Home > Panasonic > Controller > Panasonic System Controller Wv Cu161 Operating Instructions

Panasonic System Controller Wv Cu161 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic System Controller Wv Cu161 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    SYSTEM CONNECTION
    The WV-CU161 can be connected with a camera, a video monitor and a Time Lapse VCR. A typical connection example is
    shown below.
    Basic System Connection
    WV-CS854
    WV-CU161
    Time Lapse VCR
    System Controller WV-CU123467890
    5SHIFT OPERATE ALARM
    RESET
    RESET SUSPEND
    CAMERA
    SETUPPATROL
    PLAY
    PROGRAM
    PRESET CAMERA
    FUNCTIONSETUP
    ESC HOME
    SET PRESET
    WIDE TELE NEAR AUX1B/W AUTO
    WIPER
    AUX2DEFUP
    DOWNR L
    FA R
    FOCUS
    IRIS
    CLOSS OPENPROGRAMALARMIRIS RESETAUTO FOCUS
    Video Monitor
    Camera Site
    Control Site
    900 m or less (Using RG-59U,
    BELDEN 9259 or equivalent cable)
    (Coaxial Multiplex Communication)
    ALARM INPUT/OUTPUT
    (See page 14)CAMERA
    IN
    VIDEO
    OUT
    VIDEO IN
    VIDEO OUTD ATA
    COAX
    RS485
    Note:Refer to the operating instructions of each system component for connection and operation. 
    						
    							12
    Connection with a Video Switcher
    Connected with a video switcher, the WV-CU161 allows you to control multiple combination cameras.
    WV-CS854
    Video SwitcherCamera HousingCamera
    Receiver
    R
    System Controller
    WV-CU161
    System Controller WV-CU123467890
    5SHIFT OPERATE ALARM
    RESET
    RESET SUSPEND
    CAMERA
    SETUPPATROL
    PLAY
    PROGRAM
    PRESET CAMERA
    FUNCTIONSETUP
    ESC HOME
    SET PRESET
    WIDE TELE NEAR AUX1B/W AUTO
    WIPER
    AUX2DEFUP
    DOWN L
    FA R
    FOCUS
    IRIS
    CLOSS OPENPROGRAMALARMIRIS RESETAUTO FOCUS
    Video Monitor Time Lapse VCR
    D ATA
    COAX
    RS485
    CAMERA
    IN
    VIDEO
    OUT
    VIDEO IN
    VIDEO OUT
    Notes:
    • Only the camera of the channel selected the Video Switcher can be controlled by the WV-CU161. Two or more cameras
    cannot be controlled simultaneously. It is not possible to operate two or more cameras at the same time during alarm acti-
    vated control.
    • Refer to the operating instructions of each system component for connection and operation. 
    						
    							13
    RS-485 Site Communication Connection via Codec for Camera
    Distance of 1 200 m (4 000 ft) or More
    WV-CS854AV Codec
    AV Codec
    R
    System Controller
    WV-CU161
    System Controller WV-CU123467890
    5SHIFT OPERATE ALARM
    RESET
    RESET SUSPEND
    CAMERA
    SETUPPATROL
    PAY
    PROGRAM
    PRESET CAMERA
    FUNCTIONSERUP
    ESC HOME
    SET PRESET
    WIDE TELE NEAR AUX1B/W AUTO
    WIPER
    AUX2DEFUP
    DOWN L
    FA R
    FOCUS
    IRIS
    CLOSS OPENPROGRAMALARMIRIS RESETAUTO FOCUS
    Video Monitor
    DATA PORT
    DATA PORT VIDEO OUT
    CAMERA IN
    VIDEO OUT RS-485 Cable
    Coaxial Cable
    RS485 DATA
    TERM LINECOAX
    RS485 4
    2 ON
    OFFR TA B A B G
    Public lines
    Video signal
    RS-485 signal
    Notes:
    • Refer to the operating instructions of each system component for connection and operation.
    • If public line is busy, it may cause instability of the system operation. 
    						
    							14
    Connection with a Time Lapse VCR
    Connect the time lapse VCR as shown in the example below.
    Make sure the polarity of the buzzer matches the terminal.
    Connect the positive (+) terminal of the buzzer to the Alarm Output Terminal.
    The Alarm Output Terminal is an Open Collector terminal with a capacity of 16 V DC, 100 mA or less.
    (1) Connect the buzzer as shown below if its rating lies within the capacity of the Alarm Output Terminal.
    (2) Use an external relay unit as shown below if the buzzer rating exceeds the capacity of the Alarm Output Terminal.
    GNDALARM IN
    ALARM OUT1 2
    G 3 4
    Relay
    +12 V NC
    NO
    Alarm Indicator etc.
    Time Lapse VCR
    1 ALARM IN
    2 ALARM OUT
    G ROUND
    3 RECOVER IN
    4 RESET OUT
    NC: Normally Closed Contact
    NO: Normally Open Contact
    24ALARM
    IN 1
    COM2
    ALARM
    RESET IN 3
    ALARMRECOVER OUT4
    ALARM
    OUT 5
    135
    Cable-loss Compensation Setting
    The maximum allowable cable length of the system is approximately 900 m (3 000 ft).
    See the diagram below and setup the cable-loss compensation switch for each unit accordingly. (See page 19)
    Camera WV-CU161
    A m (A ft)
    
       0 (0)≤ A < 400 (1 300)→ S
      400 (1 300)≤ A < 700 (2 300)→ M
      700 (2 300)≤ A < 900 (3 000)→LCable compensation 
    parameter in WV-CU161
    Setup menu Cable length (with RG-59U
    BELDEN 9259 or equivalent)
    Unit: m (ft) 
    						
    							15
    Internal Diagram
    RS-485 Terminal
    Control data is transmitted and received to and from other
    peripherals. Use a data grade, double-shielded, twisted
    pair cable, suitable for the RS-485. Cable length may be
    extended up to 1 200 m (4 000 ft).
    TR
    RS485
    A B A B G
    GND
    5
    TB TA RB RA4321
    RA  TB  4
    3
    2
    1
    TA 
    RB  
    						
    							16
    SETUP MENU
    The Setup menu has four main submenus: Alarm Setup, System Setup, Preset Data Load, and Communication.
    All of these main menus are further divided into submenus.
    ALARM SETUP*1
    ALARM TERMINAL
    SYSTEM SETUP*2
    PRESET DATA LOAD*3
    PRESET DATA LOAD CAM 1
    PRESET DATA LOAD CAM 2
    PRESET DATA LOAD CAM 3
    PRESET DATA LOAD CAM 4
    PRESET DATA LOAD CAM 5
                                       PRESET DATA LOAD CAM 6                           
    PRESET DATA LOAD CAM 7
    PRESET DATA LOAD CAM 8
    COMMUNICATION*4
    SETUP MENU
    *1 To set the alarm operation mode when an alarm is activated.
    *2 To set the system mode.
    *3 To download the preset data from a combination camera.
    To upload the preset data after downloading it.
    *4 To setup RS-485 site communication. This item appears only for RS-485 site communication.
    In case of coaxial multiplex communication, it does not appear. 
    						
    							17
    WV-CU161 SETUP MENU *.**
       ALARM SETUP
       SYSTEM SETUP
       PRESET DATA LOAD
       COMMUNICATION
    Note:The COMMUNICATION parameter appears when the
    data switch is set to RS-485 (See page 9).
    Key Functions on the Setup
    Menu
    SHIFT button + CAMERA SETUP/SETUP/PROGRAM
    button:
    To display the program menu. Press CAMERA SETUP
    /SETUP button for 2 seconds or more after pressing the
    SHIFT button.
    SHIFT
    CAMERA
    SETUP
    SETUP
    PROGRAM
    PRESET/SET/PROGRAM PRESET button:
    To execute modes and parameters.
    To enter a submenu for an item marked  .
    PROGRAM
    PRESETSET PRESET
    HOME/ESC button:
    To return to the previous menu.
    ESC HOME
    Up: To select modes.
    Down: To select modes.
    Left: To decrease the parameter.
    Right: To increase the parameter.
    DOWN LRUP
    LR
    UP
    DOWNR
    UP
    DOWN LR
    •Joystick Controller
    •Closing Setup Menu
    Press the SHIFT button, and then press the PRESET/
    SET/PROGRAM PRESET button for 2 seconds or more.
    The LED next to the button goes off.
    Notes:
    • When the power of the WV-CU161 is turned off
    before completing the setup, the new values do not
    become valid. The saved values remain valid until
    new values are saved.
    • After parameters have been changed, return to the
    Setup menu, and then turn the power off.
    Alarm Setup
    1. Display the Setup menu.
    2. Select ALARM SETUP by moving the joystick up or
    down.
    3. Press the PRESET/SET/PROGRAM PRESET button.
    The ALARM SETUP menu appears on the monitor as
    shown below.
    • For using alarm input/output terminal and alarm
    recover input/output terminal
          ALARM SETUP
       ALARM DISPLAY ON
       SITE ALARM    ON
       TERM.ALARM    ON
       ALARM OUTPUT  10S
       ALARM BUZZER  ON
       ALARM PRESET  –
    Displaying the Setup Menu
    1. Check that the camera, the monitor and peripherals are
    connected correctly and securely.
    2. Switch all the system components on.
    The operate indicator of the WV-CU161 lights up.
    The picture of the camera appears on the monitor.
    3. Press the SHIFT button, and then press the CAMERA
    SETUP/SETUP button for 2 seconds or more.
    4. The SETUP MENU appears. 
    						
    							18
    (1) Alarm Display Setting
    This item lets you select whether or not the message
    ALARM on the monitor when the alarm is activated.
    1. Display the ALARM SETUP menu.
    2. Select ALARM DISPLAY by moving the joystick up or
    down.
    3. To have ALARM displayed, select ON for the ALARM
    DISPLAY parameter. Otherwise select OFF by moving
    the joystick to the right or left.
    The initial factory setting is ON.
    Note:The display time differs depending on (4) Alarm
    Output Setting.
    (2) Site Alarm Setting
    This item lets you enable or disable the camera site alarm.
    1. Display the ALARM SETUP menu.
    2. Select SITE ALARM by moving the joystick up or down.
    3. Select SITE ALARM ON or OFF by moving the joystick
    to the right or left.
    The initial factory setting is ON.
    (3) Terminal Alarm Setting
    This item lets you enable or disable the alarm signal from
    the alarm connector.
    1. Display the ALARM SETUP menu.
    2. Select TERM.ALARM by moving the joystick up or
    down.
    3. Select TERM.ALARM ON or OFF by moving the joystick
    to the right or left.
    The initial factory setting is ON.
    (4) Alarm Output Setting 
    This item lets you select an alarm operation duration when
    the alarm is activated.
    It determines the following. (The selected duration applies
    to each alarm operation.)
    • The length of time that ALARM is displayed on the mon-
    itor (ALARM DISPLAY ON mode).
    • The length of time the alarm is output to external
    devices (from the ALARM OUTPUT connector).
    • The length of time the buzzer sounds (ALARM BUZZER
    ON mode).
    1. Display the ALARM SETUP menu.
    2. Select ALARM OUTPUT by moving the joystick up or
    down.3. Select the desired alarm output duration, 1S-30S, 40S
    50S 1MIN 2MIN, 3MIN, 4MIN, 5MIN EXT, or OFF by
    moving the joystick to the right or left.
    The initial factory setting is 10S.
    EXT:The alarm signal continues to be output from the
    alarm output connector till the alarm is reset. The
    alarm is not automatically reset.
    1S-5MIN:The alarm signal is supplied from the alarm
    output connector only for the set time. The alarm is
    automatically reset after the set time. (The ALARM
    indicator changes from blinking to steady light.)
    OFF:No alarm output signal is supplied. (The alarm is
    deactivated.)
    (5) Alarm Buzzer Setting
    This item lets you select whether or not the alarm buzzer
    sounds when the alarm is activated.
    1. Display the ALARM SETUP menu.
    2. Select ALARM BUZZER by moving the joystick up or
    down.
    3. Select ALARM BUZZER ON or OFF by moving the joy-
    stick to the right or left.
    The initial factory setting is ON.
    Note:The alarm buzzer time differs depending on (4) alarm
    output setting.
    (6) Alarm Preset Setting
    This item lets you select picture preset numbers in preset-
    ting combination camera positions when the alarm is acti-
    vated.
    • For using alarm input/output terminal and alarm recover
    input/output terminal.
          ALARM SETUP
       ALARM DISPLAY ON
       SITE ALARM    ON
       TERM.ALARM    ON
       ALARM OUTPUT  10S
       ALARM BUZZER  ON
       ALARM TERMINAL
    • For using alarm input terminals 1-4
    1. Display the ALARM SETUP menu.
    2. Select ALARM PRESET by moving the joystick up or
    down.
    3. Move the joystick to the right or left to select the
    desired preset numbers of the picture on the moni-
    tor in the range of 1-64 or [–] if no preset numbers
    are assigned.
    The initial factory setting is – (No assignment).
    1-64:Preset numbers
    –:No assignment
    Note:ALARM PRESET is available only when a
    combination camera is connected.
          ALARM SETUP
       ALARM DISPLAY ON
       SITE ALARM    ON
       TERM.ALARM    ON
       ALARM OUTPUT  10S
       ALARM BUZZER  ON
       ALARM PRESET  – 
    						
    							19
          ALARM SETUP
       ALARM DISPLAY ON
       SITE ALARM    ON
       TERM.ALARM    ON
       ALARM OUTPUT  10S
       ALARM BUZZER  ON
       ALARM TERMINAL
    System Setup
    1. Display the Setup menu.
    2. Select SYSTEM SETUP by moving the joystick up or
    down.
    3. Press the PRESET/SET/PROGRAM PRESET button.
    The SYSTEM SETUP menu appears on the monitor as
    shown below.
          SYSTEM SETUP
         CABLE COMP    S
         SWITCH BUZZER ON
    • For using alarm input terminals 1-4
    1. Display the ALARM SETUP menu.
    2. Select ALARM TERMINAL by moving the joystick up
    or down.
    3. Press the PRESET/SET/PROGRAM PRESET button.
    The ALARM TERMINAL screen appears as shown
    below.
         ALARM TERMINAL
        ALARM     PRESET
          1          -
          2          -
          3          -
          4          -
    4. Select the alarm terminal number by moving the joy-
    stick up or down.
    5. Move the joystick to the right or left to select the
    desired preset numbers of the picture on the moni-
    tor in the range of 1-64, or [–] if no preset numbers
    are assigned.
    The initial factory setting is – (No assignment).
    1-64:Preset numbers
    –:No assignment
    6. To return to the previous menu, press the
    HOME/ESC button.
    Notes:
    • ALARM TERMINAL is available only when a  combi-
    nation camera is connected.
    • If the camera has the Preset Alarm ON/OFF mode,
    set it to OFF.
    (1) Cable Compensation Setting
    This item lets you select the cable length to compensate for
    transmission loss.
    1. Display the SYSTEM SETUP menu.
    2. Select CABLE COMP by moving the joystick up or
    down.
    3. Select the most suitable cable length by moving the joy-
    stick to the right or left.
    The initial factory setting is S.
    S:Less than 400 m (1 300 ft)
    M:400 m (1 300 ft) to 700 m (2 300 ft)
    L:700 m (2 300 ft) to 900 m (3 000 ft)
    (When using RG-59U, BELDEN 9259 or equivalent
    cable)
    (2) Switch Buzzer Setting
    This item lets you select whether or not the switch buzzer
    sounds when a button is pressed.
    1. Display the SYSTEM SETUP menu.
    2. Select SWITCH BUZZER by moving the joystick up or
    down.
    3. Select ON or OFF mode by moving the joystick to the
    right or left.
    The initial factory setting is ON. 
    						
    							ERROR 2
    20
    Message Cause Note
    Lack of memory
    Memory capacity was
    exceeded while down-
    loading.
    ERROR 3 Causes except
    aboveDownloading not possi-
    ble for some reason
    other than the above.
        PRESET DATA LOAD
       CAM1:
       CAM2:
       CAM3:
       CAM4:
       CAM5:
       CAM6:
       CAM7:
       CAM8:
    P: Data saved.
    : No Data saved. (CAM1 - CAM8 of the initial factory
    setting are marked all 
    .)
    (1) Download Setting
    1. Display the PRESET DATA LOAD menu.
    2. Select a camera number between CAM1 and CAM8 by
    moving the joystick up or down.
    3. Press the PRESET/SET/PROGRAM PRESET button.
    4. The camera number and download menu appear on
    the monitor as shown below.
       CAM1:
        DOWN LOAD
        UP   LOAD
        DATA TITLE
    5. Select DOWN LOAD by moving the joystick up or down.
    6. Press the PRESET/SET/PROGRAM PRESET button.
    Downloading starts.
       CAM1:
        DOWN LOAD
        UP   LOAD
        DATA TITLE
        END 
    LOADINGBlinking
    7. While downloading, the word LOADING blinks on the
    right.
    changing to 
    Pin the progress bar indicates the
    progress of downloading.
    8. When downloading is completed, END appears on the
    right. The progress bar disappears.
    9. Editing the DATA TITLE.
    For further information, refer to (3) Data Title Setting.
    Notes:
    •The preset data of up to 8 cameras can be down-
    loaded.
    •Downloading time is approx. 2 minutes per camera.
    When downloading is completed, the combination cam-
    era such as WV-CS854, WV-CS654 or WV-CS604 will
    move to the Preset Position.
    •Any previous preset data is overwritten by the down-
    loaded data.
    •To terminate downloading, press the HOME/ESC button
    while downloading. ERROR 3 appears. The progress
    bar disappears.
    •END and error messages remain on the menu until the
    next operation is performed.
    •In case of RS-485 Site Communication mode, check
    that the unit address is the same as set on the combi-
    nation camera. If the numbers do not agree, the camera
    cannot be operated.
    Therefore, preset data cannot be downloaded.
    •Error Display
    When an error occurs during Down Loading, the follow-
    ing messages appear on the monitor.
    Preset Data Load Setting
    1. Display the Setup menu.
    2. Select PRESET DATA LOAD by moving the joystick up
    or down.
    3. Press the PRESET/SET/PROGRAM PRESET button.
    The PRESET DATA LOAD screen appears on the moni-
    tor as shown below. 
    						