Home > Toshiba > Communications System > Toshiba Strata Ctx100, Ctx670 General Description Manual

Toshiba Strata Ctx100, Ctx670 General Description Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Toshiba Strata Ctx100, Ctx670 General Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Strata CTX670 Overview
    CTX670 License Control
    Strata CTX General Description    06/037
    Network Interface
    The processor has an on-board Ethernet 10Base-T Ethernet circuit for connection to Open 
    Architecture Computer Telephony Interface (CTI) applications. This provides extensive call 
    control and telephone support for CTI applications. The Ethernet Network Interface Card (NIC) 
    port also enables connection to the following:
     CTX Attendant Console
     ACD server 
     Local and Remote CTX WinAdmin PC
     Soft Key Control of Voice Mail features
    Maintenance Modem
    A built-in maintenance modem (33.6Kbps/V.34) on the processor can provide point-to-point local 
    or remote connection to the CTX WinAdmin administration software.
    CTX670 Processor PCB Subassemblies
    Subassemblies can be added to the processor PCBs to enable system expansion and provide 
    additional features. The subassemblies are:
     BEXS and BBMS expansion PCBs mount onto the processor PCBs to provide increased port 
    capacity, from Basic (192 ports) to Expanded (672 ports). The BEXS provides switching 
    capacity, and the BBMS provides memory capacity. For Basic and Expanded capacities of 
    stations, lines and features, see Ta b l e s  3~7. To expand the system, both subassemblies must be 
    installed.
     BSIS interface PCB which attaches to the BECU to provide up to four RS-232 interface ports 
    for SMDR Call Accounting and SMDI or Toshiba Proprietary Voice Mail interface.
    See Table 3 on page 11 for the number of cabinets and universal PCB slots for the Basic and 
    Expanded systems.
    CTX670 License Control
    The system size and feature capability is controlled using a software License Key Code. This key 
    code is obtained from the Toshiba Internet FYI site during the ordering process and is installed 
    onto the system processor via Strata CTX WinAdmin. Processor license codes activate system 
    hardware capacities in the following increments.
     The first 64 line/station ports do not require a license. Each additional set of four line/station 
    ports requires one LIC670-4 PORTS license (maximum of 672 ports).
     The on-board DTMF receiver circuit provides up to 32 DTMF receiver hardware circuits. The 
    first four DTMF circuits do not require a license. Each additional set of four DTMF receiver 
    circuits requires one LIC670-4 DTMF license (max. total of 32 DTMF circuits).
    NoteDTMF tone receiver circuits are required for standard telephones, Voice Mail DTMF 
    integration, Tie, DID and DNIS line service.
     The optional RS-232 serial port interface (BSIS) provides two circuits to interface with Voice 
    Mail, SMDI or Toshiba Proprietary Voice Mail integration, Call Accounting SMDR, and two 
    for future applications. The first circuit does not require a license, but circuits two through four 
    each require one LIC670-SER PORT license. 
    						
    							Strata CTX670 Overview
    CTX670 Cabinet Slots
    8Strata CTX General Description    06/03
    Licensed Software Options
    Some software options are activated with license codes. The following software options require a 
    license:
     Each CTX system (node) in a Strata Net QSIG Network (ISDN or IP) requires one LIC670-
    QSIG NET license. A maximum of four serial network nodes are allowed in any one serial 
    chain in the network topology.
     Each individual CTI Open Architecture application requires one LIC670-CSTA AP license 
    (maximum nine). 
    CTX670 Cabinet Slots
    Base Cabinet
    The Base Cabinet has two dedicated slots used for the system processor PCBs and eight universal 
    slots, labeled “S101~S108,” that can accommodate station, CO line or option PCBs (see Figure 4). 
    It also houses a power supply.
    Figure 4 Base Cabinet Interior
    POW
    +5V
    -5V
    P. F.
    RESET
    EXP
    BASEAC INBATT DC OUT
    -24V1
    -24V2
    -24V3
    -24V4
    +-
    POWER
    ON
    OFF
    FG5002B101 B102 S101 S102 S103 S104 S105 S106 S107 S108
    5466
    B101 B102 S101 S102 S103
    S104 S105 S106 S107S108 
    						
    							Strata CTX670 Overview
    CTX670 Remote Expansion Cabinet
    Strata CTX General Description    06/039
    Expansion Cabinets
    One to six Expansion Cabinets can be added to increase the system station and CO line capacity. 
    Each expansion cabinet provides 10 slots (S_01~S_10). Figure 5 shows an Expansion Cabinet.
    Refer to the following section for cabinet slot and station/line capacities. Ta b l e s  4 and 5 show the 
    number of stations and CO lines allowed when additional cabinets and PCBs are used.
    CTX670 Remote Expansion Cabinet
    A CTX670 Expansion Cabinet can be located up to three kilometers (1.86 miles) from its Base 
    Cabinet. Remote Expansion Cabinets are enabled by the RRCU PCB. One RRCU connects to up 
    to two ribbon-type Data Cables and applies the inter-cabinet signal to a multi-mode fiber-optic 
    pair. One fiber pair can support one or two Expansion Cabinets in one remote location using one 
    RRCU in the Base Cabinet and another in the Remote Expansion Cabinet.
    The CTX670 Base Cabinet supports up to six Remote Expansion Cabinets (at least one RRCU 
    PCB is required for each remote location).
    Remote Cabinets support the BIOU for external Page Zones, Night Bell, etc., and all CO line and 
    trunk interface PCBs. Network clock synchronization can only be derived from digital trunks 
    installed in the Base Cabinet (Master) location.
    A Remote Cabinet can support all PCBs that can be installed in a local Expansion Cabinet, 
    including digital trunk cards. However, the system cannot derive network clock synchronization 
    from a digital trunk installed in a Remote Cabinet. This requires a digital trunk installed in the 
    Base Cabinet or in a local Expansion Cabinet connected to the Base by a standard ribbon cable. 
    For each Remote Cabinet location, local trunks may be required for correct 911 service.
    S_01 S_02 S_03 S_04 S_05 S_06 S_07 S_08 S_09 S_10
    5003
    CABINET NO.
    2
    S_01 S_02 S_03 S_04 S_05
    S_06 S_07 S_08 S_09 S_1034567
    POW
    +5V
    -5V
    P. F.
    RESET
    EXP
    BASEAC INAC IN DC OUT
    -27V1
    -27V2
    -27V3
    -27V4
    +-
    POWER
    ON
    OFF
    FG5002
    POW
    +5V
    -5V
    P. F.
    RESET
    EXP
    BASEAC INBATT DC OUT
    -27V1
    -27V2
    -27V3
    -27V4
    +-
    POWER
    ON
    OFF
    FG5002
    Figure 5 Expansion Cabinet Interior 
    						
    							Strata CTX670 Overview
    CTX670 Remote Expansion Cabinet
    10Strata CTX General Description    06/03 
    						
    							Strata CTX General Description    06/0311
    Capacities3
    This chapter contains Strata CTX100 and CTX670 capacities for stations and peripherals, CO 
    lines, station buttons and system features. All tables apply to both systems unless otherwise noted.
    System Capacities
    Important!The maximum capacities listed for the CTX100 in Ta b l e s  3~7 are based on an 
    expanded CTX100 (Base + Expansion Cabinet).
     
      
    Table 3 Cabinet and Slot Capacities
    Cabinets/Slots/PortsCTX100CTX670
    Basic Processor
    BBCU + BECU
    CTX670
    Expanded Processor
    BBCU + BECU 
    + BEXS + BBMS
    Cabinets1 or 2 1 to 2 1 to 7
    Universal slots4 or 8 8 or 18 8 to 68
    Maximum capacity of ports 
    (lines + stations)112 192 672
    Table 4 Station/Peripherals System Capacities 
    StationsCTX100
    Base & ExpansionCTX670
    Basic Processor
    BBCU + BECUCTX670 
    Expanded Processor
    BBCU + BECU +
    BEXS + BBMS
    Add-on modules (DADM3120, 
    DADM3020) per Base Cabinet130 DKTs with 1 ADM
    23 DKTs with 2 ADMs55 DKTs with 1 ADM
    43 DKTs with 2 ADMs55 DKTs with 1 ADM
    43 DKTs with 2 ADMs
    Add-on modules (DADM3020) per 
    Expansion Cabinet131 DKTs with 1 ADM
    24 DKTs with 2 ADMs57 DKTs with 1 ADM
    45 DKTs with 2 ADMs57 DKTs with 1 ADM
    45 DKTs with 2 ADMs
    CTX Attendant consoles224
    DKT3000- and 2000-series DKTs172/system
    (40 Base Cabinet)
    (40/Expan. Cab.)152/system
    (72 Base Cabinet)
    (80/Expan. Cab.)552/system
    (72 Base Cabinet)
    (80/Expan. Cab.)
    IPT telephones64 per cabinet
    72 per system128 Base
    96 Expansion
    160 System128 Base
    96 Expansion
    560 System
    IPT telephones with DADM3120226 per cabinet
    26 per system58 per cabinet
    58 per system 200 per cabinet
    200 per system 
    						
    							Capacities
    System Capacities
    12Strata CTX General Description    06/03
    DKT2204-CT or DKT2304-CT Cordless 
    Telephone172 152 552
    Door locks4510
    Door phone control boxes (DDCB)238
    Door phones6924
    DSS consoles (DDSS)3516
    ISDN BRI station circuits TE-1 and TA 
    (2B+D per circuit)12 28 96
    Off-premise stations64 144 544
    BPCI used for TAPI only: per cabinet135 66 66
    Total Stations (Digital/Analog/ISDN BRI B 
    channel combined)72 160 560
    Standard stations64 144 544
    Calls existing at the same time56 96 366
    1. Limit is based on cabinet Power Factor (PF).
    2. Based on the maximum allowed flexible buttons.
    Table 5 Line Capacities and Universal PCB Slots 
    LinesCTX100Base & Expansion
    CTX670
    Basic
    Processor
    BBCU + BECU
    CTX670
    Expanded
    Processor
    BBCU + BECU +
    BEXS + BBMS
    CO lines – loop start 
    (analog - 8 lines/slot)64 96 264
    CO lines – ground start 
    (analog - 4 lines/slot)32 72 264
    DID lines (analog - 4 lines/slot)32 72 264
    Tie lines (analog - 4 lines/slot)32 72 264
    VoIP lines (4 lines/slot)1
    1. Capacity is limited by FCC, Part 15, ElectroMagnetic Compatibility (EMC) restrictions.
    82020
    T1 lines (DS-1)2
    2. T1 lines can be loop start, ground start, Tie or DID (maximum 24 lines per unit, any type or combination).
    64 96 264
    ISDN BRI B channel lines3
    3. BRI lines provide CO line services, including Caller ID, DID and Direct Inward Lines (DIL).
    64 96 256
    ISDN PRI B channel lines4
    4. PRI lines provide CO line services, including QSIG Networking, Calling Party Number/Name, DID, Tie, POTS, FX and DIT.
    48 96 264
    IP QSIG Channels5
    5. QSIG over IP channels provides Strata Net functionality.
    48 96 264
    Total lines (Analog, T1, ISDN BRI and PRI 
    B channels combined)64 96 264
    Channel Groups32 48 128
    Number of groups w/ GCO Line buttons32 50 128
    Table 4 Station/Peripherals System Capacities (continued)
    StationsCTX100
    Base & ExpansionCTX670
    Basic Processor
    BBCU + BECUCTX670 
    Expanded Processor
    BBCU + BECU +
    BEXS + BBMS 
    						
    							Capacities
    System Capacities
    Strata CTX General Description    06/0313
    Table 6 Station Buttons
    Station Buttons per SystemCTX100 Base & 
    ExpansionCTX670
    Basic Processor
    BBCU + BECUCTX670 Expanded 
    Processor
    BBCU + BECU 
    + BEXS + BBMS
    Call Forward, Personal CF Buttons72 160 560
    CO Line Buttons64 96 264
    Group CO Line Buttons64 96 264
    Pooled CO Line Buttons32 50 128
    CO Group and Pooled Line Buttons64 96 264
    Station Loop Buttons81550
    Door Unlock Buttons4816
    Flexible Telephone Buttons1600 3500 12000
    Line Buttons in use at the same time1440 3200 3200
    Message Waiting Registration (DNs with MW)130 230 800
    Multiple Appearances of DNs on Telephones2000 4000 12000
    Night Transfer Buttons24 8
    One Touch Buttons800 1750 6000
    Primary Directory Numbers [PDNs] per system72 160 560
    Phantom Directory Numbers [PhDNs] per system288 640 2240
    [PhDNs] with Message Waiting Indication LED18 38 128
    ISDN DNs96
    (8 DNs/station)224
    (8 DNs/station)768
    (8 DNs/station) 
    						
    							Capacities
    System Capacities
    14Strata CTX General Description    06/03
    Table 7 System Feature Capacities 
    FeaturesCTX100 Base & 
    ExpansionCTX670
    Basic Processor
    BBCU + BECU
    CTX670 Expanded
    Processor
    BBCU + BECU 
    + BEXS + BBMS
    Pilot DNs100200256
    Advisory LCD Messages (Set on a Telephone)111
    Advisory LCD Messages Lists (per System)101010
    Attendant Groups111
    Call Accounting SMDR Interface1111
    Call Forward, System CF Patterns41032
    Call Park Orbits (General)143264
    Call Park Orbits (Individual)5696336
    Caller ID/ANI/CNIS Numbers stored (Call History 
    records)Up to 100/stationUp to 100/stationUp to 100/station
    Up to 660/systemUp to 1000/systemUp to 2000/system
    CO Line Groups - Incoming Line Groups (ILG)3250128
    CO Line Groups - Outgoing Line Groups (OLG)3250128
    Outgoing Line Groups (OLG) Members per system
    (Trunks + ISDN Line Service Index)96144392
    Conference Circuits646496
    Conferencing (three-parties simultaneously)2202121
    Conferencing (eight-parties simultaneously)28812
    Conference Party types (up to 8 total lines + 
    stations)6 lines max.
    8 stations max.6 lines max.8 stations max.6 lines max.8 stations max.
    Two-CO Line Conferencing – simultaneously2 
    (Two party only, no telephone or VM port)3248132
    Conference/Line Volume Adjustment (PAD) Groups61032
    DID Numbers for Calling Number ID/system2255001000
    DNIS/DID Network Routing Numbers2004001000
    DNIS/DID Numbers45010002000
    DTMF Receivers3161632
    E911 Groups888
    Emergency Call Groups888
    Hunt Groups (Serial/Circular/Distributed combined)90200640
    Hunt Group Size (DNs per group)72160560
    Hunt Group Stations (per system)3608002800
    ISDN DNs96224768
    ISDN Line Service Indexes3248128
    Multiple Call Ring Group163264
    Night Bell Control Relay4111
    Night Transfer Control Relay4111
    Off-hook Call Announce Handsets (simultaneous)202131
    Off-hook Call Announce to Telephone Speakers 57211 2352
    Page Mute External BGM Control Relay4111 
    						
    							Capacities
    System Capacities
    Strata CTX General Description    06/0315
    Page Zone Relays4888
    Page Groups (Phones with or without External 
    Zones)4816
    Paging – (Group Page – simultaneous stations 
    paged)72120120
    Pickup Groups51032
    Ring Tones (External Call Ring Tones for DKTs)444
    Ring Tones (Internal Call Ring Tones for DKTs)111
    Speed Dial - Station SD numbers per system6108024005600
    Speed Dial - System SD numbers per system800800800
    Stratagy DK Voice Mail Systems per system111
    Tenants111
    Destination Restriction Level (DRL) Classes161616
    Verified Account Codes1353001000
    Voice Mail SMDI Interface1111
    1. SMDI and SMDR require BSIS serial port interface.
    2. Conference circuits are used dynamically, so the maximum number of simultaneous conferences is affected by the number of 
    conference members in each conference. The total number of members in simultaneous conferences cannot exceed the total 
    number of conference circuits. Each conference can have up to eight members.
    3. DTMF receivers are required for standard touch tone telephones, voice mail integration, Tie, DID and DISA lines.
    4. An option BIOU is required for up to four zone page relays and four control relays on the CTX100 and CTX670. One control 
    relay is provided on board the CTX100 processor.
    5. Speaker OCA capacity is determined by 2B channel slot availability and power supply. Requires BVSU option in telephone. 
    Speaker OCA is not available on IPT1020-SD telephones.
    6. Up to 100 Station SD numbers, allocated in increments of 10, can be programmed per station.
    Table 7 System Feature Capacities (continued)
    FeaturesCTX100 Base & 
    ExpansionCTX670
    Basic Processor
    BBCU + BECUCTX670 Expanded
    Processor
    BBCU + BECU 
    + BEXS + BBMS 
    						
    							Capacities
    CTX100 Maximum Capacity Configuration Examples
    16Strata CTX General Description    06/03
    CTX100 Maximum Capacity Configuration 
    Examples
    Table 8 CTX100 Base Cabinet with Digital Telephones and Loop Start Line With or Without Caller ID 
    Ta b l e  9CTX100 Base and Expansion Cabinet with Analog Loop Start Lines 
    Table 10 CTX100 Base Only: Digital Telephones and T1 and/or PRI lines
    4 Universal Slots
    40 Stations (Max.)
    24 CO lines (Max.)
    44 Stations + Analog loop start lines combined (Max.)
    StationsAnalog loop start lines 
    404 (none can have Caller ID)
    328 (all can have Caller ID)
    3216 (none can have Caller ID)
    1616 (8 can have Caller ID)
    241
    1.  Using ADKU.
    8 (none can have Caller ID)
    8 Universal Slots
    72 Stations (Max.)
    56 CO lines (Max.)
    92 Stations + Analog Loop Start Lines combined (Max.)
    StationsAnalog loop start lines 
    7220 (none can have Caller ID)
    7216 (8 can have Caller ID)
    6432 (none can have Caller ID)
    6424 (8 can have Caller ID)
    6416 (all can have Caller ID)
    4840 (none can have Caller ID)
    4832 (8 can have Caller ID)
    4824 (16 can have Caller ID)
    3248 (none can have Caller ID)
    3240 (8 can have Caller ID)
    3232(16 can have Caller ID)
    3224 (24 can have Caller ID)
    1632 (24 can have Caller ID)
    4 Universal Slots
    40 Stations (Max.)
    48 lines (Max.)
    64 Stations + T1 and/or PRI lines combined (Max.)
    StationsT1 and/or PRI lines
    4024/23
    3240/40
    1648/46 
    						
    All Toshiba manuals Comments (0)