    							2018/02  – Subject to change31 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Electrical components
    ET200X/ET200pro pneumatic interface for CPV10 and CPV14
    Adaptation of the CPV valve manifold
    to the input/output module
    ET200X/ET200pro from Siemens. The
    combination of the functional mod­
    ules of the ET200X/ET200pro and the
    pneumatic functions of the CPV valve
    manifold provides a highly integrat­
    able automation solution for systems
    using electrical and pneumatic driveswith:
    8 valve slices for up to 16 CPV
    valves
    Faster and more reliable contacting
    CPV10 and CPV14 valve manifold
    High IP65/IP67 protection
    Modular designLarge number of I/O modules
    – digital I/O
    – analogue I/O
    – supply branching for activa­
    tion of three-phase motors
    Profibus DP interfaceMounting kit for ET200X
    CPV-…-VI-BG-ET200X 
    (included in the scope of delivery)
    Specific data on the ET200X/ET200pro
    pneumatic interface can be found in
    Siemens product catalogues.
    -H-Note
    A moulded seal is required for the
    valve manifold CPV10-ET200pro in
    order to achieve the IP protection
    class.The moulded seal CPV10-…-GE-8 or
    CPV14-…-GE-8 must be ordered
    separately. 
    						
    							Subject to change – 2018/0232 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Electrical components
    Multi-pin plug connection
    In addition to pneumatic integration,
    a multi-pin plug connection also pro­
    vides integration of the electrical side
    and facilitates connection to the
    control cabinet and the valve terminal
    via a single cable.
    Sub-D 9-pin and 25-pin plugs are
    used for connection. The plug housing
    of the KMP-…- cable provides the
    Sub-D connectors with IP65
    protection.The following sizes of plug connector
    are used:
    4-valve valve terminal: 9-pin
    6-valve valve terminal: 25-pin
    8-valve valve terminal: 25-pin
    Prefabricated connecting cables are
    available for easy connection.
    Standard lengths of 5m and 10m
    can be supplied. The pre-assembled
    connecting cables are also available
    in a design suitable for use with
    energy chains.The cable KMP6-… can alternatively
    be used for applications with IP40
    protection.
    Pin allocation – Pre-assembled multi-pin cable (viewed from plug-in direction)
    Plug viewPinWire colourValve 24 V DC
    Cable KMP3-25P-16… or KMP4-25P… with 25-pin Sub-D plug for 6-valve and 8-valve valve terminal
    1White114
    2Green12
    3Yellow214
    4Grey12
    5Pink314
    6Blue12
    7Red414
    8Purple12
    9Grey-pink514
    10Red-blue12
    11White-green614
    12Brown-green12
    13White-yellow714
    14Yellow-brown12
    15White-grey814
    16Grey-brown12
    17White-pink (KMP4 only)
    18Pink-brown (KMP4 only)
    19White-blue (KMP4 only)
    20Brown-blue (KMP4 only)
    21White-red (KMP4 only)
    22Brown-red (KMP4 only)
    23White-black (KMP4 only)
    24Brown(0 V)1)
    25Black(0 V)1)
    Cable KMP3-9P… or KMP4-9P… with 9-pin Sub-D plug for 4-valve valve terminal
    1White114
    2Green12
    3Yellow214
    4Grey12
    5Pink314
    6Blue12
    7Red414
    8Purple12
    9BlackCommon
    1) 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted. 
    						
    							2018/02  – Subject to change33 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Electrical components
    Pin allocation – Pre-assembled multi-pin cable (viewed from plug-in direction)
    Plug viewPinWire colourValve 24 V DC
    Cable KMP6-25P-20… with 25-pin Sub-D plug for 6-valve and 8-valve valve terminals
    1White114
    2Brown12
    3Green214
    4Yellow12
    5Grey314
    6Pink12
    7Blue414
    8Red12
    9Black514
    10Purple12
    11Grey-pink614
    12Red-blue12
    13White-green714
    14Brown-green12
    15White-yellow814
    16Yellow-brown12
    17White-grey
    18Grey-brown
    19White-pink
    20Pink-brown
    21White-blue1)
    22Brown-blue1)
    23White-red1)
    24Brown-red1)(0 V)2)
    25White-black1)(0 V)2)
    Cable KMP6-9P-20… with 9-pin Sub-D plug for 4-valve valve terminals
    1White114
    2Brown12
    3Green214
    4Yellow12
    5Grey314
    6Pink12
    7Blue414
    8Red12
    9BlackCommon
    1) Wire cross section 0.34 mm22) 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted.
    -H-Note
    Two threaded sleeves (NEAU-TA-M35-U4,
     p. 63) are required to secure the
    multi-pin cable MKP6. 
    						
    							Subject to change – 2018/0234 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Electrical components
    Valve terminal CPV – AS-interface valve terminal
    The AS-interface facilitates wide rang­
    ing physical distribution of individual
    components or small component
    groups.
    The AS-interface connection of valve
    terminal CPV can be used to control 2,
    4, 8 solenoid coils.
    The valve terminal cover contains the
    LEDs that indicate the operating status
    and the protective circuit for the
    valves.The AS-interface protocol standard
    permits a maximum of 4 inputs and
    4 outputs in one unit. The use of 2 AS-
    interface slaves in one valve terminal
    means that 8 inputs and 8 outputs
    can be controlled in an 8-valve valve
    terminal (8 solenoid coils).
    All CPV valve terminals can be
    operated using additional functions,
    e.g. relay plates or vacuum generators.Valve terminals CPV with inputs are
    also available for A/B operation to
    SPEC 2.1 and 3.0.
    AS-interface control
    For 2, 4 or 8 valves
    Great variety thanks to the wide
    range of modules in the system
    AS-interface with A/B operation
    For 3 or 4 and/or 6 or 8 valves
    depending on the specification
    All the benefits of the simple
    installation system are retained100% more inputs/master
    50% more outputs/master
    Improved peripheral error
    diagnostics
    More AS-interface functions in
    Specifications 2.1 and 3.0
     Internet: as-interface
    AS-interface valve terminal with auxiliary power supplyAS-interface valve terminal with auxiliary power supply and inputs 
    						
    							2018/02  – Subject to change35 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Key features – Electrical components
    I-Port interface/IO-Link
    The I-Port interface/IO-Link enables
    the valve terminal CPV to be connec­
    ted to the following systems:
    I-Port master from Festo 
    (CPX terminal, CECC)
    Fieldbus node CTEU from Festo
    IO-Link master
    A maximum of 16 solenoid coils can
    be actuated distributed over a
    maximum of 8 valve positions.The maximum distance between the
    I-Port/IO-Link master and valve ter­
    minal with I-Port interface/IO-Link is
    20 m.
    The 5-pin connecting cables contain
    the power supply for the valves, sep­
    arate from this is the power supply for
    the internal valve terminal electronics
    and the control signals.The valve terminal cover contains the
    LEDs that indicate the operating
    status and the protective circuit for
    the valves.
    All valve terminals CPV can be oper­
    ated with other functions such as
    relay plates or vacuum generators. Internet: cteu
     Internet: cpx
     Internet: cecc
    CPV valve terminal with I-Port interface/IO-LinkCPV valve terminal with I-Port interface with fieldbus node
    CP/CPI installation system, valve terminal
    11
    The integration of valve terminal CPV
    into a fieldbus system or independent
    control system is accomplished by
    connecting the terminal to the corre­
    sponding fieldbus node or control
    block with simple, pre-assembled ter­
    minal connectors.
    The installation system integrates the
    valve terminal CPV and various I/O
    modules, etc. into a single installation
    concept.The 5-pin connecting cables carry the
    supply power and control signals.
    The valve terminal cover contains the
    LEDs that indicate the operating
    status and the protective circuits for
    the valves.
    Max. 8 valve slices for up to 16 CPV
    valvesThe CP string is used to exchange the
    input and output states of the con­
    nected modules with the CP fieldbus
    node.
     Internet: ctec 
    						
    							Subject to change – 2018/0236 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Instructions for use
    Fieldbus Direct valve terminal
    Fieldbus Direct is a system for
    connecting one valve terminal to nine
    different fieldbus standards. The most
    important systems, including
    PROFIBUS, INTERBUS, DeviceNet and
    CANopen, are supported.
    The CP string extension option en­
    ables the functions and componentsof the CPI installation system to be
    used.
    The optional string extension permits
    additional valve terminals and I/O
    modules with CP/CPI function to be
    connected to the Fieldbus Direct
    fieldbus node.Depending on the version, the valve
    terminals are available in all three
    sizes, 10, 14 and 18 mm, each with
    8 valve slices.
    Equipment
    Operate system equipment with unlu­
    bricated compressed air if possible.
    Festo valves and cylinders are de­
    signed so that, if used as designated,
    they will not require additional lu­
    brication and will still achieve a long
    service life.
    The quality of compressed air down­
    stream of the compressor must corre­
    spond to that of unlubricated com­
    pressed air. If possible, do not operate
    all your system equipment with lubri­
    cated compressed air. The lubricators
    should, where possible, always be
    installed directly upstream of the
    actuator used.Incorrect additional oil and too high
    an oil content in the compressed air
    reduce the service life of the valve
    terminal.
    Use Festo special oil OFSW-32 or the
    alternatives listed in the Festo
    catalogue (as specified in DIN 51524
    HLP32; basic oil viscosity 32 CST
    at 40°C).Bio-oils
    When using bio-oils (oils based on
    synthetic or native ester, e.g. rapeseed
    oil methyl ester), the maximum
    residual oil content of 0.1 mg/m
    3
    must not be exceeded
    (see ISO 8573-1 Class 2).Mineral oils
    When using mineral oils (e.g. HLP oils
    to DIN 51524, parts 1 to 3) or similar
    oils based on poly-alpha-olefins
    (PAO), the maximum residual oil con­
    tent of 5 mg/m3
     must not be exceeded
    (see ISO 8573-1 Class 4).
    A higher residual oil content irrespec­
    tive of the compressor oil cannot be
    permitted, as the basic lubricant
    would be flushed out over time. 
    						
    							2018/02  – Subject to change37 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Technical data
    -M-Flow rate up to
    CPV10: 400  l/min
    CPV14: 800 l/min
    CPV18: 1600 l/min
    -K-Valve width
    CPV10: 10 mm
    CPV14: 14 mm
    CPV18: 18 mm
    -P-Voltage
    24 V DC
    General technical data
    CPV10CPV14CPV18
    DesignElectromagnetically actuated piston spool valve
    LubricationLife-time lubrication, PWIS-free (free of paint-wetting impairment substances)
    Type of mountingVia pneumatic multiple connector plate
    Via backwall
    On H-rail
    Mounting positionAny
    Manual overrideNon-detenting/detenting/blocked
    Width[mm]101418
    Nominal size[mm]468
    Nominal flow rate without fitting[l/min]4008001600
    14003)
    b value0.40.42
    0.372)0.38
    0.412)
    0.403)
    c value[l/sbar]1.63.26.3
    5.663)
    Pneumatic connections1)
    Pneumatic connectionVia end plate or pneumatic multiple connector plate
    Supply port1/11G1/8G1/4G3/8
    Exhaust port3/5G3/8 (G1/4)G1/2 (G3/8)G1/2
    Working ports2/4M7G1/8G1/4
    Pilot air supply port12/14M5 (M7)G1/4G1/4
    Pilot exhaust air port82/84M5 (M7)G1/8G1/4
    1) Connection dimensions in brackets for pneumatic multiple connector plate
    2) Values for 2x 2/2-way valve
    3) Values for 5/3-way valve with mechanical spring return
    Safety characteristics
    CPV10CPV14CPV18
    Max. positive test pulse with 0 signal[ìs]140014001900
    Max. negative test pulse with 1 signal[ìs]7004001700
    Shock resistanceShock test with severity level 2, to EN 60068-2-27
    Vibration resistanceTransport application test with severity level 2, to EN 60068-2-6 
    						
    							Subject to change – 2018/0238 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Technical data
    Operating and environmental conditions
    Valve function order codeM, MKFJ, JKN, NKC, CKCYH, HKGD, DKI, IKAE
    Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]  page 36
    Note on operating/pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
    Operating pressure[bar]–0.9 … +10+0.1 … +10–0.9 … +10
    Operating pressure for valve terminal
    with internal pilot air supply[bar]3 … 8
    Pilot pressure[bar]3 … 8
    Ambient temperature[°C]–5 … +50 (vacuum generators: 0 … +50)
    Temperature of medium[°C]–5 … +50 (vacuum generators: 0 … +50)
    Storage temperature[°C]–20 … +40
    Relative air humidity at 25 °C[%]95 with no condensation
    Corrosion resistance class CRC1)21
    Note on materialsRoHS-compliant
    1) Corrosion resistance class CRC 1 to Festo standard FN 940070
    Low corrosion stress. For dry indoor applications or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive
    trunnions).
    Corrosion resistance class CRC 2 to Festo standard  FN  940070
    Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­
    sphere typical for industrial applications.
    ATEX
    ATEX category for gasII 3G
    Type of ignition protection for gasEx nA IIC T4 X Gc
    ATEX category for dust–5 ≤ Ta ≤ +50
    Certificationc UL us Recognized (OL)
    C-Tick
    Explosion protection certification outside the EUNEC 500 Class I, Div. 2
    CE marking (see declaration of conformity)To EU Explosion Protection Directive (ATEX)
    To EU EMC Directive
    -H-Note
    The ATEX certification in accordance
    with the EU ATEX directive onlyapplies to fully assembled valve
    terminals.
    ATEX
    Permitted pneumatic multiple connector plates for the valve terminal CPV
    Pneumatic multiple connector plateCPV10-VI-P…-1/8-CCPV10­VI­P…-M7-…CPV14-VI-P…-1/8-…
    ATEX category for gasII 2G
    Type of ignition protection for gasEx e II
    ATEX category for dustII 2D
    Type of ignition protection for dustEx tD A21 IP65
    ATEX ambient temperature[°C]–10 ≤ Ta ≤ +60
    Certificate issuing authorityTÜV 06 ATEX 7334 XTÜV 06 ATEX 7334 X
    IECEx TUR 12.0002X
    Explosion protection certification outside the EUEPL Db (IEC-EX)–
    EPL Gb (IECEx)–
    CE marking (see declaration of conformity)To EU Explosion Protection Directive (ATEX) 
    						
    							2018/02  – Subject to change39 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Technical data
    Electrical
    CPV10CPV14CPV18
    Operating voltage[V DC]24  (+10/–15%)
    Edge steepness
    (IC and MP only)[V/ms] 0.4 minimum voltage increase time to reach the high-current phase
    Limitation of the voltage peaks when
    switching off[V DC]38
    Residual ripple[Vss]4
    Electrical power consumption[W]0.6 (0.45 at 21 V); 
    (at CPV10-M11H-… 0.65)0.9 (0.65 at 21 V)1.5 (0.95 at 21 V)
    Duty cycle ED
    with pilot air supply[%]100
    [bar]–0.9 … +10
    Protection against electric shock (protection
    against direct and indirect contact to
    EN 60204-1/IEC 204)By means of PELV power supply unit
    Degree of protection to EN 60529[IP]65 (for all types of signal transmission in mounted state)
    Relay plate
    CPV10CPV14CPV18
    Operating voltage[V DC ]20.4 … 26.4–
    Electrical power consumption[W]1.2–
    No. of relays2 with galvanically isolated outputs–
    Load current circuitEach 1 A/24 V DC +10%–
    Relay response timesOn[ms]5–
    Off[ms]2–
    Valve switching times [ms]
    Valve function order codeMMKFJJKNNKCCKCYHHKGDDKIIKAE
    CPV10
    Switching timesOn171712––171717171717172015151515–15
    Off272717––252525252525253017171717–17
    Change­
    over–––1010––––––––––––––
    CPV14
    Switching timesOn2525–––24242424–24242213131313–13
    Off3535–––30303030–30303016161616–16
    Change­
    over–––1212––––––––––––––
    CPV18
    Switching timesOn18––––18–18––––1414–14––14
    Off26––––24–24––––3220–20––20
    Change­
    over–––12––––––––––––––– 
    						
    							Subject to change – 2018/0240 Internet: www.festo.com/catalogue/...
    Valve terminals CPV, Compact Performance
    Technical data
    Materials
    CPV10CPV14CPV18
    Basic electrical unitDie-cast aluminium, PA, NBR
    Valve slicesDie-cast aluminium
    Valve module 5/3GCast aluminium, POM
    Relay platePA, brass
    Blanking plate/separator platePA
    End platesDie-cast aluminium
    Flat plate silencerDie-cast aluminium, PE
    Pneumatic multiple connector plateWrought aluminium alloy
    Inscription label holderPOM, PVC
    SealNBR, HNBR
    Product weight
    Approx. weight[g]CPV10CPV14CPV18
    Electrical connection plates with AS-Interface
    connection
    on CP valve terminals with 2 valve positions85130275
    on CP valve terminals with 4 valve positions110175355
    on CP valve terminals with 8 valve positions400460–
    Electrical connection plates with CP connection
    on CP valve terminals with 4 valve positions145230375
    on CP valve terminals with 6 valve positions180250450
    on CP valve terminals with 8 valve positions200300540
    Electrical connection plates with MP connection
    on CP valve terminals with 4 valve positions110170400
    on CP valve terminals with 6 valve positions140230425
    on CP valve terminals with 8 valve positions165275515
    End plates (2 pieces)160280740
    Pneumatic multiple connector plate
    on CP valve terminals with 2 valve positions120270520
    on CP valve terminals with 4 valve positions165390750
    on CP valve terminals with 6 valve positions225510870
    on CP valve terminals with 8 valve positions2706301300
    Flat plate silencer147234–
    Relay plate3555–
    Blanking plate254590
    Separator plate254590
    Valve sub-bases, vacuum generators70110260
    Function element: 5/3G function46105–
    Function element: one-way flow control valve2554125 
    						