    							Accenta/Optima Engineer’s Manual
    27
    Timers (cont’d)
    LED Keypad:
    To change the Rearm Count:
    .
    •Press [7] to enter Set Up Timers.LED’s 1, 2 and 3 are on.
    •Press [3] for Rearm Count. LED 1 is on.
    •Select a number [0 - 9] to change the rearm count.
    •To accept the change press [SET].  LED’s 1, 2 and 3 are
    on. Press [RESET].
    OR to cancel the change press the [RESET] button twice.
    73 = Set Up Rearm Count
    After an alarm the panel will automatically rearm itself when the external siren (Bell) timer has expired. Any
    zones which still remain open at that time will be automatically omitted . The default is 3 rearms.
    0 = no rearms
    1-8 = number of rearms
    9 = always rearm
    LCD keypad:
    To change the Rearm Count:
    •Press [up arrow] for menu Set Up Timers.
    •Press [7]or [SET]. Option 1 Set up Bell Time appears.
    •Press [3]. The Rearm Count is displayed (default 3).
    • Select a number [0 - 9] to change the rearm count.
    • To accept the change press [SET] then [RESET]
    •OR to cancel the change press the [RESET] button twice.
    [7]
    [SET] then [RESET] or [RESET]
    [3]
    [Number]
    1234
    5
    678
    1234
    5
    678
    1234
    5
    678
    7>Set Up 7>Set Up7>Set Up 7>Set Up
    7>Set Up
      Timers   Timers  Timers   Timers
      Timers
    Rearm Count Rearm CountRearm Count Rearm Count
    Rearm Count
    3 33 3
    3[3]
    71>Set Up 71>Set Up71>Set Up 71>Set Up
    71>Set Up
       Bell Time    Bell Time   Bell Time    Bell Time
       Bell Time[7] or [SET]
    7>Set Up 7>Set Up7>Set Up 7>Set Up
    7>Set Up
      Timers   Timers  Timers   Timers
      Timersor [RESET]
    73>Set Up 73>Set Up73>Set Up 73>Set Up
    73>Set Up
      Rearm Count   Rearm Count  Rearm Count   Rearm Count
      Rearm Count[SET] then [RESET]
    [up arrow]
    1234
    5
    678 
    						
    							Accenta/Optima Engineer’s Manual
    28
    To change the other codes: Press the [up arrow] to move through the codes.
    [2] = User 2
    [3] = Duress
    [4] = Engineer LCD Keypad:
    To change User code:
    • Press the [8] button on the keypad or press the
    [up arrow] for Set Up Codes. Then press [SET].
    • Press the [1] or [SET] button on the keypad to
    edit user code.
    • Enter the new [4-digit code].
    • Upon the last keypress the code is saved.
    8 = Set Up Codes
    There are four codes used in the system, all are 4 digit and can be set to any number from 0000 to 9999. The
    access codes ensure that only authorised users can operate the system.
    User 1 and 2 codes
    The user 1 and user 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which
    is usually considered to be the Manager’s code has the authority to add, change or delete the user 2 code and
    duress code.
    Duress code
    Should be used in a hold up situation where there is pressure to Set or Unset the system. Entry of the code
    will allow the system to work normally but also generate a silent PA type alarm by operating the PA communi-
    cator output. The duress code is not applicable for Optima compact system.
    Engineer code
    Accesses the Engineer program mode to allow the system to be programmed. The engineer code will not set
    or unset the system.
    If configured the Engineer’s code can be used to reset the system after an alarm.
    NOTE:Entering an invalid user code will operate the code tamper. After 17 incorrect keypushes a full alarm
    condition will be generated.
    Codes (cont’d)
    8>Set Up 8>Set Up8>Set Up 8>Set Up
    8>Set Up
    User 1 User 1User 1 User 1
    User 1
    Edit Code Edit CodeEdit Code Edit Code
    Edit Code
    ---- -------- ----
    ----
    Code Saved Code SavedCode Saved Code Saved
    Code Saved[8] or [up arrow] then [SET]
    [1] or [SET]
    [4-digit code] 
    						
    							Accenta/Optima Engineer’s Manual
    29
    Codes (cont’d)
    LED Keypad:
    To change User code:
    • Press [8] to edit user code. LED’s 1-4 are on.
    • Press [1] or [SET] to edit user code 1. LED’s 1-4 are on.
    • Enter the new 4-digit code.
    • Upon the last keypress the new code is saved.
    • To leave menu press [RESET] twice.
    The other codes are changed in a similar manner from step 2;
    Press [2] for User 2
    Press [3] for Duress code
    Press [4] for Engineer code.
    NOTE:To delete the 4-digit code from User 2 or Duress, enter into Edit Code and press [OMIT]. [8]
    1234
    5
    678
    [1] or [SET]
    [4-digit code]
    1234
    5
    678
    1234
    5
    678 
    						
    							Accenta/Optima Engineer’s Manual
    30
    C = View Event Log
    1 = LCD Keypad:
    The event log gives a display of all the events that have taken place. The events are arranged by date and time.
    Up to 250 events can be stored in the memory. When the log reaches 250 events and another event takes
    place, the first event drops out. The system is known as FILO (First In Last Out).
    To view the event log:
    • Press the [up arrow] until you come to the first screen.
    • Press [CHIME] or [SET] .
    • Choose [1] for Event Log in LCD screen.
    • The last event (250) appears on LCD screen.
    To go forward through the event log in sequence, press [OMIT].
    To go back through the event log in sequence, press the [up arrow].
    • Press [RESET] twice to leave the menu
    To go to a specific event:
    • Press the [PROG] button.
    • Key in Event Number you want to see (eg 150).
    • Press the [SET] button. The event appears on the LCD screen.
    • Press [SET] again to see further details of the event.
    • Press [RESET] twice to leave the menu option.
    Event Log
    250>ENG ACCESS 250>ENG ACCESS250>ENG ACCESS 250>ENG ACCESS
    250>ENG ACCESS
    08:44:03 17-May 08:44:03 17-May08:44:03 17-May 08:44:03 17-May
    08:44:03 17-May
    C>View C>ViewC>View C>View
    C>View
      Event Log   Event Log  Event Log   Event Log
      Event Log
    [CHIME] or [SET]
    Event Log Event LogEvent Log Event Log
    Event Log
    1 LCD, 2 LED? 1 LCD, 2 LED?1 LCD, 2 LED? 1 LCD, 2 LED?
    1 LCD, 2 LED?
    [1]
    Event Number? Event Number?Event Number? Event Number?
    Event Number?
    ### ###### ###
    ###[PROG]
    [150]
    150>Code entry 150>Code entry150>Code entry 150>Code entry
    150>Code entry
    09:23:12 04-Jan 09:23:12 04-Jan09:23:12 04-Jan 09:23:12 04-Jan
    09:23:12 04-Jan[SET]
    [SET]
    [RESET]
    Event Number? Event Number?Event Number? Event Number?
    Event Number?
    150 150150 150
    150
    User 4 User 4User 4 User 4
    User 4
    C>View C>ViewC>View C>View
    C>View
    Event Log Event LogEvent Log Event Log
    Event Log 
    						
    							Accenta/Optima Engineer’s Manual
    31
    2 = LED Keypad:
    The LED keypad is limited to show the last eight set periods with the eighth being the oldest. Zone, PA and
    Tamper indicators will be lit to show zone in alarm . Flashing LED indicates the first zone in alarm. Day indi-
    cates the status of the panel at the time of the alarm.
    O = Omit Allow and Double Knock
    1 = Double Knock
    Double knock programming is used when zones are likely to create false activations. Double knock requires
    two activations within 10 minutes of the same zone or a zone left open for 10 seconds.
    NOTE:It is not advisable to apply Double Knock to magnetic door contacts. Double Knock cannot be
    applied to Fire Zones. By default, no zones are in Double Knock mode and all zones are enabled as
    Omit Allow.
    LCD Keypad:
    Programming a Zone as Double Knock
    The [up arrow] scrolls through zones.
    Press [CHIME] to toggle double knock status on or off.
    Press [9] to turn all double knock zones on.
    Press [0] to turn all double knock zones off. • Press [CHIME] to enter into Event Log menu. LED’s 1 and 2 are on.
    • Press [2] for LED keypad. The first zone to activate is indicated by a
    flashing LED.
    • Press [1 to 8] for the desired event or [CHIME] to go through
    events in sequence.
    • Press [RESET] twice to leave the menu.
    While in Engineer program mode press [OMIT] or press [up arrow]
    until 0>Omit allow & Double Knock is displayed then press [SET].
    • Press [1] to select Double Knock. The first zone is
    displayed with status NO or YES.
    • Press the [zone number] or [CHIME] to toggle the
    status on or off.
    • Press the [up arrow] or [zone number] to go to the
    other zones and follow the same procedure as above.
    • Press [RESET] twice to leave the menu.
    1. Double Knock 1. Double Knock1. Double Knock 1. Double Knock
    1. Double Knock
    2. Omit Allow 2. Omit Allow2. Omit Allow 2. Omit Allow
    2. Omit Allow[OMIT]
    [1]
    [RESET]
    Omit Allow & Omit Allow &Omit Allow & Omit Allow &
    Omit Allow &
    Double Knock Double KnockDouble Knock Double Knock
    Double Knock
    1:  1: 1:  1: 
    1: 
    Double Knock:NO Double Knock:NODouble Knock:NO Double Knock:NO
    Double Knock:NO
    1:  1: 1:  1: 
    1: 
    Double Knock:YES Double Knock:YESDouble Knock:YES Double Knock:YES
    Double Knock:YES[zone number] or [CHIME]
    Event Log (cont’d)
    1234
    5
    678
    [CHIME]
    [RESET]
    1234
    5
    678 
    						
    							Accenta/Optima Engineer’s Manual
    32
    LED Keypad:
    Press [CHIME] to toggle double knock status on or off.
    Press [9] to turn all double knock zones on.
    Press [0] to turn all double knock zones off.
    • Press [OMIT] to enter into menu. LED’s 1 and 2 are on.
    • Press [1] to select Double Knock.
    • Press zone number [1-8] to choose a particular zone.
    • Press the zone [number] or [CHIME] to toggle the double
    knock status on or off. The appropriate LED is on when the zone is
    set up as Double Knock. Default settings are off.
    • Press [RESET] twice to leave the menu.
    2 = Omit Allow
    When a zone is programmed as Omit Allow, the panel allows the zone to be omitted for one set period by the
    user when setting the system.
    Programming a Zone as Omit Allow
    The [up arrow] scrolls through zones.
    Press [CHIME] to toggle omit allow status on or off.
    Press [9] to turn all omit allow zones on.
    Press [0] to turn all omit allow zones off.
    LCD Keypad:
    While in Engineer program mode press [OMIT]or press [up arrow]
    until 0>Omit allow & Double Knock is displayed then press [SET].
    • Press [2] to select Omit Allow. The first zone is
    displayed with status on or off.
    • Press the [zone number] or [CHIME] to toggle the
    status on or off.
    • Press the [up arrow] or [zone number] to go to the
    other zones and follow the same procedure as above.
    • Press [RESET] twice to leave the menu.
    1. Double Knock 1. Double Knock1. Double Knock 1. Double Knock
    1. Double Knock
    2. Omit Allow 2. Omit Allow2. Omit Allow 2. Omit Allow
    2. Omit Allow[OMIT]
    [2]
    [RESET]
    Omit Allow & Omit Allow &Omit Allow & Omit Allow &
    Omit Allow &
    Double Knock Double KnockDouble Knock Double Knock
    Double Knock
    2:  2: 2:  2: 
    2: 
    Omit Allow:NO Omit Allow:NOOmit Allow:NO Omit Allow:NO
    Omit Allow:NO
    2:  2: 2:  2: 
    2: 
    Omit Allow:YES Omit Allow:YESOmit Allow:YES Omit Allow:YES
    Omit Allow:YES[zone number] or [CHIME]
    Omit Allow & Double Knock
    [OMIT]
    [1]
    1234
    5
    678
    [1-8] or [CHIME]
    [RESET]
    1234
    5
    678
    1234
    5
    678
    1234
    5
    678 
    						
    							Accenta/Optima Engineer’s Manual
    33
    Omit Allow & Double Knock
    LED Keypad:
    Press [CHIME] to toggle omit allow status on or off.
    Press [9] to turn all omit allow zones on.
    Press [0] to turn all omit allow zones off.
    • Press [OMIT] to enter into menu. LED 2 is on.
    • Press [2] to select Omit Allow.
    • Press zone number [1-8] to choose a particular zone.
    • Press the [zone number] or [CHIME] to toggle the omit allow
    status on or off. The appropriate LED is on when the zone is
    set up as omit allow. Default settings are off.
    • Press [RESET] twice to leave the menu.[OMIT]
    [2]
    [1-8] or [CHIME]
    [RESET]
    1234
    5
    678
    1234
    5
    678
    1234
    5
    678
    1234
    5
    678 
    						
    							Accenta/Optima Engineer’s Manual
    34
    P = Set Up Programs
    The panel uses three setting routines known as programs. Each program may have a different Exit Mode.
    These are 0 = Disabled, 1 = Timed, 2 = Final Door or 3 = Silent Timed. Zones can also be assigned different
    functions in different programs. Refer to the following diagram for the programming structure.
    Figure 16. Programming structure
    Programs
    P>Set Up Programs
    Select Program
    1, 2 or 3
    1 = Used Zones
    Zones 01-08 (Yes/No)
    2 = Timed Zones
    Zones 01-08 (Yes/No)
    3 = Inhibit ZonesZones 01-08 (Yes/No)
    4 = Entry Time
    6 = Exit Mode
    0 = DISABLED
    1 = TIMED
    2 = FINAL DOOR
    3 = SILENT TIMED 00-99 (multiplied by 10)
    5 = Exit Time
    00-99 (multiplied by 10)
    Notes on Zones
    For any program a zone cannot be both timed and inhibited. If a zone is selected as one it will be removed
    from the other.
    Zones in the timed and inhibited lists will be automatically added to the used list.
    Zones removed from the used list will be removed from the timed and inhibited lists.
    If a timed zone is left open on rearm, any inhibit zones will act as a timed zone during that set period.
    1 = Used Zones
    The zones on the system can either be programmed as Used or Unused. A zone that is programmed as unused
    by the engineer, is still available for chime or fire. Unused zones are primarily used for Part Set options. There
    must always be at least one used zone in program 1. The panel will enforce this if none are selected by auto-
    matically setting zone 1 to used. 
    						
    							Accenta/Optima Engineer’s Manual
    35
    LCD Keypad:
    NOTE:Pressing the number toggles the zone ON or OFF
    While in Engineer program mode, to set up zones as used,
    • Press [PROG] to give a choice of programs or press
    [up arrow] until P>Set Up Programs is displayed then press
    [SET].
    • Select program 1, 2 or 3.
    • The first screen to appear is Program Edit Used Zones.
    • Press [1] or [SET]. The first zone can now be set as used or
    unused.
    • To edit the other zones press [Number] or [up arrow] to go to
    a particular zone.
    • Press [RESET] three times to leave menu.
    LED Keypad:
    NOTE:Pressing the number toggles the zone ON or OFF
    While in Engineer program mode, to set up zones as used,
    • Press [PROG] to give a choice of programs. LED’s 1, 2 and 3 are
    flashing.
    • Select program [1, 2 or 3]. If program 1 is selected, LED 1 is ON.
    • Press [1] or [SET]. The first zone can now be set as used or
    unused. If used, then LED is on
    • To edit the other zones press [Number] to go to a particular zone.
    Default settings are on.
    • Press [RESET] three times to leave menu.[PROG]
    [1]
    [1] or [SET]
    [RESET]
    1234
    5
    678
    1234
    5
    678
    [Number]
    Programs (cont’d)
    [PROG]
    [1] or [SET]
    1: Descriptor 1: Descriptor1: Descriptor 1: Descriptor
    1: Descriptor
    Used: Used:Used: Used:
    Used:
    YES YESYES YES
    YES
    P>Select Program P>Select ProgramP>Select Program P>Select Program
    P>Select Program
    1 2 or 3 1 2 or 31 2 or 3 1 2 or 3
    1 2 or 3
    P>Program Edit P>Program EditP>Program Edit P>Program Edit
    P>Program Edit
      Used Zones   Used Zones  Used Zones   Used Zones
      Used Zones[Number]
    [Number] or [up arrow]
    2: Descriptor 2: Descriptor2: Descriptor 2: Descriptor
    2: Descriptor
    Used: Used:Used: Used:
    Used:
    NO NONO NO
    NO
    [RESET]
    P>Set Up P>Set UpP>Set Up P>Set Up
    P>Set Up
      Programs   Programs  Programs   Programs
      Programs
    1234
    5
    678
    1234
    5
    678
    1234
    5
    678 
    						
    							Accenta/Optima Engineer’s Manual
    36
    2 = Timed Zones
    A  zone programmed as Timed would be used to protect the main entry/exit door of the entry route.
    LCD Keypad:
    NOTE:Pressing the number toggles the zone ON or OFF
    While in Engineer program mode, to set up zones as timed,
    • Press [PROG] to give a choice of programs or press
    [up arrow] until P>Set Up Programs is displayed then press
    [SET].
    • Select program 1, 2 or 3.
    • The first screen to appear is Program Edit Used Zones.
    • Press [2] to enter into Timed Zones. The first zone can now be
    set as timed or untimed.
    • To edit the other zones press [Number] or [up arrow] to go to
    a particular zone.
    • Press [RESET] three times to leave menu.[PROG]
    [2]
    1: Descriptor 1: Descriptor1: Descriptor 1: Descriptor
    1: Descriptor
    Timed: Timed:Timed: Timed:
    Timed:
    YES YESYES YES
    YES
    P>Select Program P>Select ProgramP>Select Program P>Select Program
    P>Select Program
    1 2 or 3 1 2 or 31 2 or 3 1 2 or 3
    1 2 or 3
    P>Program Edit P>Program EditP>Program Edit P>Program Edit
    P>Program Edit
      Used Zones   Used Zones  Used Zones   Used Zones
      Used Zones[Number]
    [Number] or [up arrow]
    2: Descriptor 2: Descriptor2: Descriptor 2: Descriptor
    2: Descriptor
    Timed: Timed:Timed: Timed:
    Timed:
    NO NONO NO
    NO
    [RESET]
    P>Set Up P>Set UpP>Set Up P>Set Up
    P>Set Up
      Programs   Programs  Programs   Programs
      Programs
    LED Keypad:
    NOTE:Pressing the number toggles the zone ON or  OFF
    While in Engineer program mode, to set up zones as timed,
    • Press [PROG] to give a choice of programs. LED’s 1, 2 and 3 are
    flashing.
    • Select program [1, 2 or 3]. If program 1 is selected, LED 1 is ON.
    • Press [2] to enter into Timed Zones. The first zone can now be
    set as timed or untimed.
    • To edit the other zones press [Number] to go to a particular zone.
    Default settings are shown opposite.
    • Press [RESET] three times to leave menu.[PROG]
    [1]
    [2]
    [RESET]
    1234
    5
    678
    1234
    5
    678
    1234
    5
    678
    [Number]
    Programs (cont’d)
    1234
    5
    678
    1234
    5
    678 
    						
    All Honeywell manuals Comments (2)

    Related Manuals for Honeywell Accenta 8 User Manual