Home > Trillium > Telephone > Trillium Panther Ii Feature Module Iv System Manual

Trillium Panther Ii Feature Module Iv System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Trillium Panther Ii Feature Module Iv System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 13 Trillium manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Trillium Standard  Practice 
    To MDF 
    stations:  24 
    Vdc  Battery 
    AC  Power  Backup 
    s 
    _~lllli~lllllllllllllllll~ll 
    4  0 
    IIIIIIIIIIIIIIIIIIIIIIIII 
    IIbdhn 
    -18to25  KEY Background 
    Music 
    Music  on Hold 
    AmDlifier 
    I  Feature  Module Cartridge 
    e  Power  Fail 
    Station 
    M:yge  I 
    rl 
    . 
    Answer 
    Door  Unit 
    Module 
    Dl 02 
    DA 
    Incoming  - 
    $%xBW  Lines  
    (1  -8) 
    !53 
    Printer  / Terminal 
    Figure  6-l (a)  Panther  II 820  Main  Configuration 
    Installation  and Commissioning 
    Page  12  
    						
    							Panther II 820/1032/2064-200 
    A 
    a 
    T 
    24 Vdc Battery 
    AC Power Backup 
    To MDF 
    stations: 
    Back round Music 
    Music on Hold 
    I Feature Module Cartridge 
    II Door 
    III III 
    Station 
    MreTtt 
    Recorder Connect to 
    Panther 2064 
    Cabinet or 
    connect to 
    6 C.O. Line 
    Module, if 
    applicable 
    I 
    Incoming 
    C.O./PBW 
    Centrex Lines 
    (1 
    - 10) 
    II I I 
    557 
    To Printer/Terminal 
    Figure 6-l(b) Panther II 1032 Main Configuration 
    Installation and Commissioning 
    Page 13  
    						
    							Trillium Standard Practice 
    To MDF 
    stations: 
    AC Pnwer 24 Vdc Battery L’ I 
    Backup 
    , ._ . __._. 
    I 
    ~lllllllllllllllllllli L 
    KEY 
    SEURNL;FE Power Fail 
    Connect to 
    Panther 1032 
    Cabinet 
    1 I= -ill Incoming 
    C.O./PBX/ 
    Centrex Lines 
    (11 -20) 
    Figure 6-l(c) Panther II 2064 Main Configuration 
    Installation and Commissioning 
    Page 
    14  
    						
    							Panther II 820/1032/2064-200 
    Mounting System Components 
    6.0 4 The following instructions detail the installation of the KSU. The installation 
    procedure is similar for any ancillary devices included in the system, only the location 
    of the mounting screws may differ. This can be seen in Figures 6-2 to 6-6. 
    Step 1. 
    Using suitable fasteners, mount a wooden backboard, of sufficient size 
    to accommodate the KSU and ancillaq devices (if any), to the wall, 
    within 4 feet of the ac outlet and at least 12 inches (305 mm) above the 
    floor. Allow room for installation of the ancillary devices which may be 
    installed at a later date. 
    Step 2. Position the KSU on the backboard. Mark the positions of the KSU’s 
    four mounting screws on the backboard. 
    Step 3. Install the mounting screws supplied, into the backboard, leaving 
    approximately an 0.2 inch (5 mm) gap between the back of the screw 
    head and the backboard. 
    Step 4. 
    Hang the KSU on the mounting screws. Tighten the mounting screws. 
    Caution: Do not connect the KSU power cord until instructed to do so. I 
    Step 5. Repeat Steps 1 through 4 for each of the ancillary devices to be 
    installed. 
    Installing the Feature Module Cartridge 
    6.0 
    5 Panther II 820 and 1032 Key Service Units have a Feature Module Cartridge 
    that contains the software for the Panther II features. 
    Step 1. Unpack the Feature Module Cartridge. An information sheet packed 
    with the Feature Module Cartridge provides an installation diagram. 
    Step 2. There are two small grooves on the Feature Module Cartridge 
    connector. Holding the Feature Module Cartridge so that the grooves 
    are facing you, plug it into the port that is located halfway down the 
    right-hand side of the KSU. 
    Step 3. Place the protective cover over the Feature Module Cartridge, push in 
    the plastic expander plugs, and tighten the two screws. 
    Installation and Commissioning 
    Page 15  
    						
    							Panther II 820/1032/2064-200 
    t 
    17.8 cm 
    (7 inch) 14.9 cm 
    (5.875 inch) 
    Wooden 
    Backboard 
    Door 
    / Answer 
    Unit 
    Figure 6-3 Door Answer Unit Wall Mounting 
    Installation and Commissioning 
    Page 17  
    						
    							Trillium Standard Practice 
    --. 
    7.9 cm 
    (3.125 inch) 
    -1 Wooden 
    8.9 cm 
    (3.5 inch) Power 
    Fail 
    Transfer 
    Unit 
    Figure 6-4 Power Fail Transfer Unit Wall Mounting 
    Installation and Commissioning 
    Page 18  
    						
    							Panther II 820/1032/2064-200 
    7.9 cm 
    ( 3.11 inch) 
    r-7 Wooden 
    t n 1- 
    -. -. 
    . . 
    -. Station 
    Message 
    Detail 
    Recording 
    Unit 
    J Ull 
    (3.56 inch) 
    Figure 6 -5 SMDR Unit Wall Mounting 
    Connect The Equipment To Ground 
    6.0 6 The 
    KSU must be connected to ground through a single solid conductor. 
    Caution: DO NOT rely on the third wire (Green) of the AC cord to connect 
    the 
    KSU to ground. A separate external ground lead must be connected. 
    Installation and Commissioning 
    Page 19  
    						
    							Panther II 820/1032/2064-200 
    Step 2. 
    When the system comprises a 2064 KSU, repeat Step 1 for CO. lines 
    11 through 20. When a second Door Answering Unit forms part of the 
    system configuration, do not connect C.O. line 20. 
    Line Lead Designation Conductor Color MDF Terminal RJ21 Pin Number 
    1 Tip White-Blue 1 26 
    Ring Blue-White 2 1 
    2 Tip White-Orange 3 27 
    Ring Orange-White 4 2 
    3 Tip White-Green 5 28 
    Ring Green-White 6 3 
    4 Tip White-Brown 7 29 
    Ring Brown-White 8 4 
    5 Tip White-Slate 9 30 
    Ring Slate-White 10 5 
    6 Tip Red-Blue 11 31 
    Ring Blue-Red 12 6 
    7 Tip Red-Orange 13 
    32 
    Ring Orange-Red 14 7 
    8 Tip Red-Green 15 
    33 
    Ring Green-Red 16 8 
    9 Tip Red-Brown 17 
    34 
    Ring Brown-Red 18 9 
    10 Tip Red-Slate 19 
    35 
    Ring Slate-Red 20 10 
    DO NOT connect line 8 if the Door Answer Unit is being installed on the Panther II 820 system. 
    DO NOT connect line 10 if the Door Answer Unit is being installed on the Panther II IO32 system. 
    *Not required for the Panther II 820 system. 
    Table 6-l Pin-to-Pin Designations 
    (for Panther II 820/1032 KSU) 
    (RJ21X Connector) 
    Installation and Commissioning 
    Page 21  
    						