 in aonb;h& program table 
    . . . or . . . 
    6C) Transfer data into ,working memory per 
    ~ Paragraph 02.06. 
    I SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    -45-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 24 
    PROGRAM 104 
    OCC AUTHORIZATION CODE LENGTH #I 
    1) Lock in the SET switch on the HCAU. tation 
    17 MW/FL LED on. 
    As each diglt IS entere 
    LEDs as shown below. 
    o-digit number is 
    X = LED on 
    . ..or... 
    6B) Go to Step 2 in another program table 
    . . . or . . . 
    6C) Transfer data into working memory per 
    Paragraph 02.06. 
    -46-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 25 
    PROGRAM 105 
    OCC or EQUAL ACCESS #2 
    W/FL LED on. 
    1) Lock in the SET switch on the HCAU. 
    X=LEDon 
    All LEDs off = no data 
    with this program 
    6B) Go to Step 2 in a%& program table 
    . . . or . . . 
    6C) Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    -47-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 26 
    PROGRAM 106 
    OCC AUTHORIZATION CODE LENGTH #2 
    1) Lock in the SET switch on the HCAU. W/FL LED on. 
    stem IS In program mode. 
    wo-digit number is 
    X=LEDon 
    6A) Return to Step 2 in order to continue 
    with this program 
    or . . ~ 
    6B) Go to Step 2 in inother program table . . 0 
    or . I . 
    6C) Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    -48-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 27 
    PROGRAM 108 
    TOLL RESTRICTION OVERRIDE CODE #I 
    W/FL LED on. 
    1) Lock in the SET switch on the HKSU. 
    LEDs as shown below. 
    X = LED on 
    All LEDs off = no data 
    lace new data in 
    6A) Return to Step 
    with this program 
    or . . . 
    6B) Go to Step 2 in inother program table 
    . . . or . . . 
    6C) Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    -49-  
    						
    							PROGRAMMING PROCEDURES 
    SECTION 300-020-300 
    JULY 1986 
    TABLE 28 
    PROGRAM 1 OS 
    TOLL RESTRICTION OVERRIDE CODE #2 
    I I 
    SET LED on. 
    1) Lock in the SET switch on the HKSU. Station 17 MW/FL LED on. 
    System is in program mode. 
    Normal functions halt on station 17. 
    SPKR LED steady on. 
    2) Depress the 
    l 3 key on station 17. 
    3) Dial 0 B m on the dial pad. SPKR LED flashes continuously. 
    CO LEDs indicate present data. 
    4) Refer to the System Record Sheet. This pro- As each digit is entered, the entry is verified by 
    gram registers the first Toll Restriction override LEDs as shown below. 
    code. This four-digit number is entered via the 
    X=LEDon 
    All LEDs off = no data 
    . ~ . or . . . 
    6B) Go to Step 2 in another program table 
    . . .or.. . 
    6C) Transfer data into working memory per 
    Paragraph 02.06. SET LED goes off. 
    Station 17 MW/FL LED goes off. 
    I 
    -5o-  
    						