Page 31
A 1 . _ TBZ HOXB TB3 - - _ _ _ _ _ - J L-l I NOTE. For OPX operafion. the control data crrcuircommecrion for EKT21 isnotrequired. INSTALLATION PROCEDURES SECTION 300-006-200 MAY 1986 are FCC registered with a facility inter- face code of OL 13A. lf an alternate DC supply/ritig gener- ator is to be used, con tact your Toshiba supplier for details. 3) HOXB-to-convention- al single-line telephone connections are made from the telephone to the HOXB terminal strip (TB2) with...
Page 32
INSTALLATION PROCEDURES SECTION 300-006-200 MAY 1986 1, 2 and 3 (RJ-25C) or 1, 2 or 3 (RJ-1 1C) are connected to the CO 1, 2, 3 (or CO 1, CO 2 or CO 3) in connectors on the HOLB unit. Then, connect a g-wire cable from the HOLB to the CO l-3 connector on the right side panel of the HKSU. An 8-wire factory-provided cable is connected from the HOLB l-3 connector (on the HKSU left side panel) to the HOLB unit. Connect up to three conventional, single-line telephones to the modular connectors...
Page 33
INSTALLATION PROCEDURES SECTION 300-006-200 MAY 1986 FIGURE 23-IO-key BLF EKT 07.02 Three additional EKTs that are very similar to the lo-key, but with 10 additional keys, are also available. The 20-key EKT (Fig- ure 24) is available as a speakerphone or with handsfree answerback only. The two models, identical in appearance, are equipped with four permanently dedicated keys and 20 line/ feature keys. The HFU model may be answered handsfree on intercom calls only. A 20-key Liquid Crystal...
Page 34
INSTALLATION PROCEDURES SEETION 300-006-200 MAY 1986 clock/calendar in its idle state. In use, the dis- play provides elapsed time of call (incoming or outgoing), dialed number, calling station or CO line. 07.09 All EKTs feature modular handset cords and are connected to the system via 4- conductor modular line cords. In addition, each EKT model may be used at any or all stations. 07.10 EKT Wall Mounting 07.11 All EKTs are mounted in the same manner, and they may be mounted on a wall or...
Page 35
FIGURE 29-HANDSET HANGER 07.20 EKT Connections 07.21 Connect the appropriate length line cord to the modular connector, route the cord to the EKT and connect to the EKT modular jack. Test the EKT per Paragraph 09. 08 SYSTEM POWER-UP INITIALIZE 08.00 General 08.01 Stasta V/e has a list of standard _- system data assignments stored in ROM that can be entered at any time by performing the initialize sequence outlined below. The system must be initialized when it is first installed or...
Page 36
INSTALLATION PROCEDURES SECTION 300-006-200 MAY 1986 must be cleared to prevent meaningless num- bers from being dialed. IMPORTANT! Station 17 may be equipped with either a 1 O-key or a 20-key EKT. Prior to per- forming the procedure that follows, refer to Paragraph OZ.ZO/Figure I, Pro- gramming Procedures, Section 300-006- 300, for instructions on using a I O-key EK T for programming. 08.12 To clear the Automatic Dialing (-Sys- tern and -Station) memory (up to 40 numbers), proceed as...
Page 37
INSTALLATION PROCEDURES SECTION 300-006-200 MAY 1986 l LED #2 displays current data. 09 SYSTEM TEST PROCEDURES 3) Use the INC switch to correct data in LED #2 display. 09.00 EKT Functional Check 4) Depress the MOD switch once. l LED #l displays 2 (month). l LED #2 displays current data. 5) Use the INC switch to correct data in LED #2 display. 09.01 In order to verify basic system func- tions, and confirm the proper functioning of the EKT itself, perform the following test procedures at...
Page 38
INSTALIATIDN PROCEDURES SECTION 300-006-200 MAY1986 j) Depress the m key. l CO 1 LED: l-use flash. l SPKR & MIC LEDs: on steady. l Listen for CO/PBX dial tone via the EKT speaker. k) Depress the m key. l CO 1 LED: i-hold flash. l Speaker off (no dial tone). . SPKR & MlC LEDs: off. I) Depress the m key. l CO 1 LED: l-use flash. l SPKR & MIC LEDs: on steady. l Listen for CO/PBX dial tone via the EKT speaker. m) Depress the m key. l CO 1 LED: Conference call fiash rate. l Dial tone...
Page 39
INSTALLATION PROCEDURES SECTION 300-006-200 MAY1986 a) Lift the OPX handset and listen for intercom dial tone. b) Dial the number of another station. l Dial tone will stop when the first digit is dialed. l Ringing or voice paging will be heard at the called station. c) Lift the handset at the called station. l Ringing stops. d) Verify that a 2-way voice connection exists between the OPX and the called station. e) Go on-hook at both stations. f) Lift the OPX handset and listen for intercom...
Page 40
INSTAUATION PROCEDURES SECTION 300-006-200 MAY 1986 established. i) Put the printer “on-line” (DTR signal on). p) Lift the OPL telephone handset. l Verify that a 3-way voice connection is established. q) Go on-hook at both stations. 09.30 SMDR Functional Check l Call record will be output. j) Make an incoming call to the system and delay answering it for several rings. k) Answer the call. 09.31 Perform the following test to verify the proper functioning of the SMDR feature. I) Enter an...