Home > Alarm Lock > Alarm Lock > Alarm Lock DK3000 Programming Manual

Alarm Lock DK3000 Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Alarm Lock DK3000 Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							21 
    ; 3 8      ; [ _ _ _ _ _ _ ] :  
      
    (Date) 
    38. Set Date 
    •Use Month Day Year format - MMDDYY - Single digit months and days are entered with a preceding zero. 
    •Enter ONLY the last two digits of the year. 
     
    For Example: March 8, 2009; Enter:  
     ; 3 8      ; 0 3   0 8    0 9 : 
     3 
    39. Set Time ; 3 9      ; [ _ _ _ _ ] :  
      
    (Time) 
    •Time must be 4 digits 
    •Use 24 Hour Format (add 12 hours to program PM time) 
     
    For Example:  To set time to 8:25PM;  
     
     
     
    Enter: ; 3 9      ; 2 0 2 5 :  For Example:  To set time to 8:25AM;   
     
     
    Enter: ; 3 9      ; 0 8 2 5 : 
     3 
    ; 4 0      ; [ _ ] :  
      (Day) 40. Set Weekday 
    •For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday and 7 for Saturday.  For Example:  To set day to Sunday;   
     
     
    Enter: ; 4 0      ; 1 : 
     3 
    41. Daylight Saving Time Start Date ; 4 1 ; [ M M W D ] :  
    (DST Starting Month, Month, Week, Day) 
    The manner in which Daylight Saving Time (DST) is observed varies with location, therefore the DST adjustment is fully flexible to 
    accommodate these regional differences.  Function 41 allows the entry of a DST Start Date (month, day and week), and Function 42 
    allows the entry of a DST End Date (month, day and week).  DST begins and ends at 2AM on the programmed date.  Enter ; 
    4 1 ; 0 0 0 : to disable DST.  All locks leave the factory with DST enabled and pre-programmed to the 
    following start and end dates (for the USA beginning 2007): 
     
    •Default DST Start Date: March, Week 2, Sunday (Second Sunday in March) 
    •Default DST End Date:   November, Week 1, Sunday (First Sunday in November)  To program the DST start date using the keypad, press:  ; 4 1 ; [ M M W D ] : where M M W D represents:  
    •M M = Two digits of the month (01 through 12 = January through December.  Single digit months are entered with a 
    preceding zero). 
    •W = Single digit for week of the month (valid entries are 1-5 where 1 is the first week, 2 is the second week, 3 is the 
    third week, 4 is the fourth week and 5 is the last week of the month. 
    •D = Day of the week (valid entries are 1-7:  1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 
    for Friday and 7 for Saturday).   
     Example:  To set the default start date of second Sunday in March, press:  
                    ; 4 1 ; [ 0 3 2 1 ] : (03 = March,  2 = 2nd week, 1 = Sunday). 
     4 
    CLOCK SETTINGS 
    Programming Functions (contd) 
    42. Daylight Saving Time End Date ; 4 2 ; [ M M W D ] :  
    (DST Ending Month, Month, Week, Day) 
    End date of Daylight Saving Time (month, week, day).  Enter ; 4 2 ; 0 0 0 : to disable DST.  
    See Function 41 for full explanation.  4  
    						
    							22 
    ; 4 3           ; [ _  _ ] :  
    (seconds) 
    43. Speed Up Clock (This Function enabled through keypad only) 
    ; 4 4           ; [ _  _ ] :  
    (seconds) 
    44. Slow Down Clock (This Function enabled through keypad only) 
    ; 4 5 : 45. Enable Passage Mode (This Function enabled through keypad only) 
    ; 4 6 : 46. Disable Passage Mode (This Function enabled through keypad only) 
    47. Timed Passage Mode (This Function enabled through keypad only) 
    ; 4 7      ; [ _ _ _ ] :  
    (XXX Hours) 
    •Function 45 allows passage through the door without the need for a User Code.  Re-Lock using Function 46.   
    •Programmed Schedules will override the state of the lock when Functions 45 and 46 are used.  If it is required that 
    programmed schedules do not override Passage Mode, enable/disable Passage Mode using Functions 48/49.  Note:  Be-
    cause of the temporary nature of these features, Functions 45-47 can only be enabled using the keypad. 
    Passage Mode Enable/Disable - Schedule will Override  
     2 
    •Hours must be between 1 - 999. Function 47 allows passage through the door without the need for a User Code for the programmed amount of time.  
     
     
     
    •For example, if you wish your office door lock to be unlocked (unlocked = Passage Mode) for the next 3 hours, 
    enter Program Mode and press:  ; 47 ; 003 :     
     2 
    PASSAGE MODE 
    CLOCK ADJUST 
    Number of seconds to adjust (speed up/slow down) the clock each day must be be-
    tween 0-55 seconds. 
    Note:  Repeated use of these Functions are not cumulative (this means, for example, 
    if the clock has already been set to speed up 10 seconds per day, and then is found to 
    need an additional 10 seconds, then program 20 seconds using Function 43). 
     
    Example 1:  Clock is losing 13 seconds every day, enter: 
     ; 4 3       ; 1 3 :.  
    This example assumes that the Clock Adjust setting was at the factory default of zero.  
    Function 57 can be used to print the current Clock Adjust setting. 
     
    Example 2:  Clock is gaining 13 seconds every day, enter: 
     ; 4 4       ; 1 3 :.  
    This example assumes that the Clock Adjust setting was at the factory default of zero. 
    Function 57 can be used to print the current Clock Adjust setting. 
     
    Example 3:  To set the clock adjust setting back to the factory default of zero, enter
    :  ; 4 3 :  or ; 4 4 : 
    Clock Adjust  
     4 
    Programming Functions (contd) 
    Clock Accuracy 
    The internal oscillator is factory calibrated to an accu-
    racy of ±5 minutes/year.  Changes in ambient tem-
    perature may affect accuracy.  If necessary, the ac-
    curacy of the internal clock may be adjusted by first up-
    dating the correct time via Function 39.  After an interval 
    of about 1 month, re-set the correct time via Function 39 
    and then print an Audit Log via Function 55.  Because 
    the Audit Log displays both the New Clock Time and 
    the Old Clock Time, a daily accuracy (in seconds) can 
    be determined by taking the difference in seconds be-
    tween the Old and New times divided by the number 
    of days between the two Function 39 entries.  Note:  
    Because the minimum available adjustment is 1 second 
    per day, the inaccuracy of the clock must exceed about 6 
    minutes per year before adjustment is necessary.  
    						
    							23 
    49. Disable Permanent Passage Mode (This Function enabled through keypad only) 
    50. Return Lock to Normal Passage 
    Mode Schedule 
    (This Function enabled through keypad only) (Locks will lock or unlock depending on the current schedule).  Use Function 50 to undo Functions 48 and/
    or 49, and therefore return the lock to all pre-existing scheduled functions. 
    •Function 48 allows passage through the door without the need for a User Code.  Re-Lock using Function 49. 
    •Programmed Schedules will not override the state of the lock using functions 48 and 49.  If it is required that programmed 
    schedules override Passage Mode, Enable/Disable Passage Mode using Functions 45/46.  Use Function 50 to undo Func-
    tions 48 and/or 49, and therefore return the lock to all pre-existing scheduled functions.  Note:  Functions 48-50 can only be 
    enabled using the keypad.  Warning:  Function 49 will inhibit all scheduled Passage Mode events. 
    Passage Mode Enable/Disable - Schedule will not Override 
     2 
    PERMANENT PASSAGE MODE 
    ; 4 9 :  
    48. Enable Permanent Passage Mode (This Function enabled through keypad only)  
    ; 4 8 :  
    ; 5 0 :  
    ; 5 2 : 52. Set Pass Time to 3 Sec.        
    ; 5 3 : 
    ; 5 4 : 
    The Pass Time is the length of time the lock stays unlocked after a valid User Code is 
    entered.  When the Pass Time expires, the lock will re-lock automatically.  Use the 
    functions below to change the Pass Time to 3, 10 or 15 seconds.  The Pass Time is 
    defaulted to 3 seconds.   
    Pass Time 
     4 
    53. Set Pass Time to 10 Sec.        
    54. Set Pass Time to 15 Sec.        
    PASS TIME 
    See Scheduled functions 72 and 73 for Scheduled Passage Mode. NOTE:  
    Programming Functions (contd) 
    51. Passage Mode Configuration  ; 5 1 ;     [ _ ]    : 
    (Mode)  
    •Mode 1 (Normal):  Passage Mode must be enabled/disabled using Function 45 and 46.  Mode 1 (Normal) is the factory de-
    fault. 
    •Mode 2:  Group 2 toggles Passage Mode. 
    •Mode 3:  Group 2 enables, Group 3 disables Passage Mode.  Disable Passage Mode has priority if User is a member of both 
    Groups 2 and 3. 
     
     
     
         With Mode 2, each time any member of Group 2 enters their User Code, they will toggle Passage Mode.  For example, if Pas-
    sage Mode is enabled, and a Group 2 User enters their User Code, Passage Mode will be disabled.  If a few seconds later they 
    enter their User Code again, Passage Mode will be enabled.  With Mode 3, Group 2 members will always enable Passage Mode, 
    and Group 3 members will always disable Passage Mode.  For example, if Passage Mode is already enabled, and a Group 2 
    User enters their User Code, the Passage Mode status will not be changed due to the Function 51 Mode 3 configuration.  If Pas-
    sage Mode is already enabled, and a Group 3 User enters their User Code, Passage Mode will become disabled. 
     4  
    						
    							24 
    ; 5 5 : 
    ; 5 7 :  57. Print Clock Settings, Software 
    Version and Door Number
      
    55. Print Audit Trail  
    ; 5 6 :  56. Print User Code List  
    ; 5 8 : 58. Upload/Download PC Data 
    Hold the printer over the locks infrared sensor as shown in Figure 1 and Figure 2 above.  
    Twenty (20) events will print at a time; press 1 for more events, or 9 to quit.  To abort 
    printing, press any key for 3 seconds (three short beeps will sound). 
    Hold the printer over the locks infrared sensor as shown in Figure 1 and Figure 2 above.  
    To abort printing, press any key for 3 seconds (three short beeps will sound). 
    Hold the printer over the locks infrared sensor as shown in Figure 1 and Figure 2 above. 
    For use with DL-WINDOWS software, refer to OI237.  AL-PCI interface cable is needed. 
     1 
     3 
     3 
    PRINTER 
    DOWNLOADING 
    Hold the printer perpendicular to the Lock’s infrared LED as shown in Figure 1 and Figure 2.  If the 
    printer has been idle for some time, press the paper feed button to wake up the printer. 
     1 
    Programming Functions (contd) 
    Infrared 
    LED 
    Figure 2 
    Infrared 
    LED 
    Infrared 
    Reader 
    Place Infrared Reader (on printer) in 
    front of the Infrared LED (on lock) 
    Figure 1 
    DK3000 to Printer  
    - Side View  
    						
    							25 
    ; 6 4 :  64. Disable Remote Input 
    •Wire a Normally Open Contact to Wires (White & White) for a Remote Input.  Momentarily close 
    switch to unlock the lock to allow person to pass through door.  This Remote Input can be used to 
    control the Aux Relay.  See the Aux Relay System Features on page 26 (Function 67). 
    •Enter the functions below to Disable/Enable the Remote Input.   
    NOTE:  The Remote Input is enabled in the factory default. 
    Remote Input  
    ; 6 5 : 65. Enable Remote Input 
     2 
    REMOTE INPUT 
    62-63. Reserved 
    60. Number of Attempts Before Lockout  
    61. Set the Attempts Lockout Time 
    Used with Function 61 
    •Number of attempts before lockout must be 1-9 attempts. 
    •The number of attempts is reduced by half every time the keypad is locked out without a 
    successful code entry (default is 6 attempts).   
    •The attempt count is reset each time a valid code is entered. 
    Function 61 determines the length of time the keypad is locked-out after a series of 
    unsuccessful attempts (default is 15 seconds).  Used with Function 60. 
    •Lockout Time must be 1-60 seconds. 
     4 
     4 
    LOCKOUT 
    ; 6 6      ; [ _  _ ] :  
    (Ambush Code) 
    66. Ambush Code 
    •Ambush code must be 2 digits. 
    •An error will sound if the Ambush Code matches the 1st two digits of any User Code.  
    See Function 67 for more information about the Ambush Function. 
    •Factory default Ambush Code is 99. 
     3 
    AMBUSH 
    ; 6 0      ; [ _ ] :  
    (Number of Attempts) 
    ; 6 1     ; [ _ _ ] :  
    (Lockout Time) 
    Programming Functions (contd) 
    59. Reserved  
    						
    							26 
     
    ; 6 7    ; [ _ _ ] : 
            (Event Number) 67. Add System Features 
    SYSTEM FEATURES 
    68. Delete All Relay Features added by Function 67.   ; 6 8   ; 0 0 0 : 
    •Aux Relay Features (12-24. Reserved)  
    1.      Remote Input switch closed and Function 65 Remote Input enabled.  
    Because the Remote Input is enabled by factory default, the Main Relay will 
    energize when the Remote Input switch is closed.  Additionally, if this event (#1) 
    is then programmed, the Aux Relay will also close for 2 seconds upon closure 
    of the Remote Input switch.   7.     Scheduled Lock Event.  Aux Relay energizes for 2 seconds when lock is 
    locked by a Schedule. 
    2.      Remote Input switch closed and Function 64 Remote Input disabled.  If 
    the Remote Input is disabled with Function 64, the Main Relay will NOT ener-
    gize when the Remote Input Switch is closed.  Additionally, if this event (#2) is 
    then programmed, the Aux Relay will close for 2 seconds upon closure of the 
    Remote Input switch.  The Main Relay will not energize. 8.     Scheduled Unlock Event.  Aux Relay energizes for 2 seconds when lock is 
    unlocked by a schedule 
    3.      Failed attempted entry.  Aux Relay energizes for 2 seconds when an at-
    tempted User Code entry via the keypad fails. 9.     Lock Out.  Aux Relay energizes for 2 seconds when a Lock Out occurs (i.e. 
    number of attempts is exceeded, see Function 60). 
    4.     Disabled User or Group.  Aux Relay energizes for 2 seconds when a disabled 
    User or disabled Group member enters a User Code. 10.    Ambush.  Aux Relay energizes for 2 seconds when Ambush is tripped.  See 
    Function 66, page 25. 
    5.     Follow Main/Entry Relay--Momentary Only.  When the Main/Entry Relay 
    energizes for any length of time, the Aux Relay energizes for only 2 seconds.  
    (Note:  The Aux relay will NOT energize with the Remote Input).  Compare with 
    Event 31. 11.    First Key Press.  Aux Relay energizes for 2 seconds at the first key press of 
    any sequence. 
    6.      Group 1 User Code.  Aux Relay energizes for 2 seconds when a scheduled 
    Group 1 User Code is entered.  See Function 90, page 29. 31.    Follow Access Granted--No Time Limit.**  When the Main/Entry relay ener-
    gizes for any length of time (such as a valid User Code entered or Remote 
    Input), the Aux Relay energizes for the same amount of time as the pro-
    grammed Pass Time.  (The Pass Time is the length of time the lock 
    stays unlocked after a valid User Code is entered.  See functions 52-
    5 4 ).   Use this feature for remote monitoring or other activation as this feature 
    works independently of all other relay options.  Programming this feature will 
    supersede all other programmed relay features.  Subsequent relay feature 
    programming will not take effect while this feature is active.  Before program-
    ming any other relay features, press ; 6 8 ; 0 0 
    0 : to delete this feature.  
    Use Function 67 to program one or more lock events and the Aux Relay will energize when the programmed event(s) listed below 
    occurs.  For example, program ; 6 7 ; 3 : and when an attempted entry fails (such as a User who enters 
    an incorrect or un-programmed User Code), the Aux Relay will energize for 2 seconds.  Note:  For more information about the Re-
    mote Input, see page 11 (Wiring, Remote Input) and page 25 (Function 65).  
     
     4 
    •System Options  
    25.  Disable Sounder 
    26.  5 sec. Delayed Entry * 
    27.  15 sec. Delayed Entry * 
    28.  45 sec. Delayed Entry * 
    •Remote Input Functions 
    29. Toggle Passage Mode.  Remote Input toggles Passage 
    Mode.  Passage Mode enabled = Main/Entry Relay energized. 
    30. Forced Unlock Follows Remote Input.**  When Remote 
    Input activated, the Main/Entry Relay will energize regardless 
    of its current state. 
    32. Remote Input Disables Unit.**  Regardless of the current 
    state, that state will remain unchanged (and keypad will be 
    disabled) for the duration of Remote Input switch closure. 
    *  Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299). 
    ** Sustained closure of remote input may affect proper audit trail operation. 
    NOTE:  Enter ; 6 7 ; 0 0 0 : to delete all Relay Features added by Function 67 (identical to Function 68).
     
    •PC Communication Functions 
    33.  Remote Input Puts Unit in PC Communication Mode 
    Enter ; 6 8   ; 0 0 0 : to delete all Relay Features added by Function 67.    4 
    Programming Functions (contd) 
    Ambush Function 1.  Connect relay to a device able to properly monitor dry contacts for an Ambush condition. 
    2.  Program the Relay for Ambush Tripped using Program Function 67(10) above. 
    3.  Set the Ambush Code using Program Function 66.  
    4.  W hen the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds. 
    Notes:  The Ambush Code defaults to 99.  An error will sound if you try to program a new User Code starting with the Ambush Code.  
    						
    							27 
    Scheduled Passage and Group 
    Use the functions below to enable Passage Mode and enable/disable Groups at the time programmed. 
    •For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week. 
    SCHEDULES 
    74. Schedule Enable Group 1 ; 7 4      ; [ _ ]           ; [ _ _ _ _ ] : 
                                             (Day)                                (Time) 
    75. Schedule Enable Group 2 ; 7 5      ; [ _ ]           ; [ _ _ _ _ ] : 
    (Day)                                (Time) 
    76. Schedule Enable Group 3 ; 7 6      ; [ _ ]           ; [ _ _ _ _ ] : 
                                             (Day)                                (Time) 
    77. Schedule Enable Group 4 ; 7 7      ; [ _ ]           ; [ _ _ _ _ ] : 
                                             (Day)                                (Time) 
    78. Schedule Enable All Groups ; 7 8      ; [ _ ]           ; [ _ _ _ _ ] : 
                                       (Day)                                (Time) 
    79. Schedule Disable Group 1 ; 7 9      ; [ _ ]           ; [ _ _ _ _ ] : 
                                       (Day)                                (Time) 
    80. Schedule Disable Group 2 ; 8 0      ; [ _ ]           ; [ _ _ _ _ ] : 
                                       (Day)                                (Time) 
    81. Schedule Disable Group 3 ; 8 1      ; [ _ ]           ; [ _ _ _ _ ] : 
                                       (Day)                                (Time) 
    82. Schedule Disable Group 4 ; 8 2      ; [ _ ]           ; [ _ _ _ _ ] : 
                                       (Day)                                (Time) 
    83. Schedule Disable All Groups ; 8 3      ; [ _ ]           ; [ _ _ _ _ ] : 
                                             (Day)                                (Time) 
     3 
    Clear All Schedule and Timeout Functions by entering Function 12. 
      To set the time, see Function 39.   NOTE:  
    72. Schedule Enable Passage 
    Mode (Unlock)
     
    ; 7 2      ; [ _ ]           ; [ _ _ _ _ ] : 
    (Day)                              (Time) 
    73. Schedule Disable Passage 
    Mode (Lock)
     
    ; 7 3      ; [ _ ]           ; [ _ _ _ _ ] : 
    (Day)                              (Time) 
    Groups 
    ENTER KEY 
    •When this function is enabled, the User must press : after any valid User Code entry.  Therefore, 
    this Function allows User Codes to be subsets of other User Codes. 
     Examples:   1 2 3 : can be a valid user code;  
    1 2 3 4 : can be a valid user code within the same lock. 
    1 2 3 4 5 6 :
     (Hold ;) for Master User Code to enter Program Mode. 
    Enter Key  
     4
     
    71. Reserved 
    Passage 
    Mode 
    69. Enable : as Enter Key  
    70. Disable : as Enter Key 
    Programming Functions (contd) 
    ; 6 9 : 
     
    ; 7 0
     :  
    						
    							28 
    QUICK SCHEDULES 
    84. Business Quick Schedule 
    7AM-5PM, Monday - Friday (This Function enabled through keypad only) 
    ; 8 4      ; [ _ ] :  
    (Group)  
    ; 8 5      ; [ _ ] :  
    (Group)  85. Day Quick Schedule  
    7AM-5PM, All days (This Function enabled through keypad only) 
    ; 8 6      ; [ _ ] :  
    (Group)  86. Evening Quick Schedule 
    3PM-1AM, All days (This Function enabled through keypad only) 
    ; 8 7      ; [ _ ] :  
    (Group)  87. Night Quick Schedule 
    11PM-9AM, All days (This Function enabled through keypad only) 
    88. Passage Mode  
    (Open Time Window)
     
    (This Function enabled through keypad only) 
    ; 8 8      ; [ _ ]           ; [ _ _ _ _ ] : 
                                              (Day)                                      (Time) 
    Functions 88 and 89 allow you to set up a window of time where if any Group 1 User Code is entered within this window, 
    Passage Mode will be activated, allowing anyone to enter.  Note:  This feature can only be programmed using the lock key-
    pad.  For additional information, see Group 1 Activated Features on page 31. 
     
    •For the day enter: 1 for Sunday
    , 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week.  •Enter time of day in 24 hour format (for example, for 2:15 PM, enter 14:15). 
    Note:  Do not use this feature in Residency mode. 
    Scheduled Passage Mode (Group 1 Activated)  
    89. Passage Mode 
    (Close Time Window)
     (This Function enabled through keypad only) 
    ; 8 9      ; [ _ ]           ; [ _ _ _ _ ] : 
                                              (Day)                                       (Time) 
    SCHEDULES GROUP 1 ACTIVATED 
     3 
    For your convenience, your lock comes pre-programmed with Quick Schedules, which, when programmed, enable Groups for 
    popular blocks of time.  Group members will be enabled during the blocks of time defined below, but will still need to enter their 
    User Codes into the keypad to unlock the lock.   
    •Group number must be 1-4; enter the number of the Group that is to be enabled for the time specified by the Quick 
    Schedules below. 
     Note:  These Quick Schedules can only be programmed through the keypad (not through DL-Windows), and existing Quick 
    Schedules will be over-written by schedules downloaded from DL-Windows.  Therefore, after downloading any DL-Windows 
    schedules, be sure to re-program your Quick Schedules into your Lock Program. 
     3 
    Quick Schedules - Enable Group 
    Programming Functions (contd)  
    						
    							29 
    To Disarm a Burglary Control Panel 
    90. Relay Activation  
    (Open Time Window)
     
    ; 9 0      ; [ _ ]           ; [ _ _ _ _ ] : 
                                              (Day)                                      (Time) 
    Functions 90 and 91 allow you to set up a window of time where if any Group 1 User Code is entered within this window, 
    the relay will be activated for 2 seconds.  This relay is for use with a Control Panel that has a key switch disarm option.  For 
    additional information, see Group 1 Activated Features on page 31. 
     
    •Also program Relay Function 6 using Function 67 (; 6 7      ; 6 :). 
    •For day enter: 1 for Sunday
    , 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 
    8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week. 
    •Enter time of day in 24 hour format (for example, for 2:15 PM, enter 14:15). 
    Scheduled Relay Activation (Group 1 Activated)  
    ; 9 1      ; [ _ ]           ; [ _ _ _ _ ] : 
                                              (Day)                                       (Time) 
    91. Relay Activation  
    (Close Time Window)
     
    SCHEDULES GROUP 1 ACTIVATED 
     3 
    NOTES  1.  Group 1 Disarms a Burglary Control 
    Panel will always disarm an alarm 
    system.  Arming should be performed 
    by other means (such as Alarm Panel 
    Keypad/Schedule). 
     
    2.  Use a qualified electrical/alarm 
    specialist to review your current alarm 
    system and add additional components 
    as needed (such as a relay, wire, 
    resistors, connectors and/or diodes) and 
    re-program the operation of your alarm 
    system as needed. 
    Programming Functions (contd) 
    Alarm Panel with Switched Input for Disarming 
    Alarm Panel with Switched Input for Toggled Arm/Disarm 
    Burglary 
    Control 
    Panel 
    Switch  
    Input Relay  
    Output 
    Burglary 
    Control 
    Panel Switch  
    Input Relay  
    Output 
     
    Armed 
    Lug Power  
    						
    							30 
    ; 9 9      ; 0 0 0 :  99. Clear All Lock Programming (This Function enabled through keypad only) 
    Clears all programming, and returns lock to factory default settings.  Audit Trail contents 
    are maintained.  (See Glossary for definition of default settings).  M 
    CLEAR ALL PROGRAMMING 
    94 - 98. Reserved 
    92. Enable Group 4  
    (Open Time Window) 
    (This Function enabled through keypad only) 
    ; 9 2      ; [ _ ]           ; [ _ _ _ _ ] : 
                                           (Day)                                      (Time) 
    Functions 92 and 93 allow you to set up a window of time where if any Group 1 User Code  is entered within this window, 
    Group 4 members will be enabled.  (Group 4 members will still need to enter their User Codes to enter).   For additional 
    information, see Group 1 Activated Features on page 31. 
     
    •For day enter: 1 for Sunday
    , 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week.  •Enter time of day in 24 hour format (for example, for 2:15 PM, enter 14:15). 
    Scheduled Group 4 Enable (Group 1 Activated)  
    93. Enable Group 4  
    (Close Time Window) 
    (This Function enabled through keypad only) 
    ; 9 3      ; [ _ ]           ; [ _ _ _ _ ] : 
                                           (Day)                                      (Time) 
     3 
    Programming Functions (contd)  
    						
    All Alarm Lock manuals Comments (0)

    Related Manuals for Alarm Lock DK3000 Programming Manual