    							Accenta/Optima Engineer’s Manual
    47
    Appendix 1 - Event Log Messages
    Event Log
    Table 4. Event Log
    KEYPAD TEXT DESCRIPTION
    Zone events
    INTRUDER Intruder zone activated (opened)
    ENTRY START Entry time started
    ZONE OMITTED Zone has been omitted for one set period
    FIRE ZONE Fire zone activated (opened)
    ZONE EXCLUDED Zone has been omitted for one set period
    User Events
    CODE ENTRY User has entered code
    SET PROGRAM User has set the system with program 1, 2 or 3
    SYSTEM UNSET User has unset the system
    System Events
    CLEAR LOG Event log has been cleared
    NV M INIT Panel was set to factory default condi ti ons
    START UP Panel was cold started
    PA PA zo ne  acti vate d
    RK P  PA Remote K eypad PA enabled
    DURESS CODE Duress code used to set or unset the system
    ENTRY TIMEOUT Ti meout alarm after entry ti me has expi red
    SYSTEM REARM System rearmed after an alarm
    CODE TAMPER Invalid user code was entered
    USER RESET User has reset the system
    ENGR RES E T Engi neer has reset the system
    ENG ACCESS Entering engineer program mode
    ENG FINISH Leaving engineer program mode
    OLD  TIME Old ti me i ndi cated before change
    NEW TIME New ti me i ndi cated after change
    OLD  D ATE Old date i ndi cated before change
    NEW DATE New date indicated after change
    MAINS FAIL Mains power supply failure
    MAINS OK Mains power supply restored
    LOOP TAMPER Tamper alarm indicated 
    						
    							Accenta/Optima Engineer’s Manual
    48 
    						
    							Accenta/Optima Engineer’s Manual
    49
    Appendix 2 - Library
    Attic
    Back Door
    Basement
    Bathroom
    Bedroom 1
    Bedroom 2
    Bedroom 3
    Conservatory
    Dining Room
    Fire Zone
    Front Door
    Garage
    Hall
    Library
    Kitchen
    Landing
    Living Room
    Lounge
    Patio
    Porch
    Stairs
    Study
    Utility Room
    Window 1
    Window 2
    Window 3 
    						
    							Accenta/Optima Engineer’s Manual
    50 
    						
    							Accenta/Optima Engineer’s Manual
    51
    Servicing Organisation Details
    Servicing Organisation name:
    Telephone number:
    Date of Installation:
    Account Number:
    Parts
    8SP399AAccenta mini panel with LCD keypad
    8SP400AAccenta mini panel with LED keypad
    8EP396AOptima compact panel
    8SP419AAccenta panel metal enclosure with LCD keypad
    8SP420AAccenta panel metal enclosure with LED keypad
    8EP417A Accenta LCD remote keypad
    8EP416 Accenta LED remote keypad
    8EP276Informa
    8EP289Extension speaker
    IS215T 12 meter PIR
    Servicing/Parts
    Resistance(Ω) Are a  pro te c tio n a nd e quipme nt us e d (e g  PIR ,  Co nta c ts )
    Zo ne  1
    Zo ne  2
    Zo ne  3
    Zo ne  4
    Zo ne  5
    Zo ne  6
    Zo ne  7
    Zo ne  8
    Table 5. Zones and Resistance 
    						
    							Accenta/Optima Engineer’s Manual
    52 Honeywell Security (UK 64)
    Newhouse Industrial Estate
    Motherwell
    Lanarkshire
    ML1 5SB
    UK
    © Copyright Honeywell Security IE1-0040  Rev 1.0
    Engineer Program Mode [PROG] [9] [9] [9] [9].  To exit Engineer Program Mode [RESET]
    0 = Walk Test
    1 = Alarm Test1 = Bell
    2 = Strobe
    3 = Sounder
    2 = Test Outputs1 = Fire
    2 = PA
    3 = Intruder
    4 = Set
    5 = Abort
    3 = Set up System FlagsFlag 11 = Silent PA
    2 = RKP PA
    3 = Engineer Reset
    4 = PA User Reset
    5 = Fire User Reset
    6 = Bells in Fire
    7 = Zone 7 Fire
    8 = Zone 8 Fire
    Flag 2
    1 = Single Key Set
    2 = Strobe On Set
    Flag 3
    System and Software
    Version
    4 = Set Up Time and Date
    6 = Set Up Zone Names
    7 = Set Up Timers
    1 = Bell Time00 - 99 minutes
    2 = Bell Delay
    00 - 99 minutes
    3 = Rearm Count
    0 = No rearms
    1 - 8 = number of rearms
    9 = Always rearm
    8 = Set Up Codes1 = User 1 (Manager)
    2 = User 2 (deletable)
    3 = Duress (deletable)
    4 = Engineer
    4-digit code
    C = View Event Log
    1 = LCD
    2 = LED
    O = Omit Allow &
           Double Knock
    1 = Double Knock
    2 = Omit Allow
    P = Set Up Programs
          (1, 2 or 3)1 = Used Zones (1-8) 
    2 = Timed Zones
    3 = Inhibit Zones
    4 = Entry Time (00-99 seconds)
    5 = Exit  Time (00-99 seconds)
    6 = Exit Mode 
    						
    All Honeywell manuals Comments (2)

    Related Manuals for Honeywell Accenta 8 User Manual