    Unit heat value 
     
    Spindle unit type Average heat value Stand by heat value 
    UEC-F024        About 26W       About 18W 
    UEC-F040        About 39W       About 18W 
    UEC-F120        About 74W       About 18W 
    UEC-F300M 
    (I/O) 
                        About 5.5W 
    UEC-F300M 
    (CC-LINK) 
                        About 5.5W 
    UEC-F300M 
    (D-NET) 
                        About 5.5W 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    ============================================================ 
         19  
    						
    							
    ======Chapter 4=============================================== 
    4-2 Power plug connections
     
    Use right bottom power socket to supply spindle unit with electricity. 
    Use accessory power cord which comes with spindle unit. 
    Protect spindle unit by circuit protector when power supply. 
     
     
     
     
     
          Connections 
     
          4: U 
          3: V 3-phase alternate current 
          2: W  AC-200~220V 
          1: FG 
    T/D
    MOTOR
    AC200-220V
    4:U 
    3:V CN 
      I/O 
    AC200V 
    2:W 
    1:FG
     
    UEC- 
    F024 
     
     
    URYU 
     
     
     
     
    Suitable plugs 
     Manufacturer  : AMP 
     Type   : D3200S Rise Housing 
     Number  : 1-178128-4 (keying X) 
     
     Type   : Rise contact (crimp type) 
     Number  : 1-175218-3 
     
    Recommended circuit protector 
    Spindle unit Circuit protector type (manufacturer : Izumi electric 
    UEC-F024 NRC210L-5A-AA 
    UEC-F040 NRC210L-7A-AA 
    UEC-F120 NRC210L-15A-AA 
       Note: Select delay action type. 
    Recommended trans capacity 
    Spindle unit Trans capacity 
    UEC-F024 0.2KVA~0.3KVA  X  Spindle numbers 
    UEC-F040 0.6KVA~1.0KVA  X  Spindle numbers 
    UEC-F120 3.0KVA~6.0KVA  X  Spindle numbers 
    ============================================================ 
         20  
    						
    							
    ==========================================Chapter 4=========== 
    4-3 External control signal wiring
    4-3-1 AXIX I/O signals  When main operation is under setting. 
    NO Signals IN/OUT Contents 
    1   
    2   
    3   
    4   
    Do not use. 
    5 BYPASS IN    NO Select non-operation 
    6  
    7  
     Do not use. 
    8   Do not use. 
    9   
    10   
    Do not use. 
    11 SENSOR IN    NO Proximity sensor connection for pin hole control
    12   Do not use. 
    13 IN COMMON  Common for input signals, connect +12~24V 
    14   Do not use. 
    15 BANK SELECT 1 IN    NO 
    16 BANK SELECT 0 IN    NO 
    Change data OUT DATA 0-11 contents. 
    17   
    18   
    19   
    Do not use. 
    20 CCW IN    NO Change rotating direction.  Use for left thread 
    or tools’ front has an extra gear. 
    21   Do not use. 
    22 OUT DATA 11 OUT  NO Output system status as per BANK SELECT 
    signal. 
    23 OUT COMMON  Common for output signals, connect 0V. 
    24 OUT DATA 7 OUT  NO 
    25 DATA OUT 6 OUT  NO 
    26 DATA OUT 5 OUT  NO 
    27 DATA OUT 4 OUT  NO 
    28 DATA OUT 3 OUT  NO 
    29 DATA OUT 2 OUT  NO 
    30 DATA OUT 1 OUT  NO 
    31 DATA OUT 0 OUT  NO 
    32 DATA OUT 10 OUT  NO 
    33 DATA OUT 9 OUT  NO 
    34 DATA OUT 8 OUT  NO 
    Output system status as per BANK SELECT 
    signal. 
    IN: Input signal   OUT: Output signal NC: Normal close  NO: Normal open 
     
     
    Suitable plugs 
    Manufacturer: Honda communication industry (HONDA) 
    Name :Multipolar connector small Vertical case 
    Type :MR-34M, MR-34L 
     
     
     
     
    =========================================================== 
         21  
    						
    							
    ======Chapter 4=============================================== 
    4-3-2 AXIS I/O OUT DATA signals
    AXIS I/O BANK SELECT table 
    Pin No. Signals IN/OUT Contents 
    16 
    15 
    BANK SELECT 0 
    BANK SELECT 1 
    IN   NO 
    IN   NO 
    Change OUT DATA 0-11 contents. 
     
    OUT DATA  BANK 
    SEL.0 
    Pin16 
    BANK 
    SEL.1 
    Pin15 Pin 
    No. 
    Signal 
    Contents 
    31 OUT DATA0 NOK Result was NOK. 
    30 OUT DATA1 OK Result was OK. 
    29 OUT DATA2 READY Unit is ready. 
    28 OUT DATA3 HIGH NOK Judgment was high. 
    27 OUT DATA4 LOW NOK Judgment was low. 
    26 OUT DATA5 TQ.HIGH.NOK Torque exceeded upper limit. 
    25 OUT DATA6 TQ.LOW.NOK Torque not exceeded low limit. 
    24 OUT DATA7 BYPASS Non-operation status 
    34 OUT DATA8 NOK CODE 0 
    33 OUT DATA 9 NOK CODE 1 
    32 OUT DATA10 NOK CODE 2 
    B 
    A 
    N 
    K 
    1 
     
     
     
     
     
     
    OFF 
     
     
     
     
     
     
     
     
    OFF 
     
    22 OUT DATA11 NOK CODE 3 
    Output NOK contents by 4 codes. 
    31 OUT DATA0 TIME 1 NOK 1st tightening not completed in preset 
    time. 
    30 OUT DATA1 TIME 2 NOK Final tightening not completed in preset 
    time. 
    29 OUT DATA2 PRAM.SELECT0 
    28 OUT DATA3 PRAM.SELECT1 
    27 OUT DATA4 PRAM.SELECT2 
    26 OUT DATA5 PRAM.SELECT3 
    25 OUT DATA6 PRAM.SELECT4 
    24 OUT DATA7 PRAM.SELECT5 
    Output designated parameter numbers. 
    34 OUT DATA8 Not used  
    33 OUT DATA 9 Not used  
    32 OUT DATA10 Signal 1 Signal between main unit. 
    B 
    A 
    N 
    K 
    2 
     
     
    ON 
     
     
     
     
    OFF 
     
    22 OUT DATA11 Signal 2 Signal between main unit. 
    31 OUT DATA0 NOK Result was NOK. 
    30 OUT DATA1 OK Result was OK. 
    29 OUT DATA2 READY Unit is ready. 
    28 OUT DATA3 ALARM System is giving errors. 
    27 OUT DATA4 BUSY Tightening is in operation. 
    26 OUT DATA5 ANG.HIGH.NOK Turning angles exceeded upper limit. 
    25 OUT DATA6 ANG.LOW.NOK Turning angles not exceeded low limit. 
    24 OUT DATA7 BYPASS Non-operation status 
    34 OUT DATA8 Not used  
    33 OUT DATA 9 Not used  
    32 OUT DATA10 Not used  
    B 
    A 
    N 
    K 
    3 
     
     
     
     
     
     
     
     
    OFF 
     
     
     
     
     
     
     
     
    ON 
     
    22 OUT DATA11 Not used  
    31 OUT DATA0 ALARM SUB 0 
    30 OUT DATA1 ALARM SUB 1 
    29 OUT DATA2 ALARM SUB 2 
    28 OUT DATA3 ALARM SUB 3 
    Alarm sub numbers: 
    Output detailed code by 4 bit when 
    alarm is provided. 
    27 OUT DATA4 ALARM CODE0 
    26 OUT DATA5 ALARM CODE1 
    25 OUT DATA6 ALARM CODE2 
    24 OUT DATA7 ALARM CODE3 
    Alarm sub numbers: 
    Output code by 4 bit when alarm is 
    provided. 
    34 OUT DATA8 Not used  
    33 OUT DATA 9 Not used  
    32 OUT DATA10 Not used  
    B 
    A 
    N 
    K 
    4 
     
     
     
     
     
     
    ON 
     
     
     
     
     
     
     
     
     
    ON 
     
     
     
     
    22 OUT DATA11 Not used  
    *Not in action 
    When 
    nutrunner is 
    in in use. 
    ============================================================ 
         22  
    						
    							
    ==========================================Chapter 4=========== 
    Upper limit: Value greater than standard upper limit  NOK 
      Value less than standard upper limit  OK 
    Low limit Value greater than standard low limit  OK 
      Value less than standard low limit  NOK 
     
    NOK< Standard low limit≦OK
    						
    							
    ======Chapter 4=============================================== 
    4-3-4  Input output signals 
    (1) Input signals 
    Providing input terminals with LOW (0V)  will change spindle unit to “ON” status. 
     
    1. BYPASS:  Non-operation signal 
    While this signal is being switched “ON”, spindle unit becomes 
    non-operation status and does not  start tightening with providing 
    BYPASS signal. 
    Tightening operation will be suspended  when spindle unit  becomes 
    non-operation status whil e in tightening operation. 
      2. BANK SELECT 0, 1:  Output signal bank select signal 
    Option of bank numbers 1~4 will change contents of 12 output signals. 
    Combination of BANK SELECT 0 and BANK SELECT 1 signals will make 
    following output signal change possible. 
     
    BANK SELECT 1 BANK SELECT 0 OUTPUT BANK 
      OFF (OPEN) OFF (OPEN)       1 
      OFF (OPEN)       ON       2 
          ON OFF (OPEN)       3 
          ON       ON       4 
    (2) Output signals 
    Electric pressure of output terminals get s the same level as output common (0V) 
    when output signals are switched “ON”.    Output signals (OUT0~OUT11) will have 
    the following meanings (output banks) due  to BANK SELECT signals combination. 
      
          ON: Connected with 0V. 
    OFF: Input common (HIGH) level or open. 
     
    BANK1         BANK2           BANK3 
    BANK SEL.0 
    (Pin No.16) 
    OFF ON OFF ON  
     
    Pin 
    No 
    BANK SEL.1 
    (Pin NO.15) 
    OFF OFF ON ON 
    31 OUT DATA 0 NOK TIME 1 NOK NOK ALARM SUB 0 
    30 OUT DATA 1 OK TIME 2 NOK OK ALARM SUB 1 
    29 OUT DATA 2 READY PRAM.SELECT0 READY ALARM SUB 2 
    28 OUT DATA 3 HIGH NOK PRAM.SELECT1 ALARM ALARM SUB 3 
    27 OUT DATA 4 LOW NOK PRAM.SELECT2 BUSY ALARM CODE 0 
    26 OUT DATA 5 TQ.HIGH NOK PRAM.SELEC T3 ANG.HIGH NOK ALARM CODE 1 
    25 OUT DATA 6 TQ.LOW NOK PRAM.SELECT4 ANG.LOW NOK ALARM CODE 2 
    24 OUT DATA 7 BYPASS PRAM.SELECT5 BYPASS ALARM CODE 3 
    34 OUT DATA 8 NOK CODE0 Not used Not used Not used 
    33 OUT DATA 9 NOK CODE1 Not used Not used Not used 
    32 OUT DATA 10 NOK CODE2 SIGNAL 1 Not used Not used 
    22 OUT DATA 11 NOK CODE3 SIGNAL 2 Not used Not used 
     
    ※ Bank 2 is not in use when multiple spindles are in operation. 
     
     
     
     
    ================================ ============================ 
         24  
    						
    							
    ==========================================Chapter 4=========== 
    Output bank 1 
    (DATA 0) NOK: Tightening NOK signal (when completed with NOK) 
    This is output when tightening result of spindle unit completed out of preset range. 
     
    (DATA 1) OK: Tightening OK signal (when completed with OK) 
    This is output when tightening result of  spindle unit completed normally within 
    preset range. 
     
    (DATA 2) READY: Input permission signal 
    This is output when spindle unit is prepar ed to give operation (tightening, reverse 
    or etc) as per input signals provided by  external equipment such as sequencer. 
     
      READY signal will be switched OFF under the following conditions. 
     ○  Under initial processing for  a few seconds when switched on. 
     ○  Error signal output 
     ○  Non-operation status (under setting, download or etc.) 
     ○  When not in use 
     ○  Under reset processing 
    ○ Others when spindle unit is unable to meet external input 
     
    (DATA 3) HIGH NOK: Upper limit NOK 
    This is output when tightening comple ted with torque or angle exceeded upper 
    limit, or initial NOK/ cycle NOK detected. 
     
    (DATA4) LOW NOK: Low limit NOK 
    This is output when tightening completed  with torque or angle under low limit, or 
    initial NOK/cycle NOK detected. 
     
    (DATA5) TQ HIGH NOK: Torque upper limit NOK 
    This is output when tightening complet ed with peak torque or final torque 
    exceeded upper limit. 
     
    (DATA6) TQ LOW NOK: Torque low limit NOK 
    This is output when tightening completed  with peak torque or final torque under 
    low limit. 
     
    (DATA7) BYPASS: non-operation status 
      This is output when spindle unit is non-operation status. 
     
    (DATA8-11) NOK CODE 0~3: NOK cont ents will be output via 4 points code. 
     
    NOK 
    CODE0 
    NOK 
    CODE1 
    NOK 
    CODE2 
    NOK 
    CODE3 
    Pin 34 Pin 33 Pin 32 Pin 22 
    Contents 
    ON OFF OFF OFF Alarm (refer to bank4 for the details. 
    OFF ON OFF OFF Initial timer NOK 
    ON ON OFF OFF Cycle timer NOK 
    OFF OFF ON OFF Snug torque NOK 
    ON OFF ON OFF Fit-in upper torque NOK 
    OFF ON ON OFF Fit-in incline NOK 
    ON ON ON OFF Plastic area angle incline NOK 
    OFF OFF OFF ON Concurrent turning NOK 
    ON OFF OFF ON Angle upper limit NOK 
    OFF ON OFF ON Angle low limit NOK 
     
     
    ================================ ============================ 
         25  
    						
    							
    ======Chapter 4=============================================== 
    Output bank 2 (Not applicable when  multiple spindles are in use) 
    (DATA0) Time 1 NOK: Time over of 1st area (not used yet) 
    This is output when tightening of spindle unit fails to reach 1st torque or 1st angle 
    before time of 1st timer is over.    This is also  output when tightening of spindle unit 
    reaches 1st torque or 1st angle within preset minimu m tightening time.    Use this 
    function for “No bolt” or “No work” detection. 
     
    (DATA1) Time 2 NOK: Time over of final tightening area (not used yet) 
    This is output when spindle unit running time from 1st torque or 1st angle got longer 
    than final time before tightening torque reac hes cut torque or cut angle.    This is 
    also output when spindle unit running time to reach cut torque or cut angle was 
    shorter than preset minimum tightening time. 
     
    (DATA2-7) PRAM.SELECT 0-5: 
    Outputs designated parameter numbers. 
     
    (DATA10-11) SIGNAL 1-2:     
      Signals amongst spindle units 
     
    Output bank 3 
    (DATA0) NOK: Tightening NOK signal (NOK end) 
    This is output when spindle unit tighteni ng completion ended with result out of 
    preset range. 
     
    (DATA1) OK: Tightening OK signal (Normal completion) 
    This is output when spindle unit tighteni ng ended normally within preset range. 
     
    (DATA2) READY: Input permission signal 
    This is output when spindle unit is prepar ed to give operation (tightening, reverse 
    or etc) as per input signals provided by  external equipment such as sequencer. 
     
    READY signal will be switched OFF under the following conditions. 
    ○  Under initial processing for a few seconds when switched on. 
     ○  Error signal output 
    ○  Non-operation status (under setting, download or etc.) 
    ○  When not in use 
     ○  When reset processing 
     ○  Others when spindle unit is unable to meet external input 
     
    (DATA3) ALARM: System error signal (Abnormal completion) 
    This is output when spindle unit system che ck detects error, or spindle unit detects 
    error during tightening operation. 
     
    (DATA4) BUSY: In operation signal 
      This is out put while tightening is in process. 
     
    (DATA5) ANG.HIGH NOK: Angle upper limit NOK 
    This is output when tightening complet ed with tightening angles exceeded upper 
    limit. 
     
    (DATA6) ANG/LOW NK: Angle low limit NOK 
    This is output when tightening completed  with tightening angles not exceeded low 
    limit. 
     
    (DATA7) BYPASS: non-operation status 
      This is output when spindle unit is non-operation status. 
     
    ================================ ============================ 
         26  
    						
    							
    ==========================================Chapter 4=========== 
    Output bank 4 
    (DATA0~3) ALARM  SUB  0~3 
    Output detailed code when ALARM is provided.    4-bit will be provided. 
    (DATA4~7) ALARM CODE 0~3 
    Output detailed code when ALARM is provided.    4-bit will be provided. 
     
    Contents of errors shall be classified in  the following table.This is from 8-bit 
    combination of ALARM code and ALARM sub. 
     
    ALARM NUMBERS ALARM SUB NUMBERS ALARM CODE0 ALARM CODE1 ALARM CODE2 ALARM CODE3 ALARM CODE0 ALARM CODE1 ALARM CODE2 ALARM CODE3 Pin27 Pin26 Pin25 Pin24 Pin31 Pin30 Pin29 Pin28 
    CONTENTS 
    ON OFF OFF OFF OFF OFF OFF OFF (A1_0)ZERO POINT MASTER 
    ERROR 
    ON OFF OFF OFF ON OFF OFF OFF (A1_1)CAL ERROR 
    ON OFF OFF OFF OFF OFF ON OFF (A1_4)SWITCH ON UNDER 
    ZERO POINT MASTER ERROR ON OFF OFF OFF ON OFF ON OFF (A1_5)SWITCH ON UNDER CAL ERROR ON OFF OFF OFF OFF ON OFF ON (A1_6)ZERO POINT ERROR OFF ON OFF OFF ON OFF OFF OFF (A2_1) TORQUE OVER UNDER 
    TORQUE CUT ON ON OFF OFF ON OFF OFF OFF (A3_1)TOOL TYPE ERROR ON ON OFF OFF OFF ON OFF OFF (A3_2)START WITH NO TOOL  CONNECTED ON ON OFF OFF ON ON OFF OFF (A3_3)TOOL NOT CONNECTED 
    OFF OFF ON OFF OFF OFF OFF OFF (A4_0)F-ROM WRITING ERROR 
    OFF OFF ON OFF ON OFF OFF OFF (A4_1)F-ROM UPLOAD ERROR 
    OFF OFF ON OFF OFF ON OFF OFF (A4_2)F-ROM AMPLIFIER SIDE 
    ERROR 
    OFF ON ON OFF OFF OFF OFF OFF (A6_0)NON-SETTING OF SERVO 
    TYPE 
    OFF OFF OFF ON ON OFF OFF OFF (A8_1)SPINDLE UNIT OVER  –HEATING ERROR 
    OFF OFF OFF ON OFF OFF ON OFF (A8_4)OVER CURRENT 
    OFF OFF OFF ON ON OFF ON OFF (A8_5)OVER 
    VOLTAGE,INTERNAL POWER 
    PRESSURE ERROR
     
    OFF OFF OFF ON OFF ON ON OFF (A8_6)POWER  VOLTAGE PRESSURE ERROR 
    OFF OFF OFF ON ON OFF OFF ON (A8_9)OVER SPEED 
    OFF OFF OFF ON OFF ON OFF ON (A8_10)OVER LOAD 
    OFF OFF OFF ON ON ON OFF ON (A8_11)RESOLVER ERROR ON OFF OFF ON ON OFF OFF OFF (A9_1)SETTING ERROR ON OFF OFF ON OFF ON OFF OFF (A9_2)SYSTEM ERROR 1 ON OFF OFF ON ON OFF ON OFF (A9_5)SYSTEM ERROR 4 ON OFF OFF ON OFF ON ON OFF (A9_6)SYSTEM ERROR 5 ON OFF OFF ON ON ON ON OFF (A9_7)TORQUE LIMIT OVER 
     
     
     
     
     
     
     
     
     
    ================================ ============================ 
         27  
    						
    							
    ======Chapter 4=============================================== 
    4-4 Spindle unit number setting 
    Set spindle unit number from 1 when you use UEC-F300 system for multiple 
    nutrunners.  Make this setting from DIP (SW1) switch available in the front panel 
    of spindle unit. 
     
    Note: Keep DIP switch 1~3 OFF position for ordinary use. 
     
    DIP switch numbers 
    1  OFF: Multiple spindles specifications 
    ON: Single spindle specifications 
    2  OFF:Level start method 
    ON:One pulse start method (effective for 
    single specifications) 
    3  OFF:Smooth speed reduction to torque speed 
    ON:Quick speed reduction to torque speed 
     
    Remove optional display unit when your spindle 
    unit comes with optional display unit.  Open 2 
    screws available in the bottom of display unit.  
    Refer to chapter 8. 
     
     
     
     
     
     
    CON1 
    OFF ON 
    SW1 12POWER 345SP RUN 678M/D ALM 
    BYPASS ALARM 
    OK 
    RUN NOK 
    Spindle numbers setting table 
    DIP SWITCH NUMBERS SPNDLE 
    NUMBE
    RS 4 5 6 7 8 
    1 OFF OFF OFF OFF ON 
    2 OFF OFF OFF ON OFF 
    3 OFF OFF OFF ON ON 
    4 OFF OFF ON OFF OFF 
    5 OFF OFF ON OFF ON 
    6 OFF OFF ON ON OFF 
    7 OFF OFF ON ON ON 
    8 OFF ON OFF OFF OFF 
    9 OFF ON OFF OFF ON 
    10 OFF ON OFF ON OFF 
    11 OFF ON OFF ON ON 
    12 OFF ON ON OFF OFF 
    14 OFF ON ON ON OFF 
    15 OFF ON ON ON ON 
    16 ON OFF OFF OFF OFF 
    DIP SWITCH NUMBERS SPNDLE 
    NUMBE
    RS 4 5 6 7 8 
    17 ON OFF OFF OFF ON 
    18 ON OFF OFF ON OFF 
    19 ON OFF OFF ON ON 
    20 ON OFF ON OFF OFF 
    21 ON OFF ON OFF ON 
    22 ON OFF ON ON OFF 
    23 ON OFF ON ON ON 
    24 ON ON OFF OFF OFF 
    25 ON ON OFF OFF ON 
    26 ON ON OFF ON OFF 
    27 ON ON OFF ON ON 
    28 ON ON ON OFF OFF 
    29 ON ON ON OFF ON 
    30 ON ON ON ON OFF 
    31 ON ON ON ON ON 
     
    Note: Spindle number setting cannot be duplicated.  Make spindle number setting from 