Home > Telrad Digital > Communications System > Telrad Digital Emagen Unified Messaging System Manual

Telrad Digital Emagen Unified Messaging System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Telrad Digital Emagen Unified Messaging System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 22 Telrad Digital manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							76-110-0887/0, Issue 1
    7-8
    7.6 SECURITY PARAMETERS ON THE SITE --> SETTINGS SCREEN
    Administrator Password
    This number is required for access to all System Administrator func-
    tions. The password can contain up to 4 digits.
    Mailbox 
    This field tells 
    emaGEN how many digits make up a valid mailbox 
    number. This value is used to determine if a caller has dialed a mail-
    box number or a conversion table digit.
    Extension Length
    This field determines the 
    emaGEN PBX extension numbers length.
    Password Length
    This field determines how many digits are allowed for a mailbox us-
    ers password
    .
    7.7 GREETING HOURS PARAMETERS ON THE SITE --> SETTINGS 
    SCREEN
    emaGEN announces Good Morning, Afternoon, Evening 
    depending on the time of day. This field determines what these time 
    Legal values:0000 to 9999
    Default:0000
    Action:Enter from 1 to 4 digits for a desired pass-
    word
    Legal values:1 – 7 digits
    Default:3
    Action:Select from the drop box.
    Legal values:1 – 7 digits
    Default:3
    Action:Select from the drop box.
    Legal values:1 to 9 digits
    Default:4
    Action:Select from the drop box. 
    						
    							Section 7:  SITE
    7-9
    periods are. There can occur a situation in which the time greeting is 
    “Good morning” yet the department greeting still indicates that the 
    office is closed (night mode - set in department definition) - e.g. 
    05:00 AM.
    7.8 HOUSEKEEPING PARAMETERS ON THE SITE --> SETTINGS 
    SCREEN
    emaGEN has a house keeping mechanism, which cleans old mes-
    sages, according to parameters defined in class of service.
    Day
    This field entry determines on which day the house keeping will be 
    performed.
    Time
    Enter the time of day the housekeeping activity is to begin. This time 
    should be at a no/low traffic period. Typically this is between mid-
    night and 6 A.M.
    Purge reports
    Enter the number of months after which the system will delete old 
    report data.
    Legal values:12:00 to 11:59 / AM / PM
    Default:Morning - 12:00 AM, Afternoon - 12:00 PM, 
    Evening - 05:00 PM
    Action:Select from the drop box.
    Legal values:Sun too Sat, Daily
    Default:Daily
    Action:Select day from the drop box.
    Legal values:HH:MM AM/PM
    Default:02:59 AM
    Action:Select time from the drop box.
    Legal values:number of months
    Default:2 months
    Action:Select time from the drop box. 
    						
    							76-110-0887/0, Issue 1
    7-10
    7.9 SYSTEM PARAMETERS ON THE SITE --> SETTINGS SCREEN
    System Time Out
    This is the duration of the time period after playing a system prompt 
    that 
    emaGEN gives the caller to key in the desired number of an ex-
    tension. If no input is received during this time period, 
    emaGEN 
    continues on to the relevant NO-RESPONSE action.
    Recommended duration: 3 to 6 seconds.
    Script Time Out
    Script: This is the duration of the time period after playing a script 
    menu that 
    emaGEN gives the caller to key in the desired number or 
    extension. If no input is received during this time period, 
    emaGEN 
    continues on to the relevant ERR line for more actions.
    Recommended duration: 6 seconds.
    Conversion Table Time Out
    This field sets the inter-digit time-out for the conversion table. The 
    recommended time is 2000 msec. The entry should not be less than 
    800 msec.
    Weekdays Definition
    This field determines what days 
    emaGEN is to consider as a Week-
    day. Any day not entered here will be considered to be Weekend 
    day.
    Legal values:1-12 seconds
    Default:4 seconds
    Action:Select duration from the drop box.
    Legal values:1-12 seconds
    Default:5 seconds
    Action:Select duration from the drop box.
    Legal values:200-4000 msec
    Default:2000 msec
    Action:Enter the time-out period.
    Legal values:Days of the week
    Default:Monday, Tuesday, Wednesday, Thursday, 
    Friday 
    						
    							Section 7:  SITE
    7-11
    Page Wait
    This field determines the duration (in seconds) of the paging feature. 
    This is the time a caller can wait on the line while 
    emaGEN is paging 
    a subscriber. If the subscriber has not contacted the system within 
    this amount of time, the caller is prompted that the subscriber is not 
    available.
    7.10 CALL OUT PARAMETERS ON THE SITE --> SETTINGS SCREEN
    When emaGEN performs a Call Out, such as wake-up call, remote 
    message notification, etc., it dials out on outside trunk circuits. There 
    are two different results that 
    emaGEN may receive other than an 
    answered call.
    Busy
    This field controls the time interval between Call Out attempts for a 
    Busy condition.
    No Answer
    This field controls the time interval between Call Out attempts for a 
    No Answer condition.
    Action:Check all days to be considered weekdays.
    Legal values:1 to 9999 sec
    Default:Blank
    Action:Enter the desired time duration.
    Legal values:1 to 999 minutes
    Default:3
    Action:Enter desired number of minutes to wait be-
    fore retry.
    Legal values:1 to 999 minutes
    Default:30
    Action:Enter desired number of minutes to wait be-
    fore retry. 
    						
    							76-110-0887/0, Issue 1
    7-12
    7.11 PUBLIC ANNOUNCEMENT PARAMETERS
    Figure 7-3   Site --> Public Announcement screen
    emaGEN has the ability to activate the public announcement (PA) 
    feature of the PBX. This allows the following 
    emaGEN features: 
    First, if a mailbox owner is away from his/her phone, he/she can be 
    paged within the location and receive their calls at a phone else-
    where in the building. Second, 
    emaGEN can be programmed to 
    make up to eight special pre recorded announcements to be played 
    back at specific times and days.
    Number
    This is the ID number for the available schedule assignments.
    Prompt
    This is the prompt number that you record for a specific schedule an-
    nouncement.
    NOTE
    These prompts are hard-coded and may
    not be changed.
    Legal values:1 to 8
    Default:1 to 8
    Action:None.
    Legal values:See Action, below.
    Default:151 to 158
    Action:Record the appropriate prompts using the 
    To Record A Prompt option in the System 
    Administrator menu. 
    						
    							Section 7:  SITE
    7-13
    Day
    This field determines the day(s) on which a scheduled PA announce-
    ment will be made.
    P. A .  T i m e
    This field sets the time for a scheduled announcement to be made
    .
    P.A. Zone
    This determines the P.A. zone access code to which an announce-
    ment is directed. The access code MUST match the desired PBX 
    paging access code.
    7.12 HOLIDAY SCHEDULE
    Figure 7-4   Site --> Holiday Schedule screen
    Legal values:Daily, None, Day of week
    Default:None
    Action:Select from the drop box.
    Legal values:HH:MM AM/PM
    Default:12:00 AM
    Action:Select time from the drop box.
    Legal values:0-9, *, or # / use , for pause
    Default:Blank
    Action:Enter the page zone access code. 
    						
    							76-110-0887/0, Issue 1
    7-14
    emaGEN allows you to pre-program up to 16 holiday messages and 
    their dates into the system. When the internal calendar matches one 
    of these dates, the appropriate holiday greeting will be broadcast to 
    the caller. The appropriate operation mode defined in the Holiday 
    Operation Mode field in Department Definition will become active as 
    well. After the holiday message is played, the defined department 
    greetings will begin.
    Holiday name
    This is the ID number for the available schedule assignments.
    Date
    This field determines the date of the related holiday.
    Prompt
    This is the prompt number to record for this particular holiday. 
    Name
    These are the names for the holidays.
    Legal values:1-16 characters
    Default:None
    Action:None
    Legal values:MM/DD
    Default:00/00
    Action:Enter the desired month and day for this 
    schedule number or select a day from the se-
    lection calendar.
    Legal values:170-185
    Default:None
    Action:Record the appropriate prompts using the 
    To Record A Prompt option in the Adminis-
    trators menu.
    Legal values:1-20
    Default:None
    Action:Enter the holiday name. 
    						
    							Section 7:  SITE
    7-15
    7.13 CID ROUTING
    Figure 7-5    Site --> CID Routing screen
    The CID Routing table allows you to route calls based on the  caller 
    ID information. You can use a complete number or a partial number 
    (which includes only the area code, or area code + exchange).
    You can bind each number in this table with a specific mailbox (which 
    can also be a lead number for an ACD group or a script mailbox). 
    You can also specify the type of action to be taken with this number. 
    For example, you can define specific numbers to always be trans-
    ferred to a mailbox to take a message, and other to be transferred to 
    a live extension. 
    To add new numbers to this list:
     Click the NEW button.
    To remove numbers from the list:
    1. Check the REMOVE box.
    2. Click SAVE.
    The CID routing table is used in conjunction with the Script opcode 
    CID Routing. 
      
    						
    							76-110-0887/0, Issue 1
    7-16
    THIS PAGE INTENTIONALLY BLANK 
    						
    							8-1
    Section 8 
    PBX PORT DEFINITION
    8.1 GENERAL
    Figure 8-1   PBX --> Port Definition screen
    The Port Definition menu defines the 
    emaGEN port parameters on 
    the PBX --> Port Definition screen, as follows.
    8.2 PORT PARAMETERS
    Extension
    This is the extension number to which the particular port is connect-
    ed.
    Legal values:1-7 digits
    Default:Blank
    Action:Enter the related extension number
      
    						
    All Telrad Digital manuals Comments (0)