A 1 . _ 
TBZ 
HOXB TB3 
- - _ _ _ _ _ - 
J L-l I 
NOTE. For OPX operafion. the control data 
crrcuircommecrion for EKT21 isnotrequired. 
INSTALLATION PROCEDURES 
SECTION 300-006-200 
MAY 1986 
are 
FCC registered 
with a facility inter- 
face code of OL 13A. 
lf an alternate DC 
supply/ritig 
gener- 
ator is to be used, 
con tact your Toshiba 
supplier for details. 
3) 
HOXB-to-convention- 
al single-line telephone 
connections are made 
from the telephone to 
the HOXB terminal strip 
(TB2) with...

Page 32

INSTALLATION PROCEDURES 
SECTION 300-006-200 
MAY 1986 
1, 2 and 3 (RJ-25C) or 1, 2 or 3 (RJ-1 1C) are 
connected to the CO 1, 
2, 3 (or CO 1, CO 2 or 
CO 3) in connectors on the HOLB unit. Then, 
connect a g-wire cable from the HOLB to the 
CO l-3 connector on the right side panel of 
the HKSU. An 8-wire factory-provided cable is 
connected from the HOLB l-3 connector (on 
the HKSU left side panel) to the HOLB unit. 
Connect up to three conventional, single-line 
telephones to the modular connectors...

Page 33

INSTALLATION PROCEDURES 
SECTION 300-006-200 
MAY 1986 
FIGURE 23-IO-key BLF EKT 
07.02 Three additional EKTs that are very 
similar to the lo-key, but with 10 additional 
keys, are also available. The 20-key EKT (Fig- 
ure 24) is available as a speakerphone or with 
handsfree answerback only. The two models, 
identical in appearance, are equipped with 
four permanently dedicated keys and 20 line/ 
feature keys. The HFU model may be answered 
handsfree on intercom calls only. A 20-key 
Liquid Crystal...

Page 34

INSTALLATION PROCEDURES 
SEETION 300-006-200 
MAY 1986 
clock/calendar in its idle state. In use, the dis- 
play provides elapsed time of call (incoming or 
outgoing), dialed number, calling station or CO 
line. 
07.09 All EKTs feature modular handset 
cords and are connected to the system via 4- 
conductor modular line cords. In addition, each 
EKT model may be used at any or all stations. 
07.10 
EKT Wall Mounting 
07.11 
All EKTs are mounted in the same 
manner, and they may be mounted on a wall 
or...

Page 35

FIGURE 29-HANDSET HANGER 
07.20 EKT Connections 
07.21 
Connect the appropriate length line 
cord to the modular connector, route the cord 
to the EKT and connect to the EKT modular 
jack. Test the EKT per Paragraph 09. 
08 SYSTEM POWER-UP INITIALIZE 
08.00 General 
08.01 
Stasta V/e has a list of standard 
_- 
system data assignments stored in ROM that 
can be entered at any time by performing the 
initialize sequence outlined below. The system 
must be initialized when it is first installed or...

Page 36

INSTALLATION PROCEDURES 
SECTION 300-006-200 
MAY 
1986 
must be cleared to prevent meaningless num- 
bers from being dialed. 
IMPORTANT! 
Station 17 may be equipped with either 
a 
1 O-key or a 20-key EKT. Prior to per- 
forming the procedure that follows, 
refer to Paragraph OZ.ZO/Figure I, Pro- 
gramming Procedures, Section 300-006- 
300, for instructions on using a I O-key 
EK T for programming. 
08.12 
To clear the Automatic Dialing (-Sys- 
tern and -Station) memory (up to 40 numbers), 
proceed as...

Page 37

INSTALLATION PROCEDURES 
SECTION 300-006-200 
MAY 
1986 
l LED #2 displays current data. 09 SYSTEM TEST PROCEDURES 
3) Use the INC switch to correct data in LED 
#2 display. 09.00 EKT Functional Check 
4) Depress the MOD switch once. 
l LED #l displays 2 (month). 
l LED #2 displays current data. 
5) Use the 
INC switch to correct data in LED 
#2 display. 
09.01 In order to verify basic system func- 
tions, and confirm the proper functioning of 
the EKT itself, perform the following test 
procedures at...

Page 38

INSTALIATIDN PROCEDURES 
SECTION 300-006-200 
MAY1986 
j) Depress the m key. 
l CO 1 LED: l-use flash. 
l SPKR & MIC LEDs: on steady. 
l Listen for CO/PBX dial tone via the EKT 
speaker. 
k) Depress the m key. 
l CO 1 LED: i-hold flash. 
l Speaker off (no dial tone). 
. SPKR & MlC LEDs: off. 
I) Depress the m key. 
l CO 1 LED: l-use flash. 
l SPKR & MIC LEDs: on steady. 
l Listen for CO/PBX dial tone via the EKT 
speaker. 
m) Depress the m key. 
l CO 1 LED: Conference call fiash rate. 
l Dial tone...

Page 39

INSTALLATION PROCEDURES 
SECTION 300-006-200 
MAY1986 
a) Lift the OPX handset and listen for intercom 
dial tone. 
b) Dial the number of another station. 
l Dial tone will stop when the first digit is 
dialed. 
l Ringing or voice paging will be heard at 
the called station. 
c) Lift the handset at the called station. 
l Ringing stops. 
d) Verify that a 2-way voice connection exists 
between the OPX and the called station. 
e) Go on-hook at both stations. 
f) Lift the OPX handset and listen for intercom...

Page 40

INSTAUATION PROCEDURES 
SECTION 300-006-200 
MAY 1986 
established. i) Put the printer “on-line” (DTR signal on). 
p) Lift the OPL telephone handset. 
l Verify that a 3-way voice connection is 
established. 
q) Go on-hook at both stations. 
09.30 
SMDR Functional Check 
l Call record will be output. 
j) Make an incoming call to the system and 
delay answering it for several rings. 
k) Answer the call. 
09.31 Perform the following test to verify 
the proper functioning of the SMDR feature. I) Enter an...