Home > Panasonic > Camera Accessories > Panasonic Multi Hybrid Control Panel Aw Rp505 Operating Instructions

Panasonic Multi Hybrid Control Panel Aw Rp505 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Multi Hybrid Control Panel Aw Rp505 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-19-
    INSTALLATION OF PAN/TILT HEAD
    Have a strong enough wire rod head and fasten it
    securely to a firm board, such as of the ceiling.
    Hole for wire rod to
    prevent the head
    from falling
    • Install the pan/tilt head after carefully reading the
    Operating Instructions for Pan/tilt Head.
    • Have four hex bolts (M6 x 4) ready for mounting the
    pan/title head.  Select bolts of a length appropriate to
    the material and structure of the mounting base and
    the overall weight applied to it.  Fasten the bolts
    securely with plain washers, spring washers, and hex
    nuts.  If the bolts are not securely tightened, the pan/tilt
    head might fall to cause injuries or accidents.  In case
    of suspending the pan/tilt head, locally purchase a
    wire rod strong enough to hold the pan/tilt head, cam-
    era, and lenses, pass it through the wire hole opened
    in a firm board, such as of the ceiling, for example,
    and fasten it securely.
    • The switches on the pan/tilt head have been preset
    before shipment from the factory on the assumption
    that the pan/tilt head would be suspended from the
    ceiling.  If the pan/tilt head is mounted on a board, for
    example, be sure to shift the mounting direction
    switches on the pan/tilt head.  Unless this is done,
    pan/tilt directions will be reversed and pan/head oper-
    ation limiter data cannot be properly stored in the
    memory.  For details on shifting these switches, refer to
    the Operating Instructions for Pan/tilt Head. 
    						
    							-20-
    SW 2 SW 1 SW 3
    SW 2 SW 1 DESKTOP
    HANGING
    • Changing Switch Settings on Pan/tilt Head 
    qRemove the cover from the pan/tilt head.
    * Be careful of the Tally Indicator wire.
    wShift the mounting direction switches (SW1, SW2) on
    the pan/tilt head depending on whether the head is
    suspended from the ceiling or mounted on the floor.
    They are originally set for suspended installation.
    * Do not change the original set position of SW3.  If it is
    changed, no operation can be controlled from the con-
    trol panel.
    Tally Indicator
    ePlace the cover back on the pan/tilt head.
    * Be sure not to trap the wires.
    • If the pan/tilt head is connected to the multiport hub
    with a cable longer than 300 meters, set the cable
    compensation switch on the pan/tilt head to the ON
    position in advance.  If the distance between the
    pan/tilt head and the control panel is shorter than 300
    meters, keep the switch in the original position (OFF).
    For details on shifting the switch, refer to the figure
    below or the Operating Instructions for Pan/tilt Head. 
    						
    							-21-
    ON
    OFF
    • Shifting Cable Compensation Switch on Pan/tilt
    Head
    If the distance from the control panel to the pan/tilt
    head is longer than 300 meters, set the cable compen-
    sation switch to the ON position by observing the fol-
    lowing procedure.
    qRemove the controller connection panel from the
    pan/tilt head.
    * Be careful of the wires.
    wShift the cable compensation switch on the inner side
    of the controller connection panel of the pan/tilt head to
    the ON position.
    ePlace the controller connection panel back on the
    pan/tilt head.• How to Mount the Lens
    • Turn the lens lock ring knob fully counterclockwise.
    • If the lens mount has a cap, remove the cap.
    • With the lens positioning pin up, mount the lens.
    • Turn the lens lock ring knob clockwise till the lens is
    securely fastened. 
    						
    							-22-
    CONNECTIONS• Before making any connection, switch off all the com-
    ponents of the system.
    • Use the Control Panel AC Adaptor AW-PS301 (option-
    al), Multiport Hub AC Adaptor AW-PS505 (optional) and
    Pan/tilt Head AC Adaptor AW-PS300 (optional).• Use the Multiport Hub AW-HB505, the Pan/tilt Head
    AW-PH300 and the Color Video Camera AW-E560.
    (The Color Video Camera WV-E550 cannot be used.)
    To connect the pan/tilt head to the camera, the Camera
    Cable AW-CA20T15 (optional) is necessary.
    • Locally purchase a DC cable with a nominal cross sec-
    tion of 1.25 mm
    2or larger that meets the UL specifica-
    tions, and connect the Pan/tilt Head AW-PH300 to the
    Pan/tilt Head AC Adaptor AW-PS300 with that cable.
    The maximum distance between the pan/tilt head and
    pan/tilt head AC adapter is 30 m.
    • Connect the Multiport Hub AC Adapter AW-PS505 to
    the Multiport Hub AW-HB505.
    • Connect the AC Adaptor AW-PS301 to the control
    panel and clamp the DC cable of the AC adapter to the
    cord clamp on the control panel.
    • Connect the Pan/tilt Head AW-PH300 to the Color
    Video Camera WV-E560 with the Camera Cable AW-
    CA20T15.
    DC Cord Cord Clamper
    Control Panel 
    AC Adaptor
    AW-PS301 
    						
    							-23-
    ITEM(AWC) UP(ABC)PAGEDOWN
      (BAR)IRIS
    G/L  INVIDEO  OUT
    ZOOM/FOCUS
    REMOTEVD
    VIDEO/RGB VBS/HD
        75ON
    OFF
    CONTROL
    EXT DC INSEE MANUALCAUTION
    • Connect the iris control cable of the motor-driven zoom
    lens to the camera and the remote (zoom/focus control)
    cable to the pan/tilt head.  If the remote (zoom/focus
    control) cable of the motor-driven zoom lens is con-
    nected to the camera, the lens cannot be controlled.• Connect the control panel to the multiport hub with the
    three coaxial cables (video signal, G/L signal, camera
    control signal)  and one 10BASE-T straight cable
    (pan/tilt head control signal).  The maximum distance
    between the control panel and pan/tilt head is 10
    meters for coaxial cables 5C-2V and 10BASE-T straight
    cable (UTP category 5 or equivalent).
    • Connect the pan/tilt head to the multiport hub with the
    three coaxial cables (video signal, G/L signal, camera
    control signal) per pan/tilt head and one 10BASE-T
    straight  cable (pan/tilt head control signal).  The maxi-
    mum distance between the control panel and pan/tilt
    head is 500 meters per pan/tilt head for coaxial cables
    5C-2V and 10BASE-T straight cable (UTP category 5 or
    equivalent).
    • For further details on connecting the individual devices,
    To Lens Interface ConnectorTo Iris ConnectorIris Control
    Cable Remote (Zoom/Focus
    Control) Cable 
    						
    							-24-
    CAMERA
    CONTROL OUTCAMERA
    CONTROL IN VIDEO OUTPAM/TILT
    CONTROL OUTPAM/TILT
    CONTROL IN
    S-VIDEO OUT VIDEO
    IN
    G/L
    OUTG/L
    IN
    CAMERA
    CONTROL OUTVIDEO OUTPAM/TILT
    CONTROL OUT
    S-VIDEO OUT VIDEO
    IN
    G/L
    OUT
    CAMERA
    CONTROL OUTVIDEO OUTPAM/TILT
    CONTROL OUT
    S-VIDEO OUT VIDEO
    IN
    G/L
    OUT
    CAMERA
    CONTROL OUTVIDEO OUTPAM/TILT
    CONTROL OUT
    S-VIDEO OUT VIDEO
    IN
    G/L
    OUT
    CAMERA
    CONTROL OUTVIDEO OUTPAM/TILT
    CONTROL OUT
    S-VIDEO OUT VIDEO
    IN
    G/L
    OUT
    4
    3
    2
    1 5
    DC12V  IN
    TO CAMERA PAM/TILT HEAD
    TO CONTROL PANELPREVIEW OUT
    SEE MANUAL
    PAGEITEM(AWC) UP(ABC)DOWN  (BAR)IRIS
    G/L  INVIDEO  OUT
    ZOOM/FOCUS
    REMOTEVD
    VIDEO/RGB VBS/HD
        75ON
    OFF
    CONTROL
    EXT DC INSEE MANUALCAUTION
    AC IN
    LAMP AC OUT
    MIN  250W
    MAX 500W
    OPTION   SW
    CONTROL OUTOPTION   SW
    CONTROL INLAMP
    CONTROL
    OP SC
    DC 15V
    OUT- +
    TALLYDC12V IN
    AUX  CONTROL  IN1 2 3 4
    5 
    PREVIEW IN OUT G/L  OUTPREVIEW MONITOR OUT
    CONTROL CONTROL  OUTPAN/TILT CAMERA
    TD  MULTI  PORT  HUBG / L  IN
    Connecting the control panel to Color Video Camera
    (AW-E560), Pan/tilt Head (AW-PH300), and Pan/tilt
    Head AC Adapter (AW-PS300)
    Pan/tilt Head
    AW-PH300Color Video Camera
    AW-E560To Servo Control Zoom Lens
    IRIS CONTROL
    Camera Cable 
    AW-CA20T15
    Multiport Hub  AW-HB505
    Pan/tilt Head AC Adaptor AW-PS300PREVIEW OUT
    G/L THROUGH OUT
    G/L IN
    PAN/TILT CONTROLZOOM/FOCUS
    CONTROL
    CAMERA CONTROL
    GEN-LOCK
    VIDEO
    DC+15V 
    						
    							-25-
    S-VIDEO VIDEO
    PREVIEW
    VIDEO
    VIDEO
    CONTACT PAN/TILT
    CONTROL
    PAN/TILT
    CONTROL CAMERA CONTROL
    CAMERA CONTROL SYSTEM
    TALLY
    G/L
    G/L  DC15V
    OPTION
    SWITCH 
    CONTROL
    PREVIEW
    VIDEO
    G/L
    ONPOWER
    OFFPOWER
    O    I
    FUSE(POWER)
    3.15AFUSEFUSE
    Option UnitSEG, Switcher etc.
    POWERON
    OFF
    Color  Monitor  WV-CM   1470
    PUSH
    POWERON
    OFF
    Color  Monitor  WV-CM   1470
    PUSH
    ZOOM/FOCUS CONTROL
    IRIS CONTROL
    LAMPCONTROL
    SPEED FOUCUS PA N  /  T I LT
    ZOOMTELE
    WIDEFA R
    LEFT RIGHTUP
    DOWN
    NEAR
    DEFON
    OFF ON
    OFF
    POWEROPERATE
    IRISCAM
    CONT
    BAR
    CAMMODEGAIN AWC
    SCENE
    FILEABC
    AT W
    A
    B
    AUTO/AIWELC LOW MID
    MANUON SC H
    OFF HIGHT AGC
    OFF 1 / 100SHUTTER
    ON
    OFF
    LAMPMEMORY
    ON
    OFF AUTO
    MANUON
    OFFON
    OFFON
    OFF ON
    OFFON
    OFF
    WIP
    EXT ND OPH / F
    1 .
    2 .
    3 .
    4 .
    G/L PHASE
    PRESET
    T.PEDMulti Hybrid Control Panel AW-RP505
    154 3 2 154 3 2
    2 1345
    67891090¡  180¡
    0¡     270¡
    LEVELTALLYCONTROL
    POWER
    1
    YC2
    YC3
    YC4
    YC5
    YC
    OFF ON
    CABLE  COMP
    Multl  Port  Hub  AW-H8505
    POWERON
    OFF
    Color  Monitor  WV-CM   1470
    PUSH
    POWERON
    OFF
    Color  Monitor  WV-CM   1470
    PUSH
    POWERON
    OFF
    Color  Monitor  WV-CM   1470
    PUSH
    POWERON
    OFF
    Color  Monitor  WV-CM   1470
    PUSH
    Signal Generator
    Control Panel
    AC Adaptor
    AW-PS301 Pan/tilt Head AC
    Adapter
    AW-PS300 Halogen
    LampColor Monitor
    (75Wterminator)
    Multi Hybrid Control Panel AW-RP505 Color Camera
    WV-E550A
    AW-E560
    Camera Cable
    AW-CA20T15
    Multiport Hub
    AW-HB505
    Preview Color Monitor Servo Control
    Zoom Lens
    Unnecessary if no
    halogen lamp is used. Unnecessary if
    no optional unit is
    connected.Multiport Hub
    AC Adabtor
    AW-PS505
    • Example of System Configuration 
    						
    							-26-
    OPERATING PROCEDURES1.Power
    Press the power switch on each pan/tilt head AC
    adapter and the power switch on the multiport hub AC
    adapter to the ON position, then press the power
    switch on the multiport hub to the ON position.  Finally,
    press the power control switch on the multi hybrid con-
    trol panel to the ON position.
    2. Pan/tilt Limiter Setting for Each
    Pan/tilt Heads
    If there are obstacles around the pan/tilt head, set the
    limiters to limit the operating range (pan left and right
    ends, tilt up and down ends) of the pan/tilt head.
    Note:The switches on the pan/tilt head have been pre-
    set before shipment from the factory on the
    assumption that the pan/tilt head would be sus-
    pended from the ceiling.  If the pan/tilt head is
    mounted on a board, for example, be sure to shift
    the mounting direction switches on the pan/tilt
    head.  Unless this is done, pan/tilt directions will be
    reversed and pan/head operation limiter data can-
    not be properly stored in the memory.  For details
    on shifting these switches, refer to INSTALLATION
    OF PAN/TILT HEAD at page 19 or the Operating
    Instructions for Pan/tilt Head.qSelect a pan/tilt head with the CONTROL switch.
    wLeft Panning Limiter
    Turn the pan/tilt head to the desired left panning limit
    with PAN/TILT Lever #8, keep MEMORY Switch @7
    depressed, and simultaneously press buttons [1] and
    [6] of PRESET Switch @8for 5 seconds or more.  When
    the desired limit has been set, button [5] of PRESET
    Switch @8lights.
    To reset the limit, keep the MEMORY switch @7
    depressed, and simultaneously press buttons [1] and
    [6] of PRESET Switch @8again for 5 seconds or more.
    When the set limit is reset, button [10] of PRESET
    Switch @8lights.
    MEMORY
    PRESET
    2 1345
    678910
    Up tilting limiterPreset position selection switch
    Left panning
    limiterLights on
    completion
    of setting.
    Preset
    memory
    switchLights on 
    completion 
    of resetting
    Down tilting limiterRight panning 
    limiter 
    						
    							-27-
    eRight Panning Limiter
    Turn the pan/tilt head to the desired right panning limit
    with PAN/TILT Lever #8, keep MEMORY Switch @7
    depressed, and simultaneously press buttons [4] and
    [9] of PRESET Switch @8for 5 seconds or more.  When
    the desired limit has been set, button [5] of PRESET
    Switch @8lights.
    To reset the limit, keep the MEMORY Switch @7
    depressed, and simultaneously press buttons [4] and
    [9] of PRESET Switch @8again for 5 seconds or more.
    When the set limit is reset, button [10] of PRESET
    Switch @8lights.
    rUp Tilting Limiter
    Turn the pan/tilt head to the desired up tilting limit with
    PAN/TILT Lever #8, keep MEMORY Switch @7
    depressed, and simultaneously press buttons [2] and
    [3] of PRESET Switch @8for 5 seconds or more.  When
    the desired limit has been set, button [5] of PRESET
    Switch @8lights.
    To reset the limit, keep the MEMORY switch @7
    depressed, and simultaneously press buttons [2] and
    [3] of PRESET Switch @8again for 5 seconds or more.
    When the set limit is reset, button [10] of PRESET
    Switch @8lights.
    tDown Tilting Limiter
    Turn the pan/tilt head to the desired down tilting limit
    with PAN/TILT Lever #8, keep MEMORY Switch @7
    depressed, and simultaneously press buttons [7] and[8] of PRESET Switch @8for 5 seconds or more.  When
    the desired limit has been set, button [5] of PRESET
    Switch @8lights.
    To reset the limit, keep the MEMORY switch @7
    depressed, and simultaneously press buttons [7] and
    [8] of PRESET Switch @8again for 5 seconds or more.
    When the set limit is reset, button [10] of PRESET
    Switch @8lights.
    ySelect the pan/tilt heads with the CONTROL switch,
    one at a time, and set the operating range limiters of
    each pan/tilt head.
    3. Cable Compensation Settings,
    Genlock, and Total Pedestal
    Adjustments for Each Cameras and
    Various Switch Settings1) After selecting a camera with the CONTROL Switch
    @2, set the CAM CONT Switch rto the ON position.
    Note:When the CAM CONT Switch ron the multi
    hybrid control panel is set to the ON position, the
    switch settings of the multi hybrid control panel are
    sent to the camera to update its settings.  Do not
    set the CAM CONT Switch rto the ON position
    except when changing the camera settings.  If
    another camera is selected with the CONTROL
    Switch @2while the CAM CONT Switch ris in the 
    						
    							-28-
    POWER
    1
    YC2
    YC3
    YC4
    YC5
    YC
    OFF ON
    CABLE  COMP
    Multl  Port  Hub  AW-H8505
    Waveform Monitor
    Vector ScopeColor Monitor
    (75Wtermination)CABLE COMP C Control  CABLE COMP Y Control 
    Multiport Hub
    AW-HB505
    ON position, the settings of the selected camera
    will be similarly changed.  Set the CAM CONT
    Switch rback to the OFF position before chang-
    ing one camera for another with the CONTROL
    Switch @2.
    2) Adjust the cable compensation, genlock, and total
    pedestal of the selected camera.
    • Cable Compensation
    Signal degradation due to cable length between the multi-
    port hub and the pan/tilt head can be compensated for.
    qIf the cable length from the pan/tilt head to the multi-
    port hub is longer than 300 meters, set the cable com-
    pensation switch on the pan/tilt head to the ON posi-
    tion.  For details, refer to INSTALLATION OF PAN/TILT
    HEAD at page 19 or the Operating Instructions for
    Pan/tilt Head.
    wConnect a waveform monitor or a vectorscope to the
    video output connector on the control panel for the
    corresponding the camera pan/tilt head number ([1] to
    [5]), set the video output connector on the multiport
    hub, set the mode switch to the BAR position, then
    observe the color bar signals.
    eAdjust the Y (luminance) signal level with the CABLE
    COMP Y control for the corresponding camera pan/tilt
    head number ([1] to [5]), then adjust the CABLE
    COMP Y control then adjust the C (chrominance) sig-
    nal level with CABLE COMP C control. Repeat this untilthe video output of the multiport hub is adjusted as
    shown in the figure below.
    Note:Turning CABLE COMP Y control changes not
    only the Y (luminance) signal level but also the
    video signal levels as a whole. 
    						