    							2018/02  – Subject to change11 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Valve function
    CodeCircuit symbolSizeDescription
    101418
    N, NK
    
    2x 3/2-way valve, single solenoid
    Normally open
    Pneumatic spring return
    Piston spool valve
    With duct separation 1, 11 for valve NK
    Size 18 only available for valve N
    The function of a 5/3-way valve with mid-position pressurised 
    can be implemented with these valves with initial position open.
    H, HK
    
    2x 3/2-way valve, single solenoid
    Normal position
    – 1x open (pilot control 12)
    – 1x closed (pilot control 14)
    Pneumatic spring return
    Piston spool valve
    With duct separation 1, 11 for valve HK
    Size 18 only available for valve H
    For optimised cylinder movement. Corresponds to valve function M with simul­
    taneous actuation of both solenoid coils (5/2-way, single solenoid). Since the
    piston area on each side can be pressurised or exhausted separately, it means
    that the cylinder can move faster.
    G
    ––
    5/3-way valve, mid-position closed
    Mechanical spring return
    Piston spool valve
    –
    5/3G1) function, mid-position closed
    For size 10 and 14
    The valve function “mid-position closed” is created from one 2x 3/2-way valve,
    normally closed (code C).
    The valve kit CPV10-BS-5/3G-M7 or CPV14-BS-5/3G-1/8 (incorporating
    a double piloted non-return valve function) is used for this. This valve kit is
    intended for applications with one working pressure level per valve slice, i.e. it
    must not be used in dual-pressure applications (where the pressure levels at
    port 1 and 11 are different).
    If other valve slices are to be used in dual-pressure mode, then the valve slice
    equipped with the 5/3G valve kit must be separated from compressed air
    duct 1 and 11 by means of a separator plate (code T).
    Not in first or last valve position with pneumatic multiple connector plate P
    and M. Cannot be used with pneumatic multiple connector plate GQC and
    GQD.
    Piston spool valve
    1) Cannot be assembled in conjunction with the control cabinet version of the pneumatic multiple connector plate CPV10-VI-P...-C or CPV10-VI-P...-D
    -H-Note
    A filter must be installed upstream of valves operated in vacuum mode. 
    This prevents any foreign matter in the intake air getting into the valve 
    (e.g. when operating a suction cup). 
    						
    							Subject to change – 2018/0212 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Valve function
    CodeCircuit symbolSizeDescription
    101418
    –
    
    5/3E function, mid-position exhausted
    The valve function “mid-position exhausted” is created using a 2x 3/2-way
    valve, normally closed (code C, CK).
    Pneumatic spring return
    Piston spool valve
    –
    
    5/3B function, mid-position pressurised
    The valve function “mid-position pressurised” is created using a 2x 3/2-way
    valve, normally open (code N, NK).
    Pneumatic spring return
    Piston spool valve
    D, DK
    
    2x 2/2-way valve, single solenoid
    Normally closed
    Pneumatic spring return
    Piston spool valve
    With duct separation 1, 11 for valve DK
    Size 18 only available for valve D
    I, IK
    
    2x 2/2-way valve, single solenoid
    Normal position
    – 1x open (control side 12)
    – 1x closed (control side 14)
    Pneumatic spring return
    Piston spool valve
    With duct separation 1, 11 for valve IK
    Size 18 only available for valve I
    RRelay plate (2 floating contacts)
    –
    A relay plate (code R) with (N/O contacts) can also be used instead of a valve
    slice. Each relay plate has two relays for actuating two electrically isolated
    outputs. Load capacity: 24VDC, 1A.
    Connecting cable KRP-1-24-…
    An inscription label holder cannot be used 
    						
    							2018/02  – Subject to change13 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Additional pneumatic functions
    CodeCircuit symbolSizeDescription
    101418
    AVacuum generator
    
    Vacuum generation according to the ejector principle.
    Vacuum slices of different widths for different suction capacities.
    Combinations with a number of vacuum slices and/or directional control
    function slices are possible on the same valve terminal.
    In principle, an open connection is formed between the exhaust duct 3/5 and
    the working line 4. When the nozzle is not switched, the resulting back pres­
    sure in the exhaust duct flows back into the working line. When the nozzle is
    switched, the vacuum can be greatly reduced by the resulting back pressure.
    This effect is improved through optimised exhausting. It does not occur where
    there is only one vacuum generator per valve terminal and where separator
    plates (codeS) are used for separation.
    Vacuum generator on pilot side 14
    Reset via mechanical spring and pneumatic spring
    Ejector pulse on pilot side 12 (code E)
    Note air supply and exhaust when using more than two vacuum generators
    EVacuum generator with ejector pulse
    
    PInput (valve side)
    Output (cylinder side)
    –
    2x one-way flow control valve, supply air flow control
    Module (actuator) for direct flange mounting on the CPV valves.
    Also suitable for pneumatic multiple connector plates.
    Different valve actuators cannot be combined.
    Not with valve function G
    Not in first or last valve position with accessories M, P, V 
    (pneumatic multiple connector plate)
    Cannot be used with accessories GQC and GQD
    (pneumatic multiple connector plate)
    QInput (valve side)
    Output (cylinder side)
    –
    2x one-way flow control valve, exhaust air flow control
    Module (actuator) for direct flange mounting on the CPV valves.
    Also suitable for pneumatic multiple connector plates.
    Different valve actuators cannot be combined.
    Not with valve function G
    Not in first or last valve position with accessories M, P, V 
    (pneumatic multiple connector plate)
    Cannot be used with accessories GQC and GQD
    (pneumatic multiple connector plate)
    VInput (valve side)
    Output (cylinder side)–
    One-way flow control valve for vacuum
    The module CPV-…-BS-GRZ-V-… has a built-in non-return valve as well as a flow
    control function for adjusting the ejector pulse. The non-return valve serves to
    temporarily maintain the vacuum, even if the vacuum generator is switched off.
    The module is suitable for vacuum generators (code A, E).
    Not in first or last valve position with accessories M, P, V 
    (pneumatic multiple connector plate)
    Cannot be used with accessories GQC and GQD
    (pneumatic multiple connector plate) 
    						
    							Subject to change – 2018/0214 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Creating pressure zones
    Different pressures at port 1 and 11
    result in two pressure levels per valve.
    This means, for example, that a cylin­
    der drive can be advanced using high
    pressure and retracted using low
    pressure to save energy.The maximum number of pressure
    zones possible is determined by the
    combination of the following
    components:Use of a separator plate
    End plate pair type
    Valve slice type
    Number of valve slicesThe CPV valve terminal can be divided
    into 2 to 4 pressure zones with the
    aid of separator plates or valves with
    integrated duct separation.
    Separator plates/valves with integrated duct separation
    CodeGraphical symbolSizeNote
    101418
    TSeparator plate for creating pressure zones,
    supply duct 1 and 11 separated
    Pilot exhaust air
    Pilot air supply
    Exhaust air
    Working air
    Working air82/84
    12/14
    3/5
    1
    11
    
    A separator plate (code T) is used to separate the duct for the air supply
    (port 1 and 11) to provide two pressure zones.
    Not in first or last valve position
    Not with compressed air supply A, B, C, D, U, V, W, X
    SSeparator plate for creating pressure zones,
    supply duct 1, 11 and exhaust 3/5 separated
    82/84
    12/14
    3/5
    1
    11 Pilot exhaust air
    Pilot air supply
    Exhaust air
    Working air
    Working air
    
    The separator plate (code S) separates the exhaust duct 3/5 as well as the
    supply duct 1 and 11. This plate should be used if one of the pressure zones
    is under vacuum to avoid any effects on the vacuum or to prevent back
    pressure on neighbouring valve functions.
    Not in first or last valve position
    Not with compressed air supply A, B, C, D, U, V, W, X
    (single-side compressed air supply)
    LBlanking plate (vacant position)
    Pilot exhaust air
    Pilot air supply
    Exhaust air
    Working air82/84
    3/5
    1
    Working air11
    12/14
    A blanking plate (code L) is used to create a vacant position where a valve
    can be positioned at a later date.
    MK,
    JK,
    CK,
    NK,
    DK,
    IKValve with integrated separation of ducts 1 and 11
    Pilot exhaust air
    Pilot air supply
    Exhaust air
    Working air
    Working air82/84
    12/14
    3/5
    1
    11
    –
    With these valves the ducts for the air supply (port 1 and 11) are closed to
    the right-hand side of the valve with a cast membrane. The advantage of
    using this instead of a separator plate is that no valve location is occupied
    by a separator plate.
    -H-Note
    Where internal pilot air via the right-hand end plate is used as the
    compressed air supply, at least one further valve with the code M, F, J, C, CY,
    N, H, G, D, I, A or E must be used directly to the right of this valve. 
    						
    							2018/02  – Subject to change15 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Examples: Compressed air supply
    External pilot air supply, flat plate silencer at both ends
    Compressed air supply via pneumatic
    multiple connector plate:
    code H
    The diagram opposite shows an
    example of the configuration and con­
    nection of the compressed air supply
    with external pilot air supply. Port
    12/14 on the pneumatic multiple con­
    nector plate is equipped with a fitting
    for this purpose. Ports 3/5 and 82/84
    are vented via the flat plate silencers.
    One separating seal each can be
    optionally used to create pressure
    zones.Optional separating
    seal
    Internal pilot air supply, ducted exhaust air or threaded silencer
    Compressed air supply via end plates:
    code Z
    The diagram opposite shows an
    example of the configuration and con­
    nection of the compressed air supply
    with internal pilot air supply.
    The pilot air is branched at the right-
    hand end plate of port 1 or 11. Ports
    3/5 and 82/84 are vented via the
    threaded silencer.
    One separating seal each can be
    optionally used to create pressure
    zones.Optional separating
    seal 
    						
    							Subject to change – 2018/0216 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Example: Creating pressure zones
    CPV with separator plate T
    With the CPV valve terminals up to
    four pressure zones can be implem­
    ented. The diagram shows an example
    of the configuration and connection of
    four pressure zones using separator
    plate code T – with external pilot air
    supply.Zone 2
    Zone 1Zone 4
    Zone 3
    12 43
    1Vacuum –0.9 bar
    2Blast pulse 2 bar3Forward stroke 6 bar
    4Return stroke 4 bar
    CPV with integrated separation of ducts 1 and 11 with valves …K
    With the CPV valve terminals up to
    four pressure zones can be implem­
    ented. The diagram shows an example
    of the configuration and connection of
    four pressure zones with external pilot
    air supply and the use of a valve …K
    with integrated separation of ducts 1
    and 11.Zone 2
    Zone 1Zone 4
    Zone 3
    12 43
    1Vacuum –0.9 bar
    2Blast pulse 2 bar3Forward stroke 6 bar
    4Return stroke 4 bar 
    						
    							2018/02  – Subject to change17 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    Compressed air supply and exhausting
    The two end plates that pressurise
    and exhaust the valve slices are
    a characteristic feature of a CPV valve
    terminal:
    Large duct cross sections ensure
    maximum flow rates even when
    multiple valves are switched in
    parallelLarge flat plate silencers in the end
    plates
    Internal/external pilot air supply
    Each individual valve is supplied with
    compressed air from two individual
    ducts (supply ports 1/11) andexhausted via a large, integrated ex­
    haust duct (exhaust 3/5). This design
    permits unique flexibility and func­
    tionality. It is the easiest way of realis­
    ing a number of pressure zones per
    terminal or combinations of vacuumapplications.
    The valve terminal is supplied via end
    plates, either on the left, on the right
    or on both sides. End plate combina­
    tions other than those listed are
    possible (on request).
    Pilot air supply
    Internal pilot air supplyExternal pilot air supply
    Internal pilot air supply can be se­
    lected if the supply pressure at pneu­
    matic port 1 is 3 … 8 bar. With inter­
    nal pilot air supply the branch is
    located in the left or right-hand end
    plate. There is no port 12/14.External pilot air supply is required if
    the supply pressure at pneumatic port
    1 is less than 3 bar or greater than
    8 bar. In this case, pressure of
    3 … 8 bar is applied at port 12/14.
    If a gradual pressure build-up in thesystem using a pressurised on-off
    valve is required, external pilot supply
    air should be selected. The control
    pressure applied during switch-on is
    already very high in this case.
    External pilot air supply is alsorequired if it is necessary to ensure
    that the back pressure flaps (valve
    order code CY) are closed securely in
    the event of a sudden drop in operat­
    ing pressure or if the operating
    pressure is switched off.
    End plates
    Example of an end plate:
    The diagram shows a left-hand end
    plate with external pilot air supply.
    The exhaust ports 3/5 and 82/84 canbe equipped with fittings or silencers.
    An end plate for internal pilot air
    supply does not have ports 12/14
    and 11.The port 82/84 is always present
    and should be fitted with a silencer.
    The port 12/14 is connected internally
    with port 1 on an end plate for
    internal pilot air supply. 
    						
    							Subject to change – 2018/0218 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    End plate combination for compressed air supply via end plate
    CodeGraphical symbol
    Type of pilot air supply (internal/external)SizeNote
    101418
    UInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in right-hand end plate only
    No pressure zone separation permissible
    Not suitable for vacuum
    VInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in left-hand end plate only
    No pressure zone separation permissible
    Not suitable for vacuum
    WExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in right-hand end plate only
    No pressure zone separation permissible
    Suitable for vacuum
    XExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in left-hand end plate only
    No pressure zone separation permissible
    Suitable for vacuum
    YInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in left-hand and right-hand end plate
    Maximum three pressure zones
    Valves to the left of the separator plate
    suitable for vacuum
    ZExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in left-hand and right-hand end plate
    Maximum four pressure zones
    Suitable for vacuum 
    						
    							2018/02  – Subject to change19 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    End plate combination for compressed air supply via pneumatic multiple connector plate
    CodeGraphical symbol
    Type of pilot air supply (internal/external)SizeNote
    101418
    YInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Pressure zone separation only permissible
    with separator plate (code T)
    Maximum two pressure zones
    Valves to the left of the separator plate
    suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    ZExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Pressure zone separation only permissible
    with separator plate (code T)
    Maximum three pressure zones
    Suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    End plate combination for compressed air supply via end plates with flat plate silencer
    CodeGraphical symbol
    Type of pilot air supply (internal/external)SizeNote
    101418
    AInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in right-hand end plate
    No pressure zone separation permissible
    Not suitable for vacuum
    BInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in left-hand end plate
    No pressure zone separation permissible
    Not suitable for vacuum
    CExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in right-hand end plate
    No pressure zone separation permissible
    Suitable for vacuum
    DExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports in left-hand end plate
    No pressure zone separation permissible
    Suitable for vacuum 
    						
    							Subject to change – 2018/0220 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Pneumatic components
    End plate combination for compressed air supply via pneumatic multiple connector plate with flat plate silencer
    CodeGraphical symbol
    Type of pilot air supply (internal/external)SizeNote
    101418
    EExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Exhaust air vented via flat plate silencer on
    the right
    Pressure zone separation only permissible
    with separator plate (code T)
    Maximum four pressure zones
    Suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    FExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Exhaust air vented via flat plate silencer on
    the left
    Pressure zone separation only permissible
    with separator plate (code T)
    Maximum four pressure zones
    Suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    GInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Exhaust air vented via flat plate silencer on
    the left
    Pressure zone separation only permissible
    with separator plate (code T)
    Maximum three pressure zones
    Not suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    HExternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Exhaust air vented via flat plate silencers at
    both ends
    Pressure zone separation permissible
    Suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    JInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Exhaust air vented via flat plate silencers at
    both ends
    Pressure zone separation permissible
    Maximum three pressure zones
    Valves to the left of the separator plate
    suitable for vacuum
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate)
    KInternal pilot air supply
    82/84
    3/5
    12/14
    11
    1
    
    Ports on pneumatic multiple connector plate
    Exhaust air vented via flat plate silencer on
    the right
    Pressure zone separation permissible
    Maximum three pressure zones
    Suitable for vacuum in combination 
    with separator plate
    Only for accessories M, P, V, GQC, GQD
    (pneumatic multiple connector plate) 
    						
    All GE manuals Comments (0)